Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 18-09-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 25-09-2024 |
| Sl. No. | Item Description |
| 1 | Disconnecting, dismantling and strip opening of the existing air handling unit of any description and in any position and of capacityup to 10000 CFM for overhauling and servicing with suitable chemical as directed by Engr-in-Charge including taking out existing shaft, blower, drum, pulley and dehumidifier pump etc. of air handling unit, checking thoroughly the serviceability of the parts,dismantling the parts, fixing the serviceable parts in original position, replacement of the defective/non-functional /unserviceable parts /spares, reassembling, commissioning, fixing in position and testing of the air handling unit on full load for its smooth and trouble free operation complete all as specified and directed .Note :-(i)The quoted rates of the contractor includes for fixing the serviceable parts in original position and replacement of unserviceable parts with new parts.The new replaced parts shall bemeasured and paid for separately under appropriate item of Sch `A’ as `supply only.(ii)Remetaling & grinding of the crank shaft, wherever applicable shall be measured and paid for separately under appropriate item of Schedule `A\".(iii) Rates quoted by the contractor shall include the cost of transportation of any part of the AHU unit to and from approved workshop for their repair and alignment. |
| 2 | All as per item No 01 here-in-before but, for air handling unit of above 10000 to20000 CFM capacitycomplete all as specified and directed |
| 3 | All as per item No 01 here-in-before but, for air handling unit of above 20000 to30000 CFM capacitycomplete all as specified and directed |
| 4 | Supply only thefollowing spares / parts suitable for Air handling units repaired under respective Sch ‘A’ item No. 01 to 03 for servicing / overhauling of AHU complete all as specified and directed.(a) Pedestal bearing no NTN 205 J (Japan) or equivalent of make SKF /NBC complete all as specified and directed. |
| 5 | (b) Pedestal bearing no NTN 206 J (Japan) or equivalent of make SKF/NBC complete all as specified and directed |
| 6 | (c)Pedestal bearing no NTN 207 J (Japan) or equivalent of make SKF/NBC complete all as specified and directed |
| 7 | (d)Pedestal bearing no NTN 211 J (Japan) or equivalent of make SKF/NBC complete all as specified and directed. |
| 8 | (e) Mild steel shaft pulley 8” dia, B section, double groove inner bore 32mm with suitable slot for key complete all as specified and directed |
| 9 | (f) Mild steel shaft pulley 8” dia, B section, three groove inner bore 25mm with suitable slot for key complete all as specified and directed. |
| 10 | (g) Mild steel shaft pulley 4” dia, B section, double groove inner bore 25 mm with suitable slot for key complete all as specified and directed. |
| 11 | (h) Cast copper alloy gate valve 20mm nominal bore,screwed down high pressure, with crutch or butter fly handle complete all as specified and directed Make :Sant/Zoloto/Leader/BIR. |
| 12 | (j) Cast copper alloy gate valve 25mm nominal bore,screwed down high pressure, with crutch or butter fly handle complete all as specified and directed Make :Sant/Zoloto/Leader/BIRNote(i) Cost element of removing unserviceable parts, fixing and testing of the new items/ parts is deemed to beincluded in the respective rates quoted by the contractor under respective item of Sch ‘A’ (ii)Contractor shall have no claim on account of variation of quantities of these items/non execution of any of the above items and contractor shall be paid for at as quoted rates only for the parts actually replaced. |
| 13 | S&F‘V’ belts of following cross section,pitch length & sizeincluding disconnection and taking down of ‘V’ belts from motors complete all as specified and directed, Make : Fenner / Hilton.(a) Cross section 17 x 11 mm & pitch length 4030 mm of size B-159 |
| 14 | (b)Cross section 17 x 11 mm & pitch length 2910 mm of size B-113 |
| 15 | (c)Cross section 17 x 11 mm & pitch length 1770 mm of size B-68 |
| 16 | (d)Cross section 17 x 11 mm & pitch length 1800 mm of size B-69 |
| 17 | (e)Cross section 17 x 11 mm & pitch length 2300 mm of size B-89 |
| 18 | (f)Cross section 17 x 11 mm & pitch length 1820 mm of size B-70 |
| 19 | (g)Cross section 17 x 11 mm & pitch length 1010 mm of size B-38 |
| 20 | (h) Cross section 17 x 11 mm & pitch length 2790 mm of size B-108 |
| 21 | (j) Cross section 22 x 14 mm & pitch length 3360 mm of size C-130 |
| 22 | (k) Cross section 22 x 14 mm & pitch length 2720 mm of size C-105 |
| 23 | Supply only MCB SP 6-32 Amps 240 Volts complete all as specified and directed. |
| 24 | Supply only MCB SPN 16-32 Amps 240 Volts complete all as specified and directed. |
| 25 | Supply and fixing in replacement offan set of size suitable for up to 75 TR Air Cooled AC Plant with hub assembly sweep 1200 mm& 4 blades complete all as per sample all as specified and directed. |
| 26 | M&L for Servicing of existing cooling tower FRP type, of any description & in any position complete including dismantling all old connected parts/items line motor PVC filling, MS/GI pipe, sluice valve, stop valve, steel structure frame etc servicing, overhauling, cleaning,painting with one coat of paint (approved colour), painting of complete pipe line of entire plant by scrapping & preparation of old painted MS/GI pipe of plant with colour code as directed by Engr - in - Charge and marking arrow for indicating direction of flow are inclusive under quoted rate and fixing of serviceable parts in position, removing & replacement of defective/unserviceable parts with new parts, reassembling the cooling towers and connected parts/items fixed in original position for connecting to existing system and testing at site on full load to the entire satisfaction of the EIC complete all as specified and directed for the following capacity:-Note (i) The replacement of defective/non functional parts shall be measured and paid separately as `supply only\" under appropriate items of sch `A\" and fixing rate for new items are deemed to include under this item.(a) Cooling tower of plant capacity 10 - 50TR |
| 27 | (b) Cooling tower of plant capacity above 50 and upto 100 TR |
| 28 | (c) Cooling tower of plant Capacity above 100 and upto 200 TR |
| 29 | Supply only PVC filling blocks of size as per sample suitable for cooling towercomplete all as specified and directed. |
| 30 | Supply and fixing in repair ofAluminium fan set of Cooling Tower suitable for 10 to 50TR with hub assembly sweep upto1400 mm& 4 bladescomplete as per existing all as specified and directed. |
| 31 | Supply and fixing in repair ofAluminium fan set of Cooling Tower suitable for 10 to 50TR with hub assembly sweep upto 1600 mm& 4 bladescomplete as per existing all as specified and directed. |
| 32 | Supply and fixing in repair ofAluminium fan set of Cooling Tower suitable for 10 to 50TR with hub assembly sweep upto 1800 mm& 4 bladescomplete as per existing all as specified and directed. |
| 33 | Supply and fixing of bottom waterline CI filter and replacement of strainer jalli including nuts bolts etc complete as per existing all as specified & directed of following size:- (a) 200mm |
| 34 | (b) 100mm |
| 35 | (c)80mm |
| 36 | Supply and fixing repair and replacement of rotary sprinkler with head cagin with frame and PVC header assembly of following capacity of cooling tower complete including PVC pipe of suitable size and length as required complete all as specified and directed of following size :-up to- 50TR |
| 37 | (b)Above 50 and upto 100 TR |
| 38 | (c)Above 100 to200 TR |
| 39 | S&F PVC plate as per existing suitable for insertion of fillers of cooling tower as per sample complete all as specified and directed for the following Cap cooling towers :- |
| 40 | (a)Upto 50 TR |
| 41 | (b)Above 50 and upto 100 TR |
| 42 | (c)Above 100 to200 TR |
| 43 | S&F PVC Nozzles of sizes 2 to 3 inch suitable for fixing in cooling tower complete all as specified and directed. |
| 44 | Supply and fixing PVC float valve of size 25mm and model as per existing complete all as specified and directed. |
| 45 | Supply and fixing Gun metal gate/globe valve of size 25 mm dia with iron wheel head, screwed both ends for iron pipe complete all as specified and directed |
| 46 | Supply and fixing Gun metal gate/globe valve of size 20 mm dia with iron wheel head, screwed both ends for iron pipe complete all as specified and directed |
| 47 | Supply and fixing PVC mesh for complete tower as per existing suitable for following cooling tower of capacity all as specified and directed :-(a)Upto 50 TR |
| 48 | (b)Above 50 and upto 100 TR |
| 49 | (c)Above 100 to200 TR |
| 50 | Supplying, laying, commissioning in replacement including testing M S Pipes of 100 mm bore size, heavy grade with all fittings / welding as required at site, laid in floors or fixed to walls / supports and ceilings for AC plants complete all as specified and directed. |
| 51 | All as per item No 20 here-in-before but of size 80 mm bore |
| 52 | Supply, laying , commissioning including testing in replacement of GI Pipe of Medium Grade of size 25 mm bore complete all as speicified and directed |
| 53 | Supplying, laying , commissioning including testing in replacement of cast iron butter fly valve as per sample of size 200 mm bore complete all as speicified and directed. |
| 54 | All as per item No 23 here-in-before but of size 150 mm bore |
| 55 | All as per item No 23 here-in-before but of size 100 mm bore |
| 56 | All as per item No 23 here-in-before but of size 80 mm bore |
| 57 | All as per item No 23 here-in-before but of size 65 mm bore |
| 58 | Disconnecting, dismantling & taking up/down AC electric motorsof any description and in any position from existing foundation of compressor/blowers/pumps/ cooling tower strip opening and dismantling of motor for servicing /overhauling, cleaning oiling/greasing and fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, reassembling motors, ensuring proper alignment of the motor with existing compressor / pumps/blower/cooling tower, fixing in position connecting to existing system and testing at site on full load to the entire satisfaction of the Engineer-in-Charge for the following capacities :-(a) 1 HP to 5 HP 1 Phase/3 Phase 50 Hz |
| 59 | (b) 7.5HP to 12.5 HP Three phase 50 Hz |
| 60 | (c)15 HP to 20 HP Three phase 50 Hz |
| 61 | (d) 60 HP Three phase 50 Hz |
| 62 | Disconnecting, dismantling & taking up/down pump set and monoblock pump setsof AC plant of any description and in any position from existing foundation, strip opening and dismantling ofPumps for servicing/overhauling, cleaning oiling/ greasing and fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, reassembling the pumpsensuring proper alignment of pump, fixing in position connecting to existing system and testing at site on full load to the entire satisfaction of the Engineer-in-Charge for the following capacities :-(a) 0.5 HP to 3 HP single phase 50 Hz |
| 63 | (b) 5.0 HPHP Three phase 50 Hz |
| 64 | (c) 7.5 HPHP Three phase 50 Hz |
| 65 | (d)10 HP to 12.5 HP Three phase 50 Hz |
| 66 | (e)15 HP to 20HP Three phase 50 HzNotes :(i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under respective item of overhauling and servicing mentioned here in before. (ii)Burnt out windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) The rates for above items are deemed to include for transportation to & from of pumps/ motors to workshop as approved by Engineer-in-charge for necessary repairs, alignment and testing of pump and motors at workshop& replacement of necessary unserviceable screws/nuts/bots/washers/ packing etc with new one(iv) Re-metaling of side cover of motor and machinery, polishing for housing of bearing all as required at site for smooth and noiseless movement ofrotor impeller shall be measured and paid for separately under appropriate item of Schedule `A’.(v) Re-metaling to pump shaft, polishing and grinding and making to standard size to match with GM Bushes / Neck ring shall be measured and paid separately under appropriate item of Sch`A’ |
| 67 | Taking out & removing old burnt out windings and rewinding of electric motors of following sizes with existing size copper super enameled wire including insulating material such as illuminous paper, Leatherized paper, cotton tape, glass sleeving, insulating varnish etc including testing and refixing to original position for the following capacities. (Note : Rates are inclusive of transportation , labour etc, complete. (a) 0.5 HP to 1.5 HP single phase 50 Hz |
| 68 | (b) 2.0HP to 3.0 HP Three phase 50 Hz |
| 69 | (c) 5.0 HP Three phase 50 Hz |
| 70 | (d) 7.5 HP Three phase 50 Hz |
| 71 | (e)10 HP to 12.5 HP Three phase 50 Hz |
| 72 | (f)15 HP Three phase 50 Hz |
| 73 | (g) 20 HP Three phase 50 Hz |
| 74 | (h)60HP Three phase 50 Hz |
| 75 | Supply only ball Bearing/Roller Bearing of the following Sizes complete all specified and directed by the Engineer-in-Charge.(a) 6202Z |
| 76 | (b) 6204Z |
| 77 | (c) 6313Z |
| 78 | (d) 6312Z |
| 79 | (e) 6307Z |
| 80 | (f) 6308Z |
| 81 | (g) 6309Z |
| 82 | (h) 6310Z |
| 83 | Supply only gun metal bushes suitable for following capacity of pumps of any make/model :-(a)02 to 05 HP Pump |
| 84 | (b)7.5 to 12.5 HP Pump |
| 85 | (c)15 to 20 HP Pump |
| 86 | Supply only of MS star coupling , rubber coupling L – 190 for pump and Motor or as approved by GE. Note :- Fixing/ testing charges of these items are deemed to be included in the rates quoted by the contractor for respective item of BOQ. |
| 87 | Supply only cast iron gland plate for pumps suitable for following capacity of pumps of any make/model:-(a) 5 to 12.5 HP, three phase, 50 Hz |
| 88 | (b) 20 HP, three phase, 50 Hz |
| 89 | Supply only gland bolts made out of high carbon forged steel complete with nuts & washers suitable for following capacity of pumps of any make/model :(a) 5 to 12.5 HP, three phase, 50 Hz |
| 90 | (b) 20 HP, three phase, 50 Hz |
| 91 | Supply only pump shaft all as specified & directed by Engineer-in-Charge, suitable for following capacity of pumps of any make/model:(a) 5 to 12.5 HP, three phase, 50 Hz |
| 92 | (b) 20 HP, three phase, 50 Hz |
| 93 | Supply only of rotor motor shaft all as specified & directed by Engineer-in-Charge, suitable for following capacity of motor of any make/model:-(a) 5HP, three phase, 50 Hz |
| 94 | (b) 7.5 HP, three phase, 50 Hz |
| 95 | (c) 10 HP, three phase, 50 Hz |
| 96 | (d) 12.5 HP, three phase, 50 Hz |
| 97 | (e) 20 HP, three phase, 50 Hz |
| 98 | Supply only pump impeller CI suitable for following capacity of pumps of any make/model:- (a) 5 to 12.5 HP, three phase, 50 Hz |
| 99 | All as per iteno 38 here-in-before but 20 HP, three phase, 50 Hz |
| 100 | Disconnecting and taking down existing unserviceable terminal plate of any description and in any position supply and fixing terminal plate, 3 phase, six wire, bakelite, star / star delta connection as required at site with brass studs, nuts and washer complete all as specified and directed for the following capacity of motors : -(a) 1 HP to 3 HP |
| 101 | (b) 5 HP to 10 HP |
| 102 | (c) 12.5 HP to 20 HP |
| 103 | (d) 60 HP |
| 104 | Dismantling and taking down/removing of damaged fan blades of any description and in any position from electric motors all as directed and Supply and fixing Fan blades fabricated to shape and size of Zink Aluminum cast alloy as per sample for electric motor with key and key grove complete all as directed for the following capacity motors :-(a) 5 HP to 7.5 HP |
| 105 | (b) 10 HP to 12.5 HP |
| 106 | (c) 20 HP |
| 107 | (d) 60 HP |
| 108 | S&Fofcontactor MNX 18 Amp with 1 NO+1NC auxiliary contactscomplete all as specified and directed |
| 109 | S&Fof contactor MNX 40 Amp with 1 NO+1NC auxiliary contactscomplete all as specified and directed |
| 110 | S&Fof contactor MNX 32 Amp with 1 NO+1NC auxiliary contactscomplete all as specified and directed |
| 111 | Supply and fixing in repair of overload relay MN-2, 14-23Amp complete all as specified and directedMake L&T |
| 112 | Supply and fixing in repair of overload relay MN-2, 9-15 Amp complete all as specified and directedMake L&T. |
| 113 | S&F inrepair including testing of electronic timer, time range from 3 seconds to 120 seconds suitable for 240/415 volts 50 HZcomplete all as specified and directed |
| 114 | S&F inrepair copper Lugs/terminal heavy duty of the following size complete all as specified and directed(a) 50 Sqmm |
| 115 | (b) 35 Sqmm |
| 116 | (c) 25 Sqmm |
| 117 | (d) 16 Sqmm |
| 118 | Supply, install, testing and commissioning of motor of capacity 10 HP capacity, RPM 705 suitable for cooling tower of capacity 200 TR complete all as specified and directed. Make - Kirloskar/ABB/CG/Oswal Pumps Ltd |
| 119 | M & L for preparation of old painted surface of LT panel or any other surface of any size & type complete by scrapping / removing old paint / Dirt etc and painting with two coats of synthetic enamel paint including writing details like unitI,II,II, chiller motor, condenser motor etc all as directed, colour and tint as directed by Engr - in - Charge over a coat of primer all as directed. |
| 120 | M & L for cleaning of surrounding area of plant by cutting hedges , grass , surface dressing n exc 15 cm deep complete all as specified and directed. |
| 121 | M & L in replacement of old Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.Note :- Contractor has to take out existing US base frame of motor and fixing new base frame as existing and any other work as directed at site. |
| 122 | M&L in replacement for PCC work Type B1 1:2:4 (20 mm graded stone aggregate) complete all as directed at site |
| 123 | Disconnecting, dismantling and taking out the defective/ non functional desert cooler of any description and in any position and any location , strip opening of desert cooler, cleaning servicing oiling & greasing etc of desert cooler taking out and removing unserviceable/defective parts and internal wiring, replacement of unserviceable & damaged parts and internal wiring, reassembling & testing of the desert cooler complete all as specified and directed.Note :- (i) The replacement of defective/ nonfuctional parts shall be measured & paid separatly as ` supply only\" under respective item of schedule A and fixing charges for new items are deemed to be included under quoted rate.(ii) The rate for above items are deemed to included for transportation to & from of vertical pumps/fan motor to workshop as approved by Engr-in-charge for necessary repairs, alignment and testing of pump and motor at workshop & replacement of necessary unserviceable screws/nuts, bolts/washer/packing etc with new one. |
| 124 | Supply only of the following parts for existing desert cooler of any description, any capacity, any make and in any position complete all as specified and directed.Note :- (i) Make of the parts must be same as per existing desert cooler (ii) The cost of fixing and testing of spare parts is deemed to be included under schedule A item No 16 here-in-before(a) 15 mm dia PVC flexible water pipe complete set for one desert cooler |
| 125 | PVC distributor 3 way for 15 mm dia water distribution. |
| 126 | 1.5 sqmm 3 core PVC insulated copper cable round type suitable for 1100 volts grade. |
| 127 | 2.5 sqmm 3 core PVC insulated copper cable round type suitable for 1100 volts grade. |
| 128 | Regulator for three speed motor as per site requirement. |
| 129 | Submersible pump PVC body for desertcooler single phase, 230 volt AC flow rate 1100LPH, Max head 1850 mm Make:- Balaji or equivalent as approved |
| 130 | Aluminium fan blade (set of three blades) for desert cooler motor of any description suitable for existing motor. |
| 131 | Wood wool pads of required size as apporved (three in each) for desert cooler of any size. |
| 132 | Desert cooler fan motor copper winding of existing make/model/ capacity/sweep, 900 RPM as per site requirement including making connection complete all as specified and directed Make - Crompton. |
| 133 | Desert cooler fan motor copper winding of existing make/model/ capacity/sweep, 1200 RPM as per site requirement including making connection complete all as specified and directed Make - Crompton. |
| 134 | Desert cooler fan motor copper winding of existing make/model/ capacity/sweep 1400 RPM (Exhaust fan kit with fan blade) including making connection complete all as specified and directed Make - Cromption |
| 135 | Chicken wire mess having hexagonal wire mesh (three for each cooler front and both side) 15mm size mesh and 0.5mm dia of wire for supporting to the wood wool pads of existing size suitable for any desert cooler. |
| 136 | Front grills of existing shape and size and made out of 20 SWG PGI sheet suitable for any desert cooler as required on site. |
| 137 | 15mm bore ball brass valves high pressure with polythene float and fly nut complete |
| 138 | 15mm bore Gun metal gate valve with iron wheel head, screwed both end for iron pipe Make NMC/BIR/Leader |
| 139 | PVC connection pipe 15mm size 450mm length complete with PTMT nuts on both ends. |
| 140 | 5A plug top as per requirement, Make : Anchor or equivalent. |
| 141 | 15 A plug top as per requirement, Make : Anchor or equivalent. |
| 142 | Disconnecting, dimanling and taking out the non functional Water Coolers of any description, any capacity toworkshop cleaning , servicing, checking, replacement of unserviceable parts including testing to the entire satisfaction of Engineer - in - Charge complete all as specified and directed.Note :- Nut, bolts, screws are to be replaced and rates are inclusive under quoted rate, Labour for gas charging as required is inclusive under quoted rates . Replacement of new parts shall be measured and paid separately under relevant item of Sch \"A\" as Supply only. |
| 143 | Supply only of the following parts for existing water cooler of any description, any capacity, any make and in any position complete all as specified and directed.Note :- (i) Make of the parts must be same as per existing water cooler (ii) The cost of fixing and testing of spare parts is deemed to be included under schedule A here-in-before(a) Base tray stainless steel for 40/80 and 60/120 ltrs capacity |
| 144 | Base tray stainlesssteel for40 ltrs capacity |
| 145 | Base tray stainlesssteel for60 ltrs capacity |
| 146 | Base tray stainlesssteel for150 ltrs capacity |
| 147 | Side cover set of 3 stainless steel for 40/80 ltrs capacity |
| 148 | Side cover set of 3 stainless steel for 60/120 ltrs capacity |
| 149 | Side cover set of 3 stainless steel for 150/150 ltrs capacity |
| 150 | Water Reservoir tank with chiller made of stainless steel incl copper tube for 40/80 Ltrs capacity |
| 151 | Water Reservoir tank with chiller made of stainless steel incl copper tube for 60/120 Ltrs capacity |
| 152 | Water Reservoir tank with chiller made of stainless steel incl copper tube for 150/150 Ltrs capacity |
| 153 | Water tank chiller\"s top cover made of stainless steel for 40/80 ltrs capacity |
| 154 | Water tank chiller\"s top cover made of stainless steel for 60/120 ltrs capacity |
| 155 | Water tank chiller\"s top cover made of stainless steel for 150/150 ltrs capacity |
| 156 | Air cooled condenser with ventury, copper 3 row suitable for existing make and model for 40/80 ltrs capacity |
| 157 | Air cooled condenser with ventury, copper 3 row suitable for existing make and model for 60/120 ltrs capacity |
| 158 | Air cooled condenser with ventury, copper 3 row suitable for existing make and model for 150/150 ltrs capacity |
| 159 | Relay unit current type suitable for 40 to 150 Ltr Cap water cooler as per existing make and model. |
| 160 | Relay pin type (Potential type) suitable for 40 to 150 Ltr Capacity water cooler as per existing Make and Model. |
| 161 | Thermostat 220 volts suitable for 40 to 150 Ltr as per existing make and model |
| 162 | Over load protector of existing make suitable for 40 to 150 Ltr water cooler |
| 163 | AC electric condenser motor as per existing make and model suitable for 40 Ltr water Cooler. |
| 164 | AC electric condenser motor as per existing make and model suitable for 60 Ltr water Cooler. |
| 165 | AC electric condenser motor as per existing make and model suitable for 150 Ltr water Cooler. |
| 166 | Brass nipple 15 mm dia for inlet and out let connection of water cooler any type/size incl PVC connection 15 mm dia with brass coupling on both ends |
| 167 | Drain pipe PVC flexible ¼\" dia . |
| 168 | End circle clip for Drainpipe 1/4\" dia |
| 169 | Flexible Wiring kit ofPVC insulated copper conductor cable of existing size. |
| 170 | CP brass push cock 15mm dia (ISI marked) inner/outer threadedas directed |
| 171 | Harmetic sealed unit compressor of existing make and model suitable for capcity40/80 Ltrs of water cooler incl vacuum testing and filling of refrigerant gas to required pressure is included under respective itemcomplete all as directed by Engineer - in - Charge. |
| 172 | Harmetic sealed unit compressor of existing make and model suitable for capcity60/120 Ltrs of water cooler incl vacuum testing and filling of refrigerant gas to required pressure is included under respective item complete all as directed by Engineer - in - Charge. |
| 173 | Harmetic sealed unit compressor of existing make and model suitable for capcity150/150 Ltrs of water cooler incl vacuum testing and filling of refrigerant gas to required pressure is included under respective itemcomplete all as directed by Engineer - in - Charge.Note : The cost of fixing brazing to suction and discharge line and testing of compressor at site is deemed to be included under respective item of schedule A. |
| 174 | Fan blade suitable for 40/80 ltrs capacity |
| 175 | Fan blade suitable for 60/120 ltrs capacity |
| 176 | Fan blade suitable for 150/150 ltr capacity |
| 177 | Disconnecting, dimanling and taking out the non functional Refrigerator of capacity 165 to 340 ltrs of any description, Servicing , checking, replacement of unserviceable parts including testing complete all as specified and directed.Note :- Replacement of new parts and shall be measured and paid separately under relevant item of Sch \"A\" as Supply only. |
| 178 | Supply only of the following new parts for existing refrigerator of any description, any capacity of 165 to 340 ltrs & any make and in any positioncomplete all as specified and directed.(a) Main door gasket magnetic type |
| 179 | Thermostat switch with knob 230 volt suitable for single door refrigerator |
| 180 | Thermostate switch with knob 230 volts suitable for double door refrigerator of capacity 165 to 360 ltrs |
| 181 | Overload relay suitable for refrigerator of capacity 165 to 340 Ltr Capacity as per existing Model. |
| 182 | Freezer Zone door suitable for existing make and Model. |
| 183 | Pin type/screw type bulb Make Philip/bajaj/Crompton |
| 184 | Condenser water drain off tray of pvc same as per existing model complete |
| 185 | Door switch 230 volts |
| 186 | Chiller tray plastic suitable for 165 to 340 Ltr Capacity. |
| 187 | Refrigerator freezer coil suitable for as per existingfor 165 ltr to 230 ltrs capacity |
| 188 | Refrigerator freezer coil suitable for as per existingfor above 230 ltr to 360 ltrs capacity |
| 189 | Bulb holder assembly complete |
| 190 | InnerPUF Insulationfor 165 to 230 ltr capacity |
| 191 | Inner PUF Insulationfor above 230 ltr to 360 ltr capacity |
| 192 | PVC inner cabinet moulded in shape suitable for capacity 165 to 230 ltrs |
| 193 | Condesner coil for 165 to 230 ltrs capacity |
| 194 | Condesner coil for above 230 to 360 ltrs capacity |
| 195 | Fan motor suitable for double door refrigerator as per existing. |
| 196 | Thermostat suitable for refrigerator of capacity 165 to 230 ltr as existing |
| 197 | Thermostat suitable for refrigerator of capacity above 230 and upto 360 ltr as existing |
| 198 | PCB for 165 to 230 ltrs capacity as per existing Make and Model |
| 199 | PCB for above 230 to 360 ltrs capacity as per existing Make and Model |
| 200 | Timer for double door refrigerator as per existing make. |
| 201 | Capillary suitable for refrigerator of Capacity 165 to 360 ltr as per existing |
| 202 | Sealed unit compressor suitable for refrigerator of capacity 165 Ltr to 230 Ltr as per existing Make and Model incl vacuum testing and filling of refrigerant gas to the required pressure complete to the entire satisfaction of Engr - in - Charge, Gas charging, brazing to suction and discharge line is included in respective item of Schedule A. |
| 203 | Sealed unit compressor suitable for referigerator of capacity above 230 Ltr to 360 Ltr as per existing Make and Model incl vacuum testing and filling of refrigerant gas to the required pressure complete to the entire satisfaction of Engr - in - Charge, Gas charging, brazing to suction and discharge line is included in respective item of Schedule A. |
| 204 | Vegetable tray of refrigerator suitable for capacity 165 to 360 Ltr Capacity. |
| 205 | Supply of Refrigerant gas (R-134A) in cane complete all as specified and directed. |
| 206 | Supply of Refrigerant gas (R-600A) in cane complete all as specified and directed. |
| 207 | Supply and fixing voltage stabilizer electronic typefor automatic operation single phase naturally air cooled, indoor, type, wall mounted for input variation between 170 V to 250 V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 5.0 KVAcomplete all as specified and directed. |
| 208 | Supply and fixing voltage stabilizer electronic typefor automatic operation single phase naturally air cooled, indoor type, wall mounted for input variation between 170 V to 250 V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 4.0 KVA complete all as specified and directed. |
| 209 | Taking down old unserviceable PVC cable of any conductor and any core complete all as specified and directed |
| 210 | S&F PVC insulated & sheathed copper round cable 1100 volts of size 4.0 sqmm 3 core incl copper thimble/pin type lugs connecting both side and testing complete all as specified and directed. |
| 211 | All as per item No 63 but of Size 4.0 sqmm 4 core |
| 212 | All as per item No 63 but of Size 4.0 sqmm 5 core |
| 213 | Preventive maintenance & routine servicing of split AC ofany type/size/make /model & capacityup to 3TR in any position / work shop as convenient indoor & out door unit by cleaning of dust from condenser, air filter, cooling coils by pressure pump , liquid line filter/capillary tube /expansion valve, refrigerant inlet /out let pipe by Nitrogen and Ethylene tri chloride(ETC),andchecking of all electrical components and compressor etc.Replacement of minor parts such asnut, bolts, screws, washers, brazing, lugs etc and testing proper cooling all as directed.Note:-(i) The replacement of defective / non-functional parts except compressors during servicing shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under quoted rate of this item. (ii) Refrigerant gas for charging if required, shall be issued by department under Sch B. However, vacuumising and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor during one time servicing & preventive maintenance of unit. |
| 214 | Preventive maintenance & routine servicing of Window type AC ofany type/size/make /model & capacity at any positionincluding cleaning & washing condenser assembly by chemical such as suction air filter & coil, brazing the discharge and suction line andchecking & retightening of all electrical connections.Replacement of minor part such asnut, bolts, screws, washers incl replacment of unserviceable partsof capacity 1.5/2.0 TR of single phase AC etc and testing complete all as specified and directed.NOTE :-(i) The replacement of defective / nonfunctional parts except compressors during servicing shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under quoted rate of this item. (ii) Refrigerant gas for charging if required, shall be measured and paid separately. However, vacuumising and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor during one time servicing & preventive maintenance of unit. |
| 215 | Supply only following items ofAir conditioning split/windowtype AC of capacity 1.5/2/3TRof any make/model/ capacity including checking of defects and rectified. (a) Supply only in replacement with new Starting capacitor 80/100 mfd suitable for 240 Volts 50 HZ AC supply. |
| 216 | Supply only in replacement with new Starting capacitor 100/120 mfd suitable for 240 volts 50 HZ AC supply |
| 217 | Supply only in replacement with new Running capacitor of 36 mfd +5/6 mfd suitable for 440 volts 50 HZ ACsupply |
| 218 | Supply only in replacement with new Running capacitor of 45/50/60 + 5/6 mfd suitable for 440 volts 50 HZ AC Supply |
| 219 | Supply only in replacement with new Running capacitor of 10 mfd suitable for 430 volts 50 HZ AC supply |
| 220 | Supply only in replacement with new Running capacitor of 1 to 2.5 mfd suitable for 240 volts 50 HZ AC supply |
| 221 | Supply only in replacement with new Running capcitor of 3 to 4 mfd suitable for 240 volts 50 HZ AC supply |
| 222 | Supply only in replacement with new PVC braded drain pipe of size 15 mm inner dia |
| 223 | Supply only in replacement with new PVC braded drain pipe of size 20 mm inner dia |
| 224 | Supply only in replacement with new Electronic sensing unit as per sample (PCB) with hand set suitable for PCB and display unitsuitable for Split AC/Window AC1.5/2.0 TR of capacity, model and make as per existing all as directed. |
| 225 | Supply only in replacement with new Electronic sensing unit (PCB) as per sample with hand set suitable for PCB anddisplay unitsuitable for Split AC 3.0 TR inverter type of capacity, model and make as per existing all as directed. |
| 226 | Supply only in replacement with new Electronic sensing unit (PCB) as per sample with hand set suitable for PCB anddisplay unitsuitable for Split AC 3.0 TR capacity Non inverter type, model and make as per existing all as directed. |
| 227 | Supply only in replacement with new Electronic sensing unit (PCB) as per sample with hand set suitable for PCB anddisplay unitsuitable for Split AC 3.0 TR cassete type of any model and make as per existing all as directed. |
| 228 | Supply only in replacement with new Electronic sensing unit (PCB) as per sample with hand set suitable for PCB anddisplay unitsuitable for hot and cool type Split AC 1.5/2 TR of any model and make as per existing all as directed. |
| 229 | Supply only in replacement with new Air cooled copper condenser coil as per sample suitable for split type AC 1.5/2TR complete all as specified and directed. |
| 230 | Supply only in replacement with new Air cooled copper condenser coil as per sample suitable for window type AC 1.5/2TR complete all as specified and directed. |
| 231 | Supply only in replacement with new Air cooled copper condenser coil as per sample suitable for split type AC 3TR complete all as specified and directed. |
| 232 | Supply only in replacement with new Air cooled copper condenser coil as per sample suitable for split type Cassete AC 3TR including complete all as specified and directed. |
| 233 | Supply only in replacement with new Electric fan motor as per sample suitable for out door unit 1.5/2 TR split AC Single Phase complete all as specified and directed at site.Make :- LG/Blue star/ Voltasor as per existing make of AC at site |
| 234 | Supply only in replacement with new Electric fan motor as per sample suitable for out door unit 1.5/2 TR window AC Single Phase complete all as specified and directed at site.Make :- LG/Blue star/ Voltasor as per existing make of AC at site |
| 235 | Supply only in replacement with new Electric fan motor as per sample suitable for out door unit 3 TR Split AC Single Phase complete all as specified and directed at site.Make :- LG/Blue star/ Voltasor as per existing make of AC at site |
| 236 | Supply only in replacement with new Electric fan motor as per sample suitable for out door unit 3 TR Split AC Three Phase complete all as specified and directed at site.Make :- LG/Blue star/ Voltasor as per existing make of AC at site |
| 237 | Supply only in replacement with new capillary tube of size as per sample suitable for split AC 1.5TR/2TR/3TR and window type AC of any make complete all as specified and directed. |
| 238 | Supply only in replacement with new Liquid line copper filter as per sample suitable for 1.5/2 TR split/window AC. |
| 239 | Supply only in replacement with new Liquid line copper filter as per sample suitable 3 TR split AC. |
| 240 | Supply only in replacement with new Over load Relay as per sample suitable for any type split type 1.5/2 TR Capacity. |
| 241 | Supply only in replacement with new Over load Relay as per sample suitable for any type split type 3 TR Capacity. |
| 242 | Supply only in replacement with new Condenser side fan blade as per sample suitable for existing SplittypeAC\"s of Capacity 1.5/2 TR. |
| 243 | Supply only in replacement with new Condenser side fan blade as per sample suitable for existing SplittypeAC\"s of Capacity 3 TR. |
| 244 | Supply only PVC fan blower assembly as per sample for 1.5 /2TR window / split AC\"s Non inverter type any make as existing. |
| 245 | Supply only in replacement with new Blower motor as per sample suitable for split type AC of 3 TR Capacity Non inverter as per existing make and model. |
| 246 | Supply only in replacement with new Blower motor as per sample suitable for split type AC of 1.5/2 TRcapacity inverter type as per existing make and model. |
| 247 | Supply only in replacement with new Blower motor as per sample suitable for split type AC of 3 TRcapacity inverter type as per existing make and model. |
| 248 | Supply only in replacement with new Swing Motor suitable for flapper of any type Split AC 1.5 / 2 TR Capacity. |
| 249 | Supply only in replacement with new Swing Motor suitable for flapper of any type Split AC 3 TR Capacity. |
| 250 | Supply only in replacement with new flapper suitable for Split AC as per sample for capacity 1.5 to 3 TR |
| 251 | Supply only in replacement with new PVC Grills as per sample and for any make window AC. |
| 252 | Supply only in replacement with new Thermostate switch with knob 230 volts for Window AC |
| 253 | Supply only in replacement with new Check valve any dia for upto 3 TR capacity Split AC\"s as per sample. |
| 254 | Supply only in replacement with new Expansion valve complete set as per sample suitable for 1.5 / 2 TR Split AC. |
| 255 | Supply only in replacement with new Expansion valve complete set as per sample suitable for 3 TR Spllit AC. |
| 256 | Supply only in replacement with new Ventury as per sample made of thermo-coal insulationsuitable for Window AC . |
| 257 | Supply only in replacement with new Pre-air filter made up of PVC for indoor unit as per sample of split AC suitable for any capacity make and description complete |
| 258 | Supply only in replacement with new Brass service valve of 5/8\" dia with flare unit as per sample for split type AC. |
| 259 | Supply only in replacement with new Brass service valve of 3/8\" dia with flare unit as per sample for split type AC. |
| 260 | Supply only in replacement with new Brass service valve of 1/2\" dia with flare unit as per sample for split type AC. |
| 261 | Supply only in replacement with new Brass service valve of 1/4\" dia with flare unit as per sample for split type AC. |
| 262 | Supply only in replacement with new Brass service dead nut suitable for any type of Acs as per sample. |
| 263 | Supply and fixing in replacement with new copper tubing of special annealed pressure copper of size 3/8\" bore |
| 264 | Supply and fixing in replacement with new copper tubing of special annealed pressure copper of size 5/8\" bore |
| 265 | Supply and fixing in replacement with new copper tubing of special annealed pressure copperof size 1/4\" bore |
| 266 | Supply and fixing in replacement with new copper tubing of special annealed pressure copper of size 1/2\" bore |
| 267 | Supply and fixing in replacement with new Evaporator complete indoor unit as per sample body made of PVC with GI base plate suitable for 1.5TR/2TR split AC complete all as specified and directed. |
| 268 | Supply and fixing in replacement with new Harmetic sealed Reciprocating compressor as per sample suitable for 1.5 TR Split Acs 230 volts of existing make complete complete all as specified and directed. Note: Vaccumising and pressure testing is inclusive preventive maintenance of unit under respective item of Sch \"A\" |
| 269 | Supply and fixing in replacement with newHermetic sealed Reciprocating compressor as per sample suitable for 2 TR Split Acs 230 volts of existing make complete all as specified and directed. Note: Vaccumising and pressure testing is inclusive preventive maintenance of unit under respective item of Sch \"A\" |
| 270 | Supply and fixing in replacement with newHarmetic sealed Reciprocating compressor as per sample suitable for 3 TR Split AC Single Phase 230 volts of existing make complete complete all as specified and directed.Note: Vaccumising and pressure testing is inclusive preventive maintenance of unit under respective item of Sch \"A\" |
| 271 | Supply and fixing in replacement with newHarmetic sealed Reciprocating compressor as per sample suitable for 3 TR Three Phase Split Acs 230 volts of existing make complete complete all as specified and directed. Note: Vaccumising and pressure testing is inclusive preventive maintenance of unit under respective item of Sch \"A\" |
| 272 | Supply and fixing in replacement with new Harmetic sealed Reciprocating compressor as per sample suitable for 1.5 TR Single Phase Window Acs 230 volts of existing make complete complete all as specified and directed. Note: Vaccumising and pressure testing is inclusive preventive maintenance of unit under respective item of Sch \"A\" |
| 273 | Supply and fixing in replacement with newHarmetic sealed Reciprocating compressor as per sample suitable for 2 TR Single Phase Window Acs 230 volts of existing make complete complete all as specified and directed. Note: Vaccumising and pressure testing is inclusive preventive maintenance of unit under respective item of Sch \"A\" |
| 274 | Supply and fixing in replacement with new Rotary compressor as per samplesuitable for 1.5 TR Split AC Single phase 230 volts of existing make complete complete all as specified and directed. Note: Vaccumising and pressure testing is inclusive preventive maintenance of unit under respective item of Sch \"A\" |
| 275 | Supply and fixing in replacement with newRotary compressor as per samplesuitable for 2 TR Split AC Single phase 230 volts of existing make complete complete all as specified and directed.Note: Vaccumising and pressure testing is inclusive preventive maintenance of unit under respective item of Sch \"A\" |
| 276 | Supply and fixing in replacement with new Rotary compressor as per sample suitable for 3 TR Split AC Single phase 230 volts of existing make complete complete all as specified and directed. Note: Vaccumising and pressure testing is inclusive preventive maintenance of unit under respective item of Sch \"A\" |
| 277 | Supply and fixing in replacement with new Rotary compressor as per sample suitable for 3 TR Split AC Three phase 230 volts of existing make complete complete all as specified and directed.Note: Vaccumising and pressure testing is inclusive preventive maintenance of unit under respective item of Sch \"A\" |
| 278 | S&Fin replacement with new out door cover at any location and floor made of MS Angle and GI Sheet with proper fixing screw to cover the entire out door unit as per sample , fixed on wall with neccessory grouting MSbolts,washer duly painted and making good of disturbed surfaces, suitable for installing outdoor unit of 1.5/2.0/3.0 TR AC complete all as specified and directed. |
| 279 | Supply and fixing in replacement with new Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and directed.. |
| 280 | S & F in replacement with new Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 32 Amps complete all as specified and directed.. |
| 281 | Supply and fixing in replacement with new 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.. |
| 282 | Supply and fixing in replacement with new TPN / FP 32 Amp 415V 10KA \"B\" curve miniature circuit breaker (MCB)and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.. |
| 283 | Supply and fixing in replacement with new power contactor MNX-12 of rating 12 amps four pole suitable for 415 volts for AC complete all as specified and directed.. |
| 284 | M & L necessary tools for finding leakage in condenser coil and rectify defects including welding/brazing as necessary by arranging N2 gas for checking and mutein gas for welding etc all as directed and testing for satisfactory operation of window/split type AC complete all as specified and directed complete all as specified and directed.. |
| 285 | S & F in repair Voltage Monitor three phase protection device for three phase system having protection against High, Low Voltage , Single Phasing and Reverse phase sequence as per sample Make : Voltas or equivalent. |
| 286 | Repair / Maint of PCB of any type AC as per Sample suitable for 1.5 / 2/ 3 TR split / window AC complete all as specified and directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy