| 1 | Taking down existing unserviceable aluminum / copper stove enamelled steel coduit point wiring of any description & in any position including all fitting and making good the disturbed surface to match with the existing surfaces complete all as specified and directed. |
| 2 | M&L forpoint wiringforwithstove enamelled steel coduit of suitable sizeincluding all fittings such as elbow, bends, junction boxes, saddles, etc. on surface with and including ISI marked two runs of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 sqmm nominal cross sectional area, 1100 volts grade and including one run of 1.5 sqmm (green colour) ISI marked PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire to be terminated in and incl MS rectangular block of suitable size for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover for one light point or one fan point controlled by one switch including making good the disturbed wall and painting the same with matching to existing wallall as specified and directed |
| 3 | Allas per Srl item No 2 above but point wiring for 5 pin socket outlet, 5 Amps on same board with other switches. |
| 4 | All as per Srl item No 2 above but point wiring for 5 pin socket outlet, 5 Amps on independent board. |
| 5 | All as per Srl item No 2 above but point wiring for one five pin socket outlet, 15 Amps & 5 Amp on independent board using2.5 sqmm two run and one run 2.5 sqmm (nominal area) stranded copper conductor cable. |
| 6 | Material & Labour for Sub main wiring at any height with 2 single core PVC insulated, multi stranded copper conductor cable (FRLSH), unsheathed, 1.5 sqmm, 1100 volt grade conforming to IS drawn instove enamelled steel coduit 20 mm dia including one single core PVC insulated multi stranded unsheathed copper conductor cable, 1.5 sqmm,, FRLSH green in colour as continuous earth wire including all accessories and fixing arrengements, supporting clamps, bends, sockets and connecting items etc. all as specified and directed. |
| 7 | Material & Labour for Sub main wiring at any height with 2 single core PVC insulated, multi stranded copper conductor cable (FRLSH), unsheathed, 2.5 sqmm, 1100 volt grade conforming to IS drawn instove enamelled steel coduit 20 mm dia including one single core PVC insulated multi stranded unsheathed copper conductor cable, 2.5 sqmm,, FRLSH green in colour as continuous earth wire including all accessories and fixing arrengements, supporting clamps, bends, sockets and connecting items etc. all as specified and directed. |
| 8 | M&L for casing capping point wiring suitable for One Light/Bell point controlled by one switchcomplete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 V grade confirming to IS 694 drwan through PVCcasing cappingof sizeheavy grade ISI marked including necessary casing capping with accessories, heavy duty PVC terminalincluding 1.5 mm PVC insulated FRLS copper conductor as in continious earth wire all as specified and directed. |
| 9 | All as item No-8 here in before but one ceiling / Exhaust fanpoint controlled by one switch all as specified and directed. |
| 10 | All as item No-8 here in before but one Light controlled by two-way switch all as specified and directed.. |
| 11 | All as item No-8 here in before but one 3 pin 5 Amps socket outlet on independent board as specified and directed.. |
| 12 | All as item No-8 here in before but one 3 pin 5 Amps socket outlet on same board as specified and directed.. |
| 13 | All as item No-8 here in before but one 15 Amp socket pointwith 4 Sqmm wireon independent board as specified and directed.. |
| 14 | Dismantling and Taking out old unserviceable copper/aluminium sub main wiring/aluminium armoured cable (used as Sub main wiring) from any height of any Size and Core with all connecting accessories incld. conduit or casing caping and incld. making good to the disturbed wall and painting the same with matching paint as of existing wall incld material all as specified and directed. |
| 15 | Material & Labour for Sub main wiring at any height with 2 single core PVC insulated, multi stranded copper conductor cable (FRLSH), unsheathed, 2.5 sqmm, 1100 volt grade conforming to IS drawn in PVC non metallic conduit 20 mm dia/capping casing including one single core PVC insulated multi stranded unsheathed copper conductor cable, 2.5 sqmm,, FRLSH green in colour as continuous earth wire including all accessories and fixing arrengements, supporting clamps, bends, sockets and connecting items etc. all as specified and directed. |
| 16 | Material and labour for Sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS, FRLSH type, 4.0 Sqmm, 1100 volts grade, drawn inPVC non metallic conduit 20 mm dia/capping casing including connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable,FRLSH type, 4.0 sqmm, 1100 Volts grade,,green in colour as earth contuinity wire all as specified and directed by Engineer in charge. |
| 17 | M & L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending colt or hot, drilling holes for bolts, at any height, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint for mounting Air Circulator / Exhaust Fan / Ceiling Fan/highbay fittings etcfor fixing arrangements complete. |
| 18 | Supply and fixingswitch piano flush button single pole one way 6 Amps, 220 V.Make : Belno,Legrand,Havells |
| 19 | Supply and fixingsocketoutlet 2 in 1,3 pin,5A flush type 220 V . Make : Belno,Legrand,Havells |
| 20 | Supply and fixingfor repairBell Push flash type,5A,single pole220 V. Make : Belno,Legrand,Havells |
| 21 | Supply and fixingfor repairtwo way switch 5A,single pole220 V. Make : Belno,Legrand,Havells |
| 22 | Supply and fixingsocket6A-2in one socket 5 pin combinedflush type 220 V .Make : Belno,Legrand,Havells |
| 23 | Supply and fixingswitch socket combination 2 in 1,3 pin,6/16 A andflush type 220 V with PVC box .Make : Belno,Legrand,Havells |
| 24 | Supply and fixingfor repairing Ceiling rose, surface bakelite, 65mm x 50mm two to three terminals.Make : Belno,Legrand,Havells |
| 25 | Supply and fixingElectronics dimmer piono switch type 450 watts,220 volt flush type. all as specified and directed .Make : Belno,Legrand,Havells |
| 26 | Supply and fixingPVC rectangular block for mounting,switches,sockets, fan regulator etc with 3mm thick plastick laminated sheet cover of size 100 mmx 100mm and 50mm deep. |
| 27 | Supply and fixingPVC rectangular block for mounting,switches,sockets ,fan regulator etc with 3mm thick plastick laminated sheetbcover of size 175 mmx 100 mm and 50mm deep. |
| 28 | Supply and fixingPVC rectangular block for mounting,switches,sockets, fan regulator etc with 3mm thick plastick laminated sheetbcover of size 200 mmx 150mm and 50mm deep. |
| 29 | Supply and fixingPVC rectangular block for mounting,switches,sockets, fan regulator etc with 3mm thick plastick laminated sheetbcover of size 250 mmx 200mm and 50mm deep. |
| 30 | Supply and fixing buzzer,Ding Dong AC 230 volts single pole. Make : Belno,Legrand,Havells |
| 31 | Supply and fixing bell multi musis AC 230 volts single pole. Make : Belno,Legrand,Havells |
| 32 | Supply and fixing lamp holder,PVC/Polycar bonate type with back plate suitable for batten fitting.Make-:Benlo,Havells,Legrand |
| 33 | Taking down unserviceable LED light fittings of any type from wall,ceilling for replace with new fitting and refixing the same location . |
| 34 | Supply and fixingand fixing of Supply and fixing Inverter LED batten 20 watt with square profile and polycarbonate channel. Lithium Ion battery with charging time 8hours-10 hours and back up time upto 4 hours. ..Make:-Havells,,Philips ,Belno |
| 35 | Supply and fixingand fixing environmental friendly, new generation, aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source, suitable for Armstrong/Grid ceiling type-PLUTO NEO PANEL 4X1.Fixture size: (LxWxH) in (1195x295x70) mm.Make:-Havells,Belno,Helonex |
| 36 | Supply and fixingand fixing of ENDURA WELL GLASS Neo - IP65 environmental friendly, energy saving long life corrosion resistant, vertical/horizontalmounting pressure die-cast aluminium well glass luminaires with high power LED Hi-Bay Light 30W.6500 K .Make:-Havells,Philips ,Belno |
| 37 | Supply and fixingand fixing Slim recess mounting luminaire with Strato 2x2 LED 36 watt edge-lit luminaire suitable for armstrong/grid ceiling complete for low ceiling applications complet all as directed.Havels all as directed.Make:-Havells,Belno,Helonex |
| 38 | Fixing of decorative surface / wall mounted/ LED batten/wall/celling light of any type.Light fitting will be issued as sch-B |
| 39 | Taking down unserviceable DB of any capacity and making good disturbed surface of wall/floor complete all as specified all as directed. |
| 40 | S & F Distribution board, SP&N vertical ,Prewired ,Netural links,blanking plates ,single door 8 way,with provision for MCB SP&N as incommer and SP/DB MCB as outgoing and electrically connecting up complete all as specified and directed.,Make : Bentec/Havells / Legrand |
| 41 | S & F Distribution board, SP&N vertical ,Prewired ,Netural links,blanking plates ,single door 6 way,with provision for MCB SP&N as incommer and SP/DB MCB as outgoing and electrically connecting up complete all as specified and directed. Make : Bentec/Havells / Legrand |
| 42 | S & F outdoor main control feeder pillar boxfor storage shade with IP-55 protection,madewith 3mmsheet with angle iron fram, suitable for installed 100 Amps MCCB as incommer,out going MCB SP&N=04 Nos with copper (30x6mm) distribution board having front opening with proper locking arrangement, complete all as specified and directed. |
| 43 | Taking down unserviceable MCB,MCCB of any capacity and making good disturbed surface of wall/floor complete all as specified all as directed. |
| 44 | S & F MCB SP 6 to 32 Amps 240 volts 50 HZ having 10 KAcomplete.Make : Bentec/Havells / Legrand |
| 45 | S & F MCB SPN32 Amps 240 volts 50 HZ having\"10 KAcomplete.Make : Bentec/Havells / L&T/Legrand |
| 46 | S & F MCB DP40 Amps 240 volts 50 HZ having 10 KAcomplete.Make : Bentec/Havells / L&T/Legrand |
| 47 | S & F MCB TPN40 Amps 240 volts 50 HZ having 10 KAcomplete.Make : Bentec/Havells / Legrand |
| 48 | S & F MCCB ,TPN,415 Volt AC 50HZ 100Amps , adjustable braking capacity 10KA complete all as directed.Make : Bentec/Havells / Legrand |
| 49 | M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick burried directly in ground, earth pit not less than 2.25 meters deep below ground level with top edge of the plate not less than 1.5mtr below GL connected to and including 32x6 mm GI strip upto 7.5 m long by means of GI bolts, nuts, check nuts& washersand connected to earthing test point& earth dolly all as shown in electrical plate No 3 of SSR part I- (2009), earth lead protected with and including 40 mm bore GI pipe light grade and 20 mm bore medium grade watering pipe and testing on completion including excavation & earth work in any type of strata ,UPE earth pit made with high grade polymer compound top dia 160mm bottom dia 235mm height 230mm,funnel with water pipe , wire mesh and lugs etc completeall as specified and directed.Location: FAD |
| 50 | M&L for earthing complete with galvanized steel pipe electrode,40 mm bore,medium grade,2.5 Mtrers length,buried directly and preferably vertically in ground with top edge not less than 1.25 meters below ground leavle cinnected with earthing lead of 4mm dia galvanised iron or steel wire all as shwn in Plate no-2 to the earthing test point all as specified and indicated including testing on completion. |
| 51 | S&F earth continuity conductor or main earthing lead of size32x6 mm GI strip fixed to wall drawn in conduit/pipe orany other indicated situation for loop earthingetc. incl removal of old as required all as specified and directed..Location: FAD |
| 52 | Taking down unserviceable GI pipe from trenches/floor/roofand Supply and fixingand laying GI pipe medium grade of size 50mm including necessary fitting all as directed |
| 53 | Suppy and layingXLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volt grade, cross sectional area 16 Sqmm 2 core . |
| 54 | Suppy and layingXLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volt grade, cross sectional area 35 Sqmm 3.5 core . |
| 55 | M & L for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation of stay assembly, poles, struts etc complete. |
| 56 | M&L Rendering 10 mm thick in cm 1:4 on other than fair faces of brick work or concrete surfaces. |
| 57 | M & L in repair HDPE DWC pipe 40 mm dia ISI Marked fixed on walls, ceilings or in floors, trenches etc. for cable protection all as directed. Make:-Infra/Supreme/Prince |
| 58 | M & L in repair HDPE DWC pipe 50 mm dia ISI Marked fixed on walls, ceilings or in floors, trenches etc. for cable protection all as directed. Make:-Infra/Supreme/Prince |
| 59 | Excavation in trenches n.exc 1.5 mtr wide and n exc 1.5 mtr in depth and getting out in soft/ loose soil for laying cables / GI pipe, foundation of pole, stayetc complete all as specified and as directed . |
| 60 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm in soft/loose soilcomplete all as specified and as directed. |
| 61 | Removing surplus excavated soil n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed. |
| 62 | Taking downthe ceilling fan/wall mounted fan,Exhust fan from ceilling,wall,cleaning the dust,drit ,greashing,serviceing ,repairing and refixing the original positin all as directed. Note:- Necessary spare for repairing will be measured and paid in respective items. |
| 63 | Taking down unserviceable ceiling fan and deposited to MES store yard and Supply and fixingnd fixing ceilling fan complete with blades, down rods,electronic regulator and accessories,230 volt,1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE star rated with brushless direct current motor(BLDC) |
| 64 | Taking down unserviceable Ventilating Fans and deposited to MES store yard Supply and fixingand fixing Ventil Air - DX Whitemade with sturdy engineering plastic completand accessories,230 volt,50 Hz,rpmcopper winding of sweep 150 mm.Make: Bajaj,Havells,Belno |
| 65 | Taking down unserviceable Ventilating Fans and deposited to MES store yard Supply and fixingand fixing Ventil Air - DX Whitemade with sturdy engineering plastic completand accessories,230 volt,50 Hz,rpmcopper winding of sweep 200mm..Make: Bajaj,Havells,Belno |
| 66 | Supply and fixingonly condenser 2.5 Mfd/3.5Mfd capacity MakeMake :Havells,HPL, Asian. |
| 67 | Taking down unserviceable busbar box Supply and fixingand fixing Cable Junction Boxes IP 65 with “plain walls”PVC heat radiant bus bar box of size 260mm x 210mm x 116mm ,IP-65 fitted with 1complet all as directed. .Make : Hensel |
| 68 | Taking down unserviceable light fitting,Supply and fixingand fixing Mushroom bolard with aluminium pipi housing with glare free mushroom shaped PMMA diffuser- IP65,H-600MM complet all as specified all as directed.Make:-Havells,,Helonix ,Benlo |
| 69 | Taking down unserviceable flood light fitting,Supply and fixingand fixing Inveter LEDflood llight 60 watt - IP66 ,PDC housing with battery backup 3-4 hours as per Helonix model No-INVERTER HLFLD-ML 30-60 CWL-INV-RTC-R complete all as specified all as directed.Make:-Halonix or equivalent Havells,,Philips ,Benlo |
| 70 | Taking down unserviceable stree/building security light fitting,Supply and fixingand fixing Inveter LED street llight 30 watt - IP66 ,PDC housing with battery backup 3-4 hours as per Helonix model No-LED SL30W HLSLD-ML-04-30-CWL-INV-RTC-R complete all as specified all as directed.Make:-Halonix or equivalent Havells,,Philips ,Benlo |
| 71 | Taking down unserviceable stree/building security light fitting,Supply and fixingand fixing Inveter LED street llight 45 watt - IP66 ,PDC housing with battery backup 3-4 hours as per Helonix model No-LED SL45W HLSLD-ML-04-45-CWL-INV-RTC-R complete all as specified all as directed.Make:-Halonix or equivalent Havells,,Philips ,Benlo |
| 72 | Taking down unserviceable stree/building security light fitting,Supply and fixingand fixing Inveter LED street llight 60 watt - IP66 ,PDC housing with battery backup 3-4 hours as per Helonix model No-LED SL60W HLSLD-ML-04-60-CWL-INV-RTC-R complete all as specified all as directed.Make:-Halonix or equivalent Havells,,Philips ,Benlo |
| 73 | Material and labour for Sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS, FRLSH type, 6.0 Sqmm, 1100 volts grade, drawn inPVC non metallic conduit 20 mm dia/capping casing including connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable,FRLSH type, 6.0 sqmm, 1100 Volts grade,,green in colour as earth contuinity wire all as specified and directed by Engineer in charge. |
| 74 | S&F in repair LED Recess mounted LED fitting 18 Watts CAT NOLHEBHDP7IZ1W018 of HAVELLS or HPLLEDINS018WWR of HPL or LNRO02R018SW/SC/SN of Jaquar . |
| 75 | S&F in repair LED Recess mounted LED fitting 18 Watts CAT NOLHEBHDP7IZ1W018 of HAVELLS or HPLLEDINS018WWS of HPL or LNRO02R018SW/SC/SN of Jaquar |
| 76 | Supply and fixingand fix in repair 10 watt LED Bollard pressure die cast powder coated housing withdiffuser ofIP 65 protection CAT NO SZPGBMX010 of Shakti or Equivalent in havells/bajaj with including junction box for connection and PCC work of fixing of light fittings. |
| 77 | Supply and fixingand fix inverted pyramid tripod type 10 watt LED Bollard pressure die cast powder coated housing withdiffuser ofIP 65 protection CAT NO LBLSN-10-WW of Crompton or Equivalent in havells/bajaj with including junction box for connection and PCC work of fixing of light fittings. |
| 78 | M & L for disconncting the Mainpower Supply and fixingfrom DB, taking down Electric KWH meter of any size,any type carefully & calibrate with proper load/ instruments in front of user & MES Rep, after proper calibration to refix with connection as per existing with sealed to meter complete all as specified.Note :i) All Qtr wise testing reports with sign of user & MES Rep kept in records. ii) if found faulty the rate for minor repair is included in this quoted rate. |
| 79 | S&F in repair Meter box 2mm thick MS sheet powder coated of size1mtr x 1mtr X 0.25mtr split in two parts 0.4X 1 mtr on top for refixing the meters and .6X 1 mtr for fixing of MCCB and DB.The front portion should be provided with glass of size 10cm x 10cm infront of each meters to facilitate recording of meter reading and including provision of wooden block of suitable size to fix the meters and DBs,door with locking arrangementincluding Removing and refixing of meters . |
| 80 | S&F in repair deep spot light 03 watt for low ceiling application in red/blue/green colour.MAKE :- LHEEBCP1UN1B003 of havells or Eq in Philips/Jaquar |
| 81 | Supply and fixingand fix in repair wall mounting fitting,decorative type ,champagne finish fixture with plastic body suitable for 9 w LED lamp B22 base all as specified and directed by Engr in charge.Make :- LHFOAIC1TZ1I040 of havells or eq in Philips/wipro/Bajaj |
| 82 | S&F in repair70 W LED HIGH BAY luminairecomplete of CAT No SZHHCPX070of Shakti or LHBLD1S070XCof Jaguar /Havells/HPL/Shakti/Crompton |
| 83 | S&F in replacement of decorative gate light made up of unbreakable polycarbonate suitable for retrofit LED lamp B22 base for mounting on pole /gate all as specified & directed by Engr-in-charge.Make :- LHFXBON1TN5Q008 of Havells or eq in bajaj/Wipro |
| 84 | S&F in repair On load change over switch 415V,4 polein sheet metal enclosure with current capacity 100 amp.MAKE:- CDC01004PEAV of HPL/Standard/Havellsor Equivalent. |
| 85 | S&F in repairOn load change over switch 415V,4 pole within sheet metal enclosure current capacity 63 amp.MAKE:- CDC00634PEAV of HPL/Standard/Havellsor Equivalent. |