|
| 1 | Earth work in excavation for Structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious materials and disposal upto a lead of 50 m, dressing of sides and bottom and back filling in trenches with excavated suitable material. PWD SOR S.I.No. 251/2022-23 |
| 2 | P/L cement concrete1 :6 :12 (1 cement: 6 F sand: 12 graded brick ballast 40 mm nominal size) including supply of all materials, labour & T&P etc. reqd. for proper completion of work as per direction of E/I. (PWD SI No.273/ 2022-23 |
| 3 | First Class brick work in 1:4 cement & coarse sandMortar in the super Structureincluding necessary cutting and moulding of bricks as required and also including honey comb brick, work work but forwall of one brick thick. including supply of all materials, labour and tools & plants etc required for proper completion of the workSOR 305(b)/2022-23 |
| 4 | 12 mm thick plaster 1:3 cement and coarse sand mortar including supply of all Material, Labour, T & P etc required of the completion of the work As per direction of E/I all complete. PWD SOR S I No.583/2022-23 |
| 5 | R.C.C. Work with cement approved coarse sand and 2 cm. (3/4\") guage approved stone grit in the proportion of 1:1.5:3 in slab excluding supply of reinforcement and its binding but including its fixing and binding the same with 24 B.W.G.G.I. binding wire, and including necessary centering and shuttering etc. and also including supply of all materials, labour and T & P etc. required for proper completion of the work. Binding wire cost being included in this Item.SI-284+Diff /SOR/2022-23)P.W.D(8315.00+1.63 bagx300.00 =8804.00) |
| 6 | Mild steel or Iron in plain work such as reinforced concrete or reinforced brick work (When not wrought to included in an overall rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised overlapping shall be measured upto floor two level.UPPWD S.O.R. S.I. No.504/2022-23) |
| 7 | Providing and laying in cement concrete 4:2:1 of not less than strength of M150 stone ballast (20 mm. nominal size) :2 approved coarse sand:1 cement and curing complete, including cost of formwork in foundation and floors.PWD SOR S.I. N0. 279(b)/2022-23 |
| 8 | Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 (Analysis Rate) |
| 9 | Providing and laying Rubber mouldedZig zag 80 mm thick tiles of precast compressed C.C. passing minimum 30 megapascle compressive strength. ISI Marked (in gray base) laid in required over 40mm thick compacted bed of local sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer, filling the joints with local sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as perdirection of Engineer-in-Charge(Analysis Rate) |
| 10 | Mild steel or iron work in heavy sizes and sections such as trusses builtup gates, door frame, record racks, roof work, gates etc. wroughtto required from including drilling holes, rivetting where necessary and also including supply of steel, bolts, nuts etc, & thier fixing required fof proper completion ofthe work SOR 2020-21 S.I.No- 503 |
| 11 | Painting or varnishing on iron works in small areas or new wood work with one coat of ready mixed priming paint & Two coats of approved superior quality ready mixed paint of clear synthetic varnish including supply of all materials, labour and T & P etc. required for proper completion of work, paint to be used shuld confirm to the I.S.I. No. 103 1950 PWD SOR S I No 641+642/2022-23 |
| 12 | Same as item no. 11 as above but two coats on privious painted surface PWD SOR S I No 643/2022-23 . |
| 13 | P/Fof Reflective Signs with a corrosion resistant 4 mm thick aluminium composite panel face to be fully covered with high Intensity primatic sheeting type IV as per IRC-67:2010 recto reflective sheeting with MS angle frame of 35x3 including Supply of all materials, labour, T & P netc. required for all complete of the work as per direction of E/I (Analysis Rate) |
| 14 | S/F ofreflective raised Pavement maker (Cats Eyes)Type X- ASTMD-4956-04Avery Dennision/3- M (USA Make) consisting of ASA plastic housing fitted with tightly adhernt plotting compound. the housing shall contain primatic two glass covered prismatic reflective face to reflect incident light I.C all tax etc. complete. |