| 1 | Maintenance of Electrical Installations at Coochbehar Govt. Engineering College premisesfor 4 nos Boys Hostel and Girls Hostel following persons fordutyrequired in Monthly basis.01 (one) No Skilled-alongwith 01 (one) no. Semi-skilled worker Round the clock operation (24 hours in a day) |
| 2 | Supply of following type materials for manetenance pourpose like- Wire,conduict, casing- capping, modular switches,Socket,Plug top,Starter and modular type box.MCB Enclosure 2-way |
| 3 | MCB Enclosure 4-way |
| 4 | 20 mm dia PVC Conduit |
| 5 | 25 mm dia PVC Conduit. |
| 6 | PVC casing-capping of size 20x12mm |
| 7 | PVC casing-capping of size 25x12mm |
| 8 | 32mm heavy gauge Polythene Pipe |
| 9 | 1.5 sq.mm \"FR\" stranded Copper Wire |
| 10 | 2.5 sqmm\"FR\" stranded Copper Wire |
| 11 | 4.0 sqmm \"FR\" stranded Copper wire |
| 12 | 6.0 sqmm \"FR\" stranded Copper wire |
| 13 | 10 sqmm \"FR\" stranded Copper wire |
| 14 | 2 module GI box |
| 15 | 4 module GI box |
| 16 | 6 module GI box |
| 17 | 2 row 12 module GI box |
| 18 | 2 row 18 module GI box |
| 19 | 2 module Cover plate |
| 20 | 3 module Cover plate |
| 21 | 4 module Cover plate |
| 22 | 6 module Cover plate |
| 23 | 2 row 12 module Cover plate |
| 24 | 2 row 18 module Cover plate |
| 25 | 6A Modular type Switch |
| 26 | 16A Modular type Switch |
| 27 | 6A Modular type 5 pin Plug Socket |
| 28 | 16A Modular type 6 pin Plug Socket |
| 29 | Modular socket type 2 module regulator |
| 30 | 20/25A starter |
| 31 | 20/25A plug top |
| 32 | 50mm GI pipe (ISI-Medium) |
| 33 | Red led / Zinc Oxied primar |
| 34 | Synthetic Enamel Paint Gr.II |
| 35 | RO primar |
| 36 | Alum. Paint |
| 37 | MS Clamp (380x25x3mm) |
| 38 | MS Clamp (380x40x6mm) |
| 39 | 200A - 400 A HRC Fuse |
| 40 | 100A-160A HRC Fuse |
| 41 | 32A-63 A HRC Fuse |
| 42 | Fixing only TPN switch fuse units in SheetSteel enclosure with HRC fuses on angle ironframe on wall for 32A to 400A |
| 43 | Supplying of 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / djustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection.(Make-Legrand)250 A MCCB-35 ka |
| 44 | Supplying of 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.(Make-Legrand)6-32A SP MCB |
| 45 | 6-32A DP MCB |
| 46 | 40A DP MCB |
| 47 | 63A TP MCB |
| 48 | 63A FP MCB |
| 49 | Supplyof 1.1 KV grade PVC/ Aluminium armouredcableof following sizes: 3.5 Core 150 sqmm |
| 50 | 3.5 Core 120 sqmm |
| 51 | 3.5 Core 50 sqmm |
| 52 | 3.5 Core 35 sqmm |
| 53 | 4 core 16sqmm |
| 54 | 2 core 6 sqmm |
| 55 | Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed |
| 56 | Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed |
| 57 | Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting |
| 58 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below.3.5 Core 150 sqmm |
| 59 | 3.5 Core 120 sqmm |
| 60 | 3.5 Core 50 sqmm |
| 61 | 3.5 Core 35 sqmm |
| 62 | 4 core 16sqmm |
| 63 | 2 core 6 sqmm |
| 64 | Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc. 3.5 Core 150 sqmm |
| 65 | 3.5 Core 120 sqmm |
| 66 | 3.5 Core 50 sqmm |
| 67 | 3.5 Core 35 sqmm |
| 68 | 4 core 16sqmm |
| 69 | 2 core 6 sqmm |
| 70 | Straigh through Jointing of cable of different size by compoundjointing kit including S&F ferrul, tapes and jointing materials(Brand approved by EIC)2 core 4-10 sqmm cable |
| 71 | 3½ / 4 core 10-16 sqmm cable |
| 72 | 3½ / 4 core 50 sqmm cable |
| 73 | 3½ / 4 core 25-35 sqmm cable |
| 74 | 3½ / 4 core 120-150 sqmm cable |
| 75 | 3½ / 4 core 240 sqmm cable |
| 76 | Repairing of existing ceiling fans,wall fans,exhaust fans ,including overhauling and winding of coils |
| 77 | Repairing of existing fire pumps and water supply pumps,including overhauling and winding of coils. |
| 78 | Repairing or replacement of existing internal and externallight fittings including lamp ,batten, driver and all other accessories. |
| 79 | Electronics LED driver of branded make for the following indoor/outdoor LED downlights/Street light luminaires.36 Watt LED Flat panel |
| 80 | 18 Watt LED downlights |
| 81 | 6 Watt LED downlights |
| 82 | 150 Watt LED Flood Light |
| 83 | 172 Watt LED Flood Light |
| 84 | supply of condenser/Capacitor for 900/1200/1400 mm ceiling fan. |
| 85 | Electrical Maintenance Charges for Two nos 750KVA indoor Dry type transformer and 1no 11KV VCB and 1600Amps 2 nos LT Pannel as per attached Terms & condition and as per direction of E-I-C. Providing 1 (one) no Highly Skilled in Day Shift (i.e. 10 am to 6.00 pm) with 01 (one) no. Skilled licensed Electrician Round the clock operation (24 hours in a day) at Sub-Station building for maintain the above electrical equipments.[Shift may be changed as per derection of E-I-C or as per requirement for emergency basis]. |
| 86 | Maintenance of Electrical Installations at Coochbehar Govt. Engineering College premisesforSubstation Building ,2nos. Workshop, Central facility and Library Building,Principal Quarters, Gymnecium including for Operation of the Diesel Generator set-200KVA and 160 KVA and 4 nos 6 HP Pump as Generator, Compound light and Pump operator around the whole campus following persons fordutyas requiredin one Shift ( i.e. 02.00 PM to 10.00 PM) Per Month.a)Skilled-01Noalongwith 1 (one) no. Semi-skilled worker Morning Shift( i.e. 06 AM to 02.00 PM) including1 (one) no. Semi-skilled worker Night Shift( i.e. 10.00 PM to 06.00 AM)[Shift may be changed as per derection of E-I-C or as per requirement for emergency basis]. |
| 87 | Weekly Checkup Cleaning, Tightening nuts, bolts with washers, Sockets, Glands, terminals of All types of SPN, TPN, VTPN DBs, Distribution Pannels and sub pannels of all buildings including Main LT Pannels installed in Sub-station and Clening and Checking of 2 nos 750 KVA Transformers, 11 KV 3 pannel VCB Pannel with expert Electrical Engineer on hire basis as a highly Skilled employee and 2nos Skilled and 2 nos Unskilled to be provided.(1 shift=8 hours) |
| 88 | Annual Maintenance Contract Service Charge (Eletro-Mechanical) for Kirloskar Make 160KVA Silent Generator SetESN No: F6.8618/1620041 Engine Model No: 6SL150TA G2 |
| 89 | Annual Maintenance Contract Service Charge (Eletro-Mechanical) for Kirloskar Make 200KVA Silent Generator SetESN No: 6H.8404/1620200 Engine Model No: 6K1080TA G2 |
| 90 | Inspection Fees of Manufracturer Authorised Sevice for 160 KVA and 200 KVA DG SET |
| 91 | Supply and fixing of Fule Filter Kit (Pack of 3) for 160 KVA and 200 KVA DG SET |
| 92 | Supply and fixing of LUB OIL (10Ltr Jar)of 160 KVA and 200 KVA DG SET |
| 93 | Supply and fixing of LUB OIL Filter Kit for 160 KVA and 200 KVA DG SET |
| 94 | Supply and fixing of AIR Filter Kit (Primary & Secondary) for 160 KVA and 200 KVA DG SET |
| 95 | Supply and fixing of Koolant of 160 KVA and 200 KVA DG SET |
| 96 | Supply of following type materials for manetenance pourpose like- Wire,conduict, casing- capping, modular switches,Socket,Plug top,Starter and modular type box. MCB Enclosure 2-way |
| 97 | MCB Enclosure 4-way |
| 98 | Multitune Call Bell (Anchor) |
| 99 | 20 mm dia PVC Conduit |
| 100 | 25 mm dia PVC Conduit. |
| 101 | PVC casing-capping of size 20x12mm |
| 102 | PVC casing-capping of size 25x12mm |
| 103 | 32mm heavy gauge Polythene Pipe |
| 104 | 1.5 sq.mm \"FR\" stranded Copper Wire |
| 105 | 2.5 sqmm\"FR\" stranded Copper Wire |
| 106 | 4.0 sqmm \"FR\" stranded Copper wire |
| 107 | 6.0 sqmm \"FR\" stranded Copper wire |
| 108 | 10 sqmm \"FR\" stranded Copper wire |
| 109 | 2 module GI box |
| 110 | 4 module GI box |
| 111 | 6 module GI box |
| 112 | 2 row 12 module GI box |
| 113 | 2 row 18 module GI box |
| 114 | 2 module Cover plate |
| 115 | 3 module Cover plate |
| 116 | 4 module Cover plate |
| 117 | 6 module Cover plate |
| 118 | 2 row 12 module Cover plate |
| 119 | 2 row 18 module Cover plate |
| 120 | 6A Modular type Switch |
| 121 | 16A Modular type Switch |
| 122 | 6A Modular type 5 pin Plug Socket |
| 123 | 16A Modular type 6 pin Plug Socket |
| 124 | Modular socket type 2 module regulator |
| 125 | 20/25A starter |
| 126 | 20/25A plug top |
| 127 | 50mm GI pipe (ISI-Medium) |
| 128 | Red led / Zinc Oxied primar |
| 129 | Synthetic Enamel Paint Gr.II |
| 130 | RO primar |
| 131 | Alum. Paint |
| 132 | MS Clamp (380x25x3mm) |
| 133 | MS Clamp (380x40x6mm) |
| 134 | 200A - 400 A HRC Fuse |
| 135 | 100A-160A HRC Fuse |
| 136 | 32A-63 A HRC Fuse |
| 137 | Fixing only TPN switch fuse units in SheetSteel enclosure with HRC fuses on angle ironframe on wall for 32A to 400A |
| 138 | Supplying of 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / djustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection.(Make-Legrand)250 A MCCB-35 ka |
| 139 | Supplying of 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.(Make-Legrand)6-32A SP MCB |
| 140 | 6-32A DP MCB |
| 141 | 40A DP MCB |
| 142 | 63A TP MCB |
| 143 | 63A FP MCB |
| 144 | 100A FP MCB |
| 145 | 125A FP MCB |
| 146 | Supplyof 1.1 KV grade PVC/ Aluminium armouredcableof following sizes:3.5 Core 240 sqmm |
| 147 | 3.5 Core 150 sqmm |
| 148 | 3.5 Core 120 sqmm |
| 149 | 3.5 Core 95 sqmm |
| 150 | 3.5 Core 50 sqmm |
| 151 | 3.5 Core 35 sqmm |
| 152 | 3.5 Core 25 sqmm |
| 153 | 4 core 16sqmm |
| 154 | 4 core 10 sqmm |
| 155 | 2 core 10sqmm |
| 156 | 2 core 6 sqmm |
| 157 | Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed |
| 158 | Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed |
| 159 | Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting |
| 160 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below.3.5 Core 240 sqmm |
| 161 | 3.5 Core 150 sqmm |
| 162 | 3.5 Core 120 sqmm |
| 163 | 3.5 Core 95 sqmm |
| 164 | 3.5 Core 50 sqmm |
| 165 | 3.5 Core 35 sqmm |
| 166 | 3.5 Core 25 sqmm |
| 167 | 4 core 16sqmm |
| 168 | 4 core 10 sqmm |
| 169 | 2 core 10sqmm |
| 170 | 2 core 6 sqmm |
| 171 | Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc.3.5 Core 240 sqmm |
| 172 | 3.5 Core 150 sqmm |
| 173 | 3.5 Core 120 sqmm |
| 174 | 3.5 Core 95 sqmm |
| 175 | 3.5 Core 50 sqmm |
| 176 | 3.5 Core 35 sqmm |
| 177 | 3.5 Core 25 sqmm |
| 178 | 4 core 16sqmm |
| 179 | 4 core 10 sqmm |
| 180 | 2 core 10sqmm |
| 181 | 2 core 6 sqmm |
| 182 | Straigh through Jointing of cable of different size by compoundjointing kit including S&F ferrul, tapes and jointing materials(Brand approved by EIC)2 core 4-10 sqmm cable |
| 183 | 3½ / 4 core 10-16 sqmm cable |
| 184 | 3½ / 4 core 25-35 sqmm cable |
| 185 | 3½ / 4 core 50 sqmm cable |
| 186 | 3½ / 4 core 95 sqmm cable |
| 187 | 3½ / 4 core 120-150 sqmm cable |
| 188 | 3½ / 4 core 240 sqmm cable |
| 189 | Repairing of existing ceiling fans,wall fans,exhaust fans ,including overhauling and winding of coils |
| 190 | Repairing of existing fire pumps and water supply pumps,including overhauling and winding of coils. |
| 191 | Repairing or replacement of existing internal and externallight fittings including lamp ,batten, driver and all other accessories. |
| 192 | Electronics LED driver of branded make for the following indoor/outdoor LED downlights/Street light luminaires.36 Watt LED Flat panel |
| 193 | 18 Watt LED downlights |
| 194 | 6 Watt LED downlights |
| 195 | 150 Watt LED Flood Light |
| 196 | 172 Watt LED Flood Light |
| 197 | supply of condenser/Capacitor for 900/1200/1400 mm ceiling fan. |
| 198 | Maintenance of Electrical Installations at Coochbehar Govt. Engineering College premisesfor Academic and Administrative Building following persons fordutyrequired in Monthly basis.01 (one) No Highly Skilled and 01 (one) No Skilled-alongwith 01 (one) no. Semi-skilled worker. |
| 199 | Annual Comprehensive Maintenance Charges for attending2.0 TR Wall Mounted Split type Air-Conditioning Machineswith cordless remote at Administrative and Academic Building of Coochbehar government Engineering College with Co\"s own tools and tackles and devices as per terms and conditions enclosed. |
| 200 | Preventive and corrective comprehensive annual Maintenance of-A. Entire Fire Detection system including Fire detection pannel, i) Fire detectors -208 nos,ii) MCP- 22 nos, iii) Hooters- 23 nos etc.with Non comprehensive annual Maintenance of-B) Entire fire detection system including i) 55HP Main pump with motor 3ph.415V,50Hz. ii) 7.5HP Jockey pump with motor 3ph,415V,50Hz. iii)Diesel Pump. iv)Total Hydrant line of 80mm to 150mm dia from Underground Reservour to Academic Building and Administrative Building with hydrant post incluiding all valves and other all accessories related to fire fighting system at Coochbehar Govt. Engineering College premises considering two visit per month and as when required during troble/ fault condition. |
| 201 | Supply of following type materials for manetenance pourpose like- Wire,conduict, casing- capping, modular switches,Socket,Plug top,Starter and modular type box.MCB Enclosure 2-way |
| 202 | MCB Enclosure 4-way |
| 203 | 20 mm dia PVC Conduit |
| 204 | 25 mm dia PVC Conduit. |
| 205 | PVC casing-capping of size 20x12mm |
| 206 | PVC casing-capping of size 25x12mm |
| 207 | 32mm heavy gauge Polythene Pipe |
| 208 | 1.5 sq.mm \"FR\" stranded Copper Wire |
| 209 | 2.5 sqmm\"FR\" stranded Copper Wire |
| 210 | 4.0 sqmm \"FR\" stranded Copper wire |
| 211 | 6.0 sqmm \"FR\" stranded Copper wire |
| 212 | 10 sqmm \"FR\" stranded Copper wire |
| 213 | 2 module GI box |
| 214 | 4 module GI box |
| 215 | 6 module GI box |
| 216 | 2 row 12 module GI box |
| 217 | 2 row 18 module GI box |
| 218 | 2 module Cover plate |
| 219 | 3 module Cover plate |
| 220 | 4 module Cover plate |
| 221 | 6 module Cover plate |
| 222 | 2 row 12 module Cover plate |
| 223 | 2 row 18 module Cover plate |
| 224 | 6A Modular type Switch |
| 225 | 16A Modular type Switch |
| 226 | 6A Modular type 5 pin Plug Socket |
| 227 | 16A Modular type 6 pin Plug Socket |
| 228 | Modular socket type 2 module regulator |
| 229 | 20/25A starter |
| 230 | 20/25A plug top |
| 231 | 50mm GI pipe (ISI-Medium) |
| 232 | Red led / Zinc Oxied primar |
| 233 | Synthetic Enamel Paint Gr.II |
| 234 | RO primar |
| 235 | Alum. Paint |
| 236 | MS Clamp (380x25x3mm) |
| 237 | MS Clamp (380x40x6mm) |
| 238 | 200A - 400 A HRC Fuse |
| 239 | 100A-160A HRC Fuse |
| 240 | 32A-63 A HRC Fuse |
| 241 | Fixing only TPN switch fuse units in SheetSteel enclosure with HRC fuses on angle ironframe on wall for 32A to 400A |
| 242 | Supplying of 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / djustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection.(Make-Legrand)250 A MCCB-35 ka |
| 243 | Supplying of 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.(Make-Legrand)6-32A SP MCB |
| 244 | 6-32A DP MCB |
| 245 | 40A DP MCB |
| 246 | 63A TP MCB |
| 247 | 63A FP MCB |
| 248 | 100A FP MCB |
| 249 | 125A FP MCB |
| 250 | Supplyof 1.1 KV grade PVC/ Aluminium armouredcableof following sizes:1 Core 400 sqmm |
| 251 | 3.5 Core 300 sqmm |
| 252 | 3.5 Core 240 sqmm |
| 253 | 3.5 Core 95 sqmm |
| 254 | 3.5 Core 25 sqmm |
| 255 | 4 core 10 sqmm |
| 256 | 2 core 10sqmm |
| 257 | 3.5 Core 150 sqmm |
| 258 | 3.5 Core 120 sqmm |
| 259 | 3.5 Core 50 sqmm |
| 260 | 3.5 Core 35 sqmm |
| 261 | 4 core 16sqmm |
| 262 | 2 core 6 sqmm |
| 263 | Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed |
| 264 | Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed |
| 265 | Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting |
| 266 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below.1 Core 400 sqmm |
| 267 | 3.5 Core 300 sqmm |
| 268 | 3.5 Core 240 sqmm |
| 269 | 3.5 Core 95 sqmm |
| 270 | 3.5 Core 25 sqmm |
| 271 | 4 core 10 sqmm |
| 272 | 2 core 10sqmm |
| 273 | 3.5 Core 150 sqmm |
| 274 | 3.5 Core 120 sqmm |
| 275 | 3.5 Core 50 sqmm |
| 276 | 3.5 Core 35 sqmm |
| 277 | 4 core 16sqmm |
| 278 | 2 core 6 sqmm |
| 279 | Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc.1 Core 400 sqmm |
| 280 | 3.5 Core 300 sqmm |
| 281 | 3.5 Core 240 sqmm |
| 282 | 3.5 Core 95 sqmm |
| 283 | 3.5 Core 25 sqmm |
| 284 | 4 core 10 sqmm |
| 285 | 2 core 10sqmm |
| 286 | 3.5 Core 150 sqmm |
| 287 | 3.5 Core 120 sqmm |
| 288 | 3.5 Core 50 sqmm |
| 289 | 3.5 Core 35 sqmm |
| 290 | 4 core 16sqmm |
| 291 | 2 core 6 sqmm |
| 292 | Straigh through Jointing of cable of different size by compoundjointing kit including S&F ferrul, tapes and jointing materials(Brand approved by EIC)2 core 4-10 sqmm cable |
| 293 | 3½ / 4 core 10-16 sqmm cable |
| 294 | 3½ / 4 core 50 sqmm cable |
| 295 | 3½ / 4 core 25-35 sqmm cable |
| 296 | 3½ / 4 core 120-150 sqmm cable |
| 297 | 3½ / 4 core 240 sqmm cable |
| 298 | Repairing of existing ceiling fans,wall fans,exhaust fans ,including overhauling and winding of coils |
| 299 | Repairing of existing fire pumps and water supply pumps,including overhauling and winding of coils. |
| 300 | Repairing or replacement of existing internal and externallight fittings including lamp ,batten, driver and all other accessories. |
| 301 | Electronics LED driver of branded make for the following indoor/outdoor LED downlights/Street light luminaires.36 Watt LED Flat panel |
| 302 | 18 Watt LED downlights |
| 303 | 6 Watt LED downlights |
| 304 | 150 Watt LED Flood Light |
| 305 | 172 Watt LED Flood Light |
| 306 | supply of condenser/Capacitor for 900/1200/1400 mm ceiling fan. |
| 307 | Providing, laying, testing & commissioning of \"C\" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame andpainting with two or more coats of synthetic enamel paint of required shade complete as required : 80mm dia MS Pipe |
| 308 | 100mm dia MS Pipe |
| 309 | 150mm dia MS Pipe |
| 310 | Basic cost of 4 mm thick Anti Corrosive Pipe ProtectionBituminous Tape, |
| 311 | Basic cost of anticorrosive Black paint |
| 312 | Single head gunmetal hydrant valve |
| 313 | Gunmetal short branch pipe |
| 314 | 150mm dia butterfly valve |
| 315 | 100mm dia butterfly valve |
| 316 | 80mm dia butterfly valve |
| 317 | NON RETURN VALVE cast Iron double flange as per IS/5312 PN 1.6 rating complete with Bronze body & wedge Stainless Steel spindle, Gland packing, Rubber gasket 150mm dia Non Return Valve |
| 318 | 100 mm dia Non Return Valve |
| 319 | 80mm dia Non Return Valve |
| 320 | Cost of 150 mm dia Flanges |
| 321 | Cost of 100 mm dia Flanges |
| 322 | Cost of 80 mm dia Flanges |
| 323 | Cost of 8 Nos. Nut Bolt fastner & packing gaskets |
| 324 | Cost of welding rod |
| 325 | Repairing of 3 nosOTIS Make 8 Passenger lift for make in working Condition including the following materials -a) 3 nos Emergency light, b) 2 nos Encoder, c) 1 no.LVPB PCB Power supply 230V AC, d) 1 no. Ultra Drive UD402[ACD5], e) 3 nos ARD Battery. |
| 326 | Annual Maintenance Contract Service Charge for OTIS Make 2 Nos 8 Passenger Lift installed at Academic Building and 1 No. Passenger Lift installed at Administrative Bulilding in the Premises of Coochbehar Government Engineering college. |