| 1 | Dismantling wall and ceiling boards (fiber, pulp, insulation, etc) or insulation board/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed. |
| 2 | M&L for providing and fixing inter locking metal grid (snap grid for false ceiling) of size 605 mm x 605 mm in true horizontal level, hot dipped galvanized steel sections (galvanized @ 120 grams/sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24 mm X 38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200 mm x 600 mm and secondary cross “T” of length 600 mm and size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200 mm X 600 mm panel to form grids of 600 mm X 600 mm and wall angle of size 24 mm X 24 mm X 0.4 mm. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 mm X 37 mm X 25 mm X 1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 mm X 30 mm X 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint for all hights complete all as specified and as directed. |
| 3 | M&L for 4 mm thick non-asbestos fibre cement building board and fixed on aluminium grid with screws complete all as specified and as directed. |
| 4 | S&F for PVC wall panelling in repair with panel of 300mm x 6mm holow section of Sintex pattern SPUF-146 or equivalent, fixed wih PVC plug and screw and inserted to next panel groove, edges and corners of all door/window/openings etc to be covered with PVC angle fixed with solvent cement as manufacturer\"s instructions complete all as specified and as directed. |
| 5 | Dismantling/removing existing roof treatment any thickness and specification consisting ofscreed, tar felts etc, and removing the dismantled materials outside MoD land complete all as specified and as directed. |
| 6 | M&L for bitumen felt water proofing treatment using APP based polymeric membrane not less than 3 mm thick, weighing not less then 3.00 kg / Sqm, reinforeced with polyster non-woven fabric (weighing not less than 150 gm/sqm) laid over and including cold bitumen primer appliedat the rate of 0.30 kg/sqm by forced application complete all as specified and as directed. |
| 7 | M&L for providing cement concrete type B0 1:2:4 (using 12.5mm graded stone aggregate) as in roof padding to achieve the required slope and smooth surface and in coping, benching etc mixed with liquid water proofing compound as per manufactures instructions complete all as specified and as directed.Note : Liquid WPC shall be measured and paid separately under relevant item of this BOQ. |
| 8 | M&L for cement concrete tiles 20cm x 20cm x 20mm thick, with grey cement and no pigments, machine pressed, set jointed and pointed in neat cement slurry in floor laid over and including 15 mm thick screed bed in cement mortar 1:6 and filling the joints with Tile Mix premium cementitious grout material of JK Cement or its equivalent complete all as specified and as directed. |
| 9 | Demolition of Brick work or stone/boulder masonary, buitd in cement mortor or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and as directed. |
| 10 | M&L for Brick work with sub-class \"B\" Bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 11 | Taking down cement plaster on brick work or concrete surface including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed. |
| 12 | M&L for rendering 15 mm thick on fair faces of brick wall or concrete surface in cement mortar 1:4 finished even & smooth without using extra cement complete all as specified and as directed. |
| 13 | M&L rendering 15mm thick on other than fair face of brick work or concrete surface in cement mortar 1:4 by mixing liquid water proofing compound as per manufacturers instructions and finished surface even and smooth without using extra cementcomplete all as specified and as directed.Note :- Liquid WPC shall be measured & paid separately under relevant item of this BOQ. |
| 14 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 15 | M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and fair complete all as specified and as directed. |
| 16 | M&L for rendering 10 mm thick on fair faces of bricks or concrete surfaces as in ceiling surfaces in cement mortar 1:3 finished even & fair all as specified and as directed. |
| 17 | M&L for providing damp proof layer in two coats of acrylic polymer coating consisting of 1 part of acrylic polymer liquid mixed with 2 parts of cementious powder applying at the rate of 1.40 Sqm/Kg of mix per coat. Second coat should be applied after 4-6 hrs of first coat, 5 days curing is to be carried out to the surface before providing plastering complete all as specified and as directed.Note : Make of the material \"Smart Care damp block 2K\" of Asian paints or equivalent from Dr Fixit, STP, CICA etc. as approved by GE |
| 18 | M&L preparation of newly plastered surfaces of walls, providing 1mm thick wall care putty to achieve smooth surface and applying two coats of oil bound distember over a coat of alkali resistant primercomplete all as specified and as directed. |
| 19 | M&L preparation of newly plastered surfaces of ceiling, providing 1mm thick wall care putty to achieve smooth surface and applying two coats of oil bound distember over a coat of alkali resistant primercomplete all as specified and as directed. |
| 20 | M&L preparation of newly plastered surfaces of walls and applying two coats of cement base paint white or tinted over a coat of primer complete all as specified and as directed. |
| 21 | Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) including interlocking tiles complete all as specified and as directed. |
| 22 | M&L for 75 mm thick cement concrete type D2 1:4:8 (using 40mm graded stone aggregate) as in sub base Sub floor, foors and paving etc complete all as specified and as directed. |
| 23 | M&L for chequred cement concrete tiles of size 20cm x 20cm x 25mm with white cement and pigments, set jointed and pointed in neat cement slurry in floors laid over and including 20 mm thick screed bed in cement mortar 1:4 complete all as specified and as directed. |
| 24 | M&L for sand cushioning 25 mm thick over PCC sub base all as specified and as directed. |
| 25 | M&L for Machine pressed precast concrete interlocking paver blockwith grey cement and pigmentany shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade of concrete as in floors/pavements complete all as specified and as directed. |
| 26 | M&L for 75mm thick cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in plinth protection/path laid in panel surface finished even and fair without using extra cement complete all as specified and as directed. |
| 27 | Dismantling of Asbestos Cement (corrugated or semi-corrugated) sheets in roof covering including ridges, hips, valleys and flashings etc complete all as specified and as directed. |
| 28 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness including ridge, hips, valleys etc complete all as specified and as directed. |
| 29 | S&F 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and as directed. |
| 30 | S&F asbestos cement two piece adjustable plain wing ridge 6mm thick for corrugated or semi-corrugated sheets fixed with L-type or J-type or cranked hook bolts complete all as specified and as directed. |
| 31 | S&F 6mm thick Asbestos Cement, corrugated or semi-corrugated sheets in roofs, walls, etc fixed with L-type or J-type or cranked hook bolts complete all as specified and as directed. |
| 32 | S&F Galvanised corrugated mild steel sheeting 0.63mm thick with two corrugation side lap, fixed with coach screw and washers, in roofs, walls etc with grade of zinc coating 275 complete all as specified and as directed. |
| 33 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as per IS 15965: 2012 in roof covering/cladding to wall fixed with self tapping screws complete all as specified and as directed. |
| 34 | S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as per IS 15965: 2012 fixed with self tapping screws complete all as specified and as directed. |
| 35 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 36 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out portion embedded in concrete, Brick work masonry etc and making good disturbed area complete all as specified and as directed. |
| 37 | Dismantling timber scantlings 40sqcm and over in section, in any position in framed work complete all as specified and as directed. |
| 38 | M&L for rolled mild steel work as in roof trusses (framed), tubular trusses, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sctions, MS hollow pipe) including distance pieces, cleats etc conforming to Fe 410W Gde E-250 quality \"A\" complete all as specified and as directed. |
| 39 | M&L for mild steel work as in wind ties for roof covering including securing botls etc including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 40 | S&F plates (plain or chequered) chennels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming to FE-410W Gde E-250 quality \"A\" complete all as specified and as directed. |
| 41 | M&l for preparation of new steel surfaces of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and as directed. |
| 42 | Dismantling fencing wire mesh any type complete all as specified and as directed. |
| 43 | Dismantling galvanised 2 strand, steel barbed wire, concertina coil in fencing complete all as specified and as directed. |
| 44 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm as in soft/loose soil complete all as specified and as directed. |
| 45 | M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundations filling and mass concrete complete all as specified and as directed. |
| 46 | S&F Mild steel work as in hand rails, half round or other section, balustersrunning bars, nosing to steps, wind ties, posts and struts in fencing incl cutting tops to shape as required, drilling holes , noching for wire , flat iron fillets for securing wiremesh etc. incl all necessary drilling, bolting or riveting etc & similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 47 | S&F mild steel round bars 10mm dia cut to length, bent to shape required bent to shapehoking end required and fixed in fencing confirming to Fe 410-W or Fe 290 complete all as specified and as directed. |
| 48 | S&F Mild steel screw bolts (machine made)5 to 10mm dia with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and as directed. |
| 49 | Supply only MS galvanised chain link fencing any size or type complete as specified and as directed. |
| 50 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete as specified and as directed. |
| 51 | S&F galvanised 2 strand steel barbed wire 2.24mm, dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provn of galvanised mild steel wire staples or steel pins complete as specified and as directed.Note: (Each line wire to be measured) |
| 52 | Supply and fix galvanised punched type concertina coil of loop dia 450 mm (dia of coil when upstretched) fixed to existing angle post strut and tying at three places ie two bottom & one at top with 3.15 mm dia galvanised mild steel wire complete all as specified and as directed. |
| 53 | M&L preparation of old plastered surfaces of walls and applying one coats of cement base paint white or tinted complete all as specified and as directed. |
| 54 | Material & Labour for road side kerb factory made Precast cement concrete block of mix 1:2:4 type B-1 (using 20 mm graded stone aggregate) of size 300 x 300 x 150mm jointed in cement mortar 1:4 complete all as specified and as directed. |
| 55 | M&L for 25 mm thick (average) thickness cement concrete 1:2:4 type B0 (using 12.5 mm graded aggregate) as in leveling course in floor complete all as specified and as directed. |
| 56 | M&L for machine pressed glossy pattern chequred cement concrete coloured tiles of size 30cm x 30cm x 25mm with grey cement and pigments, laid, set jointed and pointed in neat cement slurry in floors over and including 20 mm thick screed bed in cement mortar 1:6 complete all as specified and as directed. |
| 57 | M&L for cement concrete 1:2:4 type-B1 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed. |
| 58 | Demolition and breaking up 300 mm internal dia drain pipe (salt glazed ware, AC or reinforced cement concrete) set in cement mortar including cement concrete bedding and haunching and removing the demolished material out of MoD land complete all as specified and as directed. |
| 59 | M&L for reinforced concrete pipes, class NP-2, 300 mm bore with collar laid in trenches and jointed complete all as specified and as directed. |
| 60 | M&L Cement concrete 1:3:6 Type C-2 (using 40 mm graded stone aggregate) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 300 mm internal dia pipe complete all as specified and as directed. |
| 61 | M&L for cement concret 1:3:6 type C 1 (using 20mm graded aggregate) as in copping/surface channelincl weathering , slightly rounded or champer angleand throughting complete all as specified and directed. |
| 62 | M&L for forming fair finished drain or channel 50cm inner girth in cement motor, using extra cement includingform, moulds, mitred/stopped ends etc. complete all as specified and directed. |
| 63 | M&l for preparation of new steel Surfaces of any description, n.exc 10cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and as directed. |