Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 20-09-2024 | AMDT2 | Date | 05-10-2024 |
| 2 | 14-09-2024 | AMDT1 | Date | 01-10-2024 |
| Sl. No. | Item Description |
| 1 | Taking down defective LED street light or Flood light or High mask light or Post top lantern LED Light of any capacity viz 10W/20W/25W/30W/60/W/ 200W,fitting of any type from their existing position i.e. poles or bldg or pillers or gardens and re-fixing the same after carried out repairs i.e. replacement of LED driver,SPD , PVC wire and any other necessary connecting item and making suitable for lightning purpose, all as specified and directed by Engineer-in-Charge. Note : (i) LED driver, and SPD , 3 core cable will be measured and paid separately under respective items .(ii) Cost of nut, bolts & washers for fixing new items is deemed to be included in quoted rate. |
| 2 | Supply only surge protection device (SPD) of capacity 10 KV with phase, neutral and earth wire in incoming and out going both sides suitable for120/ 200 Watt LED Flood Light fitting complete all as specified and directed by Engineer-in-Charge.Make : Bajaj / Havells/Crompton |
| 3 | Supply only surge protection device (SPD) of capacity 8 KV with phase, neutral and earth wire in incoming and out going both sides suitable for 60 Watt LED Street Light fitting complete all as specified and directed by Engineer-in-Charge.Make : Bajaj / Havells/Crompton |
| 4 | Supply only surge protection device (SPD) of capacity 5 KV with phase, neutral and earth wire in incoming and out going both sides suitable for 25/30 Watt LED Light Street fitting complete all as specified and directed by Engineer-in-Charge.Make : Bajaj / Havells/Crompton |
| 5 | Supply only surge protection device (SPD) of capacity 4 KV with phase, neutral and earth wire in incoming and out going both sides suitable for 20 Watt LED Post top lantern Light fitting complete all as specified and directed by Engineer-in-Charge. Make : Bajaj / Havells/Crompton |
| 6 | Supply only surge protection device (SPD) of capacity 2 KV with phase, neutral and earth wire in incoming and out going both sides suitable for 10/15 Watt LED Bollard Light fitting complete all as specified and directed by Engineer-in-Charge.Make : Bajaj / Havells/Crompton |
| 7 | Supply only LED driver 25/30 W LED Street light fitting of type make/model as per sample complete all as specified and directed by Engineer-in-Charge. |
| 8 | Supply only LED driver 60 W LED Street light fitting of type make/model as per sample complete all as specified and directed by Engineer-in-Charge. |
| 9 | Supply only LED driver 120/200 W LED Street light fitting of type make/model as per sample complete all as specified and directed by Engineer-in-Charge. |
| 10 | Supply and fixing LED driver 18/20 W for LED post top lantern light fitting of type make/model as per sample complete all as specified and directed by Engineer-in-Charge. |
| 11 | Supply and fixing LED driver 10 W for LED bollard light fitting of type make/model as per sample complete all as specified and directed by Engineer-in-Charge. |
| 12 | Supply and fixing post top lantern LED type 25 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete. Make : Havells CAT PART NO. CORALPT25WLED757PSYMTOPC and equivalent make of Bajaj/Crompton |
| 13 | Supply and fixingLED Bollard Light(TULIP)/ Garden Lightwith optical acrylic diffuserof 9/10 watt , 5700 K and IP 66 ProtectionComplete all as specified and directed by Engineer -in-Charge. Make :Bajaj -CAT PART NO.BGBOM605 9 W LED WH,Crompton CAT PART NO - LBLSR-10-WW or equivalent in Havells |
| 14 | Supply and fixingLED Bollard Light (FLUTE) in cylindercal shapewith optical acrylic diffuserof 9/10 watt , 5700 K and IP 66 Protection for garden Complete all as specified and directed by Engineer -in-Charge. Make :Bajaj CAT PART NO.BGBOL605 9 W LED WH,Crompton CAT PART NO - LBLA1-10-CDLor equivalent in Havells |
| 15 | M&Lfor safely dismentling of existing high mast light 21 mtr longincludingflood lights, plinth area & complete operating mechanism, and safely shifting to other place within cantt area not more than 5 KM distance including transportation with necessary T&P .Re-assembling, errection, installationfixing and made functional complete in all repect including necessary foundation work all as specified & directed by Engr-In Charge. |
| 16 | Repair/ maint of High Mast including replacement of taking up and taking down mechanism including replacement of gear & pulley assembly for proper functing and greasing of high light fitting all as directed by Engineer in Charge. |
| 17 | Supply and fixing PVC insulated unarmoured multi strand copper conductor cable 1100 volts grade of size 2.5 Sqmm 10 core alongwith High Mast all as directed by Engineer in charge. |
| 18 | M&L for street light bracket made to shape from GI Pipe medium grade 25 mm dia of length 2.5 m including two number of clamps made pf 50X6 flat iron nut bolts complete all as specified |
| 19 | M&L for street light bracket made to shape from GI Pipe medium grade 40 mm dia of length 2.5 m including two number of clamps made of 50X6 flat iron nut bolts complete all as specified |
| 20 | Supply and fix in replacement of PVC pipe 15 mm bore light grade for protection of cable from street light fitting to junction box including provision of two NosMS clamps made out of 50 x 6 mm MS Strip withnuts,bolts etc required for fixing pipe along pole complete all as specified and directed. |
| 21 | Supply and fix in replacement Hot moulded (FRP) junction box of size 280mm x 200mm for street light pole with locking arrangementwith 32 Amps, 4 way heavy duty terminal block suitable connection for three phase incoming cable three phase outgoing cable and single phase connection for light fittings with control MCB SP 10 Amps 01 Nos enclosed in thermoplastic box in closed shock proof safe IP 65, weather, vermin proof, dust and water proof complete with two number cable entryglandof standard size with suitable size mild steel clamps to fix on pole complete all as specified and directed by Engineer-in-Charge.Make: Neptune/ Hensel/ Sintex or equivalent as approved by GE |
| 22 | Supply & fixing in replacement ofLED Flood light fitting of 120 Watt IP 66 made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lensesSystem efficacy >110/120 LPW,with10 KV SPD Complete all as specified and directed by Engineer-in-Charge.MAKE :Crompton catpart No -TFS-504-120-57-60D-SL-GL-NSG or equivalent in Bajaj/Philips |
| 23 | Supply & fixing in replacement ofLED of 60 Watt IP 66Street lights fittings aerodynamically designed for all weather conditions with excellent thermal management, made up of pressure die cast housing with toughened glass and high power LED\"s with secondary andIP66 protection. 10 KV SPD included,Efficacy ≥110/120 LPW complete all as specified and directed by Engineer-in-Charge. MAKE - Crompton cat part no-CRP-409-60-57-SL-GL-NSG or equivalent in Bajaj/Philips |
| 24 | Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth for foundations of poles, struts, stays etc. or layingunderground cable etc.in soft/loose soil,& getting out complete all as specified and directed by Engineer-in-Charge. |
| 25 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge |
| 26 | M & L for sand cushioning with dry coarse sand to under ground cable 23 cmthick, 8 cm thick below the cable and 15 cm thick after laying the cable complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment. |
| 27 | M & L for brick protection with old size sub class \"B\" bricks laid flat , length of bricks across the route of underground cable all as specified and directed by Engineer-in-Charge. |
| 28 | M & L for boring hole across the Road/plinth/hard standing by trench less technology method suitable for 100mm bore pipe for 0.4 mpa working pressure for cable passing without damaging Road / Plinth /Floor complete all as specified and directed. |
| 29 | Disconnecting and taking out old unserviceable underground LT Cable of 2/3.5/4 core, 10 sqmm upto 240 Sqmm from trenches/ floor/ road /pipe /along poles including taking out old bricks complete all as specified and directed by Engineer-in-Charge. Note :Excavation, earth workrequired for item shall be measured and paid separately under respective items of BOQ. |
| 30 | Relaying of LT cable from 10 sqmm to 400 sqmm 2/3.5/4 core in same or other trenches/wall surfaces/flooring/road and testing on completion including good all disturbed surfaces to match with existing complete all as specified and directed. Note : Earth work viz excavation, sand cushioning will be measured and paid seprately. |
| 31 | Supply, laying in trenches or fixing to wall/pole or passing through pipe and and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 Sqmm 2 Core including making good to all disturbed surfaces/flooring/tiling/road to match with existing specifications complete all as specified and directed.Make:- HAVELLS/KEI/POLYCAB |
| 32 | All as per Srl item No 31 here-in-before but cable of cross sectional area 6 Sqmm, 4 core complete all as specified and directed by Engineer-in-Charge.Make:-HAVELLS/KEI/POLYCAB |
| 33 | All as per Srl item No 31 here-in-before but cable of cross sectional area 10 Sqmm, 4 core complete all as specified and directed by Engineer-in-Charge.Make:-HAVELLS/KEI/POLYCAB |
| 34 | All as per Srl item No 31 here-in-before but cable of cross sectional area 16 Sqmm, 4 core complete all as specified and directed by Engineer-in-Charge.Make:-HAVELLS/KEI/POLYCAB |
| 35 | All as per Srl item No. 31 here-in-before but cable of cross sectional area 25 Sqmm, 4 core complete all as specified and directed by Engineer-in-Charge.Make:-HAVELLS/KEI/POLYCAB |
| 36 | All as per Srl item No. 31 here-in-before but cable of cross sectional area 35 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge.Make:-HAVELLS/KEI/POLYCAB |
| 37 | All as per Srl item No.31 here-in-before but cable of cross sectional area 50 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge.Make:-HAVELLS/KEI/POLYCAB |
| 38 | All as per Srl item No.31here-in-before but cable of cross sectional area 70 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge.Make:-HAVELLS/KEI/POLYCAB |
| 39 | All as per Srl item No.31here-in-before but cable of cross sectional area 95 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge.Make:-HAVELLS/KEI/POLYCAB |
| 40 | All as per Srl item No.31here-in-before but cable of cross sectional area 120 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge.Make:-HAVELLS/KEI/POLYCAB |
| 41 | All as per Srl item No.31here-in-before but cable of cross sectional area 150 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge.Make:-HAVELLS/KEI/POLYCAB |
| 42 | All as per Srl item No.31here-in-before but cable of cross sectional area 240 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge.Make:-HAVELLS/KEI/POLYCAB |
| 43 | Supplyand fix in replacement ofMCCB 4 pole 63A , 415 V, 50Hz having breaking capacity 16 KA with adjustable thermal & magnetic setting complete all as spd and directed by Engg.in.Charge.Make: ABB/L&T/Schneider |
| 44 | Supplyand fix in replacement of MCCB 4 pole 100 A , 415 V, 50Hz having breaking capacity 25 KA with adjustable thermal & magnetic setting complete all as spd and directed by Engg.in.Charge Make: ABB/L&T/Schneider |
| 45 | Supplyand fix in replacement of MCCB 4 pole 160 A , 415 V, 50Hz having breaking capacity 35 KA with adjustable thermal & magnetic setting complete all as spd and directed by Engg.in.ChargeMake: ABB/L&T/Schneider |
| 46 | Supplyand fix in replacement ofMCCB 4 pole 200 A , 415 V, 50Hz having breaking capacity 35 KA with adjustable thermal & magnetic setting complete all as spd and directed by Engg.in.Charge.Make: ABB/L&T/Schneider |
| 47 | Supplyand fix in replacement ofMCCB 4 pole 250 A , 415 V, 50Hz having breaking capacity 35 KA with adjustable thermal & magnetic setting complete all as spd and directed by Engg.in.Charge.Make: ABB/L&T/Schneider |
| 48 | Supplyand fix in replacement of MCCB 3 pole 350 A , 415 V, 50Hz having breaking capacity 36 KA with adjustable thermal & magnetic setting complete all as spd and directed by Engg.in.Charge.Make: ABB/L&T/Schneider |
| 49 | Supplyand fix in replacement ofMCCB 3 pole 400 A , 415 V, 50Hz having breaking capacity 36 KA with adjustable thermal & magnetic setting complete all as spd and directed by Engg.in.Charge.Make: ABB/L&T/Schneider |
| 50 | Supply only MCCB 3 pole 630 A , 415 V, 50Hz having breaking capacity 50 KA with adjustable thermal & magnetic setting complete all as spd and directed by Engg.in.Charge.Make: ABB/L&T/Schneider |
| 51 | Supply only aluminium lugs suitable for cable of size 16 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 52 | Supply only aluminium lugs suitable for cable of size 25/35 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 53 | Supply only aluminium lugs suitable for cable of size 50/70 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 54 | Supply only aluminium lugs suitable for cable of size 95 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 55 | Supply only aluminium lugs suitable for cable of size 120 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 56 | Supply only aluminium lugs suitable for cable of size 150 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 57 | Supply only aluminium lugs suitable for cable of size 240 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 58 | Supply only aluminium lugs suitable for cable of size 300 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 59 | Supply only aluminium lugs suitable for cable of size 400 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 60 | Supply and fix Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed by Engr-In-Charge. |
| 61 | S&F cable jointing kit for 1100 V (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 35 sqmm to 50 sqmm complete all as specified.Make: M-Seal/Birla 3M/Denson. |
| 62 | S&F cable jointing kit for 1100 V (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 95 sqmm complete all as specified.Make: M-Seal/Birla 3M/Denson. |
| 63 | S&F cable jointing kit for 1100 V (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 sqmm to 150 sqmm complete all as specified.Make: M-Seal/Birla 3M/Denson. |
| 64 | S&F cable jointing kit for 1100 V (Earthed) grade cable for straight throughheat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 35 sqmm to 50 sqmm complete all as specified.Make: M-Seal/Birla 3M/Denson. |
| 65 | S&F cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 95 sqmm complete all as specified.Make:Denson,M-Seal/Birla 3M/CCI |
| 66 | S&F cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 sqmm to 300 sqmm complete all as specified.Make: M-Seal/Birla 3M/Denson. |
| 67 | S&F weather proof fibre board, fabricated of 3mm thick acrylic cover fibre duly printed line diagram of electirc supply printed/writing figure(letter/number) provided with 6 mm thick plywood , \"U\" shaped aluminium bedding all around board and fixed on wall with rawlplug and screws etc. complete all as specified and directed by Engr-in-Charge. |
| 68 | S&F First aid kit box including necessary first aid items viz bandages, gauze roll and pads, thermometer, scissors, tweezers,safety pins, elestic bandage, triangular bandage, liquid bitadine, pain killers, first aid manual, disposable sterile gloves, cotton, tourniquet, antiseptic, hydrogen peroxide complete all as specified. |
| 69 | S&F E&M installation related ready made charts of fire safety, DO & DON\"T, Electrical safety rules, How to do First aid etc complete all as per directed by Engr-in-Charge. |
| 70 | M&L for marking/writing feeder names/SM no./MES no. for HT/LT electrical equipments like VCB, transformers, LT Panels, HT/LT electric poles with synthetic enamel paint or water proof stickers complete all as specified and directed. |
| 71 | M&L for cutting, trimming of branches along 2 pole/4 pole structure , OH Conductor of LT/HT line within 2 mts distance along both sides of structure /line complete all as directed by Engr-in-Charge. |
| 72 | Removal of bushes/plants/shrubs around the water supply or electric supply installation or near LT Panels , inside valve pits and surface excavation not exceeding 15 cm depth levelling the ground, removing excavated material outside the army cantt area complete all as specified and directed by Engr-in-Charge. |
| 73 | M&L for preparationold painted surfaces with synthetic enemel paint to LT steel tubbular pole 8.5/9 mtr long including clamps,brackets,chanel,cross arms,bracing support pipe for cable and swan neck etc, including zebra painting at bottom up to 1.5 mtr above from the PCC couping and writing pole No with white paint complete etc complete all as specified and as directed by Engr-In-Charge .Note: Pole number shall be marked with white enamel paint over a base of size 20cmx20cm on prepared with two coats of black enamel paint on pole surfaces. |
| 74 | Supply and fixGI pipe 80 mm bore light grade for protection of cable including provision of MS clamps, nuts, bolts etcrequired for fixing pipe along pole / wall / laid under the road / laid under the floor or in trenches complete all as specified and directred by Engineer-in-Charge. |
| 75 | Supply and fix in replacement of GI pipe 50 mm bore light grade for protection of cable including provision of MS clamps, nut, bolts etcrequired for fixing pipe along pole / wall / laid under the road / laid under the floor or in trenches complete all as specified and directred by Engineer-in-Charge. Note: (i) Excavation & earth work shall be measured and paid separately under respectiveitem of this Schedule. |
| 76 | M & L for preparation ofold painted surfaces of LT panel size (up to 2.0x1.5mx0.8m) and applying spray painting with two coats of synethetic enamel paint over a coat of red oxide primer of existing color for outdoor/indoor panel board, outer & inner side and scraping out the old paint surfaces of existing panel boards including white wash to panel foundation/PCC basecomplete all as specified and directed by Engr-In-Charge . |
| 77 | Supply and fix in replacement of digital Ammeter 0 - 100 Amps |
| 78 | Supply and fix in replacement digital Voltmeter 0 - 500 Volts |
| 79 | Supply and fix in replacement neon indicating lamp (Red, Yellow, Blue) |
| 80 | Material and Labour MS work as in doors or gates or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering in doors or gates etc. to be prepared for hanging or sliding with and including hooks and hinges or steel hanging door fittings and hanging , fastening and fixing complete as in compound guards of transformers, four pole/two pole structures in sub stations or doors and gates of Panles or DB\"s incuding painting of two coats of enamel paint over one coat of zinc coatingprimer complete all as specified and directed. Note :- Disconnection of cables/wires, repair of broken doors/gates of panels and DB\"s by necessary welding with painting deemed to be included in rate quoted by contractor. |
| 81 | S&F GI strip 32x6 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground or fixed on structure fixed with screws and bend to any shape as required for site complete all as specified and directed by Engineer-in-charge. |
| 82 | Supply,installation, commissioning and testingof LT panel (Outdoor type ) board of size not less than 150cmx150cmx80cm made out of 3.15 mm thick CRCA sheet vermin proof, including painting with sysnthetic enamelled paint, CPRI approved with colour code PVC sleeves for bus bar, front opened with locking arrangement, closed bus bar chameber, angle iron frame of size 50x50x6mm for skeleton and support embeded in concrete foundation comprising of the following :- (MRS)(a) Copper bus bar 800 amps for phase & neutral-04 No (b) ACB 4 Pole ,415 volts, 630Amps, Thermal magnetic release - 01 Nos (In coming) (c) MCCB 4Pole 400 Amps, 35 KA - 01 Nos (O/G) (P-46)(d) MCCB 4P 250 Amps, 35 KA, Thermal magnetic release- 01 Nos (ADS)(e) MCCB 4P 200 Amps, 35 KA,Thermal magnetic release- 01 Nos (old signal)(f) MCCB 4 pole 160 Amp ,35 KA,Thermal magnetic release -01 No.(spare)(g) Voltmeter 0-500 volts range with selector switch digital type-01 Set (h)Ammeter 0-200 amps range with selector switch & CT coils - 01 Set(j)Indicator lamp with holder for RYB- 01 SetDesign/ drawing / BOM of the panel board showing the dimension incl accessories is to beobtained from panel board manufacturer / supplied an is to be got approved from GE before placing fianl order to the manufacturer / suppliers. 2. Anything missing out in the technical specification but technically required for efficient working is deemed to be included in qouted rates. |
| 83 | Supply,installation, commissioning in of LT panel (Outdoor type ) board of size not less than 150cmx150cmx80cm made out of 3.15 mm thick CRCA sheet vermin proof, including painting with sysnthetic enamelled paint, CPRI approved with colour code PVC sleeves for bus bar, front opened with locking arrangement, closed bus bar chameber, angle iron frame of size 50x50x6mm for skeleton and support embeded in concrete foundation comprising of the following :-(Near P-46)(a) Copper bus bar 600 amps for phase & neutral-04 No (b) MCCB 4Pole 350 Amps, 36 KA - 01 Nos (I/G)(c) MCCB 4Pole 200 Amps, 35 KA - 02 Nos (O/G) (P-76& adm block) (d) MCCB 4P 160 Amps, 35 KA - 02 Nos (P-46&P-45) (e) MCCB 4 pole 100 Amp ,25 KA-01 No.(2x cook house)(f) MCB TPN 32 Amp -01 Nos (for street light)(g) Voltmeter 0-500 volts range with selector switch digital type-01 Set (h)Ammeter 0-200 amps range with selector switch & CT coils - 01 Set(j)Indicator lamp with holder for RYB- 01 SetDesign/ drawing / BOM of the panel board showing the dimension incl accessories is to beobtained from panel board manufacturer / supplied an is to be got approved from GE before placing fianl order to the manufacturer / suppliers. 2. Anything missing out in the technical specification but technically required for efficient working is deemed to be included in qouted rates. |
| 84 | Earthing complete with galvanised steel earth plate electroe 60 cmx60cm6mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connectedto and including galvanized earth lead GI Strip of size 32x6mm by means of GI bolt/snuts/washers, protected by 40mm bore GI light grade pipe from earth plate & upto 3m long pole fixed with 2 clamp made from mild steel flat iron 32x6mm bolts, nuts, washer etc. earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15cm thick all around buttom and top of earth plate 20mm dia GI Medium grade pipe for watering and including funnel, wire mesh, RCC cover & frame PCC 1:3:6 type C1 using 20mm graded stone aggregate as in earthing pit including necessary excavation & earth work all as specified & shown on electrical plate No. 3 of SSR Part-I, (Note: (i) PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner (ii) earthing for Lightning protection is also included in the above item) |
| 85 | S & fixing TPN DB 4 way with 200 amps bus bar rating of triple pole and neutral with double door 415 Volts complete all as specified and directed. |
| 86 | Supply and fixing of automatic steet light switch using INFRARED SENSOR based on NATURE SWITCH for automatic switch of street lights nature switch operation should be based on natural light lux level. Required illuminance level for switchning ON is <30 lux and for switching OFF>10 lux. The sensor should also have part night operation facility of minimum 4 hours to maximum 12 hours. The sensor alongwith suitable power contactors, incoming-outing MCBs, Auto-manual (Sensor By Pass) selection option should be enclosed in a pole/ wall mountable enclosure made of rust proof, electric shock proo, termite proof and FR grade SMC junction Box confirming to IP-54 Single phase load of 5KW with contactor 63 Amps, incomingrating 32-40 Amps and circuit wiring minimum 16 Sqmm copper conductor cable complete all as specified and directed by Engineer-in-Charge.Make: Healer Enterprises(SWADEEP-02EC8KW1P) or equivalent as approved by GE. |
| 87 | Supply and fixing of automatic steet light switch using INFRARED SENSOR based on NATURE SWITCH for automatic switch of street lights nature switch operation should be based on natural light lux level. Required illuminance level for switchning ON is <30 lux and for switching OFF>10 lux. The sensor should also have part night operation facility of minimum 4 hours to maximum 12 hours. The sensor alongwith suitable power contactors, incoming-outing MCBs, Auto-manual (Sensor By Pass) selection option should be enclosed in a pole/ wall mountable enclosure made of rust proof, electric shock proo, termite proof and FR grade SMC junction Box confirming to IP-54 Single phase load of 12KW with contactor 75-80 Amps, incomingrating 32-40 Amps and circuit wiring minimum 25 Sqmm copper conductor cable complete all as specified and directed by Engineer-in-Charge.Make: Healer Enterprises(SWADEEP-02EC8KW1P) or equivalent as approved by GE. |
| 88 | M&L for shifting of transformer of 100 to 400 KVAcapacity from one place to another place of 2.0 KM, including providing of suitable vehicle for shiftingcomplete all as specified and directed by Engineer-in-Charge. |
| 89 | Installation only Transformer step-down, 11/0.433 KVA complete, outdoor/indoor, copper wound, capacity 200 KVA all as specified and directed by Engineer-in-Charge. |
| 90 | M&L for shifting of pole of any type(steel/PCC)from one place to another place of 2.0 KM, including providing of suitable vehicle for shiftingcomplete all as specified and directed by Engineer-in-Charge. |
| 91 | Fixing only prestressed concrete pole, 11.0 metres long. 152mm x 152mm at top and 152mm x 260mm at bottom, class 9 complete all as specified and directed by Engineer-in-Charge. |
| 92 | Supply, fabricating , fixingstructural mild steelchannel angle iron, flat iron and brackets etc for fabrications of cross arms, bracings, supports, D-clamps, stiffeners, eye hooks, bolts, pole clamps and back platesincluding nuts, bolts and washers, welding banding cold , or hot drilling holes for insulators bolts in any shape or sizeas indicated or directed and inclusive of one red oxide primer coat ,one under coat and one finishing coat ofaluminium paint complete.(Insulators to be measured and paid for separately) |
| 93 | Excavation in trenches in any type of soilexceeding 1.5 mtr deep and notexceeding 3.0 mtr deep and not exceeding 1.5 mtrwide for laying of cables, RCC/Steel tubular poles/staysand struts etc getting outincluding trimmingsides and forming bottom surface all as specifiedand directedat site. |
| 94 | M&L for plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundation of PCC poles/struts as specified including necessary form work all as specified and directed. |
| 95 | M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundation of stay assembly etc including necessary form work, all as specified and directed. |
| 96 | M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles , including necessary form work finishing even and smooth without using extra cement , all as specified and directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy