}

Tender For Maintenance And Repair Of Street Lights Security Lights And Solar Lights And Its Connected Items Including Repair To Lt Distribution Network At Mh And Range Hills Area Under Ge Mh And Rh Khadki, Pune-Maharashtra

Military Engineer Services has published Tender For Maintenance And Repair Of Street Lights Security Lights And Solar Lights And Its Connected Items Including Repair To Lt Distribution Network At Mh And Range Hills Area Under Ge Mh And Rh Khadki. Submission Date for this Tender is 02-10-2024. Rough Finishing Tools Tenders in Pune Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

45068359
Corrigendum : Tender For Maintenance And Repair Of Street Lights Security Lights And Solar Lights And Its Connected Items Including Repair To Lt Distribution Network At Mh And Range Hills Area Under Ge Mh And Rh Khadki
Open Tender
Indian
Maharashtra
Pune
02-10-2024

Tender Details

Tender For maintenance And Repair Of Street Lights Security Lights And Solar Lights And Its Connected Items Including Repair To Lt Distribution Network At Mh And Range Hills Area Under Ge Mh And Rh Khadki-Taking down old unserviceable rusted damagedstreet light pole 9 mtr/ 11 mtrslong of any type complete from site . 2 Supply and errect in vertical position Steel tubular swaged poles,type 410 SP- 31 (09 mtr long) in replacement with 300mm x 300mmx6mm mild steel plate continiusly welded to pole, final taper plug, bolts,nuts and screws and making holes as per requirementall as specified including factory painted with two coats ofblack bituminous paint internally through out and externally for embeded portion and applying one coat fo red oxide primer, making 05 Nos strip each 30 cmhigh with super enamel paint ( Black and yellow) from ground level / coping upto 1.5 m, painting with two coats of aluminium paint for the remaning height complete all as specified and directed.Note :- PCC in foundation, copping, excavation and earth work shall be measured and paid separately under relevent items of sch. 3 Supply and Erect in true vertical position , LT electric pole, Octogonal pole , hot deep galvanised in replacement with base plate of 220x220x12mm thick , 07 mtrs long , top dia 70mm , bottom dia 135 mm thickness of sheet - 3mm, includingsingle arm GI bracket , inbuilt cable junction box with door , connection plate, MCB 6 A, duly connecting existing LT UG cable, cable lugs , work included necessary earth work and RCC foundation as per manufacturersrecommendation complete all as specified and as directed.Make: Bajaj / Crompton Note: Earth work, PCC foundation, foundation bolts as per manufacturer recommendation included in the unit rate. 4 Taking down old unsv Flood lightfitting of any type/capacity from its location complete . 5 Dismantling and Taking down old unsv street light fitting of capacityupto 120 watts from itslocation complete . 6 Supply and Fix in replacement LED Floodlight fitting of capacity 120 wattsmade up of pressure die cast aluminium housing with toughned glass and high power LEDs and secondary lenses, having system efficacy greated than 110 lumen per watts with surge protection device included. The luminaries shall be totally enclosed dust and water proof with minimum IP -66 protection pre wired up to connector including 2.5 sq mm PVC insulated cable for making connection (upto 9 mtr length), complete all as specified and directed by Engr-in-charge.Make :- Halonix/Crompton/Benlo. 7 All as per item No 6 but of capacity 150 watts 8 All as per item No 6 but of capacity 200 watts 9 Supply andFix in replacement LED Street light fitting of 90/100 Watt (Cool White) including LED lens complete with body robust, corrosion resistant, superior finish, made up of high pressure die cast aluminium alloy housing. The luminaries shall be totally enclosed, dust and water proof with minimum IP - 66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 300 V, AC, frequency 50 - 60 Hz, P.F should be more than 0.95 with Total Harmonic Distoration THD(I) less than 10% , cool white colour and lamp starting time should not be more than 10 second fitting should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection,no load , open circuit and short circuit protection . The efficiency of LED luminaries system shall be more than 100 lumens per watt and must be certified by the LM-79 test report and including provision of connection for street light from pole box with 2.5 Sqmm PVC insulated stranded copper conductor FRLSH cable (upto the lenght og 9 mtr) complete all as specifiedand directed by Engineer-in- charge.Make :- CROMPTON / HALONIX /BENLO 10 All as per item No 7 above but of 60 Watt Make :- CROMPTON / HALONIX /BENLO 11 All as per item No 7 above but of 45 WattMake :- CROMPTON / HALONIX /BENLO 12 Supply and Fix in replacement Inverter LED Street light fitting of 90 Watt including LED lens complete with body robust,corrosion resistant,superior finish and without any cracks or through holes,made in a single piece by high pressure die cast aluminium alloy having inbuilt battery back-up for upto 2 hrs with auto ON/OFF.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest ammendments and input voltage range 140 - 300 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.95 with Total Harmonic Distoration THD(I) less than 10% ,cool white colour and lamp starting time should not be more than 10 second fitting should be provided with 10 KV surge protection. Driver should also have double phase protection,no load , open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from -10 degree Centrigrade to 60 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 66 degree protection. The efficiency of LED luminaries system shall be more than 100 lumens per watt and must be certified by the LM-79 test reportcomplete all as specifiedand directed by Engineer-in- charge.Make :- HALONIX /BENLO/CROMPTON/JAQUAR 13 S&F in repairsBracket for fixing of street light fittings bend to shape, made out of40 mm dia GI pipe medium grade upto 1.5 mtr long fixed withtwo sets of MS clamps made out of flat iron of size 50x6 mm fabricated to shape and fixed with nuts bolts and washers& two coats of aluminiumpaints over a coat of red oxide primer complete all as specified and directed by Engr-in-ChargeNote : MS clamps, nuts, bolt and washer shall be measured seperately under relevant item 14 Taking down old unsv LTUG cable of size up to70 sq mm from trenches / poles / ducts etc. 15 Supplying, laying, jointing, commissioning and testing XLPEinsulated screened PVC bedded, armoured,heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade confirming to IS-7098 (Part-I-1988) laid in trenches/ducts/wall / floor / pipes/ poles including cable glands and aluminium lugsof appropriate size, PVC sleeve etccomplete all as directed by Engr in -Charge for following sizes . Make :- Havells / Gloster / Finolex / Polycab 16 50 sq mm 3.5 core . 17 35 sq mm 3.5 core 18 25 sq mm 3.5 core 19 16 sq mm 4 core. 20 10 sq mm 2 core 21 6sq mm 2 core 22 NOTE :- Earth work , bricks , riddled earth , GI pipe for protection of cable will be measured & paid under under relevant items of schdule . 23 M&L earthing complete with galvanisedsteel earth plate eletrode 600 x 600 x 6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5m below normal ground level, connected to the earth lead wire 4.0 mm dia (GI wire) size, by means of bolts, nuts, check buts and washers ofgalvanised iron, earth lead wire 4.0 mm dia protected by provision of GI medium grade pipe 15 mm bore including provision of aggregates with 40 mm thick cover of RCC (1:2:4) , re-inforced with XPM (weight not less than 4 kg per sqmm) and frame of angle iron 40x40x3 mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edged of earth plate, common salt and charcoal filling,funnel, wire mesh and earth work in hard/dense soil, returning filling in distance not exe 50 mtr and removal of surplas soil to plate No 3 of SSR 2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion complete all as specified and directed. 24 M & L earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx6 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to 32x6 mm GI stripas earthling lead by means blots and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel, wire gauge.CI cover with frame , 50 MM dia GI pipe light grade for protection of wire/strip etc including necessary excavation in any type of strata , returning, fillingremoval of soil outside MD land ,filling ofcharcoal andsalt complete all as shown in electrical plate No. 3 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion. 25 S & F three core PVC insulated and FR PVC round sheathed, copper conductor 1100 volts grade cable of size 1.5 sqmm (multi stranded) complete all specified and directed by Engr-in-charge. 26 S & F in replacement LED bollard light, with aluminium housing with acrylic diffuser of cap 10/15 W inverted pyramid tripod type LED bollard with soft 360 degree light distribution with IP 65/66 protection, bollard length should be 800mm complete with all accessories and as specified.Make :- Crompton cat no LBLSN-10-CDL or equivalent in Halonex/ Wipro/Surya. Note :- The quoted rates is inclusive of excavation and foundation work of Pcc of bollard fittings as recommended by OEM and Engr- In- Charge. 27 S & F in replacement of LED post top lantern 40W aluminium housing, with IP 65/66 protection, clear acrylic diffuser, die cast aluminium spigot , spun aluminium powder coated top cover complete with accessoireswith suitablesize40/50/60 mm outer dia GI pipe and plastering work wherever reqd all as specified and directed.Make :- Halonix cat no HLPT-04-40-CW or equivalent in Crompton/ Wipro/Surya. 28 Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation of poles stays laying of electric cables, pipes etc and getting out in soft/loose soil complete all as specified and directed. 29 All as per item No 17 but in hard/dense soil. 30 Removing excavated material soil to a distance not exceeding 50m and depositing where directed at a level not exceeding1.5m above the starting point complete all as specified and directed 31 Returning, filling in,including spreading, levelling watering and well ramming in layers not exceeding25cm in soft/loose soil complete all as specified and directed. 32 M & L for riddled earth forcushioning to under ground electric cable including spreading , levelling and hand punning complete all as directed.Note - Punned thickness shall only be measured & paid . 33 M& L for road cuttung / foot path and making good with PCC 1:3:6 TYPE C-2 ( using 40 mm graded stone aggregate ) of 150 mm 34 Supply and laying un-reinforced precast concrete cable cover LV, Type I, flat, size 250mm x 150mm x 40mmfor Under ground cable all as specified and directed. 35 Supply and laying GI tubes light grade, galvanized, 40 mm borein repair ,laid in trenches or under floor or fixed with poles/walls for protection of electric cable all as directed 36 All as per item No 24 but 80 mmm bore. 37 Plain cement concrete (PCC) type C21:3:6 using 40mm graded aggregate stone for making foundation of Pole/stay assembly 38 Plaincement concrete (PCC) type C11:3:6 using 20mm graded aggregate stone for making copings of Poles etc. 39 S&FJunction box of size not less then 325x220x150mm, made of high quality thermo plastic polystyrene, weather proof, dust, jet water proof, chemical, acid corrosion, impact, insulated & shock proof IP 66 / 67 for outdoor Installation with internallly embedded gasket (PUR) including the box fitted with connector 8 way 40 Amps 01 No including Emlex stud type TB 4 Nos incoming / outcoming cable at controlled with MCB SP 6 Amps 01 No & enclosed along pole including fixing with steel tubular poles with two Nos FI clamps 25mmx3mm withnuts, bolts and washers complete and making connection with 1.5 sqmm copper conductor unsheathed FRLS PVC insulated 3 core from junction box to security lights fittings duly laid inside the streel tubular pole and bracket. complete all as specified and directed by Engineer-in-Charge.Note : (40 mm bore GI pipe light grade, 3 core 1.5 sqmm cable and GI brackets will be measured separately . Make :- Sintex Cat Part No. GSJB-3726 or equivalent in Indokop / HenselNote :- Cost of flat iron clamp is deemed to include in unit rate of this items. 40 M& L for detection of street lightLT UG cable fault with the help of cable faultdetecting machine with experinced engineer andhelper including necessary earth work complete & jointing the fautly cable with new joint , testing etc complete all as directed .Note :- Cable joint kit will be measured and paid separately under relevent item of schedule . 41 Supply only straight through joint kit , heat shrinkable type suitable for LT UG electric cable 1100 volts grade of sizeup to 16 sq mm 2 core cable complete all as directed . 42 Supply only straight through joint kit , heat shrinkable type suitable for LT UG electric cable 1100 volts gradeof size from 25up to 50 sq mm3.5/4 core cable complete all as directed . 43 Supply and fix in repair brass terminal 4 way, 63/100 Amps capacitywithbakelite insulator fixed in street lightjunction box complete all as directed . 44 M& L for repairing of street light fitting / luminaries of any capacity / type with replacement of burnt control wiring, LED drivers 45/60/90 watt etc complete all as directed . Note - (i)Cost of replacement of driver will bemeasured and paid separately under relevant item of schedule .(ii)Quoted rates is inclusive of T&P required for doing the complete job from any height. 45 Supply only LED Drivers of street light fitting suitable for 45/60 watt capacity street light fitting complete all as directed . 46 Supply only LED Drivers of street light fitting suitable for 90 /100/120 watt capacity street light fitting complete all as directed . 47 M & Lfor surface preparing by old paintremoving by scrubbing with embry paper / wire brush and painting tosteel tubular pole 9/11 metre long (any type)with two coats of epoxy based paint aluminium grade paint over a coat of one coat of red oxide primer and painting up to 1.5 M above PCC coping in black and white strips 5 Nos each 30 cm high starting from bottom of pole including writing of pole number with black enemelled paint of 25 mm high letters in 10 cm dia circle in white paint completeall as specified and directed. 48 Supply and fix in repair Astro time switch with more than 100 hrs battery back up working on 240 volts , 50 Hz AC supply as per cat No AUTS02AST00 of L&T make or equivalent make of Indoasian/Havells . 49 Supply and fix in repair 4 pole power contactor of capacity63 Amps , 415 volts AC for street light timer panel 50 Supply and fix in repair MCB 4 poleof capacity40 Amps C curve , 415 volts including necessary disconnection of incoming and outgoing cable complete all as specified and directed. 51 Supply and fix in repair MCB SP of capacity6-32 Amps C curve , 240 volts including necessary disconnection of incoming and outgoing cable complete all as specified and directed. 52 M& L for triming of tree branches with in 2.0 mtr on either side of the electric line/Steet light poles and timmer panels and E/M installation with suitable T & P and desposing the waste as directed . 53 Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint 54 Supply and fix in repair solar LED street light 30 wattluminaire integarted made of corrsion aluminium as heatsink and MS powder coated housing IP-65 with PV roatation & tilting features ,inbuilt constant current driver , autonmatic dusk to down charge controlwith PIR motion sensor ,6500k temp , with integrated mounting bracket with 12.8v 30 AH litium ferro phosphate (Li-FePo4) rechargeable BIS certified cells .Make Halonix cat ref : HLSSLPVR0901081120-30W-WOP-CWL or equivalent make crompton/ havells.Note:Pole for mounting solar street light is included in the quoted rates. 55 M & L for checking the solar light , charging of batteries, cleaning the surface of the solar panel, terminals etc and maintainingthe serviceability throughout the period of contract all as specified and as directed 56 Supply and replace DC Charging with control unit for solar street light panel all as specified and as directed. 57 Supply and replace batteries of solar street light of cap 54/60 AH , 12/12.8 volts high effiency for solar street light 20/30 Watts all as specified and as directed. 58 Supply and fix rigid PVC line separator suitable for 2 wire made out from high grade PVC material, having distance between phase to phase 300 mm suitable for 1100 volts grade . 59 Taking down unserviceable street lightpanel and Supply, install, commissioning and testing of street light panel outdoor type 415 V/440 Volts of size not less then 0.6x0.6x.03 , confirming to IEC 61439 with IP-54 protection of suitable size made out of 3.15 mm thick CRCA sheet with locking arrangement and complete panel should be powder coated with having neoprene rubber gasket for sealing door,doors of the panel should be removable type,3 phindicators lamp etc with provision for 02Nos of 2 Pole 32 Amp MCB out going, 01 No IncomingTPN 63Ampwith Analog street light timer cat No AUTS02AST00 of L&T, copper panel control wiring as per IS direction,make internal compartment for mounting MCBs , the panel shall be mounting on 50 x 50 x 6 mm MS angle iron and 60 cm above the normal ground level & embedded 20 cm below ground level in PCC foundation (1:2:4) type B 1, connect new UG cable for Incoming from LT panel cable shall enter through cable glands for safety of cable where enter through panel complete all as specified and directed by Engr-in-charge. Note: Panel should be CPRI certified.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 25-09-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 02-10-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail