| 1 | M&L for painting of DG setsincluding alternator, engine, radiator, chassis, muffler exhaust pipe complete with all accessories including panel boards, scrapping thoroughly the existing corroded paint and applying two coats of synthetic enamel paint complete and mentioned MES Nos on all DG sets of following capacity complete all as specified and directed by Engr-in-Charge. |
| 2 | All as per above item No. 1.00 but DG Set of capacity 82.5 KVA to 250 KVA |
| 3 | All as per above item No. 1.00 but DG Set of capacity 10 KVA to 35 KVA |
| 4 | M & L for general cleaning, check up & preventive maintenance, general servicing and B Check Services, reprogramming of control command circuit and testing of following capacity DG sets by Authorized OEM complete all as specified and directed by Engr-in-Charge :-Note :- (i) The general checking and preventive maintanance will include diesel filter , oil filter, air filter, checking of oil level, earthing connections, timer, contactor, fan belt, exhaust, silencer, alternator, fuel injector, solenoid valve, water pump, mother board, governor card, electrical wiring, all type of sensors, alternator,battery charger, dynamo etc. (ii) Rate quoted by the tenderer are also deemed to inclusive of replacement of minor parts like nut, bolts washers, lugs etc. oiling & greasing(iii) Major Parts/materials required against this item for repair shall be measured and paid separately under respective supply only items (iv) Labour required for replacement of such items shall be deemed to be included in the unit rate quoted against this item. |
| 5 | All as per above item No. 2.00 but DG set of capacity 10 KVA , Make : Kirlosker |
| 6 | All as per above item No. 2.00 but DG set of capacity 20 KVA/ 25 KVAMake : Kirlosker, Crompton Greeves |
| 7 | All as per above item No. 2.00 but DG set of capacity 35 KVA/82.5 KVA Make : Kirlosker |
| 8 | All as per above item No. 2.00 but DG set of capacity 125 KVA/160 KVAMake : Kirlosker, ITE |
| 9 | All as per above item No. 2.00 but DG set of capacity 200 KVA/ 250 KVAMake : Cummins, C&S |
| 10 | S&F for following capacity of heavy duty lead Acid batteries suitable for DG sets( Maintenance free battries with 2 year warrenty) including taking out old one, complete all as specified and directed by Engr-in-Charge:-Make :- Exide/ Amaron / Prestolite |
| 11 | All as per above item No. 3.00 but 80AH, 12 Volt . |
| 12 | All as per above item No. 3.00 but 180 AH, 12 Volt . |
| 13 | S&F and replacement fuel filter as per existing make and size, suitable for DG set of following capacity complete all as specified and directed by Engr-in-Charge:- |
| 14 | All as per above item No. 4.00 but DG set of capacity 10 KVAMake : Kirlosker |
| 15 | All as per above item No. 4.00 but DG set of capacity 20 KVA/ 25 KVAMake : Kirlosker, Crompton Greeves |
| 16 | All as per above item No. 4.00 but DG set of capacity 35 KVA/82.5 KVAMake : Kirlosker |
| 17 | All as per above item No. 4.00 but DG set of capacity 125 KVA/160 KVAMake : Kirlosker, ITE |
| 18 | All as per above item No. 4.00 but DG set of capacity 200 KVA/ 250 KVAMake : Cummins, C&S |
| 19 | S&F and replacement Lubricating Oil Filter as per existing make and size, suitable for DG set of following capacity complete all as specified and directed by Engr-in-Charge:- |
| 20 | All as per above item No. 5.00 but DG set of capacity 10 KVAMake : Kirlosker |
| 21 | All as per above item No. 5.00 but DG set of capacity 20 KVA/ 25 KVAMake : Kirlosker, Crompton Greeves |
| 22 | All as per above item No. 5.00 but DG set of capacity 35 KVA/82.5 KVAMake : Kirlosker |
| 23 | All as per above item No. 5.00 but DG set of capacity 125 KVA/160 KVAMake : Kirlosker, ITE |
| 24 | All as per above item No. 5.00 but DG set of capacity 200 KVA/ 250 KVAMake : Cummins, C&S |
| 25 | S&F and replacement Air Filter as per existing make and size, suitable for DG set of following capacity complete all as specified and directed by Engr-in-Charge.:- |
| 26 | All as per above item No. 6.00 but DG set of capacity 10 KVAMake : Kirlosker |
| 27 | All as per above item No. 6.00 but DG set of capacity 20 KVA/ 25 KVAMake : Kirlosker, Crompton Greeves |
| 28 | All as per above item No. 6.00 but DG set of capacity 35 KVA/82.5 KVAMake : Kirlosker |
| 29 | All as per above item No. 6.00 but DG set of capacity 125 KVA/160 KVAMake : Kirlosker, ITE |
| 30 | All as per above item No. 6.00 but DG set of capacity 200 KVA/ 250 KVAMake : Cummins, C&S |
| 31 | M & L for repairing and overhauling AVR( Automatic voltage regulator)transporting to work shop for carrying out overhauling by replacing all unserviceable spares including re-assembling and refixing the same to DG sets including testing complete all as specified and directed suitable for DG set of following capacity complete all as specified and directed by Engr-in-Charge.:- |
| 32 | All as per above item No. 7.00 but DG set of capacity 10 KVAMake : Kirlosker |
| 33 | All as per above item No. 7.00 but DG set of capacity 20 KVA/ 25 KVAMake : Kirlosker, Crompton Greeves |
| 34 | All as per above item No. 7.00 but DG set of capacity 35 KVA/82.5 KVAMake : Kirlosker |
| 35 | All as per above item No. 7.00 but DG set of capacity 125 KVA/160 KVAMake : Kirlosker, ITE |
| 36 | All as per above item No. 7.00 but DG set of capacity 200 KVA/ 250 KVAMake : Cummins, C&S |
| 37 | S&F in replacement of V belts for radiator fan/main shaft/cam shaft as per existing make and size suitable for DG set of following capacity complete all as specified and directed by Engr-in-Charge.:- |
| 38 | All as per above item No. 8.00 but DG set of capacity 10 KVAMake : Kirlosker |
| 39 | All as per above item No. 8.00 but DG set of capacity 20 KVA/ 25 KVAMake : Kirlosker, Crompton Greeves |
| 40 | All as per above item No. 8.00 but DG set of capacity 35 KVA/82.5 KVAMake : Kirlosker |
| 41 | All as per above item No. 8.00 but DG set of capacity 125 KVA/160 KVAMake : Kirlosker, ITE |
| 42 | All as per above item No. 8.00 but DG set of capacity 200 KVA/ 250 KVAMake : Cummins, C&S |
| 43 | S&F in replacement Power command control circuit / governor controller with LCD display having start / stop button/ reset with display of all information such running hours/ voltage / ampear/ oil pressure/ engine temperature, frequency, RPM, KW, KVA, Auto manual option , reset option for following capacity DG set complete all as specified and directed by Engr-in-Charge:- |
| 44 | All as per above item No. 9.00 but DG Set of capacity 82.5 KVA to 250 KVAMake : Kirlosker, ITE, Cummins, C&S |
| 45 | All as per above item No. 9.00 but DG Set of capacity 10 KVA to 35 KVAMake : Kirlosker, Crompton Greeves |
| 46 | S&F in repair mother board card (main base card) as per existing model and make for following capacity DG set complete all as specified and directed by Engr-in-Charge:- |
| 47 | All as per above item No. 10.00 but DG Set of capacity 82.5 KVA to 250 KVAMake : Kirlosker, ITE, Cummins, C&S |
| 48 | All as per above item No. 10.00 but DG Set of capacity 10 KVA to 35 KVAMake : Kirlosker, Crompton Greeves |
| 49 | S&F in replacement governer card as per existing model and make for following capacity DG set complete all as specified and directed by Engr-in-Charge. |
| 50 | All as per above item No. 11.00 but DG Set of capacity 82.5 KVA to 250 KVAMake : Kirlosker, ITE, Cummins, C&S |
| 51 | All as per above item No. 11.00 but DG Set of capacity 10 KVA to 35 KVAMake : Kirlosker, Crompton Greeves |
| 52 | M & L for drain out diesel from tank, cleaning of tank, refilling drained diesel including painting on outer surface with one coat of oil paint & indicating the Tank cleaning Date on outer surface of DG Set with the help of different colour of paint for following capacity DG set complete all as specified and directed by Engr-in-Charge :- |
| 53 | All as per above item No. 12.00 but DG Set of capacity 82.5 KVA to 250 KVAMake : Kirlosker, ITE, Cummins, C&S |
| 54 | All as per above item No. 12.00 but DG Set of capacity 10 KVA to 35 KVAMake : Kirlosker, Crompton Greeves |
| 55 | M & L for descaling of water jacket of engine by using descaling solution with pressure circulation pump, leakage testing, soldering, brazing recirculating with clear water for following DG set complete all as specified and directed by Engr-in-Charge. |
| 56 | All as per above item No. 13.00 but DG Set of capacity 82.5 KVA to 250 KVAMake : Kirlosker, ITE, Cummins, C&S |
| 57 | All as per above item No. 13.00 but DG Set of capacity 10 KVA to 35 KVAMake : Kirlosker, Crompton Greeves |
| 58 | M & L for repairing and overhouling including replacemnt of bearing, impeller of water pump suitable for following capacity DG set complete all as specified and directed by Engr-in-Charge. |
| 59 | All as per above item No. 14.00 but DG Set of capacity 82.5 KVA to 250 KVAMake : Kirlosker, ITE, Cummins, C&S |
| 60 | All as per above item No. 14.00 but DG Set of capacity 10 KVA to 35 KVAMake : Kirlosker, Crompton Greeves |
| 61 | S&F in replacement radiator hose pipe set for following capacity DG set with necessay accessories, O rings, clamps complete all as specified and directed by Engr-in-Charge. |
| 62 | All as per above item No. 15.00 but DG Set of capacity 82.5 KVA to 250 KVAMake : Kirlosker, ITE, Cummins, C&S |
| 63 | All as per above item No. 15.00 but DG Set of capacity 10 KVA to 35 KVAMake : Kirlosker, Crompton Greeves |
| 64 | Supply and filling distilled water in battery of different capacity complete all as specified and directed by Engr-in-Charge. |
| 65 | Supply and filling, Engine coolant in radiators of DG sets of cap 10 to 250 KVA as per DG set Manufacturer\"s recommendations at different locations, broght at site in sealed packets, complete all as specified and directed by Engr-in-Charge.Make:- SERVO, GOLDEN CRUISER, SHELL, TOTAL, BPL. |
| 66 | S &F in replacement of engine oil (15 W 40 ) suitable for DG set of capacity 10 KVA to 250 KVA complete all as specified and directed by Engr-in-Charge. Make :- Servo, Castrol,Total, Shell |
| 67 | M&L for dismantling the self starter 12 Volts DC of DG sets and transporting to work shop for carrying out overhauling by replacing all unserviceable spares including pinion, re-assembling and refixing the same to DG sets including testing complete all as specified and directed by Engr-in-Charge. |
| 68 | M&L for dismantling the self starter 24 Volts DC of DG sets and transporting to work shop for carrying out overhauling by replacing all unserviceable spares including pinion, re-assembling and refixing the same to DG sets including testing complete all as specified and directed by Engr-in-Charge. |
| 69 | S&F in replacement automatic battery charger heavy duty 240 V input , 24 V / 10-15 Amps output with auto cut off and floating with selector switch and indicators, set of fuses all as per existing model complete all as specified and directed by Engr-in-Charge. |
| 70 | Supply & fixing in replacementhigh pressure diesel Hose pipe of 1000 PSI to 1250 PSI of size upto 12.5 mm dia for connecting from diesel tank outlet to Engine complete with banjo bolt & washer all as per existing model complete all as specified and directed by Engr-in-Charge. |
| 71 | Taking out unserviceable asbestos rope from the exhaust pipe cleaning the exhaust pipe supply and wraping new asbestos rope of suitable size and wrapping with wire mesh and plasterig with plaster of paris /white cement for smooth finishing including replacement of gasket and tightening of all nut and bolts complete all as specified and directed by Engr-in-Charge. |
| 72 | S&F in replacement of Radiator of DG set including all connections and suitable accessories with water hose pipe suitable for following capacity DG Sets all as per existing model complete with testing complete all as specified and directed by Engr-in-Charge. |
| 73 | All as per above item No. 24.00 but DG Set of capacity 82.5 KVA to 250 KVAMake : Kirlosker, ITE, Cummins, C&S |
| 74 | All as per above item No. 24.00 but DG Set of capacity 10 KVA to 35 KVAMake : Kirlosker, Crompton Greeves |
| 75 | Taking out defective fuel injection pump of DG sets transporting to work shop and cleaning of injectors nozzles and overhauling complete including calibrating and re-fixing the same including testing the DG Set complete all as specified and directed by Engr-in-Charge for DG set of following capacity :- |
| 76 | All as per above item No. 25.00 but DG set of capacity 10 KVAMake : Kirlosker |
| 77 | All as per above item No. 25.00 but DG set of capacity 20 KVA/ 25 KVAMake : Kirlosker, Crompton Greeves |
| 78 | All as per above item No. 25.00 but DG set of capacity 35 KVA/82.5 KVAMake : Kirlosker |
| 79 | All as per above item No. 25.00 but DG set of capacity 125 KVA/160 KVAMake : Kirlosker, ITE |
| 80 | All as per above item No. 25.00 but DG set of capacity 200 KVA/ 250 KVAMake : Cummins, C&S |
| 81 | M&L for rewinding of armature of dynamo/alternator of DG set of capacity upto 35 KVA with \"H\" class copper wire as per existing gauge dismantling the old coil cleaning throughly winding with super enameled copper conductor of existing size and gauge, varnishing drying and fixing back with dynamo alternator properly testing and commissioning complete all as specified and directed by Engineer-in-Charge. |
| 82 | M&L for rewinding of armature of dynamo/alternator of DG set of capacity 82.5 KVA to 250 KVA with \"H\" class copper wire as per existing gauge dismantling the old coil cleaning throughly winding with super enameled copper conductor of existing size and gauge , varnishing drying and fixing back with dynamo alternator properly testing and commissioning complete all as specified and directed by Engr-in-Charge. |
| 83 | M & L for complete checking of AMF panel, syncronization panel installed for DG set of capacity upto 250 KVA ,Make Kirloskar, finding the fault , servicing complete including replacement of minor unservisible spares, relays 10 pin / 12 pin / 15 pin , Power contactor coils, automatic float cum boost charger, ACB Shunt release tripping coil, ACB closing coil as per site requirement, testing complete for manual & Auto operations complete all as specified and directed by Engr-in-Charge.Note :- (i) The spare parts required to be replaced shall be measured and paid for separately as \"Supply only\" under the relevant item here in after. (ii) Unit rate shall be deemed to include for all minor spares /extras. |
| 84 | All as per above item No. 28.00 but Supply only Electronic timers with auxilary voltage of 110/240/415v 50Hz for operation of 12-120 secs as existing for DG Set upto capacity 250 KVA Cummins AMF Panel complete all as specified and directed by Engr-in-Charge. |
| 85 | All as per above item No. 28.00 but Supply only ACB Shunt release /tripping coil of 110 V/ 240 V as existing for DG Set upto capacity 250 KVA Cummins DG Set AMF Panel complete all as specified and directed by Engr-in-Charge. |
| 86 | All as per above item No. 28.00 but Supply only Auxilary control Contactors /relayswith Add On\"s as existing for DG Set upto capacity 250 KVA Cummins DG Set AMF Panel complete all as specified and directed by Engr-in-Charge. |
| 87 | All as per above item No. 28.00 but Supply only ACB Closing coll of 110V/240V as existing for DG Set upto capacity 250 KVA Cummins DG Set AMF Panel complete all as specified and directed by Engr-in-Charge. |
| 88 | All as per above item No. 28.00 but Supply only of the following power contactors Coils operatable at 110V/230V/440V 50Hz Supply as existing for DG Set upto capacity 250 KVA Cummins DG Set AMF Panel complete all as specified and directed by Engr-in-Charge. |
| 89 | All as per above item No. 28.00 but Supplyonly relay 10 pin/12 pin/15 pin as per existing DG Set upto capacity 250 KVA AMF.Panel complete all as specified and directed by Engr-in-Charge. |
| 90 | S&F battery leads of PVC insulated sheathed multi core copper conductor 16 Sqmm (nominal area) heavy duty cable 2.0 m long with copper lugs duly crimped & soldering, including taking out old u/s lead and removal, complete all as specified and directed by Engr-in-Charge. |
| 91 | S&F battery terminal of brass with existing colour code or marking (+)/(-) & fixed in position & testing, including taking down and removal, complete all as specified and directed by Engr-in-Charge. |
| 92 | S&F in replacement Solenoid Switch and start/stop relay card all as per existing model and testing complete all as specified and directed by Engr-in-Charge for DG sets of following capacity:- |
| 93 | All as per above item No. 31.00 but DG set of capacity 10 KVAMake : Kirlosker |
| 94 | All as per above item No. 31.00 but DG set of capacity 20 KVA/ 25 KVAMake : Kirlosker, Crompton Greeves |
| 95 | All as per above item No. 31.00 but DG set of capacity 35 KVA/82.5 KVAMake : Kirlosker |
| 96 | All as per above item No. 31.00 but DG set of capacity 125 KVA/160 KVAMake : Kirlosker, ITE |
| 97 | All as per above item No. 31.00 but DG set of capacity 200 KVA/ 250 KVAMake : Cummins, C&S |
| 98 | S&F in replacement Rectifier Diode assembly complete suitable to match the existing DG set alternator excitor unit all as specified for DG sets of following capacity :- |
| 99 | All as per above item No. 32.00 but DG set of capacity 10 KVAMake : Kirlosker |
| 100 | All as per above item No. 32.00 but DG set of capacity 20 KVA/ 25 KVAMake : Kirlosker, Crompton Greeves |
| 101 | All as per above item No. 32.00 but DG set of capacity 35 KVA/82.5 KVAMake : Kirlosker |
| 102 | All as per above item No. 32.00 but DG set of capacity 125 KVA/160 KVAMake : Kirlosker, ITE |
| 103 | All as per above item No. 32.00 but DG set of capacity 200 KVA/ 250 KVAMake : Cummins, C&S |
| 104 | Removal of the defective change over switch of the DG sets and Supply fixing in repairsManual onload change over switch in stainless steel enclosure with auxilary contacts operatable at 415 V, 50Hz supplywith enlosure operatable handle, 4 pole 200 A complete all as specified and directed by Engr-in-Charge. |
| 105 | S&F in replacement Oil pressure gauge ISI mark for DG Set upto capacity 250KVA all as per existing model complete all as specified and directed by Engr-in-Charge. |
| 106 | S&F in replacement Oil temperature gauge ISI mark for DG Set upto capacity 250KVA all as per existing model complete all as specified and directed by Engr-in-Charge. |
| 107 | M&L for dismantling of Exhaust pipe of silencer, cleaning of silencer to remove carbon deposit inside exhaust pipe and refixing including replacement of worn out rubber gasket packing and nut,bolts complete all as specified and directed by Engr-in-Charge. |
| 108 | S&F in replacement oil pressure sensor all as per existing model as complete all as specified and directed by Engr-in-Charge for DG sets of following capacity :- |
| 109 | All as per above item No. 37.00 but DG Set of capacity 82.5 KVA to 250 KVAMake : Kirlosker, ITE, Cummins, C&S |
| 110 | All as per above item No. 37.00 but DG Set of capacity 10 KVA to 35 KVAMake : Kirlosker, Crompton Greeves |
| 111 | S&F in replacement coolant temp sensor all as per existing model, complete all as specified and directed by Engr-in-Charge for DG sets of following capacity :- |
| 112 | All as per above item No. 38.00 but DG Set of capacity 82.5 KVA to 250 KVAMake : Kirlosker, ITE, Cummins, C&S |
| 113 | All as per above item No. 38.00 but DG Set of capacity 10 KVA to 35 KVAMake : Kirlosker, Crompton Greeves |
| 114 | S&F in replacement magnetic pick up speed/rpm sensor all as per existing model,complete all as specified and directed by Engr-in-Charge for DG sets of following capacity :- |
| 115 | All as per above item No. 39.00 but DG Set of capacity 82.5 KVA to 250 KVAMake : Kirlosker, ITE, Cummins, C&S |
| 116 | All as per above item No. 39.00 but DG Set of capacity 10 KVA to 35 KVAMake : Kirlosker, Crompton Greeves |
| 117 | S&F in replacement of electrically operated fuel shut down valve assembly all as per existing model complete testing and commissioning complete all as specified and directed by Engr-in-Charge for DG sets of following capcity :- |
| 118 | All as per above item No. 40.00 but DG Set of capacity 82.5 KVA to 250 KVAMake : Kirlosker, ITE, Cummins, C&S |
| 119 | All as per above item No. 40.00 but DG Set of capacity 10 KVA to 35 KVAMake : Kirlosker, Crompton Greeves |
| 120 | S&F in replacement MCCB 3 Pole 25-100Amp, fixed type, 440 V, 3 phase, 50 Hz, 16 KA with complete accessories including wiring, thimbles, etc complete all as specified and directed by Engr-in-Charge. |
| 121 | S&F in replacement MCCB 3 Pole 160 Amp, adjustable type 440 V, 3 phase, 50 Hz, 36 KA with complete accessories including wiring, thimbles, etc complete all as specified and directed by Engr-in-Charge. |
| 122 | S&F in replacement ignition switch and key as per existing complete all as specified and directed by Engr-in-Charge. for DG Sets of following capacity :- |
| 123 | All as per above item No. 43.00 but DG Set of capacity 82.5 KVA to 250 KVAMake : Kirlosker, ITE, Cummins, C&S |
| 124 | All as per above item No. 43.00 but DG Set of capacity 10 KVA to 35 KVAMake : Kirlosker, Crompton Greeves |
| 125 | Supply and Laying Cable XLPE insulated screened PVC bedded galvanized steel strips or wire armoured cables (heavy duty) ISI marked with stranded aluminium conductor 1100 volts grade and connecting and testing in trenches, under floors/ roads or on walls including taking down old cable of following including taking down old one complete all as specified and directed by Engr-in-Charge.Make:- Havells/Paraflex Note :- Earth work, excavation shall be measured & paid separately under respective item of schedule |
| 126 | All as per above item No. 44.00 but Size 70 Sqmm 3.5 core |
| 127 | All as per above item No. 44.00 but Size 35 Sqmm 3.5 core |
| 128 | All as per above item No. 44.00 but Size 16 Sqmm 4 core |
| 129 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation for laying cable etc and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge. |
| 130 | Returning,filling in and including spreading levelling watering and well ramming in layers n.exc 25cm complete all as specified and directed by Engr-in-Charge. |
| 131 | Removing of excavated material (soil) to a distance n.exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge. |
| 132 | M&L bricks for protection cover to under ground cable (with old size sub class \"B\" bricks) laid flat abutting each other with width of protection being equal to length of brick. The gap between should not exceed 10 mm, complete all as specified and directed by Engr-in-Charge. |
| 133 | M&L for dry river sand and punning for cushioning and cover for protection of under ground electric cable, complete all as specified and directed by Engr-in-Charge. |
| 134 | M&L for dismantling old earthing and Supply, installation and testing earthing complete with galvanised iron earth plate electrode of size 60 cm×60 cm.× 6mm thick, buried directly in ground (earth pit not lessthan 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to and including GI Strip 32 x 6 mm (upto the body of equipment) by means ofGI bolts/nuts/washers, protected by 40 mm boreGI medium grade pipe.Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, RCC cover & frame, PCC (1:3:6) type C-2 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation and earth work , complete all as specified and directed by Engr-in-Charge and shown in electrical plate No 3 of MES Schedule Part-I. Notes :-(i) PCC Chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting maner.(ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.(iii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. |
| 135 | M & L for Repairs and calibration of PT fuel pump as per the calibration procedure and norms as per manufacture\"s guide lines for DG Set of capacity 82.5 KVA to 250 KVA (Make - Cummins) including replacement of worn out and unserviceable Ó\"rings /shutt off valve/Plungers as per existing model complete all as specified and directed by Engr-in-Charge. |
| 136 | M & L for Repairs and calibration of PT fuel pump as per the calibration procedure and norms as per manufacture\"s guide lines for DG Set of capacity 10 KVA to 35 KVA including replacement of worn out and unserviceable Ó\"rings /shutt off valve/Plungers as per existing model complete all as specified and directed by Engr-in-Charge. |
| 137 | M & L for draining existing radiator, cleaning thoroughly the radiator fins by air blower, finding out leakage, repairing by soldring / brazing/ welding including replacement of all water hose pipe suitable for 10 KVA to 35 KVA DG Sets as per existing model complete all as specified and directed by Engr-in-Charge. |
| 138 | M & L for draining existing radiator, cleaning thoroughly the radiator fins by air blower, finding out leakage , repairing by soldring / brazing/ welding including replacement of all water hose pipe suitable for 82.5 KVA to 250 KVA DG Sets as per existing model complete all as specified and directed by Engr-in-Charge. |
| 139 | M & L for complete replacement of the defective, ETR fuel control actuator for DG Set upto capacity 250 KVA as per existing make along with connected \"O\" Rings, electrical harness cable connections complete testing and commissioning as per existing model complete all as specified and directed by Engr-in-Charge. |
| 140 | M & L for complete replacement of Governor Barrle plunger for DG Set upto capacity 250 KVA engine as per existing make complete testing and commissioning as per existing model complete all as specified and directed by Engr-in-Charge. |
| 141 | Supply, install, testing and commissioning of Bus bar chamber of size 60 cm x 60cm x 40 cm outdoor type suitable for LT 415 volts 3 phase 4 wire system factory made cubical complete materialised dust and vermin proof (protection class IP 54), made out of 3.15mm thick MS sheet (CRCA) including factory made hinged type door both side opening with locking arrangement duly painted with two coats of synthetic enamel paint with powder coated finish over a coat of zinc chrome primer with inclusive of PCC platform of suitable size 45cm height and 4 Nos legs of 50mmx50mmx6mm and 60 cm in height for fixing the panel complete all as specified and directed by Engineer-In-Charge. , the panel board shall be comprising of the following (incl below 57.01 Notes) accessories:-(i) Aluminium bus bar capacity 600 Amp : 04 Nos(ii) MCCB four pole with thermal magnetic release adjustable type with breaking capacity 36 KA 400 Amp : 01 No (incoming), Make :-L&T, Legrand, Schneider, seimens, C&S (iii) Digital Voltmeter-96 x 96 mm flush type 0-500V with selector switch : 01 No(iv) Digital Amp meter96 mm X 96 mm flush type 0-100 Amps with selector switch with CT : 01 No(v) RYB neon indicating lamp set of three :01 |
| 142 | All as per above item No. 57.00 but NOTES :-(i) Make of Panel :-Universal/Standard/Havells /L&T(ii) Danger notice plate (02 Nos) in Hindi and English ofsize 20cmx 15cm shall be fixed on the panel(iii) Contractor provided power coated finish paint on panel and test certificate /CPRI Approval certificate. |
| 143 | M & L for Repairs and calibration of UPS Power Inverter as per the calibration procedure and norms as per manufacture\"s guide lines for Inverter Set of capacity 5.5 KVA to 6.5 KVA (Make - Microtek) including replacement of worn out and unserviceable parts Transistors/Control Logic Circuit/Step Up Transformer etc. to make inverter functional including testing complete all as specified and directed by Engr-in-Charge. |
| 144 | S&F heavy duty Tubular Inverter battery of capacity 180AH of lead Acid type suitable for Office/Hospital Area(Maintenance free battries with 2 year warrenty) including taking out old one complete all as specified and directed by Engr-in-Charge. Make :- Exide IMTT1800 / Amaron |
| 145 | Total in Figures |
| 146 | Quoted Amount in Words |