| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-09-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 01-10-2024 |
| Sl. No. | Item Description |
| 1 | Disconnecting & taking out old unserviceable LT cable of any size all as specified and directed |
| 2 | Supply, laying, jointing, connecting, testing & commissioning UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured electric power cable (heavy duty 1100 volts grade with standard aluminium conductor of cross sectional area 150 sqmm x 3.5 core all as specified and directed.NOTE - (a). The quoted rate is deemed to be inclusive of arranging respective shutdown, disconnection of cables, commissioning of feeder after the completion of job and inclusive of any minor spares and jobs required for the completion of the job. (b). The cost of excavation, returning, filling, removal and PCC cable covers will be measured and paid under relevant items of this schedule. |
| 3 | All as per ser item No 2 here-in-before but size of LT under ground cable 120 sqmm 3.5 core all as specified and directed. |
| 4 | All as per ser item No 2 here-in-before but size of LT under ground cable 95 sqmm 3.5 core all as specified and directed. |
| 5 | All as per ser item No 2 here-in-before but size of LT under ground cable 50 sqmm 3.5 core. all as specified and directed |
| 6 | All as per ser item No 2 here-in-before but size of LT under ground cable 35 sqmm 3.5 core.all as specified and directed. |
| 7 | All as per ser item No 2 here-in-before but size of LT under ground cable 25 sqmm 4 core. .all as specified and directed |
| 8 | Excavation in trenches in soft/loose/hard soil n exc 1.5 m wide and not exc 1.5 m in depth and getting out including forming bottom to required level or slope for laying pipes / laying of cable complete all as specified and as directed |
| 9 | Returning filling in soft / loose soil in trenches including spreading, leveling and well ramming in 25 cm thick layers complete all as specified and as directed. |
| 10 | Removal of surplus soil to a distance n exc in 50 m and deposited where directed at a level n exc 1.5 m above the starting point complete all as specified and as directed |
| 11 | Material and labour sand cushioning (dry sand) to underground cable for cable protection 23 cm thick in two layers (8 cm thick before laying of cables and 15 cm thick after laying the cable and punning down the sand to 18 cm thickness.) complete all as specified and as directed(Note:- Only punned thickness 18 cm of sand shall be measured for payment purposes). |
| 12 | Material and labour for laying of precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm complete all as specified and directed. |
| 13 | M&L for making bore to road width including provision 100mm dia GI pipe ight grade both end socketed for passing armoured cable complete all as specified and directed |
| 14 | Material and labour for galvanized iron tubing size 80 mm bore (Light grade) with all necessary fittings laid in trenches under road crossing or fixed on poles / walls / under floors for cable protection complete all as specfied and as directed. |
| 15 | Material and Labourfor earthingwith galvanised iron earth plate of size 600x600x6mm thick buried directly in ground not less than 2.25m below normal ground level, earth plate packed on all sides with charcoal mixed with salt in alternate layers of 15 cm thickness connected by galvanised iron earth earth strip 32x6mm soldered & riveted to earth plate, galvanised iron earth strip will be provided by using 50mm bore galvanised iron pipe (light grade) earth plate to transformer body and neutralor test point of transformer, including flat iron clamp 25x3mm including bolts, nuts and washers complete including watering galvanised iron pipe 20 mm dia \"Light grade\" 2.5m long the earthing includes PCC pit including necessary earth works and disposal of surplus soil to a distance not less than 50m, chamber of PCC 1:4:8 type D-2 using 40mm graded stone aggregate, coping shall be of PCC 1:3:6 type C-I using 20mm graded stone aggregate, RCC pit cover 50mm thick in 1:2:4 type B-I using 20mm graded stone aggregate, reinforced with 8mm dia @ 15cm c/c complete all as shown on sketch No 3 of SSR-I of 2009 and as specified. |
| 16 | Material and Labour for Under ground LT Cable fault detecting by under ground cable fault locator including excavation the exact location for repair work and returning filling as existingafter repair complete all as specified and directed. Note:- Contractor shall attend complaint with in 24 hrs & maintenence shall be carried out accordingly for smooth functioning of elect supply cost of the same shall deemed to be included inthe above coated rates, if not repaired, penalty will be charged Rs-500/-per day. |
| 17 | Material and Labour in replacement ofearth continuity conductor GI of 32x6 mm of GI strip by means of bolts, nuts, check nuts and GI washers complete all as specified and directed |
| 18 | Material and Labour for Synthetic insulating mat (rubber matting), ISI Marked suitable for 1100 Volts electrical grade 2mX1mX20mm thick chequered top, ISI marked to be laid in front of LT/HT panel board complete all as specified and directed |
| 19 | Material and Labour in replacement of Danger notice boards of 1.6mm thick mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for LT 20x15 cm size. all as specified and directed. |
| 20 | Material & Labour for application of two coats of aluminium paint on steel tubular/rail pole of 9/11/13/15 M long externally after removal of old paint, rust, dust, oil, grease or any other foreign deposits by paint removers or burning off by blow lamps, cleaning with scrapers and chemicals for removal of rust for any number of coats of any width or girth incl. numbering of poles in black base & white letters paint and including. painting five no. strips upto 30 cm on bottom of pole with black and yellow colour paint alternatelyall as specified and directed |
| 21 | Material & Labour for repair of LT Panels,welding, drilling with 6 nos hinges and 2 nos stainless steel manual lock with locking arrangement including necessary arrangements, stainless steel hinges, manual lock, nut, bolt andwasherto electric control LT panel doors atinstallations by cleaning the panels by mechanical tools complete all as specified and directed |
| 22 | Supply and fix cable jointing kit for 1100 V grade cable for straight through joint complete with jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Aluminium conductor cable of size upto 25 to 50 sqmm core outdoor type and detecting fault complete all as specified and directed |
| 23 | Supply and fix cable jointing kit for 1100 V grade cable for straight through joint complete with jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Aluminium conductor cable of size upto 70 to 120 sqmm core outdoor type and detecting fault complete all as specified and directed |
| 24 | Supply and fix cable jointing kit for 1100 V grade cable for straight through joint complete with jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Aluminium conductor cable of size upto 150 to 185 sqmm, core outdoor type and detecting fault complete all as specified and directed |
| 25 | Supply and fix cable jointing kit for 1100 V grade cable for straight through joint complete with jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Aluminium conductor cable of size upto 240 to 300 sqmm, core outdoor type and detecting fault complete all as specified and directed |
| 26 | Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown and Supply & Fix MCCB FP, 36kA, 400 AMPS with Thermal - Magnetic Release Type Ics = 100% Icu, Adjustable Over Load setting: 0.4 -1.0 x In, Adjustable short circuit for each phase from 1.5 - 8 x In, including spreader terminalsall as specified and directed.NOTE - Quoted rate is deemed to be inclusive of minor jobs and minor spares required for fitment of MCCB in the existing panel all as specified and directed |
| 27 | Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, Supply & Fix MCCB TP, 25kA, 250 AMPS with Thermal - Magnetic Release Type, Ics = 100% Icu, Adjustable Over Load setting: 0.4 -1.0 x In, Adjustable short circuit for each phase from 6 - 10 x In, including spreader terminalsall as specified and directed NOTE - Quoted rate is deemed to be inclusive of minor jobs and minor spares required for fitment of MCCB in the existing panel all as specified and directed |
| 28 | Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, Supply & Fix MCCB TP, 25 kA, 200 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, Adjustable short circuit for each phase from 6 - 10 x In, including spreader terminalsall as specified and directed. NOTE - Quoted rate is deemed to be inclusive of minor jobs and minor spares required for fitment of MCCB in the existing panel all as specified and directed |
| 29 | Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, Supply & Fix MCCB TP, 25 kA, 160 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, Adjustable short circuit for each phase from 6 - 10 x In,including spreader terminalsall as specified and directed. NOTE - Quoted rate is deemed to be inclusive of minor jobs and minor spares required for fitment of MCCB in the existing panel all as specified and directed |
| 30 | Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, Supply & Fix MCCB TP, 25 kA, 125 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, Adjustable short circuit for each phase from 6 - 10 x In,NOTE - Quoted rate is deemed to be inclusive of minor jobs and minor spares required for fitment of MCCB in the existing panel all as specified and directed |
| 31 | Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, Supply & Fix MCCB TP, 25 kA, 63 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, Adjustable short circuit for each phase from 6 - 10 x In, including spreader terminalsall as specified and directed.NOTE - Quoted rate is deemed to be inclusive of minor jobs and minor spares required for fitment of MCCB in the existing panel all as specified and directed |
| 32 | Material and Labour for inspection of LT FPB all connected accessories/ components like MCCB/MCB/ACB ON-OFF/Tripping operations, metering devices, cable lugs joints, bus bar connections, insulators, wiring, CTs, etc., cleaning of LT FPB using dry air pressure, vacuuming out all dust/foreign particles using vaccum cleaner complete, removing flash over/burnt carbon particles from cable lug joints, bus bars, etc. with CRC 226 or WD14 or equivalent cleaner, tightening of nuts/bolts and other electric connections, disconnecting all incoming and outgoing connected cables, cutting off burnt portions, crimping with suitable size copper lugs and connecting up inclusive of replacement of cable glands (if any) all as directed at site by Engr-in-charge. Note:- (a). All spares like LED indicating lamps, ACB/MCCB/MCB, fuses with holders, voltmeter, ammeter, CTs, selector switches, copper/aluminium bus bar, control wiring, etc. required for replacement shall be measured and paid separately under relevant items of BoQ here-in-after, however the quoted rate is deemed to be inclusive of cost of cleaning agents, grease, cable lugs, cable glands, nut/bolt and washer combination all as approved by Engr-in-Charge. (b). The contractor has to arrange for electrical shutdown prior to carry own repairs. |
| 33 | Material and Labour for sheet metal work for replacement of unservicable panel doors, bus bar cover, metering devices/relay mounting doors in complete alignment with panel\"s existing doors with 3mm thick CRCA MS sheet duly powder coated with Seimens grey shade RAL 7032 or of shade as specified including necessary cutting of MS sheet so as to incorporate old serviceable panel accessories like LED indicating lamps, volt/ammeter, selector switches, MCCB/MCB handles, etc. welding and fixing jobs and dismantling of unservicable/rusted doors to the complete satisfaction and as directed and specified by Engr-in-Charge.NOTE - (a). The contractor has to arrange for electrical shutdown prior to carry own repairs. (b). The quoted rate is deemed to be inclusive of cost of hinges, panel locks, accessories required for flush fitting of old serviecable LED indicating lamps, volt/ammeter, selector switches, MCCB/MCB handles, etc. on the new door or any other materials required for fixing and proper operations of door. |
| 34 | Supply and replace existing unservicable indicating lamp LED type suitable to operate on 230 volts AC Supply of R/Y/B colour as per site requirement all as specified and directed |
| 35 | Supply & fix in replacement Single function 3 phase LED ammeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input current measurement range 0-200 A, CT/PT site programmable including suitable size CTs (set of 3) all as specified and directed |
| 36 | Supply & fix in replacement Single function 3 phase LED voltmeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable including suitable size CTs (set of 3) -all as specified and directed |
| 37 | Supply and replace existing unservicable selector switch for voltmeter all as specified and directed |
| 38 | Supply and replace existing unservicable selector switch for Ammeter all as specified and directed |
| 39 | Supply and replace existing unserviceable CT as that of existing ratio and model suitable for 3 phase supply all as specified and directed |
| 40 | Painting to electric control panel byspraying with grey colour of E/M installations by cleaning the existing old paint with the help of mechanical tools such as wire brush, scraper and sand paper from the surface of panel and painting the prepared surface with two coat of synthetic enamel paint of approved shade over a coat of red oxide primer complete all as specified and specified. |
| 41 | Repairing/servicing of APFC panel board by replacing the all defective components with new components, re-wiring, cleaning, testing, reconnecting, re-installing and commissioning the APFC panel board complete all as specified and directed |
| 42 | Supply & fix in replacement APFC relay of 8 stage supply Voltage 415 V AC and current Input - 1A or 5 A with specs as - 3 Phase Current and Voltage measurement, PF display - 3 Digit after decimal, Individual harmonics measurement up to 31st order, Dual PF setting for Mains - DG application, Communication through Inbuilt MODBUS RS-485 Protocol all as specified and directed |
| 43 | Supply & fix in replacement APFC relay of 16 stage supply Voltage 415 V AC and current Input - 1A or 5 A with specs as - 3 Phase Current and Voltage measurement, PF display - 3 Digit after decimal, Individual harmonics measurement up to 31st order, Dual PF setting for Mains - DG application, Communication through Inbuilt MODBUS RS-485 Protocol all as specified and directed |
| 44 | Dismantling, supply and install, connect, test and commission of capacitor, 3 phase, Super Heavy Duty cylindrical type, self standing units, self healing property with MPP film with safety device in the form of pressure sensitive (over pressure) mechanical interrupter, 415/440V, 3 phase, 50 Hz, Capacity 5 KVAR, AC conformance to Standards IEC 60831-1 2/96, IS 13340 including testing, commisioning as in repairs complete all as specified and directed. |
| 45 | All as per item no 44 here-in-before but 10 KVAR all as specified and directed |
| 46 | All as per item no 44 here-in-before but 15 KVAR all as specified and directed |
| 47 | All as per item no 44 here-in-before but 20 KVAR all as specified and directed |
| 48 | All as per item no 44 here-in-before but 25 KVAR all as specified and directed |
| 49 | All as per item no 44 here-in-before but 48.50/50 KVAR all as specified and directed |
| 50 | Supply and fix in repairs power capacitor duty contactor 3 phase with auxilary switch block 415 volts suitable for 10 kVAR capacitor complete with connected switch gear/ components in various APFC panelsall as specified and directed |
| 51 | Supply & fix in repairs power capacitor duty contactor 3 phase with auxilary switch block 415 volts suitable for 15 kVAR capacitor complete with connected switch gear/ components in various APFC panels all as specified and directed |
| 52 | Supply & fix in repairs power capacitor duty contactor 3 phase with auxilary switch block 415 volts and Spreader Link Kit suitable for 25 kVAR capacitor complete with connected switch gear/ components in various APFC panelsall as specified and directed |
| 53 | Supply & fix in repairs power capacitor duty contactor 3 phase with auxilary switch block 415 volts and Spreader Link Kit suitable for 48.50/50 kVAR capacitor complete with connected switch gear/ components in various APFC panels all as specified and directed |
| 54 | Supply & fix in repairs NO element complete switch gear/components in various APFC panels all as specified and directed |
| 55 | Supply & fix in repairs NC element complete switch gear/components in various APFC panels all as specified and directed |
| 56 | Supply & fix in repairs illuminated push button- RED complete switch gear/components in various APFC panels all as specified and directed |
| 57 | Supply & fix in repairs illuminated push button- GREEN complete switch gear/components in various APFC panels all as specified and directed |
| 58 | Supply & fix in repairs 1.1 KV current transformer of ratio 150/5 complete switch gear/components in various APFC panels all as specified and directed |
| 59 | Supply & fix in repairs 1.5 Sqmm multistranded copper FRLSH wire for control circuit complete switch gear/components in various APFC panels all as specified and directed |
| 60 | Supply & fixin repairs 2.5 Sqmm multistranded copper FRLSH wire for control circuit complete switch gear/components in various APFC panels all as specified and directed |
| 61 | Supply & fix in repairs 4.0 Sqmm multistranded copper FRLSH wire for control circuit complete switch gear/components in various APFC panels all as specified and directed |
| 62 | Supply & fix in repairs 6 sqmm multistranded FRLSH copper flexible cable complete switch gear/components in various APFC panels all as specified and directed |
| 63 | Supply & fix in repairs 10 sqmm multistranded FRLSH copper flexible cable complete switch gear/components in various APFC panels all as specified and directed |
| 64 | Supply & fix in repairs 16 sqmm multistranded single core copper conductor (Flexible) PVC Insulated Heavy Duty Industrial Cables for control circuit complete in various APFC panels all as specified and directed |
| 65 | Supply & fix in repairs 35 sqmm multistranded single core copper conductor (Flexible) PVC Insulated Heavy Duty Industrial Cables for control circuit complete in various APFC panels all as specified and directed |
| 66 | Supply & fix in repairs 1.5 sqmm pin type lugs complete switch gear/components in various APFC panels all as specified and directed |
| 67 | Supply & fix in repairs 6 sqmm pin/fork/round type lugs complete switch gear/components in various APFC panels all as specified and directed |
| 68 | Supply & fix in repairs 6-32 A SP MCB, 10 kA \"C\" series, 240 V AC, 50 Hz complete switch gear/components in various APFC panels all as specified and directed |
| 69 | Supply & fix in repairs 2 way selector adaptor 25 Amps complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge |
| 70 | Dismantling old LT panel and Supplying, installing, testing and commissioning of APFC panel with heavy duty capacitor and MCCB as incomer of 250 kVAR factory fabricated of size and of technical specs adhereing to existing IEC 61439 Part 1 & 2 norms, floor mounted, IP 55 grade, outdoor type Panel double door type LT cubical panel made out of3.15 MM thick CRCA MS sheet duly powder coated with Seimens grey shade RAL 7032, dust and vermin proof with suitable size TPN PVC sleeved aluminium bus bar, including aluminium bus bars for incoming and outgoing connections supported on glass fiber reinforced thermosetting plastic insulated support with lifting lugs of suitable size. Panel should be mounted/grouted PCC (1:4:8) type D2of size on as per the panel dimensions such that there should be 100 mm offsets complete. The bottom of the panel (space between bottom of panel and top of PCC foundation) shall be covered with CRCA sheet covering all the sides of the base frame duly painted with two coats of synthetic enamel paint of approved shade over one coat of red oxide primer. The panel should have following accessories fitted in :- Powder Coated Siemens Grey Panel Inner Box made out of 2.0mm thick sheet steel - 01 Set INCOMER :- (i) MCCB 315 Amp. TP 35 KA Thermal Magenetic - 01 Nos (ii) Rotary operating mechanism - 01 Nos(iii) Spreader suitable for 315 Amp MCCB TP - 02 Sets of three (iv) Automatic Power Factor Controller Relay 12/16 Stage - 01 Nos(v) Automanual Selector Switch 1 Pole 2 way - 01 Nos(vi) Amp. Meter digital Type - 01 Nos (vii) Amp Meter Selector Switch - 01 Nos(viii) Volt Meter Digital Type (0-500 Volt) - 01 Nos (ix) Volt Meter Selector Switch - 01 Nos(x) Phase indication light RED - 01 Nos (xi) Phase indication light Yellow - 01 Nos |
| 71 | (xii) Phase Indication LIGHT Blue- 01 Nos(xiii) Control MCB 6 Amp 10 KA - 06 Nos(xiv) Current Transformer 315/5A - 03 Nos OUTGOINGS:- 50 KVAR Capacitor Bank :- (i) MCCB 125 Amp TP 25 KA- 01 Nos(ii) ON Indication Light RED - 01 Nos(iii) OFF Indication Light GREEN - 01 Nos(iv) Red Stop Push Button with block - 01 Nos(v) Green Start Push Button with block - 01 Nos(vi) MDXL Heavy Duty Capacitor 415 Volt 50Kvar*3Nos - 150 Kvar(vii) Capacitor Duty Contactor suitable for 50 Kvar capacitor, 3phase, 415volts with NO+NC Auxiliary Contacts - 01 Nos25 KVAR Capacitor Bank :-(i) MCB 63 Amp TP 10 KA - 03 Nos(ii) ON Indication Light RED - 03 Nos(iii) OFF Indication Light GREEN - 03 Nos(iv) Red Stop Push Button with block - 03 Nos (v) Green Start Push Button with block - 03 Nos (vi) MDXL Heavy Duty Capacitor 415 Volt 25Kvar*3 Nos - 75 Kvar (vii) Capacitor Duty Contactor suitable for 25 Kvar capacitor, 3phase, 415volts with NO+NC Auxiliary Contacts - 03 Nos |
| 72 | 10 KVAR Capacitor Bank :-(i) MCB 25 Amp TP 10 KA - 01 Nos(ii) ON Indication Light RED - 01 Nos(iii) OFF Indication Light GREEN - 01 Nos(iv) Red Stop Push Button with block - 01 Nos(v) Green Start Push Button with block - 01 Nos(vi) MDXL Heavy Duty Capacitor 415 Volt 10Kvar*1 Nos - 10 Kvar(vii) Capacitor Duty Contactorsuitable for 10 Kvar capacitor, 3phase, 415volts with NO+NC Auxiliary Contacts - 01 Nos5 KVAR Capacitor Bank :-(i) MCB 16 Amp TP 10 KA - 02 Nos (ii) ON Indication Light RED - 02 Nos(iii) OFF Indication Light GREEN - 02 Nos iv) Red Stop Push Button with block - 02 Nos(v) Green Start Push Button with block - 02 Nos(vi) MDXL Heavy Duty Capacitor 415 Volt , 5Kvar*3 Nos - 15 Kvar(viiii) Capacitor Duty Contactor suitable for 5 Kvar capacitor, 3phase, 415volts with NO+NC Auxiliary Contacts - 02 NosAir Fan 6\" - 02 NosAuxiliary contact - 10 Nos |
| 73 | BUS BARS :- 400Amp, TPN 415Volts 3Phase 4Wire Color Coded Aluminum busbars (for outgoings & Incomings)- 01 SetMISCELLANEOUS:-Nuts, Bolts, Washers, Ferul Numbers, Cable Ties, Tie Base, Copper PVC Control Wire, Power Wire, Copper, Thimbles, Panel Locks, I-Hooks, PVC Tape, Insulators, E-type, L-Type, Round Type, MCB Chanel, PVC Chanel, Connector Chanel, Connectors, Foam Ga - 01 Lot |
| 74 | Dismantling old LT panel and Supplying, installing, testing and commissioning of APFC panel with heavy duty capacitor and MCCB as incomer of 500 kVAR factory fabricated of size and of technical specs adhereing to existing IEC 61439 Part 1 & 2 norms,OEM approved,floor mounted, IP 55 grade, outdoor type Panel double door type LT cubical panel made out of 3.15 MM thick CRCA MS sheet duly powder coated with Seimens grey shade RAL 7032, dust and veremin proof with suitable size TPN PVC sleeved aluminium bus bar, incld. aluminium bus bars for incoming and outgoing connections supported on glass fiber reinforced thermosetting plastic insulated support with lifting lugs of suitable size. Panel should be mounted/grouted PCC (1:4:8) type D2of size on as per the panel dimensions such that there should be 50 cm offsets complete. The bottom of the panel (space between bottom of panel and top of PCC foundation) shall be covered with CRCA sheet covering all the sides of the base frame duly painted with two coats of synthetic enamel paint of approved shade over one coat of red oxide primer. The panel should have following accessories fitted in :- Powder Coated Siemens Inner Grey Panel Box made out of 2mm thick sheet steel - 01 Set INCOMER :- (i) MCCB 630 Amp. TP 50 KA Thermal Magenetic - 01 Nos(ii) Rotary operating mechanism - 01 Nos(iii) Spreader suitable for 630 Amp MCCB TP - 02 Sets of three(iv) Automatic Power Factor Controller Relay 12/16 Stage - 01 Nos (v) Automanual Selector Switch 1 Pole 2 way - 01 Nos (vi) Amp. Meter digital Type - 01 Nos(vii)Amp Meter Selector Switch - 01 Nos (viii) Volt Meter Digital Type (0-500 Volt) - 01 Nos (ix) Volt Meter Selector Switch - 01 Nos (x) Phase indication light RED - 01 Nos (xi) Phase indication light Yellow - 01 Nos(xii) Phase Indication LIGHT Blue- 01 Nos(xiii) Control MCB 6 Amp 10 KA - 06 Nos(xiv) Current Transformer 630/5A - 03 Nos |
| 75 | OUTGOINGS:- 100 KVAR Capacitor Bank :- (i) MCCB 250 Amp TP 35 KA- 01 Nos(ii) ON Indication Light RED - 01 Nos(iii) OFF Indication Light GREEN - 01 Nos(iv) Red Stop Push Button with block - 01 Nos(v) Green Start Push Button with block - 01 Nos(vi) MDXL Heavy Duty Capacitor 415 Volt 100Kvar*1Nos - 100 Kvar(vii) Capacitor Duty Contactor suitable for 100 Kvar capacitor, 3phase, 415volts with NO+NC Auxiliary Contacts - 01 Nos50 KVAR Capacitor Bank :- (i) MCCB 125 Amp TP 25 KA- 01 Nos(ii) ON Indication Light RED - 01 Nos(iii) OFF Indication Light GREEN - 01 Nos(iv) Red Stop Push Button with block - 01 Nos(v) Green Start Push Button with block - 01 Nos(vi) MDXL Heavy Duty Capacitor 415 Volt 50Kvar*6Nos - 300 Kvar(vii) Capacitor Duty Contactor suitable for 50 Kvar capacitor, 3phase, 415volts with NO+NC Auxiliary Contacts - 01 Nos25 KVAR Capacitor Bank :-(i) MCB 63 Amp TP 10 KA - 03 Nos(ii) ON Indication Light RED - 03 Nos(iii) OFF Indication Light GREEN - 03 Nos(iv) Red Stop Push Button with block - 03 Nos (v) Green Start Push Button with block - 03 Nos 2.5 mm air gap between testing(vi) MDXL Heavy Duty Capacitor 415 Volt 25Kvar*2 Nos - 50 Kvar (vii) Capacitor Duty Contactor suitable for 25 Kvar capacitor, 3phase, 415volts with NO+NC Auxiliary Contacts - 03 Nos |
| 76 | 15 KVAR Capacitor Bank :-(i) MCB 32 Amp TP 10 KA - 01 Nos(ii) ON Indication Light RED - 01 Nos(iii) OFF Indication Light GREEN - 01 Nos (iv) Red Stop Push Button with block - 01 Nos (v) Green Start Push Button with block - 01 Nos(vi) MDXL Heavy Duty Capacitor 415 Volt 15Kvar*2 Nos - 30 Kvar (vii) Capacitor Duty Contactor suitable for 15 Kvar capacitor, 3phase, 415volts with NO+NC Auxiliary Contacts - 01 Nos10 KVAR Capacitor Bank :-(i) MCB 25 Amp TP 10 KA - 01 Nos(ii) ON Indication Light RED - 01 Nos(iii) OFF Indication Light GREEN - 01 Nos(iv) Red Stop Push Button with block - 01 Nos(v) Green Start Push Button with block - 01 Nos(vi) MDXL Heavy Duty Capacitor 415 Volt 10Kvar*1 Nos - 10 Kvar (vii) Capacitor Duty Contactorsuitable for 10 Kvar capacitor, 3phase, 415volts with NO+NC Auxiliary Contacts - 01 Nos 5 KVAR Capacitor Bank :-(i) MCB 16 Amp TP 10 KA - 02 Nos(ii) ON Indication Light RED - 02 Nos(iii) OFF Indication Light GREEN - 02 Nos |
| 77 | (iv) Red Stop Push Button with block - 02 Nos(v) Green Start Push Button with block - 02 Nos(vi) MDXL Heavy Duty Capacitor 415 Volt , 5Kvar*2 Nos - 10 Kvar(viiii) Capacitor Duty Contactor suitable for 5 Kvar capacitor, 3phase, 415volts with NO+NC Auxiliary Contacts - 02 NosAir Fan 6\" - 02 NosAuxiliary contact - 10 NosBUS BARS :- 400 Amps,TPN 415 Volts 3Phase 4Wire Color Coaded Aluminum busbars (for outgoings & Incomings)- 01 SetMISCELLANEOUS:-Nuts, Bolts, Washers, Ferul Numbers, Cable Ties, Tie Base, Copper PVC Control Wire, Power Wire, Copper, Thimbles, Panel Locks, I-Hooks, PVC Tape, Insulators, E-type, L-Type, Round Type, MCB Chanel, PVC Chanel, Connector Chanel, Connectors, Foam Ga - 01 Lot |
| 78 | Material & Labour for dismantling old unserviceable LT panel along with disconnecting connected cables, supplying, installing, testing and commissioning of 415Volts 3Phase 4 Wire factory fabricated and tested all as per existing IEC 60439 Part 1, OEM approved, floor mounted, IP 55 grade, Outdoor type double doorLT cubical panel made out ofCRCA MS sheet duly powder coated with Seimens grey shade RAL 7032, dust and veremin proof with suitable size TPN PVC sleeved aluminium bus bar, angle iron base frame of suitable size. Panel should be mounted/grouted on 150 mm thick PCC (1:4:8) type D-2 above nearest ground level and should be with 400 mm offsets on all 04 sides of the panel complete and should be inclusive of following fitted in accessories :- INCOMMING i) MCCB 250 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications -01 No. -OUTGOING(i) MCCB 100 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications- 03 Nos. - (ii) MCCB 63 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications- 02 Nos |
| 79 | (iii) LED indicators - R/Y/B 240 V AC - 18 Nos. - 03 Nos per Incoming and outgoing feeders.(iv) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours including suitable size CTs (set of 3) - 01 No. (for Incoming) (v) Single function 3 phase LED voltmeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable and including suitable size CTs (set of 3) - 05 Nos. (Outgoing feeders) (vi) Single function 3 phase LED ammeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable including suitable size CTs (set of 3) - 05 Nos. (Outgoing feeders)(vii) MCB SP \"C\" series 10kA 60-32 Amps as protection for LED lamps (01 No. each for set of 03 Nos. LED lamps, multifunction and single function meters) and multifunction meter-18 Nos.(viii) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc.(ix) MCB SP \"C\" series 10kA 60-32 Amps as protection for LED lamps (01 No. each for set of 03 Nos. LED lamps, multifunction and single function meters and multifunction meter - 6 Nos. (x) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc. |
| 80 | Material & Labour for supplying, installing, testing and commissioning of 415Volts 3Phase 4 Wire factory fabricated and tested all as per existing IEC 60439 Part 1, floor mounted, IP 55 grade, Outdoor double doortype LT cubical panel made out ofCRCA MS sheet 3.15 mm duly powder coated with Seimens grey shade RAL 7032, dust and veremin proof with suitable size TPN PVC sleeved aluminium bus bar including angle iron base frame of suitable size. Panel should be mounted/grouted on 150 mm thick PCC (1:4:8) type D-2 above nearest ground level and should be with 400 mm offsets on all 04 sides of the panel complete and should be inclusive of following fitted in accessories :-A. INCOMING(i) MCCB 250 Amps ,415 V 4 pole 36 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type including spreader terminals - set of 04 and direct rotary handle - 01No as per OEM specifications - 01 No.B. OUTGOING (ii) MCCB 160 Amps, 415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type as per OEM specifications - 02 Nos. -(iii)02 (Two) No of spare cubicles for incorporating 3 Phase Pre-paid Meters size of LxB = 500x 500 mm |
| 81 | (iv) LED indicators - R/Y/B 240 V AC - 03 Nos per Incoming and outgoing feeders. (v) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours and including suitable size CTs (set of 3) - 01 No. (01 NO. for Incoming feeder)vi) Single function 3 phase LED ammeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable and including suitable size CTs (set of 3) - 2 Nos.(vii) MCB SP \"C\" series 10kA 60-32 Amps as protection for LED lamps (01 No. each for set of 03 Nos. LED lamps, multifunction and single function meters) and multifunction meter - 3 Nos. (ix) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc.Note for Item Nos 70 to 73 above:- a. Panel drawing must be approved prior to placing PO to the Panel manufacturer from the AGE {I}.b. To ensure safety, reliability and accountability of component co-ordination, all the major components such as circuit breakers, contactors and the enclosure system called for in this specification should preferably be from a single manufacturer. The OEM shall be preferably manufacturer of aforesaid components and switchgear. |
| 82 | Repairing/servicing of APFC panel board ranging from 150 - 200 KVAR by replacing the all defective components with new components, re-wiring, cleaning, testing, reconnecting, re-installing and commissioning the APFC panel board complete all as specified and directed |
| 83 | All as per item 74 here-in-before but APFC panel board ranging from 100 - 150 KVAR.. |
| 84 | All as per item 74 here-in-before but APFC panel board ranging from 50 - 100 KVAR.. NOTE FOR ITEM No - 74 to 76 :- Supply of cable lugs and cable tags are deemed to be included in the quoted rates. |
| 85 | Supply & Fix Plastic body Instrument Cooling axial fan of 120 x 120 x 38 mm size fitted complete within the panel including cutting of a suitable sized hole on the panel body and wiring with 1.5 Sqmm copper conductor cable and MCB SPN 6 Amps all complete including disconnecting and dismantling the old one as per satisfaction of Engr-in-Charge. |
| 86 | Dismantling old unserviceable cable ducts from within the panel and Supply & Fix PVC cable ducts of size 45x30 MM including drawing existing cable through the ducts and commissioning the panel all as directed and specified |
| 87 | Dismantling old unserviceable DIN Rails from within the paneland Supply & Fix DIN Rail for mounting of MCBs of rating 6 to 63 Amps and of poles - 2/3/4 all as directed and specified |
| 88 | Repairs, servicing and maintenence of synchronizing panel as under :-(i). Ensuring the switching OFF operation of the Main power supply DG set to be start autometically and vice-versa (ii). Inspection of Electrical parts - motor assy, display panel, main male-female contacts, insulating material etc.(iii) Checking operation of relays.(iv). Checking/repairing/rectification of the control wiring. (v). Checking & updating all mech + electrical critical settings of panel to ascertain servicieability and spare parts found defective to be replaced for smooth functioning as directed by Engr-in-Charge.(vi). Labour only for chamber, cleaning of entire dust in side the control panel by using dry air pressure, inspect the CT\"s wiring, bus-bar joints & tightening if required |
| 89 | Supply & fix of display panel of Syncronizing panel ( CAT No-2711R-T4T SER A) all as specified and directed |
| 90 | Supply & fix in repairs 63 A TP MCB, 10 kA \"C\" series, 240 V AC, 50 Hz complete switch gear/components in various APFC panels all as specified and directed |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy