| 1 | Taking down ceiling fan of any sweep of any make by disconnecting electric connection from ceiling rose, for carrying out necessary repair such as replacement of old condensers/ rubber bushes/ bearing/ flexiblecopper cable of suitable size including overhauling by carrying out repair such as applying grease to metal parts, rewinding of burnt coil and replacement of suitable size of cotter/split pin as required,reassembling and re-fixing in original/ new position including necessary connectionwiththree core flexible copper wire of suitable length from ceiling rose to connector of fan andtesting complete all as specified and as directed.Notes :- (i) Rewinding of fans and spares required for replacement shall be measured and paid seperately under respective item of BOQ as considered therein.(ii) Ratequoted is deemed to be inclusive of new flexible copper wireof suitable size as required at site. |
| 2 | Taking down exhaust fan/wall mounting fan heavy duty of 300 mm or 380 mm or 450 mm sweep by disconnecting from the ceiling rose, carrying out necessay repair such as replacement of capacitor/ bearings/ flexible copper cable of suitable size including overhauling by carrying out repair such as applying grease to metal parts, rewinding of burnt coil and replacement of suitable size split pin as required, reassembling and re-fixing in original position, fixing of louvers/wire mesh including necessary connection with three coreflexible copper wire and testing complete all as specified and as directed Notes:- (i) Rewinding of exhaust fans and spares required for replacement shall be measured and paid seperately underrespective item of BOQ as considered therein.(ii)Ratequoted is deemed to be inclusive of new flexible copper wireof suitable size as required at site. |
| 3 | S&F in replacement of capacitor/ condenser of ceiling fan , 2.5 mfd of approved make complete all as specified and as directed. |
| 4 | S&F in replacement ofcapacitor /condenser ofexhaust fan4 mfd of approved makecomplete all as specified and as directed. |
| 5 | S&F in replacement of louvers suitable for 450 mm sweep exhaust fan complete all as specified and as directed |
| 6 | S&F in replacement of louvers suitable for 380/300 mm sweep exhaust fan complete all as specified and as directed |
| 7 | M&L forrewinding of ceiling fan motor of1200 mm sweep of any makewith super enameled copper wire of existinggauge including replacement of insulating materials such as laminated lethroid paper, sleeves, necessary varnishing with golden colour varnish, greasing the bearings, replacement of missing / worn out nuts, bolts and washers, split pins etc complete all as specified and as directed |
| 8 | M&L for rewinding ofExhaust fan motor of 450 mm sweep of any makewith super enaneled copper wire of existing gauge including replacement of insulating materials such as laminated lethroid paper, sleeves, necessary varnishing with varnish , greasing thebearing, replacement of missing/worn out nuts, bolts and washers, split pins etc complete all as specified and as directed. |
| 9 | Ditto all as per above item but for Exhaust fan motor of 380 mm sweep of any make complete all as specified and as directed. |
| 10 | Ditto all as per above item but for exhaust fan/wall mounting fan motor of 300 mm sweep of any make complete all as specified and as directed. |
| 11 | M&L forspray painting with white synthetic enamel paint including preparation of old surface of the ceiling fan of any make/model/sweep, filling cavities with filler after cleaning dust complete all as specified and as directed. |
| 12 | Ditto all as per above item but for exhaust fan of 450 mm sweep of any make and model with grey colour synthetic enamel paintcomplete all as specified and as directed. |
| 13 | Ditto all as per above item but for exhaust fan of 380 mm sweep of any make and model with grey coloursynthetic enamel paint complete all as specified and as directed. |
| 14 | Ditto all as per above item but for exhaust fan of 300 mm sweep of any make and model with grey coloursynthetic enamel paint complete all as specified and as directed. |
| 15 | S&F in replacement of ball bearing 6201 / 6202 / 6203including metal filling, machining if required complete all as specified and as directed. |
| 16 | S&F in replacement of canopy (upper and lower) to match the ceiling fan of existingmake/model as required at site complete all as specified and as directed |
| 17 | S&F in replacement of gun metal bush, suitable for ceiling fan of any make and sweepcomplete all as specified and as directed. |
| 18 | S&F in replacement ofclamp with nuts , bolts and rubber bush suitable for ceiling fan of any sweep and make as per existing size and shape complete all as specified and as directed |
| 19 | S&F in replacement of 15mm bore galvanised iron pipemedium grade as indown rod , 300mm long with nuts, bolts , washers and suitable pin for hanging of ceiling fan of any sweep and makecomplete all as specified and as directed. |
| 20 | S&F in replacement of 15mm boregalvanised iron pipe medium grade as indown rod, 600mm long with nuts, bolts, washer and suitable pin for hanging of ceiling fan of any sweep and makecomplete all as specified and as directed.M |
| 21 | S&F inreplacement of shaft suitable for 1200/1400 mm sweep ceiling fan complete all as specified and as directed. |
| 22 | Taking down the storage type water heater of any type & size by disconnecting electric connection for carrying out necessary repair such as cleaning of inner water tank, removing scales,connecting flexible three core copper cable of size 2.5 sqmm and re-fixing in original position includingtesting complete all as specified and as directed.Notes :-Spares parts required for repalcement shall be measured and paid seperately under respective item of BOQ as considered therein. |
| 23 | M&L for spray painting with white synthetic enamel paint includingpreparation of old surface of geyser of any make/model complete all as specified and as directed. |
| 24 | S&F inreplacement DP switch , 32 Amps, 230 volts with indicating lamp complete all as specified and as directed. |
| 25 | Supply and fixin replacement indicating lamp for geyser, complete all as specified and as directed |
| 26 | S&F inreplacement 3 pin plug top of 15 Amp, completeall as specified and as directed. |
| 27 | S&F in replacement heating element 2000 Watt capacity, 230 Volts,round / triangle base suitable for existing water heater of 50 litre capacity complete all as specified and as directed. |
| 28 | S&Fin replacement heating element 1500 Watt capacity, 230 Volts,round / triangle base suitable for existing water heater of 25 litre capacity complete all as specified and as directed. |
| 29 | S&F in replacement 15mm dia PVC flexible connections (heavy duty) 450mm long with two Nos brass nuts with washer at both ends complete all as specified and as directedMake :- Prayg / Commandar / Prince/Polytuff |
| 30 | S&F inreplacement 15mm dia bore galvanised ironpipe medium gradewith all fittings such as bends, elbow,tees,reducer, diminishing piece, caps, plugs and unions etc. complete all as specified and as directed. |
| 31 | S&F inreplacement 15mm dia bore stop valvescast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. |
| 32 | S&F inreplacement of thermostat of capacity 1500/2000Watt for geyser of any capacity complete all as specified and as directed. |
| 33 | S&F in repairs Switch piano , flush type single pole, one way 5 Amp complete all as specified and as directed. |
| 34 | S&F in repairs ceiling rose , three phase PVC/ polycarbonate, isolated body complete all as specified and as directed. |
| 35 | S&F in repairs five stepped type electronicfanregulator, flush type on existing laminated sheet for ceiling fan complete all as specified and as directed. |
| 36 | S&F in replacement blade for ceiling fanof size 1200/1400 mm sweep (as per sample) to match with ceiling fan colour complete all as specified and as directed. |
| 37 | S&Fin replacement of geyser tank of 50 ltr capacity complete all as specified and as directed |
| 38 | S&F in replacement Capacitor plastic clamp for ceiling Fan, Complete all as Specified and as directed |
| 39 | S&F in replacementBLDC Motor Kit complete (Kit contents one MCU board, one power train board, one BLDC motor, one motor mount board, one MCU kit and one 12V, 5 Amp universal input power adaptor) for BLDC ceiling fan complete all as specified and as directed |