| 1 | Removal of spoil: Labour only for removal of spoil mixed with excavated earth, broken bricks, concrete rubbish and debris, broken glasses, cut pieces of tarfeltetc, from work site to a distance of 1.50 km. outside the factory or as directed by the EIC/SIC (20% deduction in measurement will be made from the volume of spoil ). |
| 2 | Earth work in excavation : Labour only for earth work in excavation in foundation, in foundation trenches etc., not exceeding 1.50 m wide and not exceeding 1.5 min depth getting out in hard or dense soil as ordered by EIC/SIC. |
| 3 | P.C.C. (1:2:4) : M & L for providing plain cement concrete type-B1, 1:2:4 mix ( using 12.5 mm graded stone aggregate ) as in sub-base, filling and mass concrete, topping of floor as ordered by EIC/SIC. |
| 4 | Brick work (1:6): M & L for brick work with old size subclass\"B\" bricks, straight or curved on plan exc 6m mean radius with (1: 6) cement morter as ordered by EIC/SIC. |
| 5 | Cutting holes:Labour only for Cutting holes not exc. 150 sq.cm into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as require and ordered by EIC/SIC. |
| 6 | M.S small articles : S & F for providing mild steel straps, clamps,nut bolts, wall ties; hooks for hanging fans; M. S. nozzle, plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articlesetc, as small articles, to be fixed in position as required as ordered by EIC/SIC. |
| 7 | M.S. framed work: S & F for framed work of trussed, purlins, joists, rails and fastenings and heavy bracket framing, steel gate, steel door (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. or others made of mild steel of approved sections including cutting, drilling, welding etc. at any position as required complete in all respect as ordered by EIC/SIC. |
| 8 | Expanded metal: M & L for providing expanded metal, cut to length,bent to shape required and tying with and including annealed mild steel wire not less than 0.9 mm dia (not exc. 4 kg weight per sqm )fixingin the mouth of nozzle of valley gutter or as other required position as directed by EIC/SIC. |
| 9 | Translucent sheeting : M & Lfor roof / north light covering with 2 mm thickfiber glass reinforced translucent sheeting fixed withself tapping screws or as specified any height as north light portion oras ordered by EIC/SIC. |
| 10 | M. S. sheet gutter: M & L for 2.5mm thick plain mild steel sheeting valley gutter with welded joints and fixed in position properly all as specified as ordered by EIC/SIC. |
| 11 | Asbestos cement sheeting: M & Lfor 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc. fixed with L-type or screws J-type or cranked hook complete all as ordered by EIC/SIC. |
| 12 | Cutting grooves: Labour only for cutting grooves in brick wall, 75 mm wide and 65 mm deep and shaping horizontal face of groove making good with cement mortar (1:3) complete as ordered by EIC/SIC. |
| 13 | Taking down and refixing of roof sheeting: Taking down and refixing forroof covering with corrugated or semi-corrugated sheets in roofs, fixed with \"J\" or \"L\" hook or coach screws as required for site condition and as ordered by EIC/SIC. |
| 14 | Surface Painting:M & L for Wire brushing and cleaning top surface of existing tarfelting surface, ms gutter etc., including flashings and junction of parapets, etc., and surface painting,with a layer of blown grade bitumen of any penetration applied hot @ 1.7 kg per sq. m, to arrest any hole (for tarfelting surface) etc. complete as ordered. |
| 15 | Preparation of old surface with primer : M & L fornecessary preparation of old decorated steel surfaces with primer for making it suitable for painting work,as ordered by EIC/SIC. |
| 16 | Preparation of new surface with primer : M & L fornecessary preparation of new decorated surfaces with primer for making it suitable for painting work,as ordered by EIC/SIC. |
| 17 | Acid resistance Painting : Labour only forapplying two coats of acid resisting paint at any height and at any position,as ordered by EIC/SIC. |
| 18 | Acid resistance Paint : Supplying for painting of acid resisting paint ofmake: Asian / Berger / Shalimar or substantialaly equivalent make and shade as ordered by EIC/SIC. |
| 19 | Pre-colour coated steel sheet: S & F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick (total coated thickness) of any colour having tensile (yield) strength of 550 mpa minimum, coated with aluminium zinc (az 150) @ 150 gm/sqm of coating (total both surfaces) as in roof covering / clading to wall, ridges (straight / curve ) etc. fixed with self tapping screws as specified & as directed by the EIC/SIC. (test certificate of the materials should be submitted by the firm before any payment). |
| 20 | Taking down gutter & Rain water pipe: Taking down eaves gutters / rainwater pipes CI / PVC (any size or pattern or dia), including all fittings,heads, shoes, bends, swan-necks, etc., including cleaning for refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete as ordered. |
| 21 | Cement plaster(1:6): M & L for providing 12 mm thick cement plaster 1:6 mixon fair faces of brick work or concrete surfaces at any height as ordered by EIC/SIC. |
| 22 | Taking down plastering : Labour only for taking down cement or cement lime plaster of any description, flush pointing, any painting etc. from brick wall including raking out joints, hacking for key, scrubbing down with water etc. complete as ordered by EIC/SIC. |
| 23 | Screed bed of 20 mm: M & L for providing screed bed of 20 mm thick in cement mortar ( 1:6) etc. after taking out existing PVC / tarfelt or other floor finish material (if any), complete in all respect as ordered by EIC/SIC. |
| 24 | Hacking out old broken glass from metal frames : Labour only for hacking out old broken glass any thickness, size, quality or description frommetal frames including punching or drilling out old glazing pins, spring clips and removing to store all as complete and as ordered by EIC/SIC. |
| 25 | Steel painting two coat: M & L for applying two coats of synthetic enamel paint finished glossy of 1st quality; Make: Asian / Berger / ICI or substantially equivalent make, and approvedshade over a coat of priming with red lead primerafter necessary preparation of decorated steel surfaces of any description over 10 cm width or girth as ordered by EIC/SIC. |
| 26 | Refixing PVCpipes: Labour only for refixing of old PVC SWRpipes of 110mm dia. including bends of dia.etc. upto 110mm, in any position and height, complete as ordered by EIC/SIC. |
| 27 | Refixing CI/stonewarepipes: Labour only for refixing of old cast iron/stonewarepipes of 150mm dia.with spigot and socket including bends of dia. etc., in any position and height, complete as ordered by EIC/SIC. |
| 28 | PVC rain water pipe: S & F of 110 mm dia PVC rain water (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls in any position complete as ordered by EIC/SIC. |
| 29 | PVC (SWR) bend: S & F of 110 mm dia bends fixed in position complete as ordered by EIC/SIC. |
| 30 | PVC door bend of 110mm dia: S & F 110mm dia. PVC(SWR) door bendsofof any radius to be fixed in position as ordered by EIC/SIC. |
| 31 | PVC (SWR) Tee: S & F of 110 mm dia door tee fixed in position complete as ordered by EIC/SIC. |
| 32 | Demolition of PCC : Labour only for demolition of cement concrete of any description and in any position and removing the same out off the work site as orderd by EIC/SIC. |
| 33 | Demolition of brick work: Demolition of brick work or stone/boulder masonry of any typebuilt in cement morter including all quoins, arches, pillars etc as order by EIC & SIC. |
| 34 | Dismantling of roof sheet: Labour only for dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Galvalume sheets,Nainital or similar pattern roof coverings in any position complete as ordered by EIC/SIC. |
| 35 | Cleaning of roof: Labour only for cleaning of roof (flat or sloped), valley / eaves gutter, rain water pipes (any size or pattern) any height or position as and when required throughout the contract period or minimum315 man days whichever is earlier) in different buildings under RFI maintenance, including removal of leaves from roofs upto inside bins as ordered by EIC/SIC. |
| 36 | Water proofing treatment:S & F of polymeric bituminous water proofing membrane of 2 mm thick (approx.) of wt. 2.25 kg./ sqm to be laid over ( after applying)one layer of blown bitumen on existing surface after necessary preparetory work and then another layer of blown bitumen to be applied over the newly laid water proofing membrane ( bitumen Grade for both the layers should be 30/40 and total quantity of bitumen on both layers should be minimum @ 2.4 kg / sqm )all complete as orderedby EIC/SIC. |
| 37 | Credit materials :-(a) Old steel scrap (CGI, PGI sheets/ CI RW Pipes / bends / shoes & Steel gutter, steel angle, Flat etc). (deviation + 25% ) |