| 1 | Safe carriage including Loading/Unloading & proper stacking of following store materials from Store Centre to site of work (Approx. distance 90 Km.) |
| 2 | S.T Pole 11 Mtr long |
| 3 | PCC Pole 8.5 /9.0 Mtr long |
| 4 | Top Channel 33 KV |
| 5 | Top Channel 11 KV |
| 6 | Stay Set Complete |
| 7 | Earthing Set Complete |
| 8 | 33/11 KV Poly. Disc Insulator |
| 9 | Dropper Channel 11/33KV |
| 10 | 33/11 KV Disc Fitting |
| 11 | 11 KV Pin Insulator |
| 12 | 11 KV Pin with Nut |
| 13 | Dog Conductor |
| 14 | 11 KV V TYPE X-Arm |
| 15 | ACSR Weasel Conductor |
| 16 | 33 KV XLPE Cable 3x300 mm2 |
| 17 | Cable Jointing kit Out door 3*300SQ. MM.33 KV |
| 18 | Cable Jointing kit ST THROUGHT 3*300SQ. MM.33 KV |
| 19 | 11 KV XLPE Cable 3x120 mm2 |
| 20 | Cable Jointing kit Out door 11 KV 3*120 SQ. MM |
| 21 | S/S BASE ANGLE |
| 22 | ABC (3X50+1X35+1X16) SQ. MM |
| 23 | AB CABLE (1X16+1X25) SQ. MM |
| 24 | LT Cable AL. 3.5x150 SQMM |
| 25 | M S Angle Braching with Nut, Bolts & Clamps65x65x6 mm |
| 26 | Danger Board |
| 27 | DEAD END CLAMP WITH EYE HOOK |
| 28 | DISTRIBUTION BOX 1- PHASE |
| 29 | SUSPENSION CLAMP WITH EYE HOOK |
| 30 | Stone Pad |
| 31 | Top & Dropper Chanel Clamp for STP |
| 32 | M.S. Nut & Bolt |
| 33 | M.S. Angle Bracing with Nut & Bolts (65x65x6) |
| 34 | Bracing Clamps 6.5 Inch Dia |
| 35 | Earth Wire Clamp with Nut Bolt |
| 36 | 11 KV X-Arm holding Clamp |
| 37 | L.T. Clamp |
| 38 | F-Clamp |
| 39 | HDPE Pipe 160/150 MM |
| 40 | Cable Root Marka 33/11 KV |
| 41 | GI Barbed Wire |
| 42 | Aluminium Paint |
| 43 | Red Oxcide Paint |
| 44 | GI Pipe(6 inch dia) |
| 45 | S/S BASE ANGLE CLAMP |
| 46 | ALUMINIUM LUG 150 SQ. MM |
| 47 | Holding Clamp for Cable with nut and bolt |
| 48 | Errection/Laying Work |
| 49 | Fabrication, erection of Single pole for 11 KV line on STP 11 mtr long Pole with fixing of necessary clamps & other accessories like 1 no. 11KV V-type Cross arm,1 no. F-Clamp. Itsgroutinginratio1:4:8,plinthing300mmaboveground level, painting of pole with one coat of red oxide & two coats ofenamelpaint(ISImark)&earthingofsupportasper RESSPONorms(Allgrouting&paintingmaterialshallbeprovided by the contractor.). |
| 50 | Fabrication, erection of Single pole for LT line on STP 11 mtr long Pole with fixing of necessary clamps & other accessories like L.T. Clamp, Earth wire Clamp etc. grouting in ratio 1:4:8,as per RESSPO Norms (All groutingmaterial shall be provided by the contractor.). |
| 51 | Fabrication, erection ofDouble pole for 11 KV line on ST POLE 11.0 mtr long Pole with fixing of necessary clamps & other accessories like 1 no. Top Channel etc.. Itsgroutinginratio1:4:8,plinthing300mmaboveground level, painting of pole with one coat of red oxide & two coats ofenamelpaint(ISImark)&earthingofsupportasper RESSPONorms(Allgrouting&paintingmaterialshallbeprovided by the contractor.). |
| 52 | Fabrication,erectionof33KVdoublepolestructureforend terminationson11MlongSTPolewithfixingofnecessary clamps&otheraccessorieslike1no.Topchannel 3200x125x65mm,MSAngleCrossBracing.Itsgroutingin ratio 1:4:8, plinthing 300 mm above ground level, painting of pole with one coat of redoxide & twocoats of enamel paint (ISI mark), earthing of support as per RESSPO Norms & one side cable expose for road crossing (All grouting material shallbe provided by the contractor.). |
| 53 | Fabrication, erection of double pole structure suitable for 25 to 63 KVA T/F on 8.5 M long pcc Pole with fixing of necessary clamps&otheraccessorieslike1no.Topchannel 2240x100X50mm,MSAngle.Itsgroutingin ratio 1:4:8, as per RESSPO Norms (All grouting material shall be provided by the contractor.) |
| 54 | Erection/Fixingforstaysetwithstaywireandclampasper RESSPO drawing including binding. Climbing, clamping, tightening and nozzeling etc. complete in all respect including its grouting in ratio 1:4:8 before back filling of the pits as per RESSPO, cement, brick, concrete ballast, sand and etc would beprovidedbythecontractorfor33/11KVsinglesupport, double pole and four pole structure. |
| 55 | Stringingandsaggingof11KVoverheadlineonACSR Weasel Conductor as per RESSPO Norms. |
| 56 | Layig of (double ckt) 33 kv xlpe cable 3*300 sq mm.in hdpe pipe 6 inch dia (160/150 mm)by trenchless technology method by horizontel drilling system |
| 57 | Hoisting of 3*300 sq. mm 33 kv xlpe cable on double pole with G.I. Pipe of size 6 inch dia including its jumpering complete withclampsnut &bolts |
| 58 | Layig of (double ckt) 11 kv xlpe cable 3*120 sq mm.in hdpe pipe 6 inch dia (160/150 mm)by trenchless technology method by horizontel drilling system |
| 59 | Hoisting of 3*120 sq. mm 11 kv xlpe cable on double pole with G.I. Pipe of size 6 inch dia including its jumpering complete withclampsnut &bolts |
| 60 | Layig of (double ckt) LT Cable AL. 3.5x150 sq mm.in hdpe pipe 6 inch dia (160/150 mm)by trenchless technology method by horizontel drilling system |
| 61 | Hoisting ofLT Cable AL. 3.5x150 sq mmon double pole with G.I. Pipe of size 6 inch dia including its jumpering complete withclampsnut &bolts |
| 62 | Fixing of danger board on each location& g.i berbed wire |
| 63 | Fixing of Cable Root Marka 33/11 KVon each location |
| 64 | Makng ofCable Jointing kit straight through 11 kv 3x120 mm2 |
| 65 | making ofCable Jointing kit Out door 3*300SQ. MM.33 KV |
| 66 | making of Cable Jointing kit Out door 11 KV 3*120 SQ. MM |
| 67 | fixing of 1- phase distribution box |
| 68 | earthing oftransformer & double pole |
| 69 | INSTALLATION OF V-TYPE CROSS ARM , GUARDINGANGLE & CLAMPS ETC. |
| 70 | Stringing and sagging of L.T. line on Cable LT abc(3*50+1*35+1*16) sq. mm as per RESSPO Norms. |
| 71 | Stringing and sagging of L.T. line on Cable LT abc(1*25+1*16) sq. mm as per RESSPO Norms. |
| 72 | DismantlingandremovingofFollowingLinesaspernorms complete in all respect - |
| 73 | Dismentlingof11 kvlinelenthappox. 320 Ckt. Mtr. along with accessories |
| 74 | Dismentling of33 kv linelenth appox.320 Ckt. Mtr. along with accessories |
| 75 | Dismentling of lt line Corrsing lenth appox. 400 Ckt. Mtr. along with accessories |
| 76 | Guarding of 11 KV Line |
| 77 | Recd. Back of33 kv line lenth appox. 320 Ckt. Mtr. |
| 78 | Recd. Back of11kv line lenth appox. 320 Ckt Mtr. |
| 79 | Recd. Back oflt line lenth appox. 350 Ckt. Mtr. |