| 1 | Excavation for StructuresEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. |
| 2 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc.complete |
| 3 | Concrete with cement, coarse sand and 40 mm gauge stone ballast in proportion 1:4:8 in foundations and floors including supply of all material, labour and T&P etc. required for proper completion of the work. as per drawings and technical specifications Clause 802, 803,1202 & 1203 |
| 4 | Brick masonry work in cement mortar in foundation complete excluding pointing and plasteringas per drawing and technical specifications Clauses 600, 1202 & 1203 |
| 5 | Brick masonry work in cement mortar in substructure complete excepting pointing and plastering, as per drawing and technical specification Clauses 602, 603, 604, 1202 & 1204 |
| 6 | Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204 |
| 7 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required. |
| 8 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm overand including priming coat of exterior primer applied @ 0.90litre/10 sqm) |
| 9 | Painting on Steel SurfacesProviding and applying two coats of ready mix paint including primer coat of approved brand on steelsurface after through cleaning of surface to give an even shade as per drawing and TechnicalSpecification Clause 1701 |
| 10 | Providing and Laying of Interlocking Concrete Blcok (M-35) Pavements having thickness 60 mm as per drawing and Technical Specification Clause 1504 |
| 11 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawingsand technical specifications Clause 802, 803, 1202 & 1203 |
| 12 | Providing and laying reinforced cement concrete in superstructure as per drawing andtechnical specifications Clauses 800, 1205.4 and 1205.5 R.C.C grade M 20 |
| 13 | Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete asper drawings and technical specification Clauses 1002, 1005, 1010 & 1202 |
| 14 | Uprooting rank vegetation and weeds by digging the area to a depth of 60cm, removing all weeds and other growth with roots by forking repeatedly,breaking clods, rough dressing, flooding with water, uprooting fresh growthsafter 10 to 15 days and then fine dressing for planting new grass, includingdisposal of all rubbish with all leads and lifts. |
| 15 | Preparation of beds for hedging and shrubbery by excavating 60 cm deepand trenching the excavated base to a further depth of 30 cm, refilling theexcavated earth after breaking clods and mixing with sludge or manure inthe ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: one part of stacked volume of sludge or manure after reduction by 8%),flooding with water, filling with earth if necessary, watering and finally finedressing, leveling etc. including stacking and disposal of materials declaredunserviceable and surplus earth by spreading and leveling as directed,within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure orextra earth to be paid for separately) |
| 16 | Supplying and stacking of good earth at site including royalty and carriageupto 5 km lead complete (earth measured in stacks will be reduced by20% for payment). |
| 17 | Additional lead upto 10 km/cum |
| 18 | Spreading of sludge, dump manure and/or good earth in required thicknessas per direction of officer-in-charge (cost of sludge, dump manure and/ orgood earth to be paid separately). |
| 19 | Supply and spreading of vermi-compost @ 3 K.G/Sqm of lawn area & 3 k.g/sqm of bed area. |
| 20 | Supplying and spreading of sand in Lawn area, including watering, mixing and dressingcomplete. |
| 21 | Anti termite treatment of lawn area through premise 30.50% I P. one literpremise diluted in 499 liters water and applying solution @ 1.00 litre solutionper sqm lawn or bed area.(two application) i/c cost of chemical)and as perdirection of officer-in-charge.and as per direction of officer-in-charge |
| 22 | Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness of existingground prepared with proper level and ramming with required tools wooden and than rollingthe surface with light roller make the surface smoothen and light watering the same andmaintenance for 30 days or more till the grass establish properly, as per direction of theofficer in charge |
| 23 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed withmanure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth afterreduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding withwater, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts(cost of manure, sludge or extra good earth if needed to be paid for separately)Holes 45 cm dia, and 45 cm deep |
| 24 | Bottle palm ht. 150-180 cm bottom girth 20-25 cm well developed in big poly bag size 25 cm |
| 25 | Providing and stacking of Gardenia jasminoides of height 45-60 cm. with 3-4 branches in earthen pots of size 20 cm as per direction of theofficer-in-charge. |
| 26 | Providing and stacking of Excoecaria bicolor of height 45-60 cm. in earthenpots of size 20 cm as per direction of the officer-in-charge. |
| 27 | Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.. |
| 28 | Providing and stacking of Jatropha multifida (red colour) of height 45-60 cm. with 2-3 branches in earthen pots of size 20 cm as per direction of the officer-in-charge. |
| 29 | Providing and stacking of Tabernaemontana coronaria (Chandni single) of height 45-60 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge. |
| 30 | Providing and stacking of Cestrum nocturnum (Raat ki Rani) of height 60- 75 cm. with 4-5 branches in bag of size 25 cm as per direction of the officer-in-charge. |
| 31 | Providing and stacking of Plumeria alba of height 120-135 cm. with 2-3 branches in bags of size 30 cm as per direction of the officer-in-charge. |
| 32 | Providing and stacking of Ficus benjamina (green) of height 150-165 cm., bushy with healthy branches and lush green foliage in big size HDPE bags as per direction of the officer-in-charge. |
| 33 | Providing and stacking of Hamelia patens of height 60-75 cm. with 6-8 branches in poly bags of size 25 cm as per direction of the officer-in-charge. |
| 34 | Providing and stacking of Hibiscus rosasinensis of height 60-75 cm. with 5-6 branches in p.bag of size 25 cm as per direction of the officer-in-charge. |
| 35 | Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unsaverieable material’s as per direction of officer in charge (excluding cost of plant & water) |
| 36 | Cost of plantation per Tree |
| 37 | Cost of plantation per Shrub |
| 38 | Cost of plantation per Hedge/Ground cover. |
| 39 | Extra item for water connection inside the park. |
| 40 | supply and fixing double swing side pipe 30 mm, upper pipe 50mm,seat iron/ rubber belt, chain 6mm with heavy duty bearing |
| 41 | supply and fixing seesaw height 0.5 mts,main frame 35mm N.B Pipe,support 25 mm N.B. Pipe ,seat fibre , capacity 2 children. |
| 42 | CHEST PRESS |
| 43 | PULL CHAIR DOUBLE / SHOULDER EXERCISER |
| 44 | PARALLEL BAR |
| 45 | AERO RIDER /HORSE RIDER |
| 46 | LEG PRESS |
| 47 | TRIPLE TWISTER |
| 48 | Supply & fixing of coloured precast concrete reinforcement bench (chair type) with back rest each set consisting two legs and six slabs joint together with galvanised nuts and bolts of suitable size manufactured by using M-30 grade of concrete with suitable reinforcement (10 mm. in base bars,8 mm in legs and 6 mm in Rings ) drawing , Design and Details attached |
| 49 | Supply,installation,testing & commissioning (SITC) of semi-integrated 15w LED INTEGRETED consisting of pv module 12 V 75W, Solar battery LiFePo4 12.8 V 24 AH,wiring 2 core 2mm,Pole : GI 5mtr long, outer dia 90 mm,thickness 2 mm (height of the pole 5 meters above the ground level,including construction of concrete base of standard size with 5 years warranty along with 5 years AMC |