Tender For Repair Replacement Of Internal Wiring Electrical Fittings Fixtures Renewal Of Bldg Earthing Ceiling Fans Exhaust Fans Geysers Spit Window Type Air Conditioners Water Coolers Deep Freezer And Allied Works In Ro Md Otm Accns At Afsod

Issued by Statutory Bodies & Commissions/Committees · bangalore, Karnataka
Tender Value
34 Lakhs
Estimated cost
Bid Submission
03 Oct 2024
0 days left
EMD
68000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
bangalore → Karnataka
EMD Exemption
Available
Quantity
Not Available

Project Description

Repair Replacement Of Internal Wiring Electrical Fittings Fixtures Renewal Of Bldg Earthing Ceiling Fans Exhaust Fans Geysers Spit Window Type Air Conditioners Water Coolers Deep Freezer And Allied Works In Ro Md Otm Accns At Afsod

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 14-Sep-2024 8201Corrigendum1 BOQ 26-Sep-2024
2 26-Sep-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-Oct-2024

BOQ

Name of Work : REPAIR / REPLACEMENT OF INTERNAL WIRING, ELECTRICAL FITTINGS / FIXTURES RENEWAL OF BLDG EARTHING, CEILING FANS, EXHAUST FANS, GEYSERS, SPIT / WINDOW TYPE AIR CONDITIONERS, WATER COOLERS, DEEP FREEZER AND ALLIED WORKS IN R/O MD & OTM ACCNS AT AFSOD / 13 PARA SF AND NAVY AREA UNDER GE (NORTH) BANGALORE.
Sl. No. Item Description
1Taking down carefully aluminium / copper wiring / power point wiring (light, fan, call bell socket or power circuits) completeand making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge.
2Point wiring completewith 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concealed in walls incl MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls withlaminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following One light point controlled by one switch
3All as per item No. 2 above but forOne fan point controlled by one switch / regulator
4All as per item No. 2 above but forOne light point controlled by 2 way switch
5All as per item No. 2 above but forOne 3 pin socket out let 5 Amps on independent board
6All as per item No. 2 above but forOne bell / buzzer point controlled by bell push
7All as per item No. 2 above but forOne 3 pin socket out let 5 A on same board
8Poinrt wiring completewith 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concelaed type wiringincl GI/ MS brandedsunken boxes of suitable module concealedon walls including modular frame and cover of suitable modulefixed with cadmium plated iron screws for housing modular typeswitches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following One light point controlled by one switch
9All as per item No. 8 above but forOne fan point controlled by one switch / regulator
10All as per item No. 8 above but forOne light point controlled by 2 way switch
11All as per item No. 8 above but forOne 3 pin socket out let 5 Amps on independent board
12All as per item No. 8 above but forOne bell / buzzer point controlled by bell push
13All as per item No. 8 above but forOne 3 pin socket out let 5 A on same board
14All as per item No 2 but concealed wiring drawn through existing PVC conduit.One light point controlled by one switch
15All as per item No. 14 above but forOne fan / Exhaust point controlled by one switch / regulator
16All as per item No. 14 above but forOne light point controlled by 2 way switch
17All as per item No. 14 above but forOne 3 pin socket out let 5 Amps on independent board
18All as per item No. 14 above but forOne bell/buzzer point controlled by bell push
19All as per item No. 14 above but forOne 3 pin socket out let 5 A on same board
20Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through non-metalic existing PVC conduit medium density ISI markedincl accessories surface type run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
21Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductorcable as earth continuity conductor, drawn through existing non metallic rigid PVC conduit and conduit accessories all as specified and as directed.
22Point wiring completewith 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC Casing & CapingISI marked incl accessories surface type wiringincl 1.6 mm thick MS sunken boxes concealedon walls includinglaminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following One light point controlled by one switch
23All as per item No. 22 above but forOne fan point controlled by one switch / regulator
24All as per item No. 22 above but forOne light point controlled by 2 way switch
25All as per item No. 22 above but forOne 3 pin socket out let 5 Amps on independent board
26All as per item No. 22 above but forOne bell/buzzer point controlled by bell push
27All as per item No. 22 above but forOne 3 pin socket out let 5 A on same board
28Point wiringcomplete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic PVC conduit medium density ISI markedincl accessories concealedtype Modular/normal run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheetconcealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
29Point wiring completewith 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC casing capingISI marked incl incl accessories surface type wiring run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheetconcealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.Note for Item No 2 to 9 :-(i) The earth wire for the points in the same circuit can be looped from point to point(ii) Earth wire shall be taken inside the conduit(iii)Cost of terminal box is deemed to be included in the item rate quoted for point wiring(iv) Cost of a circuit ofany length of cablefrom DB to any switch/ socket board to be included in point wiring.
30S&F in replacement of LED batten suitable for indoor applications 20 Watts,4 feet with extruded aluminiumhousing & integrated LED channelcomplete with all accessories including taking out old fittings all as specified and directed. Make: Bajaj, Cat No.BCLAB20 WH LED P or equivalent Makes & model
31S&Fin replacement of LED batten suitable for indoor applications 10 Watts, 2 feet with polycarbonate housing & integrated LED channel with white arcylic covercomplete with all accessories including taking out old fittings all as specified and directed. Make: Bajaj, Cat No.BCLSB 10 WH or equivalent Makes &model
32S&Fin replacement of 2 x 2 Recess mountedLED Luminaire36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings as specified and directed. Make: Bajaj, Cat No : BZRSQL 36W GZi WH or equivalent Makes & model
33S&Fin replacement of 1 x 1 Surface mountedLED Luminaire24 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings as specified and directed. Make: Bajaj, Cat No : BZSSQL 24W LED WHI or equivalent
34S&Fin replacement of Bulkhead LEDluminaries 10 watt energy efficient solution for upgrading convertional with IP 65 ncluding taking out old fittings as specified and directed. Make: Bajaj, Cat No : BIBWP10WLED or equivalent
35Supply and Fixin replacement of Modular switch 1 way 6A,1 module
36Supply and fixin replacement of Modular switch 1 way 16A, 1 module
37Supply and fixin replacement of Modular switch 2 way 6A,1 module
38Supply and Fixin replacement of Modular Bell push 6A 1 module
39Supply and fixin replacement of modular Socket, 6A - 2/3 pin combined 2 module
40Supply and fixin replacement of modular Socket 6A/16A - 2/3 pin combined 2 module,
41Supply and fixin replacement of modular type Fan step regulator, 120W - 2 module
42S&F in replacement of Switch piano flush button single pole two way 5 Amps all as specified and as directed.
43S&F in replacement of Angle holder PVC/polycarbonate type all as specified and as directed
44S&F in replacement of switch piano flush type single pole one way 5 Amps
45S&F in replacement of switch socket combination5 pin2 in 1, 5 A Flush typeall as specified and asdirected
46S&F in replacement of switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal all as specified and asdirected
47S&F in replacement ofsocket outlet 2 in 1, 3 pin 5 A all as specified and asdirected
48S&F in replacement of bell push flush type 5A all as specified and asdirected .
49S&F in replacement ofMCB SPN 240 volts 32/40 Amps complete all as specified and as directed
50S&F in replacement of MCB single pole 240 volts 10/16/20/32 Amps complete all as specified and as directed
51S&F in replacement ofMCB TPN 415 volts, 10KA \"C\" curve 63 Amps complete all as specified and as directed
52S&F in replacement ofMCB TPN 415 volts, 10KA \"C\" curve100 Amps complete all as specified and as directed
53S&F in replacement of MCB DB SPN 4 way double door type 240 volts with 200 Amps rated busbaras specified and as directed.
54S&F in replacement of MCB DB SPN 8 way double door type 240 volts with 200 Amps rated busbaras specified and as directed.
55S&F in replacement ofMCB DB TPN 4 way with double door type415 volts with 200 Amps rated busbar for housing MCBs as specified and as directed.
56S&F in replacement ofceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed
57S&F in replacement of stepped type electronic fan regulator flush Switch/socket type all as specified and as directed
58S&F in replacement ofDing Dong bellAC 230 volts single pole.
59Removing of old existingand provision of new sub main wiring1100 volts grade multistranded FRLS copper conductors, two runs of single core 6 Sqmm along with 6 Sqm PVC insulatedsingle core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed
60Removing of oldexistingand provision of new sub main wiring1100 volts grade multistranded FRLS copper conductors, two runs of single core 4 Sqmm along with 4 Sqm PVC insulatedsingle core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed
61Removing of oldexistingand provision of new sub main wiring1100 volts grade multistranded FRLS copper conductors, two runs of single core 2.5 Sqmm along with 2.5 Sqm PVC insulatedsingle core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit for power point all as specified and as directed
62M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed.
63S&F LED lamp suitable to fit in angle holder of capacity 09 watt. Make: Bajaj or eqv in Philips/Havells/CG.
64Supply and fixing30 WLED bldg securitylight fittingwith pressure die cast housing along with prismatic polycarbonate difuser with IP 66protection including taking out old fittings. Make:- Bajaj, Cat No.:- ENXT P 30L WH SY PC SD or Equivalent Makes & model
65S&F Bracket made out of GI tubing medium grade 25 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm, nuts, bolts, washers etc and including before fixing applying two coats of aluminum paintover a coat of red oxide primer including removing the old existing GIbracket from bldg complete all as specified and directed.
66S&F in replacement PVC Fresh air fan of 200mm sweep 1200/1400 RPM with louver. Make CG/Usha/ Orient/Phillips/Bajaj.
67S&F in replacement of Single pole & neutral enclosure 20 Amps & 240 V with two pin and earth plug and socket complete with one single pole MCB 20 Amps.
68Inspection, taking down, dismantling of geysers of any type/capacity, cleaning, descaling, reassembling & reinstallation on the old place incl hydraulic pressure test of container with hand operated hydraulic pump complete, brazing inner tank, internal wiring and reinstallation after necessary repair / replacement of old parts all as specified & as directed. Note : Replacement of old parts shall be measured & paid separately.
69Supply only stainless/Mild steel inner tank of capacity 25 ltrs unit including internally assembly of any size and type complete all as specified & as directed.
70Supply onlyinternal assembly/apparatus rod unit of any size and type of capacity 25 ltrs complete all as specified & as directed.
71Supply only heating element of 2 KW rating triangular/round typeas per existing size and type including rubber washers all as specified & as directed.
72Supply only heating element of 2 KW rating Hexagonal spiral/bend type as per existing size and type including rubber washers all as specified & as directed.
73Supply only Thermostat/auto cut off of suitable size and type for 25/50 Ltrs capacity of any size.
74Supply only Indicator lamp red and green type square/round.
75Supply only Safety valve/high pressure valve / NRV of exisiting type ISI marked.
76Supply only PVC insulated Copper cable flexible 3 coreof size 40/0.0076ISI marked.
77Supply only outer cover of geyger for capacity 25 ltrs unit complete with all fitting and fixtures as specified & as directed.
78Supply only outer cover of geyger for capacity 50 ltrs unit complete with all fitting and fixtures as specified & as directed.
79Supply only stainless/Mild steel inner tank of capacity 50 ltrs unit complete with all fitting and fixtures all as specified & as directed.
80Supply onlyinternal assembly/apparatus rod unit of any size and type of capacity 50 ltrs complete all as specified & as directed.
81S&F in replacement of Thermostat/auto cut off of suitable size and type for 25/50 Ltrs capacity of any size.
82S&F in replacement of heating element of 2 KW rating triangular/round typeas per existing size and type including rubber washers all as specified & as directed.
83S&F in replacement of heating element of 2 KW rating Hexagonal spiral/bend type as per existing size and type including rubber washers all as specified & as directed.
84S&F in replacement of PVC flexible pipe 16 mm dia 450mm long with 2 Nos of brass ferrule & rubber washer for hot and cold water all as specified & as directed. (Set of 2)
85M&L for Preparation old painted surface & painting the geyser complete after cleaning & applying the same one coat of spray paint of white enamel, writing MES No incluingtaking down and refixing in same or other place complete all as specified & as directed by Engr -in-Charge.
86Taking down ceiling fan 1200mm/1400mm and wall mounted fan 300/450 mm sweep from position by duly disconnecting electric lines, preparing the surfaces, filling cavities with filler, after cleaning all dust, spray painting with one finishing coat of synthetic enamel paint including writing MES NO and replacing the split pin,rubber pully etc., includingrefixingand connecting the same complete all as specified and as directed.
87Inspection, disconnecting electric connecting and dismantling of ceiling fan/exhaust/wall mounted fan of any type/size, cleaning including oiling and greasing the bearing, tighting of nuts and bolts and refixing on the old place complete after necessary repair / replacement of old parts all as specified & as directed. Note : Replacement of old parts shall be measured & paid separately.
88Supply only ball bearing of various sizes / make as required for ceiling fans/wall mounting / exhaust fan includinggreasing complete all as specified and as directed.
89Supply only Gun metal bush of any size/make suitable for ceiling fans all as specified and as directed.
90Supply only capacitor 2.5 Mfd suitable for ceiling / exhaust /wall mounting fans complete all as specified and as directed.
91(d)Supply only capacitor 4.0 Mfd suitable for ceiling / exhaust/wall mounting fans complete all as specified and as directed.
92(e)PVC flexible cable twin twisted core of 23/0.0076 size multi stranded copper conductor suitable for connecting ceiling fans / exhaust / wall mounting fans complete all as specified and as directed.
93Rubber bush with MS bolts, nuts & washers with \"U\" clamps for ceiling fans complete all as specified and as directed.
94Supply only motor rotar ring for ceiling fans complete all as specified and as directed.
95Supply only motor stator for ceiling fans complete all as specified and as directed.
96Supply only down rod of 30/45 cm with nut, bolts and safety pin for ceiling fans complete all as specified and as directed.
97Supply only plastic cup with screw for ceiling fans complete all as specified and as directed.
98S&F in repair of exhaust fansmotor upto 300/230 mm sweep, heavy duty, 1400 RPM,AC single phase 230/240 Vwith blades complete all as specified and directed. Make : Bajaj / CG / Havells / Khatian or Equivalent make.
99S&F in repairof exhaust fansouterframe for holding exhaust fan motor upto 280 mm sweep with supporting angle complete all as specified and directed. Make : Bajaj / CG / Havells / Khatian or Equivalent make.
100S&F in repairof exhaust fansouterframe for holding exhaust fan motor upto 300/230 mm sweep with supporting angle complete all as specified and directed. Make : Bajaj / CG / Havells / Khatian or Equivalent make.
101M&L in repair louver of exhaust fan suitable for 300/230 mm sweep complete accessories all as specified and directed
102M&L in repairlouver of exhaust fan suitable for 450 mm sweep complete accessories all as specified and directed
103Dismantling /opening the ceiling fan of 1200 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling/re-fixing in its location complete all as specified and as directed.
104Dismantling /opening the ceiling fan of 1400 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
105Dismantling /opening the wall mounted fan of 300 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
106Taking down exhaust fans 230 mm/300mm / 450mm sweep from position by duly disconnecting electric lines,preparing the surfaces,filling cavities with filler, after cleaning all dust, spray painting with one finishing coat of synthetic enamel paint including writing MES NO and replacing the split pin,rubber pully etc., includingrefixingand connecting the same complete all as specified and as directed.
107Dismantling /opening the exhaust fan of 230 mm/300 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
108M&L extension of down rod for ceiling fanupto 1.5 mtr including nut, bolts , washers complete accessories all as specified and as directed.
109Removing the window type AC/Split type AC of 1.0/1.5/2.0 ton capacity from location servicing the AC, cleaning the condenser and evaporator coil by blower, checking the electrical wiring, repalcement of burnt out wiring terminals, cleaning the air filter, adjusting relays etc., replacement of unserviceable spare parts and fixing back atlocation, testing and commissioning complete allas directed.
110Removing the split type AC of any make from position transporting to a reputed workshop, cutting the suction and discharge line of unserviceable compressor and replace withnew factory made hermatically sealed compressor of same make and type, connecting the suction and discharge line, vacuuming the entire system, arresting all leakages, charging of required quantity of refrigerant, adjusting relays, thermostat etc bringing back and installing in its original position incl testing and commissioning complete all as directedfor the following capacities:-1.5 ton capacity
111All as per item No. 110 above but for2.0 ton capacityNote for item No 62 to 63 :- (i)Gas will be measured and paid separately for item No 62 to 63 under relevent item of this schedule.(ii) Spares cost more than 200 Rs will be measured and paid seperately under relevent item of this schedule.
112Labour only for charging of refrigrent gas (R-22/410A/134A) of required quantity for split/window type AC including leak detection by using nitrogen gas and arresting leakages if any by necessary brazing and flushing the system complete and testing complete for the following capacities:1.5 Ton
113All as per item No. 112 above but for2.0 Ton
114Removing the damaged/unserviceable fan blades from the condenser motor shaft and replace new fan blade of the same size and type for any capacity of window type AC and water coolers all as specified and directd.
115Removing the unserviceable thermostat and Supply and fix new thermostat of same make and type for Split/window type AC 1.5/2 ton capacity. (Make- Indfos/Danfoss)
116Removing the unserviceable condenser unit & supply & fix new condenser unit connecting to the discharge line, brazing, vaccumising & gas charging the unit with required quantity of refrigerant for Split/window type AC of 1.5/2 Ton capacity and testing complete allas directed.
117Removing the unservicable running capacitor of 40 MFD, Supply and fix of new capacitorsuitable for 1.5 ton AC make :- BHEL / EPCOS/ TDK/ TIBCON or equivalent.
118All as per item No. 117 above but forStarting capacitor of 80/100 MFD for 1.5 TR/2 TR AC.
119Removing the unservicable over load protection and Supply and fix new over load protector for split/window type AC of 1.5/2.0 TR capacity.
120Supply and fill refrigrent gas (R-22/410A/134A) for domestic coolingappliance.
121Disconnecting and taking out the unservicable sensor/remote unit completely and supply and fix new sensor unit of indoor unit of AC to suit the AC of Makes carrier / Bluestar / Voltas1.5 Ton Split type AC
122All as per item No. 121 above but for2 Ton Split type AC
123Disconnecting and taking out the unservicable PCB, refixing new PCB for split AC / window AC any type and any make 1.5 Ton, 2 Toncapacity all as directed.1.5 Ton Split type AC
124All as per item No. 123 above but for2 Ton Split type AC
125Disconnecting and taking PCB circuit of disconnecting out PCB from split AC, repairing the same and refixing in original location complete all as specified and directed for 1.5/2 Toncapacity all as directed.
126Disconnect electrical connection, removing copper line, discharge line of split type AC upto 2 Ton capacity including indoor and out door units and all accessories and shifting/ reinstalling and testing the whole unit of split type AC in new location with suitable size and length of copper pipe and making the holes in walls complete all as specified.
127Supply and fix plastic/coir filter suitable for Split/window type AC 1.5/2 Ton capacity including taking down old unsv filter etc complete all as specified and as directed.
128S&F in replacement of brass angle valve for gas charging for split AC 1.5/2 ton of AC compete all as specified and as directed.
129S&F in replacement of swing motor of existing capacity and type for indoor unit of split AC fins complete all as specified and as directed
130S&F in replacement ofMS fabrication clamps for hanging, fan including hook as existing complete all as specified and as directed
131S&F in replacement ofNitrile rubber insulation for suction and dischaged pipe of split type AC of size 15/19 mm dia complete all as specified and as directed.
132S&F in replacement of Soft copper tubbing 15mm dia with nitrile rubber insulation for split type AC complete all as specified and as directed.
133S&F in replacement of Soft copper tubbing 19mm dia with nitrile rubber insulation for split type AC complete all as specified and as directed.
134S&F in replacement of Switch 32 Amps flush type with indication lamp all as specified and asdirected
135S&F in replacement of switch socket combination 2 in 1, 3 pin 5 and 32 Amps flush type universal with indication lamp all as specified and asdirected.
136Supply and fix refrigerators, electric driven (single phase), capacity more than 310 Litres. BEE 5 star rated. Make : LG/Whilpool/IFB.
137Supply and fix voltage stabilizer suitable for Split/window type AC 1.5/2 Ton capacity complete all as specified and as directed. Make : V Guard/Everest/ Sinotech1 KVA
138All as per item No. 137 above but for2/3 KVA
139All as per item No. 137 above but for5 KVA
140Supply and install hi wall split units indoor / outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5 TON completeall as specified and as directed. Make - Blue Star/Voltas/LG.
141S&F ceiling fans complete with complete accessories, 230V, SP 1200 mm Sweep with BEE rating complete with all accessories and fixing the fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm, etc all as specified and as directed Make :- Havells/CG/ Bajaj.
142S&F Exhaust fansAC single phase 230/ 240 V of size 300 mm sweep with louvers fixed outside with all accessories and fixing the exhaust fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm, etc all as directed. Make :Bajaj cat No : 70046, MAXX AIR 300 mm or eqv in Make Havells/CGs/ Orient
143S&F in replacement PVC Fresh air fan of 150 mm sweep 1200/1400 RPM with louver. Make CG/Usha/ Orient/Phillips/Bajaj.
144S&F in replacement of MCB single pole 240 volts 20/25 Amps complete all as specified and as directed

AI Tender Summary

OUR REF NO 45088908
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 34 Lakhs
LAST DATE 03-10-2024
Authority
Authority Name Military Engineer Services
Work Description Repair Replacement Of Internal Wiring Electrical Fittings Fixtures Renewal Of Bldg Earthing Ceiling Fans Exhaust Fans Geysers Spit Window Type Air Conditioners Water Coolers Deep Freezer And Allied Works In Ro Md Otm Accns At Afsod
Basic Detail
Tender No 8201
Bidding Type Tender
Location
City bangalore
State Karnataka
Key Dates
Publish Date 26 Sep 2024
Submission Date 03 Oct 2024
Open Date 10 Oct 2024
Finance
Tender Value 34 Lakhs
Tender Fee 500
EMD 68000
Exemption Available
Document List
6e17e57b-0d01-4cb0-ba63-60fe48396576.html
8201Tender.pdf
BOQ_751611.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 26, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 26, 2024
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 03, 2024
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 03, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 10, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

6e17e57b-0d01-4cb0-ba63-60fe48396576.html

pdf

8201Tender.pdf

xls

BOQ_751611.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender