| 1 | \"Notes: (i) Please refer Schedule \"A\" Notes of tender documents. |
| 2 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. all as specified and directed. |
| 3 | M&L for point wiring with1.50 sqmm in copper conductor cable ( multistrand) FRLSH single core PVC insulated cable in and including PVCconcealed conduit( ISI Marked) of heavy dulywith all accessories ie PVC gutties etc terminated insunken/pressed metal flush box and white modular cover plate with frame for mounting of switches /sockets/ fan regulators etc and continuous earth wire 1.5 Sqmm copper cable PVC insulated FRLSH controlled by one switch for one light/fan/sockets point/all as specified and directed in ceiling Portionsurface conduit wiringto be done.Note : i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB\"s in DB\"s without any extra cost ii) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth. (iii) Necessity cutting chasing where ever required shall be part of job & making good the disturbed surfaces shall be part of job. |
| 4 | All as per item No 3 above, but for one 3/5 pinsocket outlet 5 Amp on the same board with other switches complete all as specified and directed. |
| 5 | All as per item No 3 above, but for one 3/5 pin socket outlet 5 Amp on independent board complete all as specified and directed. |
| 6 | All as per serial item No 3 here-in-before , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded)PVC insulated and unsheating electric cable 1100 volts(ISI Marked) including PVC insulated and unsheathedelectric cable 1100 volts 2.5 Sqmm copper stranded conductor ascontinuous earthwire connected to common earth dolly complete all as specified anddirected. |
| 7 | S&F in replacement modularswitch1 way, 6 Amps, 1 module complete all as specified and directed. |
| 8 | S&F in replacement modulartype,switch 1 way, 16 Amps, 1 module complete all as specified and directed. |
| 9 | S&F in replacement modulartype,Bell push1 way, 6 Amps, 1 module complete all as specified and directed. |
| 10 | S&F in replacement modular type,socket 5 pin 6 Amps, 2/3 PIin combined 2 module complete all as specified and directed. |
| 11 | S&Fin replacement modularsocket 5 pin 6/16 Amps, 2/3 Pin combined 2 module complete all as specified and directed. |
| 12 | S&Fmodular Fan regulator step type, 120 watts, 1 module complete all as specified and directed. |
| 13 | S&Fin replacment of Modular MS chromium White Cover Plate with frame and metal flush box 1 module inl all accessories complete all as specified and directed. |
| 14 | S&Fin replacment of Modular MS chromium White Cover Plate with frame and metal flush box 2 module inl all accessories complete all as specified and directed. |
| 15 | S&Fin replacment of Modular MS chromium White Cover Plate with frame and metal flush box 3 module inl all accessories complete all as specified and directed. |
| 16 | S&Fin replacment of Modular MS chromium White Cover Plate with frame and metal flush box 4 module inl all accessories complete all as specified and directed. |
| 17 | S&Fin replacment of Modular MS chromium White Cover Plate with frame and metal flush box 6 module inl all accessories complete all as specified and directed. |
| 18 | S&Fin replacment of switch piano, flush button type, singlepole , one way 6 Amps complete all as specified and directed. |
| 19 | S&F in replacment of switch piano, flush button type, singlepole , one way 16 Amps complete all as specified and directed. |
| 20 | S&F in replacment of socket outlet 3 pin, 6 Amps , flush type complete all as specified complete all as specified and directed. |
| 21 | S&F in replacment of socket outlet 2-in-1, 3 pin , 6 and 16 Amps, flush type complete all as specified complete all as specified and directed. |
| 22 | S&F in replacment of electronic fan regulator piano type (5 Step up) 280 Volts suitable for ceiling fan complete all as specified and directed. |
| 23 | S&F in replacement ceiling rose surface type, 65 mm x 50 mm two to three terminals/ PVC / polycarbonate, isolated body fixed on PVC block complete all as specified and directed. |
| 24 | S&F in replacement sub main wiring two single core PVC insulatedand unsheathed cable with 6 Sqmm multi -strand FRLSH copper conductor drawing in PVC casing caping/ Conduit as per site requirement with 6 Sqmm PVC copper conductor cable as in earth wire system ,including taking out old wiringcomplete all as specified and directed.Note: (i)Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth . (ii)Connections of cables with MCBs or bus bars shall be done throughbrass/copper thimbles of appropriate size . (iii) If Necessary cutting chasing shall be included in this item. |
| 25 | All as per item No. 24 above but 4 Sqmm. |
| 26 | S&F in replacement of existing unserviceable Plug & Socket Box (sheet metal) with PVC Plug,SPN 20 Amps for Acs and complete all as specified and directed. Note :(i) Including cost of masonary work involved and the disturbed surface shall be repaired/match with existing shall be part of job. |
| 27 | S&F in replacement of existing unserviceable Sheet metal enclosure with new DB’s suitable for MCBs of single pole and neutral 4 way double door, IP-54 type with 200 amp rated bus bar complete all as specified and directed. Note: i) Connnections of the MCB\"S shall be done with appropriate size of brass/Cooperthimble. ii) The disturbed surface shall be match with existing shall be part of job. |
| 28 | All as per item No. 27 above but 8 way double door. |
| 29 | All as per item No. 27 above but 12 way double door. |
| 30 | S&F in replacement of existing unserviceableSheet metal enclosure with DB’s suitable for MCBs of triple pole and neutral 4 way, 415 volt, double door as per IS-8623, IP-54 protection universal mounting copper bus bar with 200 amp rated bus bar double door type with one incoming and 12 outgoing and complete all as specified and directed.Note: i) Connnections of the MCB\"S shall be done with appropriate size of brass/Cooperthimble. ii) The disturbed surface shall be match with existing shall be part of job. |
| 31 | All as per item No. 30 above but 8 way double door. |
| 32 | S&F in replacement of 240V, 10 KA \"B\" curve miniature circuit breaker (MCB SP) of Single Pole and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and complete all as specified and directed. |
| 33 | S&F in replacement upto 32 Amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB SPN) in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 34 | S & F in replacement of existing MCCB TPN, 63 Amps, 415 volts, 25 KA complete fixing in DBs including proper thimbles connections all as specified and directed. |
| 35 | All as per item No. 34 above but 100 Amps. |
| 36 | S&F in replacement of 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable flat or circular stranded conductor size of 10 Sqmm, 2 Core complete all as specified and directed. |
| 37 | All as per item No. 36 above but 16 Sqmm 2 Core. |
| 38 | S&F in replacement LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 39 | All as per item No. 38 above but Warm White 20 W. |
| 40 | S&F in replacement LED light fitting with high out put diffuser 2 feet long, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed |
| 41 | Supply and fix in replacement of Recess mounted LED Warm White luminaire of 9 W LED 3000 K round shape and separate replaceable electronic driver, suitable for grid celling/POP Ceiling Cutout size dia 138 mm including fitment of LED Light in false ceiling/POP ceiling by cutout making, fit in existing cutout and making good the existing ceiling incl cost of lamp & driver complete all as specified and directed. |
| 42 | All as per item No. 41 above but 12 Watt. |
| 43 | Supply and fix in replacement of recess mounted LED luminaire 28 Watt Warm Whitecomplete with all accessories incl cost of lamp & detachable driver suitable for false ceiling, dimensions, (600x600x70) mm complete all as specified and directed. |
| 44 | S&F in replacement Mirror light with Linear & compact 5/7W mirror light with decorative grey end caps,polycarbonate body and ribbed opal diffuser of capacity 9 watt complete all as specified and directed. |
| 45 | S&F in replacement lamp holder, PVC/ polycarbonate type suitable for upto 20 watt bulb for batten fitting complete all as specified and directed. |
| 46 | S&F in replacement ofLED Lamp 9 Watt complete all as specified and directed. |
| 47 | S&F in replacement ofLED Lamp 12 Watt complete all as specified and directed. |
| 48 | S&F in replacement ofLED Lamp 15 Watt complete all as specified and directed. |
| 49 | S&F in replacement of Call bell ding dong AC 230 volt single pole complete all as specified and directed. |
| 50 | S&F LED Bulk head fitting 10 W with Engineering plastic housing &clear prismatic diffuser, heat sink itegrated including md LED 10W complete all as specified and directed. |
| 51 | S & F new generation energy saving and environmental friendly long life LED building security light 1x25 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07,with all accessories including suitable bracket with 32mm bore light grade GI pipe bemd to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twincore from ceiling rose to light fittings complete all as specified and directed. |
| 52 | M&L for replacement of existing unserviceable earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frme 40*40*6mm. and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipeincluding excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I or complete all as specified and directed |
| 53 | S&F in replacement of PVC Conduit of size 15 mm incl all connected accessories (bends, clamps, PVC union & screws etc) for existing wiring complete all as specified and directed |
| 54 | All as per item No. 53 but size 20 mm complete all as specified and directed. |
| 55 | S&F in replacement of flexible conduit of size 15/20 mm incl all connected accessories for existing wiring complete all as specified and directed |
| 56 | Supply, laying, Jointing connecting LTUG cable XLPEinsulated,PVC bedded galvanised steel strip or wirearmoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 sqmm 4 core laid in trenches/ on poles / walls / in ducts / passing through pipes and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed. |
| 57 | All as per serial item No. 56 above but for 16 Sqmm 2 Core. |
| 58 | All as per serial item No. 56 above but for 10 Sqmm 2 Core. |
| 59 | Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out in any type of soil complete all as apecified and directed. |
| 60 | M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified and directed |
| 61 | Returning filling in including, spreading,levelling,watering and well ramming in layers not exc 25cm thick each complete all as specified and directed. |
| 62 | Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. |
| 63 | Supply and laying GI tube 40 mm light grade as in cable protection pipe including all fittings & taking down / taking out from trench complete all as specified and directed. |
| 64 | M&Lfor laying of well burnt Brick 23 cm x11.5 cm x7.5 cm for cable protection complete all as specified and directed |
| 65 | Supply & Fix LED bollard light 10 Watt, warm white, single phase, 220 Volts made of ceramic body material, base plate type mounted on PCC Square duly screwed complete all as specified and directed.Note :- Cost of PCC work 1:3:6 (20 mm) in square shape (.303x.303x.303 mtr ) for mounting of Lights incl with Item cost. |
| 66 | S&F in replacement of 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable flat or circular stranded conductor size of 6 Sqmm, 2 Core complete all as specified and directed |
| 67 | S&F 1.50 sqmm copper conductor cable (multistrand) FRLSH single core PVC insulated cable complete all as specified and directed. |
| 68 | SCHEDULE Á\" SECTION-I: (REPAIR TO GEYSERS WORKS)Note:-Attending of day to day complaints of geysers by draning out the water and taking down carefully from wall after unscrewing nut/bolts geyser 50/35/25 Ltr capacity and opening the same for taking out internal tank, syphon assembley etcincluding replacement of defectiveunserviceable parts, reassembling and refixing after repair complete all as specified and directed. Note: i) Spares shall me measured and paid sepratley under respective items of Sch. ii) Penal charges of Rs 250 per day per complaint shall be imposed on contractor for not attending the complaint within 24 hrs. |
| 69 | Supply only heating unit(element)240 volt AC ISI marked of 1500 watts Circular/triangular shape rating as required at site including rubber washers complete all as specified and directed. |
| 70 | Supply only heating unit(element)240 volt AC ISI marked of 1500 watts special type suitable for Bajaj / CG Geyser ( as per sample ) shape rating as required at site including rubber washers complete, all as specified and as directed. |
| 71 | Supply and replace thermostat switch suitable for 25/35/50 ltr geyser AC 230 volt adjustable range from 0-90 degree Celsius, complete all as specified and directed. |
| 72 | Supply and replace special type thermostat switch suitable for 25/35/50 ltr geyser AC 230 volt adjustable range from 0-90 degree Celsius for Bajat/CG Gerysers ( as per sample ) , complete all as specified and directed. |
| 73 | Supply and replacement internal steel tank of geyser 25 ltr capacity complete with syphon-assembly, 1.5 kw element , rubber gasket , thermostat switch , complete all as specified and directed .Note: The tank shall be tested at site and shall be able to with standthe requisitepressure. Necessary testing equipment shall be arranged by the contractor . |
| 74 | Supply and replacement internal steel tank of geyser 50 ltr capacity complete with syphon-assembly, 2.0 kw element , rubber gasket , thermostat switch , complete all as specified and directed.Note: The tank shall be tested at site and shall be able to with stand requisite pressure . Necessary testing equipment shall be arranged by the contractor . |
| 75 | Supply and replacement of syphon assembly made out of brass of 50 ltr capacity including necessary studs, screws and rubber gasket/washers complete all as specified and directed. |
| 76 | All as per Srl item No. 75 above but for 25 ltr capacity, complete all as specified and directed. |
| 77 | Supply and replacement outer body suitable for 50 ltr geyser made out of MS sheet factory made complete with fixing bracket matching with existing, complete all as specified and directed. |
| 78 | Supply and replacement outer body suitable for 25ltr geyser made out of MS sheet factory made complete with fixing bracket matching with existingcomplete, all as specified and directed. |
| 79 | Supply and replace glass woolof 25ltrs capacity geyser, complete all as specified and directed. |
| 80 | All as per Srl item 79 here in beforebut in 50 ltrs capacity geyser, complete all as specified and directed. |
| 81 | Supply and replace indicator lamp round/square type suitable for geyser 25/50 ltr all as per sample AC 230 Volt, complete all as specified and directed. |
| 82 | Supply and replace PVC connection 15mm dia 60 cm long complete with brass flair nuts at both ends. ( ISI marked and suitable for hot water supply upto 100 degree celcius), complete all as specified anddirected. |
| 83 | Supply and replace PVC connection 15mm dia 90 cm Longcomplete with brass flair nuts at both ends. ( ISI marked and suitable for hot water supply upto 100 degree celcius), complete all as specified anddirected. |
| 84 | Supply and fixing anchor bolt 12mmX100mm long complete all as specified and directed (Note:- Anchor bolt shall be grouted with hammer drill only) |
| 85 | Supply and fixing in replacement of defective mild steel base plate cup any type with screws of suitable size as per requirementcomplete, all as specified anddirected. |
| 86 | Supply and fixing in replacement of 15mm stop valve CP fancy type,cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe unions and suitable, complete all as specified and directed. |
| 87 | Supply and fixing in replacement of 1100 Volt grade cable flexible 3 Core PVC insulated PVC sheathed withstranded copper conductor of size 2.5 sqmm, complete all as specified and directed. |
| 88 | Supply and fixing in replacement of CP connection brass with flair nuts all as per sample, complete all as specified and directed. |
| 89 | Cleaning / scrapping of old paint/dust and painting of geysers of 25/35/50 litres capacityat site/ storeswith two coat of super enameled painting by spray, complete all as specified and directed. |
| 90 | Supply and fixing in replacement single pole and neutralenclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, complete all as specified and directed. |
| 91 | Supply and fixing in replacement of mild steel galvanised iron water tubing 15mm bore with screwed & socket joints, medium grade, in short lenghts, with and including all fittings such as sockets, bends, elbow, unions, tees, diminishing pieces etc, fixed to wall or ceiling or in floor complete all as specified and directed. |
| 92 | Supply and fixing plug top 15 Amp three pin for geysers, complete all as specified and directed. |
| 93 | S&F in repair Bib taps, cast copper alloy with crutch orbutterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed of size 15mm dia, complete all as specified and directed. |
| 94 | M&L in repair for point wiring with2.50 sqmm in copper conductor cable ( multistrand) FRLS single core PVC insulated cable in and including PVC conduit( ISI Marked) with all accessories ie PVC gutties etc terminated insunken/pressed metal flush box and white modular cover plate with frame for mounting of switches /sockets/ fan regulators etc and continuous earth wire 1.5 Sqmm copper stranded conductor ascontinuous earthwire connected to common earth dolly complete all as specified and directed.Note : i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB\"s in DB\"s without any extra cost.ii) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth. |
| 95 | SECTION-II: REPAIR TO SOLAR WATER HEATING SYSTEMAttending of day to day Solar Water Heating System complaints taking down, opening up, reassembling, refixing and testing of Solar Water Heating System including replacement of unserviceable parts wherever required at the discretion of the Engr-in- Charge shall be carried out by the contractor for efficient functioning of Solar Water heating System. The cost of material will be measured and paid seperately for replalacement of parts complete all as specified and directed.Note: (i) Schedule of repair to Solar Water heating System is catered for attending day to day complaints of different items within the prescribed time schedule as decided by the EIC on complaint slip, failure to attend the complaint within the prescribed time shall attract a penalty of Rs 250 per day per complaint.Note: All repair to Solar water heating system shall be carried out from an authorized person of the manufacturer of the system and proof there of shall be produced to the GE before undertaking repairs. Contractor is advised to visit the site to ascertain the model and manufacturer of system before quoting his rates. |
| 96 | Supply and replacement solar flat plate collectorhaving collection area not less than 2.0 sqm made out of aluminium frame and toughened glass suitable for solar panel system complete all as specified and directed. |
| 97 | Supply & fix in repairs Heating element, 3 KW, ISI marked, copper sheathed, nickel plated suitable for any type, make, size of solar water geysers, complete all as specified and directed. |
| 98 | Repairs and replacement to existing MS framed supports to SS water tank of solar heating system of capacity 200/300/500 LPD by welding , provinding necessary MS pieces to strenghthing the frame, complete all as specified and directed. |
| 99 | De scaling of solar water heater complete of 300 LPD capacity with 02 Nos solar panel using suitable chemical including unsv nut bolts washer etc complete all as specified and directed. |
| 100 | De scaling of solar water heater complete of 500 LPD capacity with 02 Nos solar panel using suitable chemical including unsv nut bolts washer etc complete all as specified and directed. |
| 101 | M&L for preparing new surface of steel of any description and applying two coats of synthetic enamel paint over a coat of red oxide complete all as directed and specified. |