| 1 | Taking down carefully storage type water heater (Geysers) of any make and any capacity at any height opening for inspection compete includingheating element inner copper tank etc. De-scalingcleaningand re-assembling of Geysers after repairs carrying out and re-fixing in same position (spares as required for repair geyser are measured and paid separately) including making good to walls with CM 1:3 or PCC 1:2:4 and plastering the wall surfaces with CM 1:6and replacement of old nuts, bolts and rubber gasket etc complete all as specified and directed. |
| 2 | Supply and fix 1.5 KW capacity heating element, push/ screw type with ‘O’ ring including making electrical connection including taking down old heating elementcomplete all as specified and directed.Make - Theeta/hotmax/Elcon or equivalent. |
| 3 | All as per serial item number 2.00 here-in-before above but of capacity 2.0/3.0 KWMake - Theeta/hotmax/Elcon or equivalent. |
| 4 | Supply and fix geyser assembly suitable for 25 litre capacity, ISI marked including taking down old unserviceable geyser assembly complete all as specified & directed. |
| 5 | Supply and fix thermostate suitable for 25 litre geyser, ISI marked including taking down old thermostate complete all as specified & directed. Make- Theeta/Bajaj/Hotmax/Elcon |
| 6 | Supply and fix thermostate suitable 3 litre instant geyser, ISI markedincluding taking down old thermostate complete all as specified & directed. Make- Theeta/Bajaj/Hotmax/Elcon |
| 7 | Supply and fix safety valve suitable for 25 litre geyser and 3 litre instant geyser (ISI marked) including taking down old safety valve complete all as specified & directed. |
| 8 | Supply and fix fastners screw for fixing25 litre Geyser including taking down old screw complete all as specified & directed. |
| 9 | Supply and fix inner tank made of steel suitable for 25 litre geyser including taking down old unserviceable inner tank complete all as specified & directed. |
| 10 | Supply and fix outer tank made of steel suitable for 25 litre geyser including taking down of old unserviceable outer tank complete all as specified & directed. |
| 11 | Supply and fix bottom cover suitable for 25 Litre Geyser including including taking down old unserviceable bottom cover complete all as specified & directed. |
| 12 | Supply and fix indicating lamp 230 volts 50 HZ AC suitable for geyser any type (round,squire or rectangular type) and any capacity including taking down old indicating lamp complete all as specified & directed. |
| 13 | Supply and fix sheet metal enclosure with industrial type 3 pin socket and plug including one MCB single pole 20 Amps 240 volts 50 HZ including taking down old sheet metal enclosure complete all as specified & directed. |
| 14 | Supply and fix in repairs 15 mm dia stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed complete all as specified & directed. |
| 15 | Supply and fix in repairs 15 mm dia bib taps,cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed complete all as specified & directed. |
| 16 | Supply and fix PVC connection pipe duly chromium plated 8mm dia both end threaded including brass coupling bolt cone washer complete, length of pipe is not less than 450mm suitable for hot/cold water system including taking down old PVC connection complete all as specified & directed. |
| 17 | Supply and fix pressure release valve suitable for 25 Ltr capacity geyser including taking down old valve complete all as specified and directed. |
| 18 | Supply and fix in repairs PVC insulated and sheathed flexible wire 3.0 core with copper conductor 40/0.076 round type for Geyser of approved make complete all as specified and as directed. |
| 19 | Material and labour for repair/replacement of sub main wiringwith two single core PVC insulated unsheathed cable 1100 volts grade, 2.5 Sqmm size with multistranded copper conductor FRLS cable (with colour code), drawn in but including non metallic rigid PVC cassing/cappingof 25 mm width, ISI markedincluding PVC insulated unsheathed 2.5 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete all as specified and as directed. Note:- Two runs of PVC cable with one run of PVC earth wire and one run of PVC conduit shall be measured and paid as one length only. |
| 20 | Supply and fixin repairs plug top for 15/16 Amp multipurpose sockets complete all as specified and as directed. |
| 21 | Supply and fix in repairs switch socket combined outlet 6 pin fulsh 15 Amp multipurpose complete all as specified and as directed. |
| 22 | Supply onlyMCB 6 to 32 amps single pole 240 Volts, complete all as specified and directed. |
| 23 | Material and labour for de-scaling of solar water heater, borocilicate glass tube using water and Eco-friendly chemical and cleaning/ rectifying Hot water circulation blokage of any capacity complete all as specified and directed. |
| 24 | Supply and fix in repairs solar water heater glass tube having 58mm outer dia and 1800mm length, suitable for 100/ 200 LPD complete all as specified and directed. |
| 25 | Supply and fix in repairs solar water heater glass tube having 58mm outer dia and 2100mm length, suitable for500/ 1000 LPD complete all as specified and directed. |
| 26 | Supply and fix heating element for solar water heating system of capacity 2 KW including taking down old heating element complete all as specified and directed.MAKE : BAJAJ/RECOLD/SPHERHOT |
| 27 | Supply and fix heating element for solar water heating system of capacity 3 KW including taking down old heating element complete all as specified and directed.MAKE : BAJAJ/RECOLD/SPHERHOT |
| 28 | Supply and fix in repair compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like includind caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates grade Fe-290 (Gde E-165), including all lattice bars, stiffeners, gusset plates etc welded together, anchor duly painted with two coats of synthetic enamel paint over and coat of red oxide primer and and forming PCC work and 12mm thick etc complete to avoidany deformation complete all as specified and directed. |
| 29 | Supply and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floorscomplete of size 25mm including union, bends and tees complete all as specified. Make: Astral/Supreme |
| 30 | Supply and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floorscomplete of size 20mm including union, bends and tees complete all as specified. Make: Astral/Supreme |
| 31 | Dismantling old defective FPC solar water heater collector of any type any make. |
| 32 | Supply and fix MNRE registered/approved polyester powder coated solar water heater Flat plate collector with high transmitive clear toughened glass glazing having absorber material as headers, risers and fins made up of 99.9% pure copper with selective black chrome coating with ultra sonic laser permanent bonding between copper fins & tubesell with inlet and outlet connections with collector top and bottom leg complete suitable for 200 LPD with minimum one year warranty complete all as specified and directed. |
| 33 | Supply and fix MNRE registered/approved polyester powder coated solar water heater Flat plate collector with high transmitive clear toughened glass glazing having absorber material as headers, risers and fins made up of 99.9% pure copper with selective black chrome coating with ultra sonic laser permanent bonding between copper fins & tubesell with inlet and outlet connections with collector top and bottom leg complete suitable for 100 LPD with minimum one year warranty complete all as specified and directed. |
| 34 | Taking down of Old U/S hot water tank of any capacity any make. |
| 35 | Supply and fix MNRE registered/approved 100 LPD non pressurised FPC stainless steel hot water tank with inner tank material SS 304with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high densityPUF insulation with thermostat and heater coil 2 KW and suitable size ofMS powder coated stand 32x3 mm angle frame with required PCC work 1:2:4for foundation/fixingcomplete all as specified and directed. |
| 36 | Supply and fix MNRE registered/approved 200 LPD non pressurised ETC stainless steel hot water tank with inner tank material SS 304with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high densityPUF insulation with 20 tube holes of 58mm diameter and outer PPGI with 20 Nos of58x1800 mm tubes, thermostat and heater coil 2 KW and suitable size ofMS powder coated stand 25x3 mm angle frame with required PCC work 1:2:4for foundation/fixing complete all as specified and directed. |
| 37 | Supply and fix MNRE registered/approved 100 LPD non pressurised ETC stainless steel hot water tank with inner tank material SS 304with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high densityPUF insulationwith 10 tube holes of 58mm diameter and outer PPGI with 10 Nos of58x1800 mm tubes with thermostat and heater coil 2 KW and suitable size ofMS powder coated stand 32x3 mm angle frame with required PCC work 1:2:4for foundation/fixing complete all as specified and directed. |