| 1 | Trial bore of 200 mm dia upto 200 m depth below ground level in any kind of soil strata including hard stone /boulder complete all as specified and directed. |
| 2 | M&L for Development of tube well with compressed air and after with 25% extra capacity pump by pumping muddy water |
| 3 | M&L of Yield test for the bore well by continuously pumping for 8 Hrs to determine safe pumping yield complete all as specified and directed. |
| 4 | Supply and packing pea gravel graded round shape and screened complete all as specified and directed. |
| 5 | Supply and lowering of PVC casing pipe of size 6\" (150mm) nominal diameter conforming to IS 12818:1992, ISI marked with all connected fittings required for lowering the pipe complete all as specified and directed. |
| 6 | All as per above but PVC casing filter pipe of size 6\" (150 mm) nominal diameter complete all as specified and directed. |
| 7 | Supply and lowering of uPVC column pipe with socket, size 2\" (50mm) standard grade with minimum hydrostatic pressure 15 kg/cm2 complete all as specified and directed. |
| 8 | Supply lowering and testing of submersible pumpset with minimum discharge capacity 20 Litres per minute at total head 101 metres, with 2 HP motor complete all as specified and directed. Make: Kirloskar / Crompton |
| 9 | S&F Pump Guard set having flange with 19 mm SS rods fitted on pump with toching PVC rope from pump to ground level and steel well cap and MS clamp complete all as specified and directed. |
| 10 | Supply and fix submersible flat cable of size 4 sqmm 3 core, multistranded copper cable, conforming to IS:694:1990 with thimble complete all as specified and directed. |
| 11 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core, laid in trenches / duct / fixing on walls / poles or passing through HDPE double wall corrugated pipe (outer dia should not be less then 40 mm) including connecting with suitable lugs, glands, nuts and bolts in existing Panelfrom pole / Main Panel Box and testing complete all as specified and directed. Note:- HDPE pipe rate shall be deemed in quoted rate above. |
| 12 | Factory assembled hut type double door type with cable alloy outdoor LT panel suitable for 3 phase, fabricated out of CRCA sheet 3.15mm thick MS sheet tapered, drip proof, internally prewired top extended 100 mm on all sides including MS angle iron base frame of size 40x40x6mm thick duly welded with the following mountings/accessories & having individual compartment for switch gear connected and inter conneciton and painting with epoxy based primer and two coats of synthetic enamel paint withcontrol wiring and locking arrangement etc complete. (i) Busbar aluminium - 100 Amps -04 Nos (ii) MCCB 4 pole 100 Amp, 415V, 16KA,- 01 Nos (Incomer)(iii) Voltmeter ( 0-500V) digital tyype 3ph with selector switch - 01 Nos(iv) Ammeter (0-100 Amps) digital type, 3ph with CT\"s and selector switch(v) Indication lamp with LED type- Set of threeOutgoing : (vi) MCCB 4 pole 63 Amp, 415V, 16 kA ,with thermal magnetic release - 01 Nos(vii) MCB SPN 32 Amps, 240 volt, 10kA , \"C\" curve - 3 Nos(viii) Submersible single phase pump controller suitable for 3 HP motor |
| 13 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised iron strip 25 x 4 mm as earth leadby means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.. |
| 14 | S&F GI tubes \"medium grade\" 50 mm nominal bore with and including all fitings, laid in trenches complete all as specified and specified. |
| 15 | S&F Gun-metal, globe or gate valves, 15 mm with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 16 | Supply and fix of Non Return Valves size 50 mm bore, Cast Iron Body, flanged End including necessary joints, gasket with nut bolts complete all as specified and directed. |
| 17 | S&F cast iron, single orifice air valve 1\" fixed on submersible outlet pipe complete all as specified and directed. |
| 18 | M&L for cement concrete in foundations, filling and mass concrete using Type C2 1:3:6 (40 mm graded aggregate) at surrounding to borewell complete all as specified and directed. |
| 19 | Excavation in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation of poles/struts, stays, laying of cables, pipes etc and getting out in soft/loose soil complete all as specified and directed. |
| 20 | Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc. 25 cm in soft/loose soil complete all as specified and directed. |
| 21 | Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed. |
| 22 | Chemical test and Bacteriological test of water of borewell from the govt lab complete all as specified and directed. |
| 23 | S&F stainless steel sheet thickness not less than 2mm thick (Grade 304) size not less than 2 Sqm for kitchen platform, floor etc including all cut to size, holes punched, screws, clout nails, riveted or welded seams to steel framing with 40mm lap joints including bending or turning up, mitred angles, rubbing, polishing etc. fixed as per standard engineering practice and manufacturers recommendation complete all as specified and directed. |