| 1 | Taking down and Re-Fixing of street light fitting of any size and capacity with MS clamp & GI bracket & connecting complete including junction box all as directed and directed. |
| 2 | Supply & fix in replacement of weather proof, PVC insulated, PVC sheathed, cable, with multistrandard aluminium conductor of size 2.5 Sqmm, 2 core, fixed from Junction box to street light fittings complete all as specified and directed. |
| 3 | S&F in replacement of 25 mm dia heavy duty, rigid non metallic PVC conduit inclusive of fittings etc fixed on pole with mild steel clamps, nuts and bolts complete. |
| 4 | Taking down old U/S bracket, clamp of any size from pole all as specified and directed by Engineer in charge |
| 5 | S&F street light bracket fabricated from 40 mm bore galvanised iron tubing light grade, 1.5 metre long, bent to shape fixed on pole / bldg including mild steel flat iron clamps, nuts, bolts etc complete all as specified and directed. |
| 6 | Material & labour for CrossArms, bracings, supports, clamps, back plate eye hook and back plates fabricated from mild steel sections including pole clamps stay clamps, D clamps nuts, bolts , washers welding bending cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat ofaluminiumpaint complete all as specified and directed. |
| 7 | Supply and fix in replacementjunction box of size 200 mm x 150 mm x 100 mm made of FRP with double stud hinged door locking, including MCB 06 amps-02 No with dinrail for mounting MCB including suitable connector for looping and duly sealed with rubber plugs, fixed on pole with necessary clamp, nut, bolt etc all as specified and directed. |
| 8 | Supply and laying in replacement Tubes, \"medium grad\",40mm dia,galvanised, with all fitting; laid in trenches/floor/fixing on pole / wall /tarmacetc.complete all as specified and directed. |
| 9 | Supply and errectioning in replacement prestressed concrete pole, 9.0 metres long, 102mm x152mm at top and 102mm x 289mm at bottom, class 10 all as specified and directed |
| 10 | Supply and errectioning in replacement Prestressed concrete pole, 11.0 metres long. 152mm x 152mm at top and 152mm x 260mm at bottom,class 9 all as specified and directed |
| 11 | M&L Plain cement concrete 1:4:8 type D2 (using 40 mm aggregrate) in base & foundations of electric poles, stays structs etc including necessary form work and fair finish to exposed surface without using extra cement etc complete all as specified and directed |
| 12 | M &L Plain cement concrete 1:3:6 type C2 (using 40 mm aggregrate) in base & foundations of electric poles, stays structs etc including necessary form work and fair finish to exposed surface without using extra cement etc complete all as specified and directed |
| 13 | M &L Plain cement concrete 1:2:4 type B1 (using 20 mm aggregrate) in coping of electric poles including necessary form work and fair finish to exposed surface without using extra cement etc complete all as specified and directed |
| 14 | Disconnecting & Taking out LT underground aluminium conductor of any size and core from trenches / walls / ducts, including cable covers, sand cushioning, joints, tubes, etc., complete all as specified and directed |
| 15 | Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed |
| 16 | Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 2 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed |
| 17 | Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed |
| 18 | Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed |
| 19 | Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sq. mm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed |
| 20 | Excavation in trenches not exc 1.5 m wide and n.exc 1.5 m in depthfor foundation / fixing of pole / laying of cable and pipe line etc or for man hole etc not exc 10 sqm on plan and getting out in soft / loose soil all as specified. |
| 21 | Excavation in trenches not exc 1.5 m wide andn.exc in depth beyond 1.5 mfor foundation / fixing of pole / laying of cable and pipe line etc or for man hole etc not exc 10 sqm on plan and getting out in Soft Rock/Rcc/Pcc all as specified. |
| 22 | All as per item no 20 above but depth exceeding 1.5M & not exc3.0M. |
| 23 | Returning filling in including spreading levelling, watering and well ramming in layers not exc 25 cm thick using excavated soil all as directed |
| 24 | Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point. |
| 25 | Supply & laying ISI marked & conforming toIS- 5820- 1970 unreinforcedprecast concrete cable coverClass LV , Type 1, flat, size250mmx l50mm x 40mm in trenches as protection toLT UG cable all as specified and directed by Engr-in-Charge |
| 26 | M&L for providing dry river sand as in sand cushioning to under ground PVCcable including punning down of sand in layer all as specified and directed. (Note: Work shall be executed as per clause 19.75 of standard schedule of rates part-1 (2009). For measurement purpose thickness of sand after punning down will be considered.) |
| 27 | Supply and installation, testing, commissioning, factory made, CPRI approved, outdoor type, LT Panel board, confirming to IS 5039 with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 Hz supply mounted on and including MS angle section 40 x 40 x 5 mm frame with front and back openable, double door with provision of locking arrangement dust & vermin proof , gasket, TPN bus bar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated complete including taking down old panel all as specified and directed& Consisting of the followingequipment\"s:-(a)MCCB 415 Volt 120 Amps, 4 Pole, 16KA-01 (Incoming) (b) MCCB 415 Volt 63 Amps, 4 Pole 10 KA-02 Nos (Outgoing) |
| 28 | (c) Solid copper bus bar 200 Amps for 3 Phase supply.(d)Solid copper bus bar 100 Amps for neutral. (e)Volt meter0- 500V - 01 with selector switch (f) Ammeter 0- 30 Amps - 01 with CTs & selector switch (g) timer switch of suitable capacity(h) Power Contactor 3 pole 63 amps, 2 NO + 2 NC Aux contacts, 415V, 50Hz (I) Auto mannual switch - 0 1 Nos |
| 29 | Note :-The LT Panel board shall be made ofsuitable size to accommodate the above fittings andshould be fixed 1.2 metre above ground level . QuottedRate should also include excavation , earth work and PCC work complete with testing all as specified and directed by Engineer -in-Charge. . |
| 30 | Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure. |
| 31 | Supply and laying in replacement Tubes, \"medium grad\",80mm dia,galvanised, with all fitting; laid in trenches/floor/fixing on pole / wall /tarmacetc.complete all as specified and directed. |
| 32 | Material and labourfor provision of earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt and electrode to galvanised iron strip 32x6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by galvanised iron light grade 15 mm dia pipe and GI Pipe 20 mm light grade for water filling including 15x20 mm reducer socket funnel wire mesh, RCC cover PCC chamber pit with PCC (1:3:6) type C-2 excavation and earth work, disposal of surplus spoil, to a distance not exceeding 50 mtrs all as specified and shown on electrical plate No. 5 of 1991 (Part-I)complete including disconnecting and dismantling of existing earthing all as directed. |
| 33 | M&L for Point wiring with 2.5 sqmm(22/.3mm) PVC insulated and unsheathed FRLS single core multistranded copper conductor for one power point in and including PVC CASING CAPPING size not less than 20mm, medium duty, ISI Marked to be terminated in modular metal/plastic box , modular fittings etc including 2.5 sqmm (22/.3mm ) PVC insulated and unsheathed FRLS single core multistranded copper earth continuity conductor controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified. |
| 34 | S&F Modular Socket 6A/16A - 2/3 pin combined 2 module. |
| 35 | S&F Modular switch 1 way 16A,1 module |
| 36 | Supply and fixing Heavy duty Air circulator fan metallic body size 450 mm sweep 240 V 50 Hz , 1440 RPM single phase heavy duty complete with all accessories like clamp, nuts and boltsetc as required to be mounted on any surface including wire from ceiling rose to fan, complete all as specified & directed. |
| 37 | M&L for Point wiring with 1.5 sqmm(22/.3mm) PVC insulated and unsheathed FRLS single core multistranded copper conductor for one light/fan point in and including PVC rigid non metallic concealed conduit 19/20 mm dia, medium duty, ISI Marked to be terminated in modular metal box , modular fittings etc including 1.5 sqmm (22/.3mm ) PVC insulated and unsheathed FRLS single core multistranded copper earth continuity conductor controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified. |
| 38 | S&F of flameproof, weather proof LED tube light fitting,type FLP-WP with LED 1 x 16 / 20 W including integral reflector made of aluminum alloy LM79 , with electronic driver, connector block, etc., and all accessories pre-wired and including connecting up with copper conductor cable of suitable type complete all as specified and directed. |
| 39 | S&F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V |
| 40 | S&F flame proof weather proof flood light fitting suitable for & including 70 watt LED chips and electronic driver, in cast aluminium alloy LM 79 construction, IP 65 including driver, reflector, connector block, etc., and all accessories pre-wired and including connecting up with copper conductor cable of suitable type complete. |
| 41 | Supply and fixing flame proof exhaust fan of size 305 mm (12\"\") sweep 240 V 50 Hz , 1440 RPM single phase heavy duty complete with louver shutter and flame proof wire from ceiling rose to exhaust fan, complete all as specified & directed. |
| 42 | M&L for Point wiring with 2.5 sqmm(22/.3mm) PVC insulated and unsheathed FRLS single core multistranded copper conductor for one power point in and including PVC rigid metallic concealed conduit 19/20 mm dia, medium duty, ISI Marked to be terminated in modular metal box , modular fittings etc including 2.5 sqmm (22/.3mm ) PVC insulated and unsheathed FRLS single core multistranded copper earth continuity conductor controlled by one switch and/or one regulator complete including cutting chases and repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified. |
| 43 | S&F M.C.B., single pole, 240 volts, 6 Amps to 32 Amp breaking capacity 10KA(type \"B\" Curve) |
| 44 | Supply & Fixing M.C.B. SPN, 240 Volts, 40Ampsbreaking capacity 10 KA (type B curve). |
| 45 | S & F sheet metal enclosure MCB DBSPN 12 way with 200 amps rated bus bar 240 volts double door with isolated Neutral Bar & Shrouded bus bar IP protection 43 having door earthingcomplete all as specified and directed. |
| 46 | M&L in sub main wiring with 2 single core PVCinsulated unsheathed cable, 1100v grade with FRLS PVC 6sq mm copper cable multi stranded conductordrawn through and including ISI markedPVC conduit 25 mmdia complete, fixed on walls/ceilings with PVC saddlesas per IS including of 6 sqmm diaFRLS PVC Copper cable green colour asearth wire connected to earth all as specified and directed by Engineer-in-Charge. |
| 47 | Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed |
| 48 | Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sq. mm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed |