| 1 | M & L Point wiring using approved colour coding as per IS, with stranded copper conductor 1.5 sqmm (nominal area), single core, flame retardant low smoke(FRLS), PVC insulated and unsheathed cable 1100 volts grade, ISI 694 marked TEC and FIA approved in and including PVC casing and caping and its fittings ISI marked, with metal flush boxes suitable for modular/normal switch/sockets etc with earth dolly duly painted with two coats of anti corrosive paint over a coat of red oxide primer internally, incl covered with suitable module cover plate with frame including flame retardant low smoke (FRLS) PVC insulated unsheathed stranded copper conductor 1.5 sqmm (nominal are) single core cable as earth continuity conductor to common earth and connected to earth dolly for One light point controlled by one switch complete all as specified and directed. |
| 2 | Ditto -- all as per above item No 01 but One Fan point controlled by one switch and one regulator. |
| 3 | Ditto -- all as per above item No 01 but One socket out let 5 pin 5 Amp on independent board One socket out let 5 pin 5 Amp on independent board. |
| 4 | Ditto -- all as per above item No 01 but One socket out let 5 pin 5 Amp on same board. |
| 5 | Ditto -- all as per above item No 01 but but using 4.0 Sqmm cable for one 15 A socket outlet point with 2.5 Sq mm PVC insulated, unsheathed copper conductor cable as earth continuity conductor. |
| 6 | Supply and fix modular switch 1 way 6A, 1 module complete all as specified and directed. |
| 7 | S & F Modular socket outlet 1 way 6 Amps 2/3 pins combined, 2 module complete all as specified and directed. |
| 8 | Supply and fix modular switch 1 way 16A, 1 module complete all as specified and directed. |
| 9 | S & F Modular socket outlet 1 way 6/16 Amps -2/3 pins combined, 2 module complete all as specified and directed. |
| 10 | S & F modular fan regulator, 120 watts, ISI marked, 2 module step type complete all as specified and directed. |
| 11 | S & F White cover plate with frame, 3 module including metal flush box 3 module complete all as specified and directed. |
| 12 | S & F White cover plate with frame, 4 module including metal flush box 4 module complete all as specified and directed. |
| 13 | S & F White cover plate with frame, 6 module including metal flush box 6 module complete all as specified and directed. |
| 14 | S & F White cover plate with frame, 8 module complete all as specified and directed. |
| 15 | S & F modular metal flush box 8 module complete all as specified and directed. |
| 16 | S & F for ceiling rose 3 phase/PVC/polycarbonated isolated body.Note: for item No 1 to 16 : Water resistant IP 66 type modular, boards, switches sockets of Approved make to be provided. |
| 17 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.Note :- Hanging arrangement alongwith anchor fastner, hook and fan box shall also included in the quoted rates. |
| 18 | Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 19 | Supply and fix building security light of35/36 watt IP 65 watt, LED die casting aluminium with LED street optic lenses, efficacy of skyline plus is upto 120 lm/w, with pea nut lenses LED type with bracket arrangement complete all as required and directed. |
| 20 | S & F for MCB DB\"s 4 Way TPN, 415 volts for mounting MCBs/RCBO\"s ELCB\"s etc. as per IS specification of factory made fabricated out of CRCA sheet 1.2 mm thick powder coated fitted with DIN Channel neutral link and 200 Amps rated bus bar.The DB\"s shall double door type . Inner door fixed on spring loaded hinges with locking arrangement & outer door openable hinged with locking arrangement having IP-43 protection complete all as specified and directed. |
| 21 | Supply and fixing 415V 10KA \"B\" curve MCB TPN 63 Amps complete with connection testing and commissioning complete all as specified and directed. |
| 22 | S & F for MCB SP 6-32 Amps 240 Volts C Curve 10 KA complete all as specified and directed. |
| 23 | M & L for Earthing complete with galvanised steel earth plate electrode of size 60cm X 60cm X 6mm buried directly in ground (earth pit not less than 2.25 metres deep below the normal ground level) with top edge of the plate not less than 1.5m below normal GL connected to GI earth wire 4 mm dia by means of GI bolts, nuts, check nuts and washers and earth strip protected by 25 mm dia GI pipe medium grade and connected to main distribution board/earthing test point all as shown on electrical plate No.3 of SSR Part I and all as specified including testing on completion.Notes: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix, type B1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe for earth lead upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II and also refer Plate No-03.Earth strip and protection pipe beyond 7.5m shall be measured and paid separately. Note :- Earthing will be redone if desied erath result not found during testing of the same at site. |
| 24 | Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 4 core.from walls, poles, trenches all as per directed and specified by Engr-in-charge |
| 25 | Excavation in trenches in soft/loose of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables complete all as specified and directed. |
| 26 | Returning filling, in including spreading, leveling, watering and well ramming in layers not exc 25 cm each complete all as required. |
| 27 | Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 28 | M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretchingand testing the cable complete all as specified and directed. Note : Punned down thickness shall be measured and paid. |
| 29 | Supplying and laying reinfirced precast concrete cable cover class LV , type 1 ,size flat size 250 x 150 x 40 mm all asper required and directed . |
| 30 | Supply and laying of light grade galvanised tube 40 mm bore with all fittings and fixed to walls / ceiling or laid in floor, pole or laid in trenches and road crossings including sealing ends with hession cloth impregnated with bituminous compound in ground and with teak wood bushes for ends fixed with walls / poles complete all as specified and as directed. |
| 31 | M & L for Sub main wiring with approved colour coding as per IS with two runs of single core PVC insulated cable FRLS with Multi Strand copper conductor of size 4 Sq. mm and drawing into PVC condutit/casing and capping including one run of PVC insulated 4 sqmm stranded copper conductor earth wire complete all as specified and directed. |
| 32 | Supply and fixing LED Bollard lights10W (warm white/ white),IP 65 having cylindrical/square body suitable for outdoor lighting, walkways complete all as specifeid and directed by Engr-in-Charge.Make : Havells model mountled or equivalent model from approved list. |
| 33 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as specifeid and directed. |
| 34 | M & L for Point wiring using approved colour coding as per IS, with stranded copper conductor 1.5 sqmm (nominal area), single core, flame retardant low smoke(FRLS), PVC insulated and unsheathed cable 1100 volts grade, ISI 694 marked TEC and FIA approved in and including PVC concealed conduit and its fittings ISI marked, with mild steel sunken boxes suitable for modular/normal switch/sockets etc with earth dolly duly painted with two coats of anti corrosive paint over a coat of red oxide primer internally, incl covered with suitable module cover plate with frame including flame retardant low smoke (FRLS) PVC insulated unsheathed stranded copper conductor 1.5 sqmm (nominal are) single core cable as earth continuity conductor to common earth and connected to earth dolly for One light point controlled by one switch complete all as specified. |
| 35 | Ditto -- all as per above item No 34 but One Fan point controlled by one switch and one regulator. |
| 36 | Ditto -- all as per above item No 34 but One socket out let 5 pin 5 Amp on independent board. |
| 37 | Ditto -- all as per above item No 34 but One socket out let 5 pin 5 Amp on same board. |
| 38 | Ditto -- all as per above item No 34 but using 4.0 Sqmm cable for one 15 A socket outlet point with 2.5 Sq mm PVC insulated, unsheathed copper conductor cable as earth continuity conductor. |
| 39 | Supply and fix modular switch 1 way 6A, 1 module complete all as specifeid and directed. |
| 40 | S & F Modular socket outlet 1 way 6 Amps 2/3 pins combined, 2 module complete all as specifeid and directed. |
| 41 | Supply and fix modular switch 1 way 16A, 1 module complete all as specifeid and directed. |
| 42 | S & F Modular socket outlet 1 way 6/16 Amps -2/3 pins combined, 2 module complete all as specifeid and directed. |
| 43 | S & F modular fan regulator, 120 watts, ISI marked, 2 module step type complete all as specifeid and directed. |
| 44 | S & F White cover plate with frame, 3 module including metal flush box 3 module complete all as specifeid and directed. |
| 45 | S & F White cover plate with frame, 4 module including metal flush box 4 module complete all as specified and directed. |
| 46 | S & F White cover plate with frame, 6 module including metal flush box 6 module complete all as specifeid and directed. |
| 47 | S & F White cover plate with frame, 8 module complete all as specifeid and directed. |
| 48 | S & F modular metal flush box 8 module complete all as specifeid and directed. |
| 49 | S & F for ceiling rose 3 phase/PVC/polycarbonated isolated body complete all as specifeid and directed. |
| 50 | S & F for power unit mini modular MCB box with mini MCB 20 Amps SP with ISI plug top with box for connecting AC\"s upto 2 ton complete all as specified and directed. Make Ancho UNO Code No 98488 or equivalent model from approved list. |
| 51 | Supply and fixing LED lights fitting 1x 18W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specifeid and directed. |
| 52 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specifeid and directed. |
| 53 | Supply and fixing round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specifeid and directed. |
| 54 | S & F for MCB DB\"s 12 Way SPN, 240 volts for mounting MCBs/RCBO\"s ELCB\"s etc. as per IS specification of factory made fabricated out of CRCA sheet 1.2 mm thick powder coated fitted with DIN Channel neutral link and 200 Amps rated bus bar.The DB\"s shall double door type . Inner door fixed on spring loaded hinges with locking arrangement & outer door openable hinged with locking arrangement having IP-43 protection complete all as specifeid and directed. |
| 55 | Supply and fixing 415V 10KA \"C\" curve MCCB of 100 Amps TPN, 16 KA and current carrying capacity in the DB complete with connection testing and commissioning. |
| 56 | S & F for MCB SPN 63 Amps 240 Volts C Curve 10 KA complete all as specifeid and directed. |
| 57 | S & F for MCB SP 40- 63 Amps 240 Volts C Curve 10 KA complete all as specifeid and directed. |
| 58 | M & L for Sub main wiring with approved colour coding as per IS with two runs of single core PVC insulated cable FRLS with Multi Strand copper conductor of size 6 Sq. mm and drawing into PVC casing and capping including one run of PVC insulated 6 sqmm stranded copper conductor earth wire complete all as directed. |
| 59 | Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core.from walls, poles, trenches all as per directed and specified by Engr-in-charge |
| 60 | Supply and fix GI strip 32 x 6 mm with all connected accessoriesfor roofconductors and down conductors above ground complete all as specified and as directed. |
| 61 | Supply and fix Aluminium strip 25 x 3.15 mm with saddles and fixing screw etc for roofconductors and down conductors above ground with all connected accessories complete all as specified and as directed. |
| 62 | M & L of Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw suitable for lightning arrestor complete all as specified and as directed. |
| 63 | Supply and fix of Copper rod 12.5mm diameter and 2.5 metres length suitable for conventional spike lightning arrester install on roof/ pole with nuts and bolt and requirment of all as per site with all connected accessories complete all as specified and as directed. |
| 64 | Total contract sum shall be calculated after deduction of schedule of credit amount of Rs. 3,675.00 |