Tender For Electrical, Bms And Ems System Execution For Cgmp Center Of Cellular Immunotherapies At Actrec.
Tender Overview
Project Description
Electrical, Bms And Ems System Execution For Cgmp Center Of Cellular Immunotherapies At Actrec.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-Sep-2024 | Corrigendum1 | Date | 30-Sep-2024 |
| 2 | 30-Sep-2024 | Date Extension2 | Date | 07-Oct-2024 |
BOQ
| Sl. No. | Item Description |
| 1 | Electrical Work |
| 2 | DG SET |
| 3 | Supply ,Installation,Testing & Commisioning of Diesel Generating(D.G.) set with CLASS G3 governing (40% step load) , alternator of 625 kVA output at 0.8 PF continuous rating with 10% overload capacity for 1 hour in 12 hours, 3 phase, 415 V, 50c/s, radiator cooled,multi-cylinder diesel engine at 1500 rpm , seperately excited AMG having Class H, SPDP alternator (with battery charging generator),with Static AVR +/- 1% & THD<3%, running at 1500 rpm. Both the engine and alternator shall be direct coupled on a common fabricated steel base frame anti vibrating pad mounted with controller suitable for full parallel operation of multiple generators having Engine & generator protection(including REF & RPR)/ parameter display/ operator interface/Power Command 3.3 control system/AMF panel/ Synchronization/Dedicated earthing system/RS 485 Modbus connectivity, etc. The complete set shall be enclosed in composite acoustic enclosure as fully assembled integral unit in silenced accoustic canopy, giving 75 dB at 1 meter,made of 16/14 swg CRCA sheet, complete with first filling of Lube oil/diesel/coolant & fuel hoses, battery, residential silencers,mounted on plinth & obtaining necessary approval from electrical inspector.a) Exhaust piping to be raised upto terace level of nearest building.b) Power/control cabling, terminations, etc.c) 990 ltr. capacity external deisel tank.d). Height of Stack to be maintained as= Height of building + 0.2 * √kVA . e) Factory testing to be carried out in present of ACTREC engineering before despatch of equipments. f) D.G. Sets should comply latest CPCB-IV Norms.g) Required size of foundations. |
| 4 | 625 KVA DG Set with foundation. |
| 5 | AMF Panelsuitable for 625 kVA DIESEL GENERATING SET with battery charger and standard accessories. |
| 6 | MS Class ‘B’ diesel engine exhaust pipe of suitable size (including all fittings, clamps, steel support, required size of foundation) of suitable dia for the engine.The pipe shall be provided with 12 mm thick ceramicfibre rope and below to be insulated with cloth and glass wool. |
| 7 | Supply & Installation of exhaust pipe thermal insulation and cladding. |
| 8 | Installation of Silencer |
| 9 | Supply & Installation of Silencer thermal insulation and cladding |
| 10 | Supply & Installation of M.S. Supports for Exhaust Pipe & Exhaust Structuresuitable for 1 x 200 mm Exhaust Pipe (Structure Height -25 mtrs) Including Standar Panel & Tray |
| 11 | Supply & Installation of S.S. Bellows 200 mm with matching flanges, gaskets andfasteners |
| 12 | UPS |
| 13 | Supply, installation, testing & commissioning of 3 Phase Input, 3 Phase Output with Advance 3 level IGBT-PWM based rectifier & Invertortechnology with built in isolation transformer AC input voltage:415 V +/- 10% , frequency-50 Hz +/- 5%,output voltage-415V +/- 2% , Output frequency-50Hz +/- 0.5%, True Online double conversion Industrial grade, Input phase sequence correction feature,efficiency up to 95%,high short circuit handling up to 3.5 times,Type of battery - SMF, battery capacity as per backup time specified below, battery charging current shall be calculate for unity power factor, Protection- Electronic over voltage trip, electronic under voltage trip, Single phase prevention, overload, Short Circuit and battery overcharge, Indications: AC On, Inverter on Charger fuse, inverter trip. One number RS485 ports to steady the data with all accessories complete etc., |
| 14 | 160KVA online UPS with built in Isolation Transformer 3-PHASE Input and 3-PHASE Ouoput with 30minutes backup having sealed maintenance free batteries of 48Nos. 12V, 200AH capacity, interconnection cables, end terminations, Battery rack with accessories, etc. |
| 15 | L. T.Panels |
| 16 | Free standing, floor mounted MCC panel made out of 2mm thick CRCA sheet duly powder coated after seven tank process consisting of suitable rating Incomer, Aluminum bus bar supported with DMC/ SMC barriers & color coded with heat shrinkable sleeves, metering and outgoing feeders (as mentioned against each panel): |
| 17 | MCC Panel-1 for AHU 1, 2, 3, 4, 5, 6,7,8 AHU for exhaust-2 Nos, MCC 2, UPS, LDB - 1, PDB-1&2 ( as per enclosed SLD). |
| 18 | UPS Panel for ELDB-1 , EPDB-1 ,EPDB-2, EPDB-3,2 Nos.250A FP MCCB with enclosure for UPS Input and Output (AS per enclosed SLD). |
| 19 | LV (Power & Control) Cables |
| 20 | 1.1kV grade XLPE/PVC insulated aluminum/copper multi-strand conductor steel armoured cables. |
| 21 | 3.5C X300mm² AL. Armd. XLPE Insulated cable. |
| 22 | Excavation and Cable layoing and Backfilling as per the ISO Norms |
| 23 | 3.5C X240mm² AL. Armd. XLPE Insulated cable. |
| 24 | 3.5C X185mm² AL. Armd. XLPE Insulated cable. |
| 25 | 3.5C X150mm² AL. Armd. XLPE Insulated cable. |
| 26 | 3.5C X95mm² AL. Armd. XLPE Insulated cable. |
| 27 | 3.5C X 70mm² AL. Armd. XLPE Insulated cable. |
| 28 | 3.5C X 50mm² AL. Armd. XLPE Insulated cable. |
| 29 | 3.5 C X 35mm² Al. Armd. XLPE Insulated cable. |
| 30 | 3.5C X 25mm² AL. Armd. XLPE Insulated cable. |
| 31 | 4 C X 4mm² Cu. Armd. XLPE Insulated cable. |
| 32 | 4 C X 2.5mm² Cu. Armd. XLPE Insulated cable. |
| 33 | 3 C X 10mm² Cu. Armd. XLPE Insulated cable. |
| 34 | 3 C X 6mm² Cu. Armd. XLPE Insulated cable. |
| 35 | 3 C X 4mm² Cu. Armd. XLPE Insulated cable. |
| 36 | 3 C X 2.5mm² Cu. Armd. XLPE Insulated cable. |
| 37 | 1C X35mm² Cu. Unarmd. XLPE Insulated cable. |
| 38 | 1C X70mm² Cu. Unarmd. XLPE Insulated cable. |
| 39 | LV Cable End Terminations |
| 40 | Termination of cables with brass double compression glands including cost of crimping lugs / ferrules, solder, cablesockets, insulation tapes etc. |
| 41 | 3.5C X300mm² AL. Armd. XLPE Insulated cable. |
| 42 | 3.5C X240mm² AL. Armd. XLPE Insulated cable. |
| 43 | 3.5C X150mm² AL. Armd. XLPE Insulated cable. |
| 44 | 3.5C X185mm² AL. Armd. XLPE Insulated cable. |
| 45 | 3.5C X95mm² AL. Armd. XLPE Insulated cable terminations. |
| 46 | 3.5C X 70mm² AL. Armd. XLPE Insulated cable terminations. |
| 47 | 3.5C X 50mm² AL. Armd. XLPE Insulated cable terminations. |
| 48 | 3.5 C X 35mm² Cu. Armd. XLPE Insulated cable terminations. |
| 49 | 3.5C X 25mm² AL. Armd. XLPE Insulated cable terminations. |
| 50 | 4 C X 4mm² Cu. Armd. XLPE Insulated cable terminations. |
| 51 | 4 C X 2.5mm² Cu. Armd. XLPE Insulated cable terminations. |
| 52 | 3 C X 10mm² Cu. Armd. XLPE Insulated cable terminations. |
| 53 | 3 C X 6mm² Cu. Armd. XLPE Insulated cable terminations. |
| 54 | 3 C X 4mm² Cu. Armd. XLPE Insulated cable terminations. |
| 55 | 3 C X 2.5mm² Cu. Armd. XLPE Insulated cable terminations. |
| 56 | 1C X35mm² Cu. Unarmd. XLPE Insulated cable terminations. |
| 57 | 1C X70mm² Cu. Unarmd. XLPE Insulated cable terminations. |
| 58 | EARTHING |
| 59 | Supply, installation, testing & commissioning of earthing station as per IS standard complete with 600x600x6mm GI Plate electrode, salt, charcoal, 2 nos. 50x6 mm Aluminum strip upto test link, 40 mm dia G.I. watering pipe with funnel, and test link. The chamber size shall be fitted with450 x 450 mm with heavy duty C.I. Chamber Cover duly painted and marked with pit identification number both inside and outside as per earthing layout Drawing. |
| 60 | 50X6mm GI strip. |
| 61 | 25X3mm GI strip. |
| 62 | 6mm² single core multi strand wire (Green color). |
| 63 | 10mm² single core multi strand wire (Green color). |
| 64 | Supply, installation testing of earthing station as per IS standard complete with 600x600x3mm Copper Plate electrode, salt, charcoal, 2 nos. 50x6 mm Copper strip upto test link, 40 mm dia G.I. watering pipe with funnel, and test link. The chamber size shall be fitted with450 x 450 mm with heavy duty C.I. chamber Cover duly painted and marked with Pit Identification Number both inside and outside as per Earthing Layout Drawing. |
| 65 | 50X6mm Copper strip. |
| 66 | 25x3mm Copper strip. |
| 67 | Safety Equipments |
| 68 | 2000mmX1000mmX12mm corriguated rubber mats, as per standards. |
| 69 | D.C.P. type fire extinguisher for following capacity cartridge type with gun metal cap 150gram CO2 gas cartridge, powder and brackets confirming to IS 2171-19885 andcompleted erected with necessary clamps made from 50 x 6mm. MS Flat with Nut & Bolts grouted in wallcomplete. 6kg Capacity. |
| 70 | Carbon Dioxide (CO2) Fire Extinguisher user of following capacity with necessary clamps made from 50 x 6mmM.S. Flat with Nut & Bolts grouted in wall complete. 4.5 kg Capacity. |
| 71 | MCB DISTRIBUTION BOARDS :- |
| 72 | 12WAY Three phase power distribution board with vertical double door type (VTPN DB) with 125A TPN MCCB as a incomer & 12 Nos. 32A TPMCB as outgoing circuit. MCB shall be provided with “C” curve. |
| 73 | 8WAY Three phase power distribution board with vertical double door type (VTPN DB) with 125A TPN MCCB as a incomer & 8 Nos. 32A TPMCB as outgoing circuit. MCB shall be provided with “C” curve. |
| 74 | 3 Phase, 8 WAY Lighting distribution board with horizontal double door type40A TPN MCBas a incomer, 32A DP ELCB per phase & 18 Nos. 6-10A SP MCB as a outgoing circuit. MCB shall be provided with “C” curve |
| 75 | 3 Phase , 12 WAY distribution boards with horizontal double door type (ETPN DB) with per phase Isolation kit , 63A TPN MCB as a incomer, 40 A,300mA, DP ELCB per Phase& 30 Nos. 16A/20A/32A SP MCBin outgoing circuit . (10 Nos, MCB per Phase)(PDB). MCB shall be provided with “C” curve |
| 76 | 3 Phase , 8 WAY distribution boards with horizontal double door type (ETPN DB) with per phase Isolation kit , 63A TPN MCB as a incomer, 40 A, 300mA,DP ELCB per Phase& 18 Nos. 16A/20A/32A SP MCBin outgoing circuit .(8 Nos, MCB per Phase)(PDB).MCB shall be provided with “C” curve |
| 77 | Modular & Industrial Type Switch Sockets |
| 78 | Switch Socket Industrial Type |
| 79 | Industrial Pentra type socket & plug with MCB enclosed in enclosure. The scope includes fixing of enclosures ,supply of all fixing accessories/hardware. MCB and socket shall be wired up upto outgoing terminals etc, complete as required. |
| 80 | Single phase 25 Amp 3 pin socket with straight connected plugwith 25 Amp DP MCB. |
| 81 | Single phase 32 Amp 3 pin socket with straight connected plugwith 32 Amp DP MCB. |
| 82 | Three phase 32 Amp 5 pin socket with straight connected plugwith 32 Amp FP MCB. |
| 83 | Supply and Installation of GI Perforated & Ladder Cable Trays :- |
| 84 | Hot dipped galvanized and minimum thickness of hot dip coating is 70 to 100 microns. Thickness of cable tray sheet steel for 50 mm to 300 mm cable tray 2.0mm Thickminimum height of the perforated cable Tray is 30mm or 50mm. Cable tray shall be in different widths and shall be in standard length 2500mm long and suitable to couple two cable trays with coupler. Support required for fixing the cable trays considered in the Structural steel |
| 85 | 50mm(W) X 50 mm(H) X 2mm thinkness perforated cable tray. |
| 86 | 100mm(W) X 50 mm(H) X 2mm thinkness perforated cable tray. |
| 87 | 150mm(W) X 50 mm(H) X 2mm thinkness perforated cable tray. |
| 88 | 300mm(W) X 50 mm(H X 2mm thinkness perforated cable tray. |
| 89 | 450mm(W)X 50 mm(H) X 2mm thinkness perforated cable tray. |
| 90 | 600mm(W) X 50 mm(H) X 2mm thinkness perforated cable tray. |
| 91 | Structural steel for supports. |
| 92 | PVC CONDUITS |
| 93 | PVC conduit with Bends, junction boxes, and all necessary accessories and hard ware as following. |
| 94 | 25 mm PVC Conduit. |
| 95 | 32 mm PVC Conduit. |
| 96 | 50 mm PVC Conduit. |
| 97 | PVC flexible conduit with clamps and all necessary accessories and hard ware as following. |
| 98 | 25 mm flexible Conduit. |
| 99 | 32 mm flexible Conduit. |
| 100 | 50 mm flexible Conduit. |
| 101 | PVC Trunking System |
| 102 | UPVC cable trunking system comprising unplasticised polyvinylchloride rigid material with ignition free. Allnecessary accessories as Coupler,Elbow, Tee, Internal Bend, External Bend, End Cap and, Trunking Divider for 105 x 50mm (depth) Trunking and Hard ware. |
| 103 | Ceiling Fan |
| 104 | 1200mm sweep Ceiling fan |
| 105 | Electrical consultancycharges alongwith provsion of co-ordinated drawings for complete design for electrical and L.V. drawings with monitoring the work and issuance of final completion certificate for the project. |
| 106 | BMS System |
| 107 | Software |
| 108 | BMS Software: Graphical User interface software based on MS Windows with1000 points & 1 client license .The system should be accessible from anywhere on LANor Ethernet . The Communication protocol shall be BACnet Protocols . System should bescalable in all levels , Eggineer and user level passwords. |
| 109 | BMS Client Station:Intel i7 3rd Generation processor 3Ghz, with 1TB X 2nos hard disk, 16 GB RAM/DVD-RW/keyboard/optical mouse/LAN card/32” LED monitor. Minimum 4 USB ports. With pre-loaded licensed Windows 10 Professional software(Latest version),MS office and Anti virus, Dual 2GB Graphic Cards as per tender specification. |
| 110 | Server PC:- The main servers will be Intel Xeon processor E5-2600, minimum speed of 2.3GHz with 6 Core, dual Gigabit Ethernet Port, USB port, Video port. The server memory will be 16 GB DDR4 RAM with 21 inch monitor |
| 111 | Laser Printer for alarms and reports - A4 size (Black & white) |
| 112 | DDC Panels |
| 113 | IP based DDC controllers with in-built real time clock, 32 bit micro-processor CPU,memory, enclosed in MS powder coated enclosureas per IO summary |
| 114 | DDC-1&2 (AHU-1,AEU-1 & AHU-6,AEU-6) with IO Points ofAI - 26, DI - 24, AO - 10 &DO - 08 |
| 115 | DDC-3&4 (AHU-2,3 & AHU-4,5) with IO Points of AI - 22, DI - 14, AO - 08 & DO - 04 |
| 116 | DDC-5 for EMSwith IO Points of AI -62 , DI - 0, AO - 18 & DO - 0 |
| 117 | Gatewaymodule for integrating the third party systems communicating on one of theStandard Open Protocols such as BACNetand MODBUS, etc with BMS |
| 118 | Chiller intigration, Energy meters, Hot Water Generator |
| 119 | Field Instruments |
| 120 | Testing and Commissioning of following Instruments with required accessories |
| 121 | DP switch across fan to monitor Filter clog status monitoring (Fine Filter)Range: Max 1000 Pa |
| 122 | Differential Pressure Switch for AHU Run Status range: Max 500 Pa |
| 123 | Duct DP Transmitter across fan |
| 124 | Room Temp, RH & DP Display unit with inbuilt DP and External Temp & RH Transmitter |
| 125 | Static pressure senosr for VFD speed |
| 126 | Duct Mount Temperature & Rh sensor with Temp Accuracy: ±2% & RH Accuracy: ±3% |
| 127 | Damper Actuators |
| 128 | Room Temperature & Rh |
| 129 | Control cables, Cable trays and Conduits with accessories. |
| 130 | 6C X 1 Sq mm armoured Copper Shielded Cable |
| 131 | 4C X 1 Sq mm armoured Copper Shielded Cable |
| 132 | 2C X 1 Sq mm armoured Copper Shielded Cable |
| 133 | Shielded CAT 6 Cable, 4 pair, UTP,24 AWG Cable |
| 134 | GI Perforated Cable Tray 50 X 50 X 2 mm with required MS supports |
| 135 | GI Perforated Cable Tray 100 X 50 X 2 mm with required MS supports |
| 136 | GI Perforated Cable Tray 300 X 50 X 2 mm with required MS supports |
| 137 | 25 mm PVC Conduit with its mounting accessories |
| 138 | 8 port network switch with Rack |
| 139 | Validation & Documentation |
| 140 | Validation of the BMS system with related qualification documents DQ/IQ/OQ/PQ as perinternational norms and client standards. |
| 141 | E.M.S. System |
| 142 | STANDALONE CONTROLLER |
| 143 | Operator PC:- PC with thefollowingminimumspecifications:INTELCOREi7,3GHz,4GBRAM,500GB HDD,32\" LCDmonitor,USBMouse,USBkeyboard,DVD/CDwriter,modem/IP connectivity,HDMIoutput, configurationwithWindows10 pro, Office 12 and antivirus(Work station ,operator station ,one stand by as per spec) |
| 144 | EMS Software |
| 145 | Converter for Intigration to EMS systeam |
| 146 | 16 port Ethernet switch with Rack |
| 147 | 8 port Ethernet switch with Rack |
| 148 | SMPS |
| 149 | Field Instruments |
| 150 | Room DP Transmitter with three row Display unit(T&Rh and DP) |
| 151 | Room Temperature & Rh Transmitter |
| 152 | Control cables, Cable trays and Conduits with accessories. |
| 153 | 6C X 1 Sq mm armoured Copper Shielded Cable |
| 154 | 3C X 1.5 Sq mm armoured Copper Cable |
| 155 | Shielded CAT 6 Cable, 4 pair, UTP,24 AWG Cable |
| 156 | GI Perforated Cable Tray 50 X 50 X 2 mm with required MS supports |
| 157 | GI Perforated Cable Tray 100 X 50 X 2 mm with required MS supports |
| 158 | GI Perforated Cable Tray 300 X 50 X 2 mm with required MS supports |
| 159 | 25 mm PVC Conduit with its mounting accessories |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender