Tender For Repair / Maintenance Of Electric Meter, Smart Meter And Building Connecting Cables Other Allied Works Under Age (I) Af Manauri
Tender Overview
Project Description
Tender For Repair / maintenance Of Electric Meter, Smart Meter And Building Connecting Cables Other Allied Works Under Age (I) Af Manauri
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-Sep-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 01-Oct-2024 |
BOQ
| Sl. No. | Item Description |
| 1 | Transaction charges/Token generation charges are to be paid per meter for annually ( for 01 year) complete all as specifies and directed.Note :The unit rate quoted includes for charges for annually per meter. |
| 2 | Material and labour for sub main wiring with two runs of single core PVC FRLS IS-694 cable with unsheathed multi-stranded copper conductor of size 06 Sqmm and drawing through in concelead rigid non metallic PVC conduit pipe medium grade heavy duty in suitable size with all necessary fittings including one run of FRLS insulated unsheathed stranded copper conductor cable of size 06 Sqmm as earth wire (green in colour) and connected to common earth dolly complete including taking down of old unserviceable sub main wiring including taking out to old unsv sub main wiring with accessories complete all as specified and as directed. Note : (i) Two run of 06 sqmmwith one run of PVC conduit pipe shall be measured agaist one unit. (ii)Cost of cutting /chasing/ plastering /colouring etc as site shall be included matching to disturbed surface all as existed. |
| 3 | All as above item 2.00 above but three run of 2 Core 4 Sqmm for phase ,neutral and earth wire with suitable size concealed PVC conduit pipe complete all as specifies and directed. |
| 4 | S&F sheet metal enclosure for MCB distribution board SPN, double door, 8 way with 200 Amp rated bus bar 230 Volts including taking down to old unsv DBs in any make/ model/ way etc with accessoriescomplete all as specifies and directed. |
| 5 | Supply to be replacement of existed unsv at given site LED bulb 12 W complete all as specifies and directed. |
| 6 | Supply and fixing10 WLED bulk head light fittings incl making all electric connection using three core copper cable drawn through in PVC flexible counduit pipe from ceiling rose to fittings complete all as specifies and directed. |
| 7 | S&Fin replacement switch piano, flush type, single pole, one way 5 Amps complete all as specifies and directed. |
| 8 | S&F in replacement switch piano, flush type, single pole, one way 15 Amps complete all as specifies and directed. |
| 9 | S&Fin replacementsocket 5 Amps flush type. |
| 10 | S&Fin replacementsocket, 5 pin16 Amps flush type. |
| 11 | S&FLED recessed mounted 2x2 luminaire LED 36 Wlight fitting with minimum 100lumen per wattenergy saving low glare high power mounting on twoNos PVC round/ square block on surface of wall / beam etc incl making all electric connection using three core copper cable drawn through in PVC flexible counduit pipe from ceiling rose to fittings including taking out to unsv old fittings complete all as specifies and directed. |
| 12 | Taking out& rectifying, Jumping/Fast & Slow Running complaint meter and fixing master meter monitering reading of 5 days and refixing of serviceable meter as per the different location complete all as specified and directed. Note : (i) Master meter will be provided by the contractor including all electrical connections (ii) 5 days readings shall besubmitted by the contractor to Engineer - In - Charge . |
| 13 | S&Fin replacement 25 W bldg security light LED fitting Warm/day cool as required, IP 65 IK 07Aluminium Pressure Die Casting protection with high powerLED completewith including provn of flexible three core cablefrom ceiling rose to fitting terminal for making electrical connection, fixing the fitting on wall including all necessary fixing accessories with nuts, boltand all Earth work completecomplete all as specified and as directed .MAKE: HAVELLS/BAJAJ/PHILIPS. |
| 14 | S&Fin replacement 45 W bldg security light LED fitting Warm/day cool as required, IP 65 IK 07Aluminium Pressure Die Casting protection with high powerLED completewith including provn of flexible three core cablefrom ceiling rose to fitting terminal for making electrical connection, fixing the fitting on wall including all necessary fixing accessories with nuts, boltand all Earth work completecomplete all as specified and as directed .MAKE: HAVELLS/BAJAJ/PHILIPS. |
| 15 | Supply in replacement to Driver cercuit plate of LED security light fitting capacity 45 to 60 Watt in origional suitable for Make/ model suggested by Deppt complete all as specified and directed. |
| 16 | S&Ftemper proof energy meter in basic current rating 5 to 30 Ampsand maxium400 % , 220 volts single phase two wireconforming to STC with making all electric connection and mounting on teak wood board in suitable sizecomplete all as directed. Note :Old meter shall be deposited by contractor in MES Yard. |
| 17 | S&Ftemper proof energy meter in basic current rating 10to 60 Ampsand maxium400 % , 220 volts Three phase two wire conforming to STC with making all electric connection and mounting on teak wood board in suitable sizecomplete all as directed. Note :Old meter shall be deposited by contractor in MES Yard. |
| 18 | S&Fhigh bay down light LED 80 Watt high efficency with hanging accessories with beam/ struss etc as site and making all connection using three core copper flexible cable drawn through in PVC flexible conduit pipe from ceiling rose to light fittings complete all as specified and directed. |
| 19 | S&Fin replacementextension rod for ceiling fan made out by light grade galvanised water tube15 MM dia of bore in required length up to 1.5 Mtrs longincl cutting /making hole etcas site required complete and directed. Make : Tata/ Jindal / Swastic |
| 20 | S&Fmodular switch , one way 6 Amps 1 module |
| 21 | S&F modular switch, one way 16 Amps 1 module |
| 22 | S&F modular bell push6 Amps 1 module |
| 23 | S&Fmodular socket 6 A, 2/3 pin combined 2 module |
| 24 | S&F modular socket 16 A, 3/5 pin combined 2 module |
| 25 | S&Fin replacement bell ding dong type AC 230 volts single pole |
| 26 | S&Fceiling rose surface type 65 MM x 50 MM, 2 to 3 terminal. |
| 27 | S&F in replacement modular fan regulator step type 120W 2 module |
| 28 | S&Fin replacement white cover plate with frame 2 module |
| 29 | S&Fin replacement white cover plate with frame 3 module |
| 30 | S&Fin replacementwhite cover plate with frame 4module |
| 31 | S&Fin replacement white cover plate with frame 6 module |
| 32 | S&Fin replacement white cover plate with frame 8 module. |
| 33 | S&Fin replacement Led spiketrack light 5w with lumen output 560 lumen , length 130mm, THD <10%,CRI >80 and colour as per engineer in charge complete all as specified and directed. |
| 34 | S&F toMCCB , 415 volt TPN 4 poles 63 Amps ,16 KA breaking capacity, thermal based adjestable type |
| 35 | S&FMCB , SPN, 2 pole 220 volts , 63 Amps , \"C\" Curve 10 KA. |
| 36 | S&FMCB , SPN, 2 pole 220 volts , 40 Amps , \"C\" Curve 10 KA. |
| 37 | S&FMCB , single pole215 volts , 10-32 Amps , \"C\" Curve 10 KA. |
| 38 | S&Fmodular type power unit single phase 220 volts 32 Amps socket and control switch ISI marked 4 module complete all as specified and directed. |
| 39 | Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ.(ii) Make of material shall be as per mentioned in Particular specifications or Appendix \"B\" to Particular specifications as approved by AGE (I) AF manauri |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender