| Sl. No. | Item Description |
| 1 | Maintenance / servicing / repairing/ cleaning / works/ for AC plant package type 10 x 3= 30 TR package plant,condenser Air cooled type-06 Nos, Compressor 5.5 TR -06 Nos, Thermometer / pressure gauge/ complete duct / AHU packagecomplete system, Connection tubes, PCB & sensor system, humidifier system (heating)/ hot water generatorand the following works/maintenancecarried out this scope work & and replacement of unsvparts paid separately mentioned &complete Natatop stn all as specified and directed Engr-in-Charge .(Note :1 :- Item Srl no: 1, (a) Above all attending to complaint/break down calls when called upon.Repair/replacement of microprocessor control if installed.Reporting the healthiness of the plant and suggesting improvements if any)(b Leakage shall be tested with Nitrogen(c) This scheme does not cover damage to equipment / ancillaries or failure due to environmental conditions and due to contaminated / hard water, there itmes measured and paid separatly under respetive schedule.(d) Each plant will be tested in the presence ofEngineer-in- Charge. (e) The test results shall be recorded and shall be preserved duly signed by the contractor, Engineer-in- Charge. (f)Descaling of cooling coil of conder by usining acidcent and brush etc.(g)The material procured and brought at site by the contractor shall be got approved from Engr-in- Charge /GE before incorporation in the work.(i)Clean water strainers. (ii)Check the earth connection and fuses.(iii)Clean the condenser and otherequipments. (iv)Check for leakage of gas (exterior).(v)Clean the controls.(vi)Clean all the air filters.(vii)Check compressor oil for discoloration or contamination. (viii)Check starting and running current and voltage while running.(ix)Check the insulation resistance valve. (x)Defrost cooling coil, close suction line slowly and note the efficiency.(xi) Check leak in the seal of shaft.(xii)Check leak LP and HP cut-outs i.e. (xiii) Check expansion valves. (xiv)Check for entire system with the help of water & soap.(xv) Clean the drip tray with water.(xvi)Check the condition of blower fans, shafts and its direction of rotation.(xvii)Check the ducting condition.(xviii) Check the working of the plants and limits of vibration and noise (xix) Carry out the capacity test. (xx) Check suction and delivery of the compressor and its efficiency.(xxi)Clean the condenser with compressed air, brush and water .(xxii)Dismantle the weather make chamber by removing duct connections and opening the return air box, clean the evaporator coil, drip tray, ducting and repair the return air box (if required) , paint the system and re-install the same.(xxiii) Overhaul the blower motor including cleaning of runners.(xxiv) Check the service valves for wear.(xxv)Overhaul the compressor motor and starter xxviClean the contacts of LP/HP switches.(xxvi) Check and adjust the alignment of belts and their tension.(xxvii)Check the wiring and all the connections including meggering.(xxviii)Complete test for leaks.(xxix) Check thermostatic switch and clean the contacts(xxx) water cooled system/water line deacling & paintng incl cooling tower (xxxi) all pump any size overhuling and repairing /replacement of unserviceable gland / shaft/ bearing/ gland cupling complete(xxxii) Cooling tower cleaning with Scrapper . |
| 2 | M&L for Descaling of Water cooled Condencer of Package unit with cleaning of cooling coil, Air filters and cleaning of Cooling Tower of 10 TR |
| 3 | M&L for R-22/407 & 410Gas Charging for Ductable & Packaged type AC plant include welding work complete all as specified and as directed. |
| 4 | M&L forN2 Flushing, leakage testing & Vaccummissing for AC plant complete all as specified and as directed. |
| 5 | M&L forMotorizedFP Dampers for Duct at distribution ends AC complete all as specified and as directed. |
| 6 | M&L forMotorized FPDampers for ducts atPackaged AC complete all as specified and as directed. |
| 7 | S&F in repair Compressor of capacity 5.5 toncomplete all as specified and as directed by Engr-in-Charge. Make: Voltas or its equivalent |
| 8 | S&F in repair PCB circuit forpackage type AC complete all as specified and as directed by Engr-in- charge. |
| 9 | S&F in repair 3HP ,415 Volt,50HZ Blower motorfor packagetype AC complete all as specified and as directed by Engr-in- charge. |
| 10 | S&F in repair Single Phase preventer complete all as specified and as directed by Engr-in- charge. |
| 11 | S&F in repair AL powder coated Grill complete all as specified and as directed by Engr-in- charge. |
| 12 | S&F in repair AL powder coated Diffusers complete all as specified and as directed by Engr-in- charge. |
| 13 | S&F in repair HP Switch Packaged type AC complete all as specified and as directed by Engr-in- charge. |
| 14 | S&F in repair LP Switch Packaged type AC complete all as specified and as directed by Engr-in- charge. |
| 15 | S&F in repair Sensor for Packegedtype AC complete all as specified and as directed by Engr-in- charge. |
| 16 | S&F in repair Expension valve 5.5 TR complete all as specified and as directed by Engr-in- charge. |
| 17 | S&F in repair Insulation Nitrile Rubber 13mm complete all as specified and as directed by Engr-in- charge. |
| 18 | S&F in repair Canvass Connection fire proof complete all as specified and as directed by Engr-in- charge. |
| 19 | S&F in repair Copper piping, Insulation, supporters, Nut bolts, painting of pipe ( If requierd ) Angle bracket etccomplete all as specified and as directed by Engr-in- charge. |
| 20 | S&F in repair MCCB 4 Pole,250A, Breaking capacity 36 KA, 415 V, 50 Hzwith OL, SC, protection, -01 Nos complete all asspecified and as per existing size directed by Engr-in- charge. |
| 21 | S&F in repair MCCB 4 Pole, 100 A, Breaking capacity 36 KA, 415 V, 50 Hzwith OL, SC, protection, -01 Nos complete all as specified and as per existing sizedirected by Engr-in- charge. |
| 22 | S&F in repair MCCB 4 Pole,160A, Breaking capacity 36 KA, 415 V, 50 Hzwith OL, SC, protection, -01 Nos complete all as specified and as per existing suitablesize directed by Engr-in- charge. |
| 23 | S&F in repair Power contactor 32 Amps 3 pole as per sample complete all as specified and as directed by Engr-in- charge. |
| 24 | S&F in repair Power contactor 100Amps 3 pole as per sample complete all as specified and as directed by Engr-in- charge. |
| 25 | S&F in repair Air pressure meter /guageas perexisting model complete all as specified and as directed by Engr-in- charge. |
| 26 | S&F in repair Temperaturemeter /guageas perexisting model complete all as specified and as directed by Engr-in- charge. |
| 27 | S&F in repair strip heater 3 KWcomplete all as specified and as directed by Engr-in- charge. |
| 28 | Disconnectingthe motor with centrifugal pump set and Repair/Rewinding of motor ofcapacity 3/5 HP three phase 415 Volts ,50 HZ byrewinding the motor with super enamelled copper conductor of standard size including varnish, insulation paper and tape . Assembly of motor with pump set with necessary studs, bolts, washers and bearing etc complete all as specified and directed. |
| 29 | Disconnectingthe motor with centrifugal pump set and Repair/Rewinding of motor ofcapacity 7.5/10 HP three phase 415 Volts ,50 HZ byrewinding the motor with super enamelled copper conductor of standard size including varnish, insulation paper and tape . Assembly of motor with pump set with necessary studs, bolts, washers and bearing etc complete all as specified and directed. |
| 30 | Disconnecting of startor and Replacement of unserviceable/ burned spare parts robust 4 pole contactor type TC1-DX/ over load relay type LR3DM/ auto start switch with Auto/manual start DIP switch, voltmete with 3P selector switch & TP MCB for Short circuit protection, suitable for relay range 12 to 25 Amps etccomplete all as specified and directed. |
| 31 | S&F in repair cast iron Butterfly Valve 100mm bore , SS dise type with handlever operated,lining test pressure PN 1.6ISI marked including welding workwith all fittings such as nuts , bolts, washers and rubber gasketetc complete in all respect all as specified. |
| 32 | S&F in repair cast iron Butterfly Valve 80mm bore , SS dise type with handlever operated,lining test pressure PN 1.6ISI marked including welding workall fittings such as nuts , bolts, washers and rubber gasketetc complete in all respect all as specified. |
| 33 | Maintenance ,Repair and servicing, includingoftesting ofvertically mounted Thermic Fluid Heater (TFH) capable of delivering a heat output 100000 K Cal/Hr, one working and one stand by )total 04 Unit using HSD oil complete in all respect, including following item of work:-(a) Heater unit : heat exchanger, consisting of closely wound, helical, concentric coils, arranged to give adequate no of passes on flue gas side & made out of ERW tubes, confirming to IS 3059 Pt-I, suitable for high temperature all as per manufacturer design and of required head and capacity.(b) Pressure jet burner : suitable for light oil firing with stepless modulation mechanism all as per manufacturer design and of required head and capacity.(c) Combustion air fan with drive motor assembly all as per manufacturer design and of required head and capacity.(d) Control Panel : Dust protected pre-wired unit mounted air cooled control panel housing a burner management system , switchgear consisting of contractors, overload relays, fuses and MCB etc.all as per manufacturer design and of required capacity.(e) Circulating Pumps : Centrifugal Thermic fluid circulating pumps suitable for high temp operation, coupled with electric motor drive, mounted on common base frame all as per manufacturer design and of required head and capacity.(f) DE Tank : Derator cum expansion tank consisting of expansion, derator and buffer vessels , guage glass assembly and level switches. Nozal for inlet and outlet on derator for drain on buffer vessel and for overflow, air vent and topup on expansion vessel all as per manufacturer design and of required head and capacity. |
| 34 | Supply only in replacement of spareparts33.01 to 33.12 complete all as specified and directed Engr-in- charge. |
| 35 | Temp controller-TC513 |
| 36 | Sequence controller-LOA 24 171b27 |
| 37 | Photocell-Qrb-1A |
| 38 | Fuel pump-D57a |
| 39 | igniation transformer |
| 40 | spark plug |
| 41 | Burner inlet out let pipe |
| 42 | Burner relay |
| 43 | solonied valve |
| 44 | Contactor 10/16 Amps |
| 45 | temp control |
| 46 | Blower Moter for boiler 1/8 HP |
| 47 | S&F in repair singlephase permanently lubricated 1/2 HP-62 watt for indoor unit of central Air heating plant complete all as specifiedand as directed.Make : GE motor India PVT Ltd- Model NO 5KCP 29DG686 or its equivalent. |
| 48 | S&Fin repair of solenoid valve suitable for indoor unit of central heating plant complete all as specifiedand as directed. |
| 49 | S&F in repair SPE echo frame -ignition transformer - COFIE 820-T-120complete all as specifiedand as directed. |
| 50 | Repair and sevicing of suspended / wall mounted type fan coil units constructed out of 20 SWG GI casing powder coated, with two no air blowers motor driven, 3rd heating coil, 12 mm thick pre filter with drain pan insulated with 12 mm thick closed cell nitric insulation of 1.0 Ton capacity including inlet/outlet valves, air guage valve, thermostatic control with all connected accessories and fitting required, suitable match with model of thermex plants incl internal wiring with PVC insulated flexible copper conductor cable of appropriate sizeincluding taking down all as specified and directedat site by Engr-in-Charge. |
| 51 | Repair and servicing of suspended / wall mounted type fan coil units constructed out of 20 SWG GI casing powder coated, with two no air blowers motor driven, 3rd heating coil, 12 mm thick pre filter with drain pan insulated with 12 mm thick closed cell nitric insulation of 1.5 Ton capacity including inlet/outlet valves, air guage valve, thermostatic control with all connected accessories and fitting required, suitable match with model of thermex plants incl internal wiring with PVC insulated flexible copper conductor cable of appropriate sizeincluding taking down all as specified and directedat site by Engr-in-Charge. |
| 52 | Servicing of hot water boiler, disconcting electric drain out water opening of burner chamber boilerasembly, al accessories and mountingtaking out helical coil of make-alfa therm hot generator 100000K Cal / Hrs, cleaing of combustion chamber reparing/ replacement of any unsv part as specified in eachitcomplete all as specifeid and directed , ms mentioned. Note:-The job shall be carried out during entire period of contract. Repair of hot wate boiler of cqapacity 100000K cal/Hr including repair / replacement of following parts from item No. (39.01) to (39.22) to make it functional as specified and directed by Engr-in-Charge. |
| 53 | Supply only in replacementhelical coil asembly complete all as specified and as directed by Engr-in- charge. |
| 54 | Supply only in replacementinput ignition transformer220 volts ofoutput 11KV to 14 KV complete all as specified and as directed by Engr-in-charge |
| 55 | Supply only in replacementgasket suitable for hot water boiler complete all as specified and as directed by Engr-in- charge. |
| 56 | Supply only in replacementsequence controller for hot water boiler complete all as specified and as directed by Engr-in- charge. |
| 57 | Supply only in replacement refactory plate as per sample complete all as specified and as directed by Engr-in- charge. |
| 58 | Supply only in replacementof differential pressure Gauge- 0 to 10 Kg/ Cm square suitable for hot water boiler complete all as specified and as directed by Engr-in- charge. |
| 59 | Supply only in replacement ofphoto cell for hot water boiler complete all as specified and as directed by Engr-in- charge. |
| 60 | Supply only in replacementmotorised barrel pump of capacity 1 HP , 2850 RPM, Single phase with rubber hose pipe 15 RM complete with all accessories complete all as specified and directed by Engr-in-Charge . Make: Bharat, Kirloskar |
| 61 | Supply only in replacementgate valve of capacity 50mm dia suitable for hot/ cold water complete all as specified and as directed by Engr-in- charge. Make: Leader/ surya parkash. |
| 62 | Supply only in replacementgate valve of capacity 40mm dia suitable for hot/ cold water complete all as specified and as directed by Engr-in- charge. Make: Leader/ surya parkash ISI marked. |
| 63 | Supply only in replacement solenoid valve for hot water boiler complete all as specified and as directed by Engr-in- charge |
| 64 | Supply only in replacementof fuel TPL pipe to buring assembly for hot water boler complete all as specified and as directed by Engr-in- charge |
| 65 | Supply only in replacementof fuel filter assembly 1/2 Ltr capacity with filter complete all as specified and as directed by Engr-in- charge |
| 66 | Supply only in replacementburner of boiler for 1 L K cal make ecoflame or equivelant or as per sample complete all as specified and as directed by Engr-in- charge |
| 67 | S&F in repair starting panel of boiler for 1 LK cal make as per sample Rapid cool complete all as specified and as directed by Engr-in- charge |
| 68 | S&F in repairelectronic buzzer for hot water boiler of 1 L Kcal complete all as specified and as directed by Engr-in- charge |
| 69 | Replacement of Gun-metal, globeor gate valves, 40mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked),complete all as specified & directed by Engr-in-Charge. |
| 70 | Replacement of Gun-metal, globeor gate valves, 50mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked),complete all as specified & directed by Engr-in-Charge. |
| 71 | S&F in repairMNX 9 contacter type for hot waterboiler of 1 L kcal complete all as specified and as directed by Engr-in- charge |
| 72 | Supply only in replacementBimetallic relay of 3 to 5 Amp for hot water boiler of 1 L kcal complete all as specified and as directed by Engr-in- charge |
| 73 | Supply only in replacementsingle phase preventer for hotwater boiler of 1 L kcal complete all as specified and as directed by Engr-in- charge |
| 74 | Supply only in replacement control module for hot water boiler of 1 L Kcal complete all as specified and as directed by Engr-in- charge |
| 75 | S&F in testing and commissioning of centrifugal pump set of capacity 3 HP, 3 phase , 415 Volt, 50 HZ & discharge, Head22 to 33 m, size 50x40mm, dischare 4.5 to 2.5 l/s asspecified and directed by Engr-in-Chage. |
| 76 | Taking down old unsv cable and supply and laying of PVC insulated sheathed6 sqmm, 3 core flate multi strand copper conductor cable completeall as specified and directed by Engr-in-Chage. |
| 77 | S&F in repairs of nozzel for WHB as specified and directed by Engr-in-Chage |
| 78 | S&Fin repairs reducer nipplefor WHB as specified and directed by Engr-in-Cahge. |
| 79 | S&Fteflon tape for WHB as specified and directed by Engr-in-Chage. |
| 80 | M&L pump motor of capcity 5 HP with super enamled copper and wire of same gauge etcusing best quality of insulationmateruals turning polishing of motor shaft by machining, of bearing -02 Nos including all necessary partsmake the equipment functional, asper existing model complete all as specified and as directed by Engr-in-Chage. |
| 81 | M&L for Repair of pumpup to 5 HP with replacement of different unsv parts including all necessary repair work to make the equipment fully functional, as directed by Engr-in-Chage.Note:- Spare parts to be replaced for this item will be measured and paid separately. |
| 82 | Supply only in replacement of following item as required for overhauling/ repairing the centrifugalpump set under srl item No. 47.01 to 47.06. |
| 83 | Impeller |
| 84 | Pump shaft |
| 85 | Thrust Bearing |
| 86 | Water seal |
| 87 | NRV |
| 88 | Bushing |
| 89 | M&L for & cleaning of water tank of capacity 10,000 ltr PVC insulated sintex tank using cleaning solution and de-silting as specifed and directed by Engr-in-chage. |
| 90 | S&F in repair star delta starter suitable for 5 HP submersible pump as specifed and directed by Engr-in-chage. |
| 91 | S&F in repair star delta starter suitable for 10 HP submersible pump as specifed and directed by Engr-in-chage. |
| 92 | S&F in repair star delta starter suitable for 3 HP submersible pump as specifed and directed by Engr-in-chage. |
| 93 | M&L in repair K-flex for following MS/ GI pipe 19 thick K-flex insulation including jointing and fixing material such as tape insulation self adhesive with aluminium cladding size of aluminium cladding is not less than 0.1mm |
| 94 | 80 mm dia |
| 95 | 50 mm dia maek: K-flex/ superion |
| 96 | M&L in repair K-flex for following MS/ GI pipe 19 thick K-flex insulation including jointing and fixing material such as tape insulation self adhesive with aluminium cladding size of aluminium cladding is not less than 0.1mm |
| 97 | 40 mm & 25 dia |
| 98 | 20 mm & 15 mm dia |
| 99 | S&F steel water tube medium grade galvanised with all fittings including short lengths, laid in trenchs/ floors / wall with all fittings (such as bends, elbows, Tee, short, pieces,connectors, back nuts, diminishingpieces, caps andplugs, nuions etc.) following size as specified. |
| 100 | 50 mm dia |
| 101 | 40 mm dia |
| 102 | 25 mm dia |
| 103 | 20 mm dia |
| 104 | 15 mm dia |
| 105 | Supply and fixing of Gun metal globe PVC / gate valve from the pipe line and supply and fixing of gun metal globe gate valve (ISI) marked with iron wheel head, screwed both ends for iron pipe all as specified and as directed for the following sizes:- ( Make:Leader / BIR / Zoloto / TATA / KSB / Kartar / Kirloskar) |
| 106 | 80mm dia |
| 107 | 50mm dia |
| 108 | 40mm dia |
| 109 | 20mm dia |
| 110 | 15mm dia |
| 111 | S&F Bends up to 100 bore (any type.radius and angletappers any type,(Straight) ,bend,increasing,decreasing.or double socket etc Tee pieces single branch.\"Y\" junction ,double branch ,cross (all socket or socket and spigot ) colars ,caps and plugs. |
| 112 | Excavation in trenches in any type of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth, for foundation, laying of pipes and getting out, complete all as specified and directed by Engineer-in-Charge |
| 113 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each in any type of soil , complete all as specified and directed by Engineer-in-Charge |
| 114 | Removing excavated spoil (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and directed by Engineer-in-Charge |
| 115 | Taking down of existing MS sheet hot water storage 1500 Ltrs tubulartank from the mounting and checking it forany leakages , damges etc and making on site arrangement for repair of tank by welding with suitable size MS plate making it completely leak proof and refixing the same after wraping with insulation at the existing height and dullyfixing with fastner, nust and boltsetc complete all as specified and directed by Engr-in-chage. |
| 116 | Supplyand laying of PVC insulatedsheathed multi starndedcopper conductor cable 10 sqmm , 4 core mutistandardcopper conductor cable complete all as specifiedand directed by Engr-in-charge. |
| 117 | S&F in repairsof GI socket 20/25 MM complete as per existing size all as specifeid and as directd |
| 118 | S&F in repair of GI socke40/50 MM complete as per existing size all as specifeid and as directd |
| 119 | S&F in repairs of MCB single pole 240 volts 6 to 32 amps C\" Curve, with rupturing capacity 10 KA, all as specified. |
| 120 | S&F in repairs ofMCB SPN240 Volts 40 Amps with rupturing capacity 10KA complete all as specified and as directed. |
| 121 | S&F in repairs of MCB Tripplepole 240 Volts 40Amps with rupturing capacity 36KA complete all as specified and as dierected . |
| 122 | S&F in repairs ofMCB Tripplepole 240 Volts 63Amps with rupturing capacity 36KA complete all as specified and as directed . |
| 123 | M&L for lagging / insulation of pipe in repair of GI pipe including plumbing etc if required with 25mm thick bounded mineral wool pre sections \"SNAP ON\" pipe sections of denicity 144 Kg/cum conforming to IS-9842 for 50mm dia GI pipe including chicken mesh wire netting 25 mm gauge, 20mm mesh added and with alluminium foil of .01 mm 15/20mm GI pipe suitablecomplete all as specified and directed. |
| 124 | S&F in repair of Stop valves,cast copper alloy screwed down high pressure with crutch or butterfly handel screwed both ends for iron pipe or for brass ferrule and fixed for 25 mm bore pipe,complete all as specified and directed at site. |
| 125 | S&F in repair of Stop valves,cast copper alloy screwed down high pressure with crutch or butterfly handel screwed both ends for iron pipe or for brass ferrule and fixed for 20 mm bore pipe,complete all as specified and directed at site. |
| 126 | S&F in repairof Off Load Change over switch 200 Amps with enclosure Rated Voltage 415 AC 50HZ Type 4 Pole complete all as specifed and as directed |
| 127 | S&F in repair Off Load Change over switch 400 Amps with enclosure Rated Voltage 415 AC 50HZ Type 4 Pole complete all as specifed and as directed |
| 128 | S&F in repairOff Load Change over switch 100 Amps with enclosure Rated Voltage 415 AC 50HZ Type 4 Pole complete all as specifed and as directed |
| 129 | Dismentalling ofsquirrel cage induction ofmotor capacity 3 HP ,440 volts 1500 RPM andrewindingwith supper enamelledcopper conductorwire as perexisting gauge and Nos of turnsincluding insulation material and taking out from its orginal position and transportation from site to workshop completeall as directed. |
| 130 | S&F in repair up to 3 HP motorcomplete rewinding and replacing condensior ,fancompleteas per existing Model all as specified and directed by Engr-in- charge. |
| 131 | S&F in repair 5 HP motor with long shaft ,3 phase, 415 volt, 50 Hz complete as per existing Model complete all as specified and directed by Engr-in- charge. |
| 132 | M&L in repair ofwiring for circuit 2 core 2.5 sqmm copper conductor flexiblecablePVCinsulated PVC sheatedas per is 694 up to date all includingone earth wire drawing through PVC surfaceconduit makingconnection with LED Building security Light/ towerlight /fitting etc complete all as specified and as directed by enginer in charge . |
| 133 | M&L in repair of wiring for circuit 3 core4.0 sqmm copper conductorflexiblecable PVCinsulated PVC sheatedas per is 694 up to date all including drawing through PVC surfaceconduit makingconnection with LED Building security Light/ towerlight /fitting etc complete all as specified and as directed by enginer in charge . |
| 134 | M&L in repair of wiring for circuit 3 core 6.0 sqmm copper conductor flexible cablePVCinsulated PVC sheatedas per is 694 up to date all including drawing through PVC Conduit makingconnection with LED Building security Light/ towerlight /fitting etc complete all as specified and as directed by enginer in charge . |
| 135 | Supply and fix in repair of Integral LED aviation light luminaire in yellow die-cast aluminium alloy housing with red coloured polycarbonate dome ofincluding necessary electric connection 2.5 sqmm 3 core pvc insulated PVC copper cable as per manufacture\"s requirement and building /tower height up to 30mtr complete all as specified and as directed by Engineer-in-Charge.Cat part No BGAV 302 LED of make Bajaj or equivalent C&S/CG/Philips |
| 136 | Taking down/ dismentling the old / UNSV duct of central AC plant and M&L to assembly/ eroction of GI sheet with C&SS , rectangular / boxed, incls all accessories such as corner, cleat , carriage bolt, gasket and appropriate sealant on longitudinal joints etc complete of size 26 gauge . In Laid Wool installation not less than 30 mmthick over allsurrounding the duct and 15 mm thick cement randering work over / around the complete duct with chicken wire mess of suitable size all is specified and directed. Note: Theinner size ofduct is not less than existing. |
| 137 | Supply and fixed rolled mild steel Joist channel,angle or tee sections fixed independently ,with out connecting plates etcconforming to FE 410-W Quality -Aalonwith welding/ rivetingof specifeid shape and necessary civil /PCC work(ie 30cm below ground level and 40 cm above level )etc.complete all as specified and as directd. |
| 138 | Servisingof OFR 25 watt 13 fin oil filledradiator for Noiselessand checking ofheating adjustable thermostateand three heat setting featuring safety tilt and an autothermal cut off to prevent overheating complete all as specified and as directed. |
| 139 | Supply only in replacement of following item as required forradiator 83.01 to 83.04 |
| 140 | Heating Adjustable thermostate |
| 141 | Three Heat setting featuring safety tilit |
| 142 | Auto thermal cut off Switch to prevent overheating |
| 143 | On off switch |
| 144 | Repair of Corded ElectricRod of1500 wattto 2400 wattcopper heat pillar portable type room heater 230 volts AC with twin hallogen rods complete all as specified and directed. |
| 145 | Supply and fixing of heater /blowerheating rodhalogen type warm white startrack 24 & 23 cm pin type corded electricany size any cap or as per existing size complete all as specifeed and as directed |
| 146 | M&Lof motor of capcity 1.5 HP with super enamled copper and wire of same gauge etcusing best quality of insulationmateruals turning polishing of motorincluding all necessaryrepair work to make the equipment functional, as directed by Engr-in-Chage. |
| 147 | M&L Earthing complete as per electrical plate No 5 of MES SSR Part I with galvanised steel plate earth electrode 60 cm x 60 cm x 6.0 mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to and including galvanised iron or steel earth strip 25 x 4 mmby means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing strip protected by galvanised iron or steel pipe 50 mm bore medium grade and connected to continuous earth wire on pole/ test point.Watering pipe shall be 20mm bore GI medium grade. The earthing shall be inclusive ofexcavation and earth work in any type of soil, charcoal, salt, funnel , PCC pit and RCC cover complete all as specified & directed by Engr-in-Charge.Note 1- following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labourfor connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal, dust, common salt and ground enhacement material as required to bring the earthing resistance as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. |
| 148 | Earthing complete with copper earth plate electrode of size 60 cm x 60 cm x 3.15 mm thick as earth electrode burried directly in groundwith top edge of the earth plate not less than 2.5mtr below ground level using copper earth strip 20 x 3 mm dia as earth continuity conductor connected to earth plate by means of copper thimbles, nuts, bolts, washers including brazing etc of earth electrode and earth wire by means of welding, all as directed including providingwatering pipe 20mm dia with wire mesh and funnel at top, earth pit andpit cover made of MS sheet 10 mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil , removing surplus excavated material all as required at site and as specified in EP No 3 of MES SSR Part-I (2009) directed by Engineer-in-charge including testing on completion. Note : (i)(ii) The grid of earthing trhough earth strip to achieved earth resistance less than 01 ohm to 05 ohm shall be deemed into the quoted rate and no extra payment shall be made to contractor. (iii) The test point shall be made after the grid of earthing and algebric sum of of stripwith GI protation pipe shall be measured after 7.5 mtr earth pit.The strip beyond the totalsum shall be paid seperately (c)Earthing will be carried out in presence of users and MESrep with entire satisfaction. (d) The ground enhansing material (GEM) / chemicals shall be added with soil and the GEM/chemicals shall be deemed to be included shall be quoted rates. |
| 149 | M&L of Aluminium strip 25x 3mm with saddless and fixing screws etc for roof conductors and down conductors above ground complete as specified and as directed. |
| 150 | M&L of Copper strip 20x 3mm with saddless and fixing screws etc for roof conductors and down conductors above ground complete as specified and as directed. |