| 1 | Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes,etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed. |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and directed. |
| 3 | Excavating post holes or similar holes, each not exceeding 0.5 Cum, getting out in Soft/ Loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50m & making good surface complete all as specified and directed. |
| 4 | Removing Excavated soils not exc. 50mand depositing where directed at a level not exc 1.5 M above the starting pointcomplete all as specified and directed. |
| 5 | S & F Mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 6 | Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and directed. |
| 7 | M & L for brick work with sub class ‘B’ old size bricks straight or curved on plan n.exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 8 | All as per Sl item No. 7.00 above but except brick.Note:-Serviceable quantity of bricks obtained from demolition shall be reused under this item |
| 9 | Dismantling bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc. (each layer) Laid, bedded and pointed in any mortar complete all as specified and directed. |
| 10 | M&L Bricks sub class B, laid flat in floors old size brick bedded and jointed in cement mortar 1:6 and pointed in cement mortar 1:3 complete all as specified and directed. |
| 11 | All as per Sl item No. 10.00 above but except brick.Note:-Serviceable quantity of bricks obtained from demolition shall be reused under this item |
| 12 | M&L Bricks, sub class B, laid on edge, in drain old size brick bedded and jointed in cement mortar 1:6 and pointed in cement mortar 1:3 complete all as specified and directed. |
| 13 | All as per Sl item No. 12.00 above but except brick.Note:-Serviceable quantity of bricks obtained from demolition shall be reused under this item |
| 14 | M&L75 mm thick, PCC 1:4:8, type D-2(using 40 mm graded crushed stone aggregate) as in sub floor, sub base of floor, etc complete all as specified and directed. |
| 15 | M&L 75 mm thick, PCC 1:3:6, type C-2,(using 40 mm graded crushed stone aggregate) as inplinth protection, hardstanding, floors, paths, etc, finished even and smooth without using extra cement complete all as specified and directed. |
| 16 | M&L cement concrete 1:2:4 type B-0 (using 12.50 mm graded crushed stone aggregate) as in coping of poles,wall, top of drain and similar work etc and including necessary formwork complete all as specified and directed. |
| 17 | M&L PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concreteetc complete all as specified and directed. |
| 18 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 19 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed. |
| 20 | Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided including padding concrete on roof complete all as specified and directed. |
| 21 | M&L Factory made precast cement concrete M25 (using 20 mm graded stone aggregate) road kerbs (450 x 300 x 100 mm or 300 x 300 x 100 mm) one edge slightly rounded or chamfered angles and setting in cement mortor 1:4 including necessary formwork or moulds complete all as specified and directed. |
| 22 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 23 | S & F Mild steel work in framed work such as grills, gratings, framed guard bars, ladders etc., with ends of bars shouldered and/ or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 24 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed. |
| 25 | M&L for preparing newly plastered walls surfaces and applying two coats of cement base paint complete all as specified and directed. |
| 26 | M&L preparation of new steel surfaces of any description not exceeding 10 cm width or girth when unconnected with other painting or when painted in a different tint and including applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 27 | M&L preparation of new steel surfaces of any description, not otherwise described over 10 cm width or girth and including applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 28 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 29 | M&L for Reinforced Cement Concrete Type B-1 1:2:4 Nominal mix (using 20 mm gradedstone aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, deck slabs and in shelves and the like complete all as specified and directed. |
| 30 | M&L for Precast Reinforced cement concrete 1:2:4, type B1 (Using 20 mm gradedstone aggregate) in landings, cover slabs (for Manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:6 complete all as specified and directed.Note :- Reinforcement shall be measured and paid separately |
| 31 | M&L for Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed. |
| 32 | M&L for Mild TMT bars6 mm to 8 mm dia., cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips as in stirrups complete all as specified and directed. |
| 33 | M&L mild steel round bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends for securing chain link fencing, conforming to IS Fe 410-W(Gde.E-250), quality-A, complete all as specified and directed. |
| 34 | S & F of mild steel screw bolts (machine made) with hexagonal or square head at one end and screwed the other or screwed both ends, each screwed ends to be fitted with washer and one hexagonal or square nut, exc. 10 cm but n.exc. 15 cm long and 11 to 15 mm dia of shank complete all as specified and directed. |
| 35 | Supply only chain link fencing for fixing to fencing post with nut and bolt and flat iron complete all as specified and directed. |
| 36 | Fixing only in repairs chain link fencing including line wires, any mesh, size and type of standards, rails, straining bolts, etc, and including provision of binding wire complete all as specified and directed. |
| 37 | S&F galvanised. 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc,(each line wire to be measured) and including dismantling the barbed wire complete all as as specified and directed |
| 38 | Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) internal dia set in cement mortar complete all as specified nad directed. |
| 39 | S&F 450 mm bore Reinforced concrete pipes, class NP2, laid in trenches andjointed with collars in cement and sand mortar 1:1 complete all as specified and directed.(Note :- Excavation & earth work shall be measured separately ). |
| 40 | M & L for PCC 1:4:8 type D2 (using 40 mm gradedstone aggregate) in concrete bed to drain pipes including packing under and completely surrounding the pipes after they are laid and tested for pipes of 450 mm bore pipe complete all as specified and directed. |
| 41 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed. |
| 42 | M&L cement concrete chequered tiles 300x 300 x 25 mm thick with grey cement with pigment, set and jointed in neat cement slurry and pointed in coloured cement to match the surfaces as in floors laid over and including 15 mm thickscreed bed in CM 1:4 complete all as specified and directed. |
| 43 | M&L 8 ot 10 mm thick digital ceramic heavy duty parking tiles (square / rectangular) polished, area of each tiles exc.0.08 sqm butn. exc.0.16 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15 mm thick screed bed in CM 1:4 finish even and rough complete all as specified and directed. |
| 44 | M&L 60 mm thick machine pressed precast concrete interlockingcoloured paver block of any shape and size confirming to IS 15658-2006, M-35 grade, set with grey cement and pigment, laid over and including 20 mm thick screed bed CM 1:6 including sand cushioning complete all as specified and directed. |
| 45 | Dismantling post or struts (wood, steel or RCC) any section, including taking out embedded portion in concrete / natural ground masonary etc and making good the disturbed ground complete all as specified and directed. |
| 46 | S & F in repair concertina coil razor blade type, fixed with galvanised \"J\" clips, of following specification :-(a) Dia of coil spiral / loop - 600 mm(b) No of spirals / loops per bundle of coil - 50(c ) Weight of each bundle of coil - 8 kg (miniumum)(d) Coverage of wall / fence per bundle of coil - 6 mtr(e) Central core wire made from high tensile spring steel wire (conforming to IS:4454) of dia 2.50 mm, UTS 1600 N/Sqmm (minimum), duly hot dipped galvanised (conforming to IS-2629) zinc coating 230gm/sqm (minimum)(f) Razorblade : Electro galvanized steel razor blades of length 11.50mm, width 19mm & thickness 0.50 mm, conforming to IS-1573, zinc coating 120gm/sqm, pitch of barbs 25.00mm(g) Handle, clips (minimum 5 clips per 2 spiral) and spikes to be provided as required complete. |