Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-09-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 01-10-2024 |
| Sl. No. | Item Description |
| 1 | Taking down carefullyCopper/ aluminium point wiringlight, Fan, socket orpower completeincluding fixture & fitting such as switches, sockets or power socket complete fitting bracket holder, boards, and making good disturbed surfaces of wall and ceiling etc complete all as specified and directed. |
| 2 | Taking down carefully unserviceable sub main wiring/PVC cable including conduit/casing patti etc. complete all as specified and directed. |
| 3 | Taking down unserviceable DBs any type / size carefully disconnecting and making good disturbed surfaces complete all as all asspecified and directed. |
| 4 | Taking down unserviceable MCB SP/SPN/Isolator/MCCB/RCCBsof any rating & size complete all as specified and directed. |
| 5 | M &L for Point wiring complete with 1.5 Sqmm single core unsheathed PVC insulated 1100 V, FRLS grade with multistranded copper conductor ISI marked drawn through and including PVC casing & capping fixed on surface wall/ceiling and including modular cover plates and modular flush boxes for mounting of switches, sockets regulators etc including 1.5 Sqmm PVC insulted unsheathed cable multistranded with copper conductor and connecting to earth dolly for light, fan, plug and bell and making goodthe distributed surfacess completely matched and finished with existing surfacess complete all as specified and directed.(a)One light point controlled by one way switch. |
| 6 | (b)One light point controlled by two way switch |
| 7 | (c)One ceiling Fan, Exhaust Fan point controlled by one way switch. |
| 8 | (d ) One bell/buzzer point controlled by one bell push button on independent board. |
| 9 | (e)One 3 Pin 6 Amps socket point on the independent board. |
| 10 | (f)One 3 pin 6 Amp socket point on the same board with other switch. |
| 11 | All as perabove item No 5.00but with 2.5 Sqmm cable for 15 Amp switch socket out let point on independent board including 2.5 Sqmm PVC insulated unsheathed cable multistranded with copper conductor earthing continuity conductor complete all asspecified and directed. |
| 12 | Cutting chases, pinning in making good to facing where required and pointing in cement motar 1:3 to end or edges of landings, steps, cills, sunshades, shelves, lintels, etc.and cutting hases for concealed water tubing or concealed water tubing or concealed conduit wiring,etc.and making good cutting exceeding 10cm girth complete all asspecified and directed. |
| 13 | M &L for Point wiring complete with 1.5 Sqmm single core unsheathed PVC insulated, FRLS grade with multistranded copper conductor ISI marked drawn through PVC Conduit recess/surface fixed modular cover plates and modular flush boxes for mounting of switches, sockets regulators etc including 1.5 Sqmm PVC insulted unsheathed cable multistranded with copper conductor and connecting to earth dolly for light, fan, plug and bell and making goodthe distributed surfacess completely matched and finished with existing surfacess all as directed and specified by Engr-in-charge.(a)One light point controlled by one 6 Amps one way switch |
| 14 | (b)One ceiling Fan, Exhaust Fan point controlled by one 6 Amps switch. |
| 15 | (c ) One bell/buzzer point controlled by one bell push button on independent. |
| 16 | (d)One light point controlled by 2 Nos, Two way switch. |
| 17 | (e)One 3 pin socket out let 6 Amp point on independent board |
| 18 | (f)One 3 Pin socket out let 6 Amp point on the same board with other switch. |
| 19 | All as perabove item No 8.00but with 2.5 Sqmm cable for 16 Amp switch socket out let point on independent board including 2.5 Sqmm PVC insulated unsheathed cable multistranded with copper conductor earthing continuity conductor complete all as specified and directed. |
| 20 | Supply and fixing switch piano flushtype , single pole one way 5 Amps complete all as specified and directed. |
| 21 | Supply and fixing switch piano flush type , single pole two way 5 Amps complete all asspecified and directed. |
| 22 | Supply and fixing Bell push flush type SP 5 Amps complete all asspecified and directed. |
| 23 | Supply and fixing switch socketcombination out let 5 pin 6 Amps flush type complete all asspecified and directed. |
| 24 | Supply and fixing switch socket combination 2 in 1, 5 and 16 Amps flush type complete all asspecified and directed. |
| 25 | Supply and fixing modularswitch 6 Amps complete all asspecified and directed. |
| 26 | Supply and fixing modularswitch 6 Amps 2 way complete all asspecified and directed. |
| 27 | Supply and fixing modularswitch 16 Amps complete all asspecified and directed. |
| 28 | Supply and fixing Bell pushmodular type SP 6 Amps complete all asspecified and directed. |
| 29 | Supply and fixing socketcombination out let 2/3 pin 6 Amps modular type complete all asspecified and directed. |
| 30 | Supply and fixing switch socket out let 2 / 3 pin 6 and 16 Amps 2 modular type complete all asspecified and directed. |
| 31 | Supply and fixing ceiling rose, 3 phase, PVC polycarbonate, insulated body complete all asspecified and directed. |
| 32 | Supply and fix in replacement fan regulator electronic 2 modular type volts AC 50 HZ ,100 Watts,4 step complete all as specified and directed. |
| 33 | Supply and fix in replacement call bell (Ding Dong) 240 V, 50 Hz complete all asspecified and directed. |
| 34 | M&L for lamp holder pendant/angle type insulated body with back plate complete all asspecified and directed. |
| 35 | Supply and fixing in replacement of existing unserviceable T/L fitting 36/40 W on existing wall with new 18/20 Watts LED plastic Batten (white / warm white as directed) with acrylic cover sleek design & high efficency for wall and surface mounted applicaiton with necessary braket, clamps incl. bolts, nuts & washers for fixing arrangement etc complete all as specifed and directed . |
| 36 | S & Fix in replacement CRCA housing box type batten suitable for single LED Tubelight with integral LED driver, available in singleconnection CRCA batten suitable for mount LED tube rod 1 x 18/20 watts including necessary electric connections 3 core 1 sqmm insulated copper wire from ceiling rose to tube light fitting complete all as specifed and directed by Engineer-in-charge. |
| 37 | Supply and fix in replacementLED Rod tube light 18/20 watts (white / warm white as directed)with necessary fixing arrangement etc complete all as specifed and directed. |
| 38 | Supply and fix in replacement of existing unserviceable T/L fitting 20 W/Lamp holder on existing wall with LED light fitting 10 watts with LED tube rod (white / warm white as directed), ready to use pack with necessary braket, clamps, incl. bolts, nuts & washers for fixing arrangement etc complete all as specifed and directed. |
| 39 | Supply & fix in replacement of surface mounting round downlight LED 12 watt luminarie (white / warm white as directed) complete fittingwith all fixing arrangementcomplete all asspecified and directed. |
| 40 | Supply & Fix in replacement of LED Photo Light 6 Watts luninarie (white / warm white as directed) complete fittings with all fixing arrangements complete all asspecified and directed. |
| 41 | Supply and Fix in replacement of LED Track Light 15 Watts luminarie (white / warm white as directed) complete fitting with all fixing arragements complete all asspecified and directed. |
| 42 | Supply and Fix in replacement of LED Track Light Accessories (1Mtr - Track) complete inlcuding fixing arrangment all as directed. |
| 43 | Supply & Fix in replacement of LED down Light 8 Watts (white / warm white as directed) Adjustable type, energy saving, aesthetically designed, reccesed mounted type complete fitting with all fixing arrangement all as directed. |
| 44 | S&Fix in replacement LED wall mountingLight fitting, 9 watt, 230 volts, complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and suitable capacity of LED Bulb complete all asspecified and directed. |
| 45 | S&Fix in replacement LED Decorative wall Light fitting,9 watt, 230 volts, complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and suitable capacity of LED Bulb complete all asspecified and directed. |
| 46 | S & Fix in replacement of recess mounted 2\" x 2\" square LED panel 36 watts,Ultra modern recess mounting luminaire with high performance LEDs, suitable for mounting with Armstrong/Grid ceiling complete all asspecified and directed. |
| 47 | S & Fix in replacement 30 Watts LED new generation energy saving and environmental friendly long life LED building light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08 along with GI bend of suitable size complete all asspecified and directed. |
| 48 | S&F of in replacement LED bulkhead Lights designed to complement the geometry of the area with modern design. complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all asspecified and directed. |
| 49 | Supply and fix modular White cover plate with frame, 1 module complete all asspecified and directed. |
| 50 | Supply and fix modular white cover plate with framebut 2 module complete all as specified and directed. |
| 51 | Supply and fix modular white cover plate with framebut 3 module complete all asspecified and directed. |
| 52 | Supply and fix modular white cover plate with framebut 4 module complete all asspecified and directed. |
| 53 | Supply and fix modular white cover plate with framebut 6 module complete all asspecified and directed. |
| 54 | Supply and fix modular white cover plate with framebut 8 module complete all asspecified and directed. |
| 55 | Supply and fixing of capping casing of size 3/4\" of complete all asspecified and directed. |
| 56 | M&L for submain wiring alongwith earth wire with the following sizes of FRLSPVC insulatedcopper conductor single core cable , multistrandedon the surface recess through and including suitable size ofPVC casing and capping/PVC conduitwith its accessories all as specified and directedfor the following:-(a) 2x1.5 sq mm and 1x1.5 sq mm as earth wire |
| 57 | (b) 2x2.5 sq mm and 1x2.5 sq mm as earth wire |
| 58 | (c) 2x4.0 sq mm and 1x4 sq mm as earth wire |
| 59 | (d) 2x6.0 sq mm and 1x6 sq mm as earth wire |
| 60 | Supply & fix MCCB DB VTPN 4 ways, with metal double door, IP -43 protection suitable for MCCB as incommer and MCB as out going, 415 volt 3 phase complete with appropriate size copper bus bar and neutral link including cutting chases to wall for fixing of DB and making good distrubed wall/surface all as required at site i.e complete all asspecified and directed. |
| 61 | Supply & fix MCCB DB VTPN 6 ways, with metal double door, IP-43 protection suitable for MCCB as incommer and MCB as out going, 415 volt 3 phase complete with appropriate size copper bus bar and neutral link confirmingincluding cutting chases to wall for fixing of DB and making good distrubed wall/surface all as required at site i.e all asspecified and directed. |
| 62 | Supply & fix MCCB DB VTPN 8 ways,with metal double door ,IP -43 protection suitable for MCCB as incommer and MCB as out going, 415 volt 3 phase complete with appropriate size copper bus bar and neutral link confirmingincluding cutting chases to wall for fixing of DB and making good distrubed wall/surface all as required at site i.e complete all asspecified and directed. |
| 63 | Supply & fix MCCB DB VTPN 12 ways,with metal double door ,IP -43 protection suitable for MCCB as incommer and MCB as out going, 415 volt 3 phase complete with appropriate size copper bus bar and neutral link confirmingincluding cutting chases to wall for fixing of DB and making good distrubed wall/surface all as required at site i.e complete all asspecified and directed. |
| 64 | S & F sheet metal enclosuresDB\"s 2 waySPNsingledoor suitable for 240 Vcompletefixed flush in wall including chases in wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all asspecified and directed. |
| 65 | Supply & fix sheet metal enclosure MCB distribution board. Single pole & neutral (SPN) 240 volts 4 way with IP-43 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. |
| 66 | Supply & fix sheet metal enclosure MCB distribution board. Single pole & neutral (SPN) 240 volts 8 way with IP-43protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification all asspecified and directed. |
| 67 | Supply & fix sheet metal enclosure MCB distribution board. Single pole & neutral (SPN) 240 volts 12 way with IP-43 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. |
| 68 | S & F MCB single pole (SP) 240 volt 06-40 amp for inductive loadconnected through cable lugs of suitable size complete all as directed and specified. |
| 69 | S & F MCB single pole and neutral (SPN) 240 volt 06-40 amp for inductive loadconnected through cable lugs of suitable size complete all as directed and specified. |
| 70 | S & F MCB single pole and neutral (SPN) 240 volt 40 -100 amp for inductive loadconnected through cable lugs of suitable size complete all as directed and specified. |
| 71 | S & F MCB Tripplepole (TP) 415 volt 25-63 amp for inductive loadconnected through cable lugs of suitable size ccomplete all asspecified and directed. |
| 72 | S & F MCB Tripplepole and Neutral (TPN) 415 volt 16 to 32 Amp for inductive loadconnected through cable lugs of suitable size complete all as directed and specified. |
| 73 | S & FixMCB Triple pole and Neutral (TPN) 415 volts, 40 to 100 Amps, complete all asspecified and directed. |
| 74 | M & L for galvanised steel earthing complete with 60 cm x 60 cm x 6 mm thick galvanised steel earth electrode and 04 mmdia galvanised earth lead wire burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to earth lead 4.0 mm dia GI wire protected by 15 mm bore light grade galvanised iron pipe and other and connected to test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron wire mesh, charcoal and common salt in alternater of 15 cm complete thickness all around the GI plate electrode complete with earth pit PCC 1:3:6 type CI and RCC 1:2:4 type B1as in cover 50 mm twice with & including reinforcement with 8mm dia TMT bar at 75 mm spacing both ways andnecesary excavation and earth work in hard/dense soil and disposal of spoilto a distance not exc 50 mtr and necessary testing complete all as shown in electorical plate No 03 connected to earthing test point including taking out old U/S earthing material. |
| 75 | Supply and Fix in replacement 8 W Bollard LED light New generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape luminaire for diffused lighting with high power LED as light source. |
| 76 | Supply and Fix in replacement 25 watts Gate light fitting New generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source |
| 77 | Supply & fix in replacement 5 Watts LED Environmental friendly, compact, light weight, energy saving, IP66 LED spike light using COB LED as light source complete all asspecified and directed. |
| 78 | Supply and fix replacement of LED drivers of 36/43 watts capacity for 2x2 LED light fittings complete all asspecified and directed. |
| 79 | Supply and fix replacement of LED drivers of 8 to 12 watts capacity for LED lights complete all asspecified and directed. |
| 80 | Supply and Fix in replacement of 8 Watt 4 way wall light LED light including drilling, fixing and installing on the exisiting wall all as specified and directed by Engr-in-Charge. |
| 81 | Taking down carefully after disconnecting electrical/water supply connections and transporting to the work shop for carry out the servicing / over hauling of the storage type electric water heaters (Geysers) of storage capacity 25 / 50 litres of any make / type by cleaing the inner surface of the tank / heating element with chemical to remove the scaling / rust & reassembling the same after replacing burnt out parts and refixing on its original position including testing complete all as specifed and directed . |
| 82 | Supply & fix replacement heating element of 1.5/2 KW (Type of element as directed) ratings as required at site including rubber washer/packing (ISI marked) complete all asspecified and directed. |
| 83 | Supply &fix replacementthermostat stem type with autocut suitable for geysers 25 / 50 litres ISI marked complete all asspecified and directed. |
| 84 | Supply &fix replacement 15 mm Heavy duty connecting pipe with two brass adaptors 18 \" long &fixing in position fir cold & Hot water/inlet connection complete all asspecified and directed. |
| 85 | Supply &fix replacement 15 mm Heavy duty connecting pipe with two brass adaptors 24 \" long &fixing in position fir cold & Hot water/inlet connection complete all asspecified and directed. |
| 86 | Supply & fix in replacement Non-Return valve 15mm dia complete all as specified and directed. |
| 87 | Supply &fix replacement indicator lamp rectangular / round type suitable for 25 / 50 litres geysers complete all asspecified and directed. |
| 88 | Supply and fix in repair pressure release valve 15mm dia complete all as specified and directed. |
| 89 | Supply and fix in replacement bottom assemly of geyser any size complete all asspecified and directed. |
| 90 | Material & labour for painting of storage type water heater any capacity (25/50 litres) after preparation of surface and applying two coats of synthetic enamel paint, white externally complete all asspecified and directed. |
| 91 | Taking down the defective ceiling fan of any sweep andmake after disconnecting electrically & mechanically and transporting to the work shop dismantling, examine & carry out the servicing/overhauling the ceiling fan by thoroughly cleaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing and brought back to site, re-fixing, testing in all respect for smooth running complete all asspecified and directed. |
| 92 | Taking down the defective ceiling fan of any sweep andmake after disconnecting electrically & mechanically and transporting to the work shop dismantling, examine & carry out re-winding the burnt/short circuited winding with same guage supper enameled copper wire to maintain speed at load and brought back to site, re-fixing, testing in all respect for smooth running complete all as specified and directed. |
| 93 | Taking down the ceiling fan, single pahse, 230 Volts, 50 Hz, AC after disconnecting electrically on site and carry out painting of ceiling fan by applying one coats of synthetic enamel paint after preparation of surface complete all asspecified and directed. |
| 94 | Taking down the repairable exhaust fan of 300 MM / 380 MM sweep, any make, single phase, 230 volts, 50 hz, AC after disconnecting electrically and mechanically and transporting to the work shop dismantling, examine & carry out the servicing/overhauling the exhuast fan by thoroughly clelaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing including applying one coat of super enameled varnish over the winding to improve the resistance value and brought back to site, re-fixing, testing in all respect for smooth running complete all asspecified and directed. |
| 95 | Taking down the repairable exhaust fan of 300 MM / 380 MM sweep, any make, single phase, 230 volts, 50 hz, AC after disconnecting electrically and mechanically and transporting to the work shop dismantling, examine & carry out the Re-winding the burnt/shourt circuited winding with same cauge supper enameled copper wire to maintain speed at load complete all asspecified and directed. |
| 96 | Taking down the repairable exhaust fan of 300 MM / 380 MM sweep, any make, single phase, 230 volts, 50 hz, AC after disconnecting electrically on site and carry out painting of Exhaust fan by applying one coat of synthetic enamel paint after preparation of surface complete all asspecified and directed. |
| 97 | Supply & replace ball bearings for exhaust/ceiling fan of any sweep complete all asspecified and directed. |
| 98 | Supply & replace GUN METAL BUSH for exhaust / ceiling fan of any sweep complete all asspecified and directed. |
| 99 | Supply and fix in repairs fan condenser of following sizes :-(a) 2.5 mfd |
| 100 | (b) 4 to 6 mfd |
| 101 | Supply & Fixin replacementceiling fan down rod of MS pipe 15mm bore 1/1.2 Mtr length including cutting/threading making tide for fixing providing check nuts wachers etc complete all asspecified and directed. |
| 102 | S & Fix in replacement PVC Body Exhaust fan AC single phase 220 to 240 volts 900 RPM of size 200 mm sweep with fixed on wall/ventilator and fixing arrangement complete all as specified & directed. |
| 103 | S & Fix in replacement PVC Body Exhaust fan AC single phase 220 to 240 volts 900 RPM of size 250 mm sweep with fixed on wall/ventilator andfixing arrangement complete all as specified & directed. |
| 104 | S & Fix in replacement Metal Body Exhaust fan AC single phase 220 to 240 volts 1400 RPM of size 225/230 mm sweep with fixed on wall/ventilator andfixing arrangement complete all as specified & directed. |
| 105 | S & Fix in replacement Metal Body Exhaust fan AC single phase 220 to 240 volts 1400 RPM of size 300 mm sweep with fixed on wall/ventilator andfixing arrangement complete all as specified & directed. |
| 106 | Material and Labour for fixing of wooden frame with GI wire mesh of size 300 x 300 mm with wooden section 40 x 25 mm with necessary fixture and all fixing arrangementall as directed and specified. |
| 107 | Supply and fix in replacement ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Five star rated with brushless direct current motor (BLDC) including all connections and all as specified & directed. |
| 108 | Supply and fixin replacement of ceiling fan blade set (03 Nos), 1200 mm sweep (colour as directed), including all fitting arrangements all as directed and specified. |
| 109 | Supply and fix in replacement LED bulb /lamp 9W all asspecified and directed |
| 110 | Supply & fix 3 core 1.5 sqmm PVC insulated Sheathed multicore copper flexible cable connected with existing point all asspecified and directed. |
| 111 | Supply & fix 2 core 6 sqmm PVC insulated Sheathed alluminiumn flexible cable connected with existing point all asspecified and directed. |
| 112 | Supply & fix in replacement of AC plug Top 20 Amps for ACs complete all asspecified and directed. |
| 113 | Supply only Fix in replacement PVC Box of size 4.5\" x 3\" suitable for 15 amp switch-socket complete all asspecified and directed. |
| 114 | Supply and fix 3 mm thick laminated sheet ISI mark cover fixed with brass screws and cup washers for mounting of plate mounting forhousing the switches, socket outlets, fan regulators etc complete all asspecified and directed. |
| 115 | Supply and fix Double pole 30 mA RCCBs 25A for earth leakage protection complete all asspecified and directed. |
| 116 | Supply and fix Double pole 30 mA RCCBs 40A for earth leakage protection complete all asspecified and directed. |
| 117 | Taking out carefully existing defective sealed compressor of Split type AC 1.5/2 ton capacity by dismantling the same, supply and fixing new sealed compressor as per existing model and make including bracing, leak testing, vacuuming charging the oil, refrigerant as required to maintain design grill temperature, testing and commissioning in all respect all as specified and directed by Engineer-in-Charge. |
| 118 | All as per item No 103 above but for Window Type AC 1.5/2 Ton capacity complete all asspecified and directed. |
| 119 | All as per item No 103 above but for storage type water cooler of 40 liters capacity complete all asspecified and directed. |
| 120 | All as per item No 103 above but for storage type water cooler of 60 to 150 liters capacity complete all asspecified and directed. |
| 121 | Supply and fixing of water heater of capacity 25 ltrs 5 Star rated inculding all fixture and fittings complete all asspecified and directed. |
| 122 | M&L for tak in replacement down the existing defective fan/ blower motor and transporting to the work shop and dismantled burnt motor, removing the burnt winding & rewinding with super enameled copper wire of suitable size and gauge & replacement of unserviceable bearing of motor of following :-(a) Fan motor (two speed i.e low & high) for window type AC. |
| 123 | (b) Condenser fan motor for water cooler. |
| 124 | (c) Condenser fan motor for split type AC (condensing unit /out door unit) |
| 125 | (d) Blower fan motorfor split type AC unit (indoor/cooling unit) |
| 126 | Supply in repairs capacitors of following capacity:-(a) Capacitors 80-100/120 Mfd |
| 127 | (b) Capacitor 45-65 Mfd |
| 128 | (c) Capacitors 10-25 Mfd |
| 129 | Disconnecting and taking out the defective split type AC 1.5/2.0 ton capacity remote circuit complete and supplying and fixing new remote circuit (PCB) as per existing make/model complete all as specified and directed by Engineer-in-Charge. |
| 130 | Supply & Fix in replacement of Single Phase Voltage stabilizer 4 KVA capacity, Voltage range 170V - 270 V for Split Type / Window Type ACs / Water Cooler including all fixing arrangements all as specified and directed. |
| 131 | Removing the damaged PUF insulation of suction pipe and supplying and fixing new thermal sleeve insulation for suction line including providing hard plastic tape over the thermal insulation for split type AC 1.5/2.0 ton capacity etc complete all as directed by Engineer-in-Charge. |
| 132 | Supply and fix in replacement overload protectors relays for the following:-(a) Water cooler |
| 133 | (b)Window type AC |
| 134 | (c) Split type AC |
| 135 | Taking out defective fan blade and supplying and fixing new blades for water cooler of 40/80/100 liters capacity complete all as directed by Engineer-in-Charge. |
| 136 | Taking out defective push cock and supplying and fixing new push cock chromium plated brass, 15 mm bore of approved make for water cooler complete all as directed by Engineer-in-charge. |
| 137 | Taking out old PVC conduit condensation water pipe20mmdia from indoor unit to ground floor by using new PVC conduit ISI mark condensation water pipe 20mm dia, fixing/laying on wall by using clamps and insert into wall by making hole and grouting with cement mortar complete all as specified and as directed by Engineer-in-Charge. |
| 138 | Supply and fix in replacementSingle pole and nuetral enclouser with two pin and earthplug and socket complete with one single pole MCB with 240 V 20 AMPs. |
| 139 | Taking down Split type AC of any capacity / make/ model from existing position and carry out the servicing by cleaning the unit with water, tightening the terminal connections to avoid loose connections, applying the oiling/greasing to fan motor, bearings all as specified for smooth running including cleaning the air filter/check the thermometer setting etc for 1.5-2.0 ton. and directed by Engineer in charge. |
| 140 | Taking down window type AC of any capacity / make/ model from existing position and carry out the servicing by cleaning the unit with water, tightening the terminal connections to avoid loose connections, applying the oiling/greasing to fan motor, bearings all as specified for smooth running including cleaning the air filter/check the thermometer setting etc for 1.5-2.0 ton. and directed by Engineer in charge. |
| 141 | Taking down from existing position storage type water cooler of any capacity and make and servicing the same by cleaning of water tank, cleaning condensing unit by hand blower and including supply and replacement of damaged aluminium hinges, wiring with PVC insulated copper wire of same gauge, PVC drainpipe 25 mm dia, 1.5 m length, servicing/oiling/greasing of condenser motor with supply and replacement of mounting rubber bushes, tightening of all loose parts, contacts, wiring, nuts, bolts,complete including re-fixing in original position, testing and commissioning to the entire satisfaction of Engineer-in-Charge. |
| 142 | Supply and fix in replacement of air filter pad for Split Type AC of any 1.5 / 2 TR complete all asspecified and directed. |
| 143 | Supply and fix in replacement of outer casing for Split Type AC 1.5 TR / 2 TR complete all asspecified and directed. |
| 144 | Supply and fix in replacement of flaps for Split Type AC indoor Unit ofsuitable size/ shape / modelas required at site. |
| 145 | Supply and fix in replacement of air filter pad for window type complete all as specified and directed. |
| 146 | Supply and fix in replacement of outer casing for window AC 1.5 TR complete all as specified and directed. |
| 147 | Supply and fix in replacement of front grill for window AC ofsuitable size/ shape / modelcomplete all as specified and directed. |
| 148 | Supply and fix in replacement of auto cut thermostat for window type AC / split type AC complete all as specified and directed. |
| 149 | Supply and fix in replacement of auto cut thermostat for water cooler complete all as specified and directed. |
| 150 | Supply and charging / topping up refrigerant R-22/ R-134to window type / split type AC as directed by Engineer-in-charge. |
| 151 | Supply and charging / topping up refrigerant R-134 / R-22 to water cooler as directed by Engineer in charge. |
| 152 | Supply and charging / topping up oil to window type / split type AC and Water cooler compressorsas directed by Engineer-in-charge. |
| 153 | Detecting of gas/refrigerant leakage in the system by pressure testing withnitrogen gas and rectifying the same by brazing if required replace the copper tube as required and vacuumising, recharging of refrigerant as recommended by manufacture to maintain the design grill temperature by testing & commissioning including changing of compressor oil for window type AC 1.5/2 TR capacity complete all as specified and directed by Engineer-in-Charge. |
| 154 | All as per item No 132.00 here in before but for split type A/C 1.5/2/3 TR capacity complete all as specified and directed. |
| 155 | All as per item No 132.00here in before but for water cooler any type/capacity complete all as specified and directed. |
| 156 | Supply and fix in replacement of 3 phase, 4 wire Energy meter including fixing and connection and deposit the old u/s meter to MES complete all as specified and directed. |
| 157 | Supply and fixing of iron angle (2 Nos) for fixing of outdoor unit of any capacity split AC including making hole/cutting/drill and masonry work all as specified and directed by Engr-in-Charge. |
| 158 | M&L for painting out door unit of 1.5/2.0/3.0 TR capacity split type A/C by one coat of spray painting using super enamel paint over one coat of anticorrosive primer including preparation old surfaces by scraping etc complete all as specified and directed by Engineer-in-Charge |
| 159 | Taking down the defective voltage stabilizer 5/4 KVA, carry out the repair by replacing the unserviceable parts & refixing the same including testing.(a)Volt meter (As per sample) |
| 160 | (b) Indication lamp |
| 161 | (c)PCB |
| 162 | (d) Transformer rewinding |
| 163 | Supply and fix in replacement of single phase, energy meter including fixing and connection and deposit the old u/s meter to MES complete all as specified and directed. |
| 164 | Cutting holes by cutting machine or other mean into or through cement or otherwise, brick / stone masonry walls etc. cutting wall thickness n.exc 20 inchs for purpose of AC work and electrical work and making good disturbed surfaces complete all as specified and directed. |
| 165 | Repair / servicing and overhauling to aqua guard of any type and capacity, cleaning paper carbon filter pipes etc including replacement of worn out parts like paper filter carbon, filter solenoid valve, water pump etc all as directed by Engr-in-Charge.Note : Spare parts replaced will be measured and paid separately under respective items. |
| 166 | (a) Micro carbon filter. |
| 167 | (b) Primary paper filter. |
| 168 | (c) Water solenoid valve. |
| 169 | (d) Outlet / Inlet pipes. |
| 170 | S&F copper tubing along with necessary insulation as per manufacture standerd for 1.5/2 TR split AC unit, copper tubing pipe 3/8\"for split type AC including provision of insulation on tubing or as directed by Engineer-in-Charge. |
| 171 | S&F copper tubing along with necessary insulation as per manufacture standerd for 1.5/2 TR split AC unit, copper tubing pipe5/8\" for split type AC including provision of insulation on tubing or as directed by Engineer-in-Charge. |
| 172 | S & Fix in replacement Metal Body Exhaust fan AC single phase 220 to 240 volts 1400 RPM of size 300 mm sweep with fixed on wall/ventilator andfixing arrangement complete all as specified & directed & depositing old U/s fan to MES. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy