|
| 1 | 1 Paver Block Work |
| 2 | 2.25Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers notexceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 3 | 2.31Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared |
| 4 | 16.78.3Construction of granular sub- base by Providing close graded Material conforming to specifications,mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads& lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface andcompacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With material conforming to Grade - III ( size range 26.5 mm to 0.075 mm) having CBR Value - 20 |
| 5 | 16.91.1Providing and laying factory made chamfered edge Cement Concrete paver blocksin footpath, parks,lawns, drive ways or light traffic parking etc, of required strength,thickness & size/ shape, made by table vibratory method using PU mould, laid inrequired colour & pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sand beddinglayerthrough vibratory compaction by using plate vibrator, filling the joints with sand andcutting of paverblocks as per required size and pattern, finishing and sweepingextra sand. complete all as per directionof Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour,design& pattern. |
| 6 | 4.1.4Providing and laying in position cement concrete of specified grade excluding the cost of centering andshuttering - All work up to plinth level:1:2:4 )1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) |
| 7 | 7.1.1Random rubble masonry with hard stone in foundation and plinth including levelling up with cementconcrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinthlevel with:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 8 | 50.2.25.1Filling with contractor\"s own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge |
| 9 | 50.6.7.2Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cementmortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. |
| 10 | 13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand). |
| 11 | 50.18.8.9.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes with one step PVC Solvent cement and testing of joints complete as perdirection of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 110 mm pipe 4 kgf/cm2 |
| 12 | 50.18.8.8.2Providing and fixing PVC pipes, fittings, including fixing the pipe with clamps at 1.00 m spacing. thisincludes jointing of pipes with one step PVC solvent cement and testing of joints complete as per thedirection of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.75 mm pipe 4 kgf/cm2 |
| 13 | 50.18.8.3.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete asper direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the walletc. 25 mm pipe 10kgf /cm2 |
| 14 | 50.18.8.6.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete asper direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the walletc. 50 mm pipe 6 kgf/cm2 |
| 15 | 50.18.8.7.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes with one step PVC solvent cement and testing of joints complete as perdirection of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc63 mm pipe 4 kgf/ cm2 |
| 16 | od361371/2023_2024Providing and Displaying Cycus revoluta specimen plant, having 45 to 50 fresh and healthy, leaveshaving 30cm to 35cm circumfrance of base stem well developed in 40 cm challi, as per direction ofthe officer-in-charge. sago palm |
| 17 | od361372/2023_2024Supply and stacking of Eugenia jambolana (Jamun) plant of height 150-165 cm. in big poly bags of size25 cm as per direction of the officer-in-charge. |