| Sl. No. | Item Description |
| 1 | Dismantling and taking out burnt winding by cutting, cleaningslots and re-winding of AC ceiling fan motor 1200mm of any make of fan with super enameled copper winding wire of existing gauge including, sleeve work, varnishing with E class insulation varnish, complete all as specified and directed including taking down & refixing the same.Note :- (i) Motor shall be wound with machine only.(ii) super enameled copper winding wire shall only be used. |
| 2 | Replacement of old unserviceable gun metal bush of ceiling fan complete all as specified and directed. |
| 3 | Replacement of old unserviceable capacitor 2.5 mfdISI marked complete all as specified and directed |
| 4 | All as per Serial item No. 3 here-in-above but 3.15mfd complete all as specified and directed. |
| 5 | Replacement of old unserviceable ball bearing suitable for 1200 mm sweep ceiling fan complete all as specified and directed. |
| 6 | Replacement of old unserviceable shackle assy kit (rubber real -01, MS split clamp two Nos, nuts and bolts washers 2 Nos & split pin -02 Nos) suitable for ceiling fan 1200/1400mm sweep complete all as specified and directed. |
| 7 | Replacement of old unserviceable fan blades, ISI Marked, suitable for 1200/1400mm sweep ceiling fan of any make complete all as specified and directed. |
| 8 | Replacement of old unserviceable MS down rod of appropriate External dia of ceiling fan complete (length of rod not less than 45cm and not more than 60cm and 15 mm dia) complete all as specified and directed. |
| 9 | S&F Canopy for ceiling fan as per existing sample complete all as specified and as directed. |
| 10 | S&F PVC Two way connector for ceiling fan complete all as specified and directed. |
| 11 | Replacement of old unserviceable steel screw (to be used for fixing of fan blade) as per sample/site requirement of fan complete all as specified and directed. |
| 12 | Servicing of ceiling fans of capacity 1200 mm including taking down from site, dismantling, cleaning, greasing/oilingof bush and bearings, replacement of set of split pins, cotter pins, blade screws and refixing to the existing site after servicing complete all as directed by Engr-in-Charge. (Unserviceable parts if any will be measured and paid separately). |
| 13 | Dismantling and taking out burnt BLDC ceiling fan Driver card with Replacement to new BLDC ceiling fan Driver card of AC ceiling fan1200mm of any make of fan complete all as specified and directed including taking down & refixing the same. |
| 14 | Supply only 1200 mm BLDC ceiling fan remote suitable for as per existing fan complete all as specified and as directed. |
| 15 | S&F cable PVC insulated and overall sheathed with flexible copper conductor Single core of size 1.0 sqmm complete all as specified and directed. |
| 16 | Dismantling and Re-winding of exhaust fan/industrial fan motor 250-300 mm sweep any make of fan with super enameled copper winding wire of suitable gauge as per existing including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections fan complete all as specified and directed.Note :- (i) Motor shall be wound with machine only.(ii) Super enameled copper winding wire shall only be used. |
| 17 | All as per Serial item No.16 here-in-above but 350mm-450mm sweep complete all as specified and directed. |
| 18 | Dismantling of wall/pedestal fan of any sweep, repair the same by cleaning, overhauling, necessary lathe work (grinding & polishing) etc. and taking out existing burnt out winding wire of motor and rewinding the same with super enamelled bare insulated copper winding wires as per existing gauge and turn to achieve desiredRPM including necessary insulating materials, insulating varnishing, cleaning and reassembling the wall/pedestal fanafter replacement of unserviceable minor parts such as frame nut, knob, regulator switch clamp of condenser etc. as required for smooth functioning of the fan and Replacement of unserviceable major parts like capacitor, bearing, bush etc.and testing complete on completion and re-fixing the fan in existing positionincluding provn of twin twisted flexible copper stranded conductor wire of size 23/0.0076 Sqmm of required length complete as directed by the Engineer-in-Charge. Note : (a) Replacement of unserviceable major parts like capacitor, bearing, bush etc. shall be measured and paid separately as \"Supply only\" under respective items of this Schedule. (b) Unit quoted rate shall deemed to be inclusive of transportation of fan to workshop form MES store yard. |
| 19 | S&F louver, suitable for exhaust fan of any make and size upto 300-350 mm, fixed in repair complete all as specified and as directed. |
| 20 | All as per serial item No. 19 here-in-above but of size 400 mm-450 mm. |
| 21 | Removing old paint by scraping with sand paper including washing and filling cavities with filter and applying two coats of painting to ceiling fan 1200mm sweep at site with synthetic enamel paint by spray painting complete all as specified and directed. |
| 22 | Removing old paint by scraping with sand paper including washing and filling cavities with filter and applying two coats of painting to exhaust fan/wall mounting fan/Padestial Fan of any sweep at site with synthetic enamel paint by spray painting complete all as specified and directed. |
| 23 | S&F in repair ceiling fans 1200 mm Sweep Ceiling Fan, Energy Saving, BLDC Motorwithout remote complete with regulator, canopy, blades, down rod, split pin etc. complete of approx wattage 30 to 32 Watt rated suitable for operation on AC 220-240 V AC, 50 HZ, PF >0.95, Air delivery approx 230 cum/min including dismantling old UNSV fan and depositing to MES store yard complete all as specified and directed. |
| 24 | S&F in repair Ventilation fan AC single phase 230/240 volts of size 150 mm sweep PVC body with louvreincluding connecting to ceiling rose and dismantling old UNSV fan and depositing to MES store yard all as specified and directed. |
| 25 | S&F in repair Ventilation fan AC single phase 230/240 volts of size 200 to 250 mm sweep PVC body with louver including connecting to ceiling rose and dismantling old UNSV fan and depositing to MES store yard all as specified and directed. |
| 26 | S&F Exhaust fan AC single phase 230/240 volts of size 300 mm sweep steel body with louverincluding connecting to ceiling roseand dismantling old UNSV fan and depositing to MES store yard all as specified and directed. |
| 27 | S&F Exhaust fan AC single phase 230/240 volts of size 450 mm sweep steel body with louverincluding connecting to ceiling roseand dismantling old UNSV fan and depositing to MES store yard all as specified and directed. |
| 28 | S&F in repair wall mounted fan 400 mm Sweep Energy Saving, copper wounded Motor, three speed control completesuitable for operation on AC 220-240 V AC, 50 HZ, PF >0.95, Air delivery approx 230 cum/min including dismantling old UNSV fan and depositing to MES store yard. |
| 29 | Disconnecting the inlet/outlet water connections and electric connections of Storagestorage type electric water heater of capacity 25 Ltrs capacity, taking down carefully from wall after unscrewing nut/bolts ,checking the outer body for any cracks and strip opening the same carefully for thorough inspection of serviceability/functionality of parts such as internal tank, syphon assembly, thermostat switch, heating element, glass wool etc., servicing complete and re-assembling and re-fixing after repair, fixing to wall testing, installation and commissioning all as directed. Note: (a) The spares required for replacement shall be measured and paid under relevant Schedule items of Sch here-in-after. |
| 30 | Supply only syphon assembly made out of SS of 25 ltr capacity including necessary studs screws and rubber gasket/washers matching with existing/new inner tank complete all as specified and directedfor carrying out repairs under relevant item No. 29. |
| 31 | Supply only thermostat switch ISI marked forstorage type electric water heater AC 230 volt adjustable range from 0-90 degree Celsius)for carrying out repairs under relevant item No. 29. |
| 32 | Supply only cup/ triangulartypestorage type electric water heater element AC 230 volt, of rating 1500/2000 wattfor carrying out repairs under relevant item No. 29 |
| 33 | Supply only indicator lamp square/roundtype suitable forstorage type electric water heater 25 ltr all as per sample AC 230 Voltfor carrying out repairs under relevant item No. 29. |
| 34 | Supply and replacement cable flexible PVC insulated, PVC sheathed, copper conductor, 3 core 70/.0076mm complete all as specified and directed. |
| 35 | S&F sheet metal enclosure single pole and neutral with a 2 pin and earth plug and socket 20 A 240V complete with one single pole MCB of capacity 20 A complete all as specified and directed. |
| 36 | De-scaling ofstorage type electric water heater of capacity 25 ltr after taking down thestorage type electric water heater from wall, strip opening the assembly, de-scaling the syphon assembly and refixing the assembly and re-installation ofstorage type electric water heater complete all as directed by Engineer-in –Charge. |
| 37 | S&F PVC connection 15 mm size with PTMT nuts of length 450 mm ISI Marked complete all as specified and directed. |
| 38 | Replacement of safety valve/ dead wt. valve ISI marked suitable for 25 Ltrs capacitystorage type electric water heaters complete all as specified and directed. |
| 39 | S&F gun metal glove or gate valves with iron wheel head, screwed both ends for iron pipe and fixed of size 15mm complete all as specified and directed. |
| 40 | S&F anchor boltsuitable for geyser/Exhaust fan complete all as specified and directed.(Note:- Anchor bolt shall be grouted with hammer drill only) |
| 41 | Supply and replacement of brass non return valve suitable for 25 ltrstorage type electric water heater of size 15 mm complete all as specified and directed. |
| 42 | Dismantling of Insulated hot water storage tank of capacity up to 500 Ltrs connected Solar Evacuated collectors/flat collectors and cold water tank with GI fittings & PVC pipe connection. Servicing, Testing, Commissioning & descaling of Hot water storage tank removing of corrosion/dust, replacement of UNSV PVC pipe after re-fixing the same, complete all as specified and directed. |
| 43 | Service and descaling of Solar Evacuated tube Collector/Flat collectors with sulphuric acid by forcefully injecting the hot chemical into collector for number of times to clean the Solar Evacuated tube Collector/Flat Plate Collector and assembled the same, complete all as specified and directed. |
| 44 | S&F in replacement of Evacuated tube collector for Solar Water Heater of capacity Upto 500 LPD of suitable size as per sample approved by Engineer -in-charge on the ground. |
| 45 | Replacement of heating element2/3 KW suitable for stand by back up supply to solar water heater, complete all as specified and directed. |
| 46 | M&L for replacement of unserviceable Ball valves 15 mm and S&F Ball valves , cast copper allow, screwed down, high pressure, with polythene float and flynut complete, screwed for iron pipe, complete all as specified and directed. |
| 47 | M&L for replacement of unserviceable Ball valves 20 mm and S&F Ball valves , cast copper allow, screwed down, high pressure, with polythene float and flynut complete, screwed for iron pipe, complete all as specified and directed. |
| 48 | Dismantling old unserviceable storage type electric water heater and depositing it to MES store yard. Supply, install, testing and commissioning ofstorage type electric water heater of 25 ltr capacity, BEE 5 star rated suitable for 8 bar pressure with nano polymer coated tank, incoloy heating element, rust proof ABS body etc. complete all as specified and directed.(Note : Rate quoted deemed to be inclusive of anchor bolt, and PVC connection) |
| 49 | Dismantling old unserviceable storage type electric water heater and depositing it to MES store yard. Supply, install, testing and commissioning ofstorage type electric water heater of 50 ltr capacity, BEE 5 star rated suitable for 8 bar pressure with nano polymer coated tank, incoloy heating element, rust proof ABS body etc. complete all as specified and directed. (Note : Rate quoted deemed to be inclusive of anchor bolt, and PVC connection) |
| 50 | Disconnecting thewater connections and electric connections of Desert coolers of capacity 3000 CFM to 5000 CFM, taking down carefully from stand/ CC supports ,checking the outer body for any damage and strip opening the same carefully for thorough inspection of serviceability/functionality of parts such as fan assembly with motor (blower assly),water pump, khas khas pad , control wiring , selector switch etc., servicing complete and re-assembling and re-fixing after repair, fixing to wall testing, installation and commissioning all as directed. Note: (a) The spares required for replacement shall be measured and paid under relevant Schedule items of Sch here-in-after.(b) Any other minor spares such as nut bolts, screws, piano switch, indication lamp replacement required is deemed to beincluded in quoted rate. |
| 51 | Supply only wiring for desert cooler including all accessoriesall complete directed for carrying out repairs under relevant item, complete all as specified and directed. |
| 52 | Supply only blower motor ofsingle way shaft 240 Volts 50 c/s of suitable capacityfor desert cooler of capacity 3000 CFM to 5000 CFM single way shaft 240 Volts 50 c/s complete all as specified and directed for carrying out repairs under relevant item, complete all as specified and directed. |
| 53 | Supply only water circulation pump suitable for desert cooler of capacity 3000 CFM to 5000 CFM240 volts 50 c/s single phase complete all as specified and directed for carrying out repairs under relevant item. |
| 54 | Supply only Khaskhas pad honey bee type (set of 3) for Desert Cooler of any capacity ( Set of three) complete all as specified and directed for carrying out repairs under relevant item. |
| 55 | M&L in replacement of Fan blade hub assly only for Blower motor of desert cooler made of alloy/Forged steel suitable for 3000 to 5000 cfm capacityDesert Cooler complete all as specified and directed |
| 56 | M&L in replacement of Leg set complete for fixing blower motor for desert cooler complete with all necessary fixing/Fastening arrangements(As per sample) suitable for 3000 to 5000 cfm capacityDesert Cooler complete all as specified and directed |
| 57 | M&L in replacement ofwater distributor and PVC pipe connection for water connection of desert cooler 3 piece (length not less than 35 cm each piece)(As per sample) suitable for 3000 to 5000 cfm capacityDesert Cooler complete all as specified and directed |
| 58 | M&L in replacement of Capacitor of capacity 4mfd suitable for desert cooler complete all as specified and directed. |
| 59 | Dismantling old defective desert cooler and depositing to MES store yard. Supply, installation, testing and commissioning of desert cooler electric driven, single phase of approx minimum size 575x575x800 mm made out of 0.8 mm thick GI sheet for body, with water tank of capacity50 Ltr made out of 1 mm thick and with front grills and side direction grills, suitable for minimum air Delivery- 4000 Cum/hr, approx 450 mm sweep fan size with mild steel curved blades duly painted with synthetic anti corrosive paint, fitted to body including prewired electric 4 speed switch control and one 6Amps piano switch. Water immersed pump of suitable capacity 1300 RPMrated suitable for 230 volts, 50 Hz AC supply and one 6 Amps piano switch with fan motor of minimum capacity 105 watt, 1400 RPM, 230 volts, 50 Hz and water inlet pipe with brass float valve of size 15mm and outlet with brass drain plug of 20mm. The pad of 3 sides shall be of honeycomb type, including standof minimum height 900 mm made out 25mm x 25mm x 3mm MS angle iron, duly coated with weather proof paint of black colour, complete all as specified and directed. |
| 60 | S&F plug top polycarbonate 3 pin, 15Amp all as specified and directed. |
| 61 | S&F plug top polycarbonate 3 pin, 5 Amp all as specified and directed. |
| 62 | S&F of2.5 sqmm 3 core copper conductor wire minimum 2.5 meter length with plug top polycarbonate 3 pin, 5Amp complete all as specified and directed. |
| 63 | Taking down carefully aluminum/copper point wiring (light fan socket or power) complete with fitting such as switches, tube lights, ceiling rose, pendants, regulators, MCB DB, MCB\"S, Main switch from control board and making good disturbed surfaces of walls, floor to match with existing specification complete all as specified and directed. |
| 64 | M&L for point wiring with FRLS PVC insulated fire retardant stranded copper conductor cable of 1.5 sqmm in FRLS PVC concealed conduitheavy duty and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc. ) made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and drawing 1.5 sqmm PVC insulated fire retardant stranded copper conductor cable as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and directed.( In ceiling Portionsurface conduit wiringshall be carried out.) |
| 65 | All as per serial item No. 64 here-in-above but in existing conduit and pressed steel terminal boxes, complete all as specified and directed. |
| 66 | All as per serial item No. 64 here-in-above but for one light point controlled by 2 nos two way switches. |
| 67 | All as per serial item No. 66 here-in-above but in existing conduit and pressed steel terminal boxes |
| 68 | All as per serial item No. 64 here-in-above but for one 3 pin 5A socket outlet independent board. |
| 69 | All as per serial item No. 68 here-in-above but in existing conduit and pressed steel terminal boxes |
| 70 | All as per serial item No. 64 here-in-above but for one 5A socket outlet on the same board |
| 71 | All as per serial item no. 70here-in-above but in existing conduit and pressed steel terminal boxes |
| 72 | All as per serial item no. 64 here-in-above but for one 5A socket outlet below the board. |
| 73 | All as per items 72 here-in-above but in existing conduit and pressed steel terminal boxes |
| 74 | All as per serial item No 64 here-in-before but for 15/16 Amps socket out let independent with 4.0 sqmm copper conductor and –ditto-. |
| 75 | All as per item no. 74 here-in-above but in existing conduit and pressed steel terminal boxes |
| 76 | M&L for replacement of existing un-serviceable switch with switch piano polycarbonate bodyflush button single pole two way 5 amps, 230 volts, complete all as specified and directed.\ |
| 77 | M&L for replacement of existing un-serviceable switch with switch piano polycarbonate bodyflush button single poleone way 15 amps, 230 volts, complete all as specified and directed. |
| 78 | M&L for replacement of existing old u/s switch with switch piano polycarbonate body type single pole one way 5/6 Amp, 230 volts, complete all as specified and directed. |
| 79 | M&L for replacement of existing old u/s switch socket combination with socket combination Polycarbonate body 2 in 1, 3 pin, 5 Amp and 15 Amp flush type complete all as specified and directed. |
| 80 | M&L for replacement of existing old u/s switch socket combination with socket combination Polycarbonate body ,5 pin , 5 Amp flush type complete all as specified and directed. |
| 81 | M&L for replacement of existing old u/s socket outlet with socket outlet Polycarbonate body , 5 pin 5 Amp flush type complete all as specified and directed. |
| 82 | M&L for replacement of existing old u/s bell push with bell push polycarbonate body type 5/6 Amp, 230 volts complete all as specified and directed. |
| 83 | M&L for bell electric heavy duty Ding Dong type 230 volts single pole complete and all as specified. |
| 84 | M&L for replacement of existing old u/s fan regulator with fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically complete all as specified and directed. |
| 85 | M&L for replacement of fan regulator suitable for BLDC fan and connecting electrically complete all as specified and directed. |
| 86 | M&L for replacement of existing old u/s switch socket combination with socket combination Polycarbonate body, 5 pin, 5 Amp flush type with PVC box complete all as specified and directed. |
| 87 | M&L for replacement of existing old u/s switch socket combination with socket combination Polycarbonate body, 5 pin, 15 Amp flush type with PVC box complete all as specified and directed. |
| 88 | M&L for replacement of existing old u/s ceiling rose with ceiling rose Polycarbonate body surface bakelite 2 to 3 terminals, 230 volts, complete all as specified and directed. |
| 89 | S&F for replacement of existing old u/s lamp holder with lamp holder batten type polycarbonate body with back plate for batten fitting complete all as specified and directed. |
| 90 | M&L for Modular point wiring with FRLS PVC insulated fire retardant stranded copper conductor cable of 1.5 sqmm in FRLS PVC concealed conduitheavy duty and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc. ) made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and drawing 1.5 sqmm PVC insulated fire retardant stranded copper conductor cable as earth continuity wire in green colour connected to common earth and each terminal box/fitting complete all as specified and directed.(In ceiling Portionsurface conduit wiringshall be carried out.) |
| 91 | All as per serial item no 90 here in above but for one 3 pin module socket out let 5/6 Amps on same board. |
| 92 | All as per serial item no 90 here in above but for one module socket out let 5/6 Amps on Independent board. |
| 93 | All as per serial item no 90 here in above but for one module socket out let 5/6 Amps on below the board. |
| 94 | All as per serial item no 90 here-in-before but for 15/16 Amps socket out let independent with 4 sqmm copper conductor and –ditto-. |
| 95 | M&L for replacement of existing un-serviceable switch piano with Modular switch 1 way 6A, 1 module ISI marked complete all as specified and directed. |
| 96 | M&L for replacement of existing un-serviceable switch piano with Modular switch 2 way 6A, 1 module ISI marked complete all as specified and directed. |
| 97 | M&L for replacement of existing un-serviceable switch piano with Modular switch 1 way 16A, 1 module ISI marked complete all as specified and directed. |
| 98 | M&L for replacement of existing un-serviceable bell push with Modular bell push 6A, 1 module ISI marked complete all as specified and directed. |
| 99 | M&L for replacement of existing un-serviceable socket outlet with Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed. |
| 100 | M&L for replacement of existing un-serviceable socket outlet with Socket, 16A - 2/3 pin combined 2 module complete all as specified and directed. |
| 101 | M&L for replacement of existing un-serviceable fan regulator with modular fan regulator step type 120 watts 2 module complete all as specified and directed. |
| 102 | M&L for replacement of existing old u/ssubmain wiring with two single core PVC insulated flexible copper conductor cable of size 4 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 4 Sqmm as earth lead in and including concealed PVC conduit and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed. |
| 103 | M&L for replacement of existing old u/ssubmain wiring with two single core PVC insulated flexible copper conductor cable of size 6 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 6 Sqmm as earth lead in and including concealed PVC conduit and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed. |
| 104 | M&L for replacement of existing old u/s tube light fitting with batten type18/20 watt energy efficient tube light fittings LEDcomplete with minimum 3.5 feet long with all accessories prewired and making connection with copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fittings complete all as specified and as directed. |
| 105 | S&F LED Bulk head light fitting 1 X 9/10 watts cool Daylight (CDL) round type premium quality diffuser for even distribution of light complete , connecting electrically to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete all as specified and directed. |
| 106 | M&L for replacement of existing old u/s tube light fitting with batten type10 watt energy efficient tube light fittings LEDcomplete with minimum 2 feet long with all accessories prewired and making connection with copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fittings complete all as specified and as directed. |
| 107 | M&L for replacement LED lamp 7 watt , 230 volts retrofit type complete all as specified and directed. |
| 108 | M&L for replacementLED lamp 15 watt , 230 volts retrofit type complete all as specified and directed. |
| 109 | M&L for replacementLED lamp 12 watt , 230 volts retrofit type complete all as specified and directed. |
| 110 | S&F in replacement sheet metal enclosure 4 way , with SPN DB\"s ( grouted in walls) double door type IP-43 Protection. Isolated Neutral, Door earthing, cement spill protector, IK-08 complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required complete all as specified and directed. |
| 111 | S&F in replacement sheet metal enclosure 8 way, with SPN DB\"s ( grouted in walls) double door type IP-43 Protection. Isolated Neutral, Door earthing, cement spill protector, IK-08 complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge |
| 112 | S&F in replacement sheet metal enclosure 12 way, with SPN DB\"s ( grouted in walls) double door type IP-43 Protection. Isolated Neutral, Door earthing, cement spill protector, IK-08 complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge |
| 113 | S&F in replacement of existing old u/s MCB SPN with MCB SPN , 240 volts, 32 amps, with rupturing capacity 10 KA, complete all as specified and directed. |
| 114 | S&F in replacement of existing old u/s MCB SPN with MCB SPN, 240 volts 40 amps, with rupturing capacity 10 KA, complete all as specified and directed. |
| 115 | S&F in replacement of existing old u/s MCB SPN with MCB SPN, 240 volts any rating from 63 amps, with rupturing capacity 10 KA, complete all as specified and directed. |
| 116 | S&F in replacement of existing old u/s MCB TPN with 63 amp MCB TPN, 415 volts breaking capacity 10 KA, complete all as specified and directed. |
| 117 | S&F in replacement of existing old u/s MCB TPN with 40 amp MCB TPN ,415 volts breaking capacity 10 KA, complete all as specified and directed. |
| 118 | S&F in replacement of existing old u/s MCB TPN with 32 amp MCB TPN, 415 volts breaking capacity 10 KA, complete all as specified and directed. |
| 119 | S&F in replacement existing unsv distribution board iron clad, with double door 4 way with IP-54,1K-09 protection,cemet spill protector suitablefor MCCB as incomer AC 415 Volts three pole with thermal release adjustable type (80% to 100 % ) and MCB as outgoing ,complete with appropriate size copper bus bar and neutral link complete with one MCCB 3 pole 415 Volts 100 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Outgoing MCB will be measured separately). |
| 120 | M&L for Replacement of unserviceable MCCB 100 Amps current carrying capacity 16 KA , AC 415 Volts three polecomplete all as specified and directed.including dismantling the existing with all connection and S&F the new with all connections complete all as specified and directed. |
| 121 | S&F in replacement MCB single pole 240 volts any rating 6 to 32 amps, with rupturing capacity 10 KA, complete all as specified and as directed. |
| 122 | S&F in replacement MCB single pole 240 volts any rating 40 amps, with rupturing capacity 10 KA, complete all as specified and as directed. |
| 123 | M&L for Replacement of unserviceable MCCB 100 Amps current carrying capacity 25 KA , AC 415 Volts three polecomplete all as specified and directed including dismantling the existing with all connection and making all new connections. |
| 124 | Repair, maint and making the continuity of supply after rectifying the defects of the electrical items such as switches, replacement of fuse wires, distribution boards, MCB (light/power), lamp holders (bracket/ pandents/ batten), bell/buzzer, push button, ceiling rose, capacitors, geyser, fans etc. and other similar electrical items/fittings etc. including provisioning of small pieces of electrical wire if required of size 1.5 sqmm to 2.5 sqmm single core and length not exceeding 0.50 mtrs complete all as specified and directed by Engineer-in-Charge.Note :- (i) any accessories found unserviceable that shall be paid as supply only under respective items of this Sch \"A\" . (ii) One job only will be considered for each bldg/Qtr per day irrespective of the Nos. of points made serviceable.(iii) The area for attending the complaints are Entire Mirthal Complex Area (iii) Each complaint attended/rectified shall be measured as one job. (iv) The contractor shall depute necessary man power on daily basis for rectifying the jobs including Sundays and holidays. (v) The contractor should deploy the manpower from the date of commencement of work. (vi)Fine for Rs 500 per day shall be charged to the contractor for not deploying of man power on any day. |
| 125 | S&F in repair of Hylum sheet 5x5 to 10 x 12 inches for fixing of switches, sockets etc. including cutting for fixing on existing or new sunken box with brass screw complete all as specified and directed. |
| 126 | S&F in repair ofpressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc. ) made of not less than 16 gauge MS sheet and 6cm depth of size 4x4 to 10 x 12 inches for fixing bakelite sheet of suitable size complete all as specified and directed. |
| 127 | Supply only FRLS PVC insulated fire retardant stranded copper conductor cable of 1.5 sqmm , cut to size all as required at site, complete all as specified and directed. |
| 128 | Supply only FRLS PVC insulated fire retardant stranded copper conductor cable of 2.5 sqmm , cut to size all as required at site, complete all as specified and directed. |
| 129 | Supply only FRLS PVC insulated fire retardant stranded copper conductor cable of 4.0 sqmm , cut to size all as required at site, complete all as specified and directed. |
| 130 | Supply only FRLS PVC insulated fire retardant stranded copper conductor cable of 6.0 sqmm , cut to size all as required at site, complete all as specified and directed. |
| 131 | Supplying and fixingin replacement of old u/sservice cable size 6 sqmm, twin core multistranded 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service with galvanised steel wire complete all as specified and directed. |
| 132 | All as per serial item No.131 here in above but for service cable of size 10 sqmm, complete all as specified and directed. |
| 133 | S&F in repair single phase change over 63 amp rating side handle operated complete all as specified and directed. |
| 134 | S&F in repair hanging holder suitable for B 22 base lamp complete all as specified and directed. |
| 135 | S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC fall ceiling type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for P.O.P fall ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 136 | S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 137 | S&F LED luminaire 300x300 mm maximum, 20 watt, 220 V AC fall ceiling type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for P.O.P fall ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 138 | S&F round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 139 | S&F Square shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 140 | S&F round shape 6 watt 220 volts AC fall ceilingtype with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for fall/P.O.P fall ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 141 | S&F round shape 12 watt 220 volts AC fall ceilingtype with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for fall/P.O.P fall ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 142 | Dismantling and taking out burnt/fault winding/ parts of voltage stabilizer single phase upto 4 KVA including repair/replacement of burnt/fault winding/ parts and refixing the same after repair complete all as specified and directed. |
| 143 | Disconnecting, dismantling and taking down carefully single pointed air terminationaluminium rod incl GI Pipe any size incl nuts & bolts and segregating U/s or serviceable parts incl removing from site or setting aside for reuse. |
| 144 | Disconnecting, dismantling and taking down carefully aluminium strip of any size up to 32 x 6 mm complete with saddles, GI tubing insulators and segregating U/s or serviceable parts incl removing from site or setting aside for reuse. |
| 145 | Fixing only aluminium strip retrieved from item No. 144 here-in-above. |
| 146 | Fixing only serviceable aluminium termination rod retrieved from item No. 143 here-in-above. |
| 147 | S&F in repair Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete with saddles and insulators made out of porcelain and fixing screws for roof conductor/down conductor including nut bolts& washers drilling and riveting for joints of suitable size as required at site all as specified and directed by Engr -in- Charge. Note :- Porcelain insulators are to be fixed at an interval of not more than 75 cm. |
| 148 | M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated location for loop earthing etc. with GI strip 32x6mm including dismantling old ones. |
| 149 | S&Fair termination single pointed aluminium rod 12mm dia and 300 mm long for fixing on GI pipemedium grade 20mm dia pipe duly making suitable fixing arrangement of one end of air termination rod all as specified and directed by Engr-in-charge. Note: GI pipe required will measured and paid separately. |
| 150 | M&L for plain Cement concrete 1:2:4 typeB-1, (Using 20 mm graded aggregate) as in foundation block for fixing GI pipe for installation of air termination rod etc. complete all as specified Note:- Unit rates includes for provn of form work for rough finished surfaces and finishing the exposed surfaces with 5 mm thick rendering in CM 1:3 all specified. |
| 151 | S&F GI pipe medium grade 20 mm dia for fixing Aluminium strip 25x3.15 mm on roof for lightening protection duly drilling 2 Nos holes on Aluminum strip and GI pipe on one end and fixing with screws/suitable size of bolts & nuts complete all as specified. Note: GI Strip required will measured and paid separately. |
| 152 | M&L earthing with steelearth plate electrode ofsize 60cmx60cmx6mm thick buried directly in ground to a depth not less than 2.25mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of GIand GI strip protected by provision of GI medium grade pipe 40mm bore, 20mm dia GI medium grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified orindicatedincludingtesting on completion.NOTE :- Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting totest point etc. all as required at site for complete earthing. |
| 153 | S&F in replacement of LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection eith die cast aluminium hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size. |
| 154 | S&F in replacement ofLED Building Streetlight 20 watt, IP 66, housing made of die-cast aluminium, with street optic lens, with all accessories and connecting up with and including provision of 3 core flexible copper wire of size 1.5sqmm from ceiling rose, and 20W LED light etc. drawn through and including 32mm bore GI light grade protection pipe upto 1.0m length with suitable fixing accessories on walls, complete all as specified and as directed. |
| 155 | S&F of flexible PVC pipe of 20 mm dia for protection of wire complete all as specified and directed. |
| 156 | S&F of flexible PVC pipe of 32 mm dia for protection of wire complete all as specified and directed. |
| 157 | S&F ofclamp for hanging of fan suitable for any size of pipe/arrangement of fan hook of ceiling/Recessed complete all as specified and directed. |
| 158 | S&F in replacement of copper thimbles size of 10 sqmm to 70 sqmm complete all as specified and directed. |
| 159 | M &Lforearthing complete with G .l earth plate electrode 60 cm x 60 cm x 6 mm thick burrieddirectlyinground(earth pit notless than 2.25 m deep below GL ) with top edge of the plate not less than 1.5 mbelow the normal groundlevelconnectedgalvanized earth lead wire 4.0 mm bymeansofbolts, nuts, check nuts and washers of galvanised ironorsteelincluding necessaryexcavation& earth work in any type of soil, removing surplus soil to a distance not exc 50 M,including PCC chamber in PCC (1 : 2 : 4), type B1, using (20 mm graded stone aggregate), mild steel frame madeout of angle iron of size 40 mm x 40 mm x 6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6 mm thick Cl coverwith handle , watering arrangement with funnel internally secured with wire mesh with 20 mm dia lightgrade GI pipe for watering, 15 mm dia mediumgrade,Gl pipe for earth wire protection with and including alternate layer of charcoal dust and common salt, complete all as shown in electrical plate No 3connectedto DBs all as specified and indicatedincluding testingon completion. |
| 160 | S&F in repair electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60 Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH, complete all as specified and directed. |
| 161 | Note: (i) In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.(ii) The Schedule of Credit amount shall be deducted from the total of this schedule (BoQ) to arrive at Contract Sum. |