| 1 | Dismantling and taking down the Ceiling Fan 1200 mm/1400 mm sweep or Exhaust Fan 200/300/450 mm or Wall mounting Fans 450 mm types of fan for carrying out servicing and repairs such as cleaning and application of lubricants / grease etcincluding replacement of defective spare parts and replacing consumables such as cotterpins, bolts and nuts, mounting clamps / bushes and painting of fans with two coats of synthetic enamel paintsusing sprey paintsafter filling of cavities andwriting of SM/MES NO inclding refixing of fans, connecting with twin flexible cord from ceiling roseto fan connector terminal , and testing complete all as specified Note :- (i)Sparesrequired will be measured and paid under relevant items, (ii) The rate quoted deemed to be inclusive of cost of consumables. |
| 2 | Supply only the Bearing spares suitable for ceiling fan 1200 mm/1400 mm sweep complete all as specified and directed. |
| 3 | Supply only the Steel shaft suitable for ceiling fan 1200 mm/1400 mm sweep complete all as specified and directed. |
| 4 | Supply only the Fan canopy bottam and top suitable for ceiling fan 1200 mm/1400 mm sweep complete all as specified and directed. |
| 5 | Supply only the Fan capacitor 2.5 to 4 Mfd suitable for ceiling fan 1200 mm/1400 mm sweep complete all as specified and directed. |
| 6 | Supply only theClamp for capacitor suitable for ceiling fan 1200 mm/1400 mm sweep complete all as specified and directed. |
| 7 | M&L for rewinding of ceiling fan 1200/1400 mmwith super enamelled copper winding wire of suitable gauge and applying varnish wih suitable class ofinsulatingvarnish complete with all winding materils , including testing complete to get desired speedall as specified |
| 8 | M & Lfor rewinding of Exhaustfan up to 300 mmwith super enamelled copper winding wire of suitable gauge and applying varnish wih suitable class ofinsulatingvarnish complete with all winding materils , including testing complete to get desired speedall as specified |
| 9 | M & Lfor rewinding of Exhaustfan450 mmwith super enamelled copper winding wire of suitable gauge and applying varnish wih suitable class ofinsulatingvarnish complete with all winding materils , including testing complete to get desired speedall as specified |
| 10 | M & Lfor rewinding ofwallfan up to 400 mmwith super enamelled copper winding wire of suitable gauge and applying varnish wih suitable class ofinsulatingvarnish complete with all winding materils , including testing complete to get desired speedall as specified |
| 11 | S& Fin repairs cabletwin core 1 sqmm copper conductor flexible wire for connecting the fan from ceiling rose and testing complete including taking down unsv cableall as specified |
| 12 | S& Fin repairscondenser 2.5 /3.15 Mfdmfd capacity suitabale for 1200/1400 mm ceiling fanfor any sweep/make/type and fansincluding taking down unsvcondensor all as specified |
| 13 | S& Fin repairscondenser 4Mfdmfd capacity suitabale for exhaustfan up to 450 mmfor any sweep/make/type and fansincluding taking down unsvcondensor all as specified |
| 14 | S& Fin repairsfor fan mounting clamps alongwith rubber bush reel type with bolts and nuts suitable for 1200/1400 mm sweep ceiling fans of any make / type including taking down unsvbushes/clampsall as specified |
| 15 | S& Fin repairs forcotterpins, bolts and nutscompleteincluding taking down unsv cotter pins all as specified |
| 16 | S& Fin repairs for down rod 15mmbore up to 50 cm lengthmade out of Galvanised iron, with complete provision for hanging ceiling fan including cutting/threadingprovisionat both ends and making suitable holes for inserting split pins/cotter pins including suitable check nuts and painting of fans with two coats of synthetic enamel paintsusing sprey paints completeall as specified |
| 17 | S& Fin repairs for down rod 15mmbore up to 200 cm lengthmade out of Galvanised iron, with complete provision for hanging ceiling fan including cutting/threadingprovisionat both ends and making suitable holes for inserting split pins/cotter pins including suitable check nuts and painting of fans with two coats of synthetic enamel paintsusing sprey paints completeall as specified |
| 18 | S& Fin repairslouversmade out of plastic body suitable forup to 450 mm sweepexhaust fan completeincluding taking down unsv louversall as specified |
| 19 | S& Fin repairs forfastener 4 \"suitable for fixing of exhaust fan on wall and ceiling fan on roofcompleteincluding taking down unsvfastenerall as specified |
| 20 | M & L for disconnecting electricaland water connectionfromgeyser , dismantling and taking downgeyser of capacity up to 50 ltrs and carrying out repair such as cleaning and descaling of inner tank , andservicing the geyser complete byreplacing the defective spares and accessories including replacement of plumbing accessories complete including painting of geyser with two coats of synthetic enamal paint using sprey gun and writing SM/MES No , andre- assembling,re fixing with by replacingcorroded/wornoutmountingbolts , connecting with 3 core flxible copper cable 2.5 sqmm with 15 Amp Plug top,testing completionall as specified . Note :-(i)Spares and accessories will be measure and paid under relevantitems.(ii) The rate deemed to be inclusiveof consuamble such as fixing screw, wahsersetc. |
| 21 | Supply only the Heating element 1.5/2 kw suitable for geyser of capacityup to 50 ltrs complete all as specified and directed. |
| 22 | Supply only the Inner Tank made out of stainlesssteelsuitable for geyser of capacityup to 50 ltrs complete all as specified and directed. |
| 23 | Supply only the Outer coversuitable for geyser of capacityup to 50 ltrs complete all as specified and directed. |
| 24 | Supply only the Thermostate suitable for geyser of capacityup to 50 ltrs complete all as specified and directed. |
| 25 | Supply only the Air pressure release safty valve suitable for geyser of capacityup to 50 ltrs complete all as specified and directed. |
| 26 | Supply only the Bottam cover and Top cover suitable for geyser of capacityup to 50 ltrs complete all as specified and directed. |
| 27 | Supply only the Mounting assbly for thermostate and heating elementincluding cover suitable for geyser of capacityup to 50 ltrs complete all as specified and directed. |
| 28 | Supply only the Glass wool suitable for geyser of capacityup to 50 ltrs complete all as specified and directed. |
| 29 | Supply only the PVC Hotwater flexiblepipe up to 450 mmlength suitable for geyser of capacityup to 50 ltrs complete all as specified and directed. |
| 30 | Supply only the PVC cold water flexiblepipeup to 450mm length suitable for geyser of capacityup to 50 ltrs complete all as specified and directed. |
| 31 | S&Fin repairs forHeating element1.5 KW capacity suitable for25 lts capacity geyser of any type and description including taking down unsv complete all asspecified |
| 32 | S&Fin repairs forHeating element2 KW capacity suitable for50 lts capacity geyser of any type and description including taking down unsv complete all asspecified |
| 33 | S&Fin repairs for thermostat automatic cut off with ISI mark capacity suitable for up to 50 lts capacity geyser of any type and description including taking down unsv complete all asspecified |
| 34 | S&Fin repairsforphase indicating neon lamp round type or rectangular type suitable for AC, single phase 230 volts suitable for geysers up to 50 Ltrs capacity including taking down unserviceabe complete all as speicified Note: Pair of green ad red colour lamps shall be measured as one unit. |
| 35 | S&Fin repairsfor heavy dutyconnection pipe / stainless steel connection pipe for Hot water connection 450 mm longcomplete,including taking down unserviceabe complete all as speicified |
| 36 | S&Fin repairsfor cold water Pipe , steel guarded PVC connection PTMT450mm length with self locing nut at both ends,including taking down unserviceabe complete all as speicified |
| 37 | S &F forNon return valve 15mm bore in gun metal and conforming to relevant IS specification including taking down unserviceabe complete all as speicified |
| 38 | S &F for2.5 sqmm 3 core copper falexible cableconnection for geyser to socketcompleteand including taking down of old damaged/unserviceabe complete all as speicified |
| 39 | Taking out compressor from water cooler of any make by cutting of suction and discharge lines for carrying out necessary repairs to the water cooler base such as renewal of MS angle iron , base plate, nuts , washers, bolts,rubber grooves and refixing it including painting with two coats of synthetic enemeeled paint of existing shade of 40/40 litres/Hrs capacities of water coolers all as specified and directed. |
| 40 | Taking out compressor from water cooler of any make by cutting of suction and discharge lines for carrying out necessary repairs to the water cooler base such as renewal of MS angle iron , base plate, nuts , washers, bolts,rubber grooves and refixing it including painting with two coats of synthetic enemeeled paint of existing shade of 40/80 litres/Hrs capacities of water coolers all as specified and directed. |
| 41 | Taking out compressor from water cooler of any make by cutting of suction and discharge lines for carrying out necessary repairs to the water cooler base such as renewal of MS angle iron , base plate, nuts , washers, bolts,rubber grooves and refixing it including painting with two coats of synthetic enemeeled paint of existing shadeof Upto 120 Lts capacity capacities of water coolers all as specified and directed. |
| 42 | Dismantling of unserviceable compressor of any make/model from water cooler including disconnecting suction / Discharge copper tubing andsupply & fixing new compressor(sealed unit) with nuts, bolts, rubbers grommet and washer, connecting copper tubing by welding flare nuts, detecting leak and repairs if any flushing and pressure testing by nitrogen & etc. vacuumising, charging with non CFC refrigerant gas of 40/40 ltrs/Hrs capacity water cooler of any make & Modelcomplete all as directed by Engineer-in-Charge. |
| 43 | Dismantling of unserviceable compressor of any make/model from water cooler including disconnecting suction / Discharge copper tubing andsupply & fixing new compressor(sealed unit) with nuts, bolts, rubbers grommet and washer, connecting copper tubing by welding flare nuts, detecting leak and repairs if any flushing and pressure testing by nitrogen & etc. vacuumising, charging with non CFC refrigerant gas of 40/80 ltrs/Hrs capacity water cooler of any make & Modelcomplete all as directed by Engineer-in-Charge. |
| 44 | Dismantling of unserviceable compressor of any make/model from water cooler including disconnecting suction / Discharge copper tubing andsupply & fixing new compressor(sealed unit) with nuts, bolts, rubbers grommet and washer, connecting copper tubing by welding flare nuts, detecting leak and repairs if any flushing and pressure testing by nitrogen & etc. vacuumising, charging with non CFC refrigerant gas of 120 ltrs/Hrs capacity water cooler of any make & Modelcomplete all as directed by Engineer-in-Charge. |
| 45 | Supply & fixing (in repairs) CP Brass push cock(inner or outer threaded) of 15 mm bore size completeall as directed by the Engineer-in-Charge. |
| 46 | Renewal of 32 mm PVC pipe with clip and strainer tee Elbow all as specified and directed by Engineer-in-Charge. |
| 47 | Supply & fixing (in repairs) starting relay for 40 ltrs/hr water cooler complete all as specified and directed . |
| 48 | Supply & fixing starting relay for 80 ltrs/hr water cooler complete all as specified and directed . |
| 49 | Supply & fixing starting relay for 120 ltrs/hr water cooler complete all as specified and directed . |
| 50 | Supply & fixing running capacitor(conforming to IS:2993 - 1975) AC 240 volts in plastic container of 10/15 mfd capacities complete all as specified and directed. |
| 51 | Supply & fixing running capacitor(conforming to IS:2993 - 1975) AC 240 volts in plastic container of 25 mfd capacities complete all as specified and directed. |
| 52 | Supply & fixing overload protector for 40/80 ltrs water cooler complete all as specified and directed |
| 53 | S & F wiring loom for water cooler all as directed by Engineer-in-Charge complete all as specified and directed. |
| 54 | S & F Thermostat long/short tail for water cooler all as directed by Engineer-in-Charge complete all as specified and directed . |
| 55 | Taking out defective blower motor with blade and supply & fixing new blower motor with blade AC 240 volts, 50 HZ single phase, for water cooler 40/80 ltrs complete all as specified and directed. |
| 56 | S&F of condensing coil for 40/80 ltrs water cooler of any make all as specified and directed by Engineer-in-Charge. |
| 57 | M&L for disconnecting of water cooler of 40/80 ltrs capacities from its position, taking out water from its water tank, cleaning of water tank by washing with washing powder and with fresh water externally and internally andspray painting with synthetic enamel paint of approved tint/colour to all painted surface of water cooler after preparation of old painted surfaceswithout disturbing the components & wiring etc. complete and reconnceting all as specified and directed by Engineer-in-Charge. |
| 58 | S&F in repairs water tray for water cooler of40/80 ltrs made out of stainless steel complete and connecting to draining system complete all as specified and directed. |
| 59 | Renewal of PVC inner liner of front door of 165/ 170 / 180 litres capacities of refrigerators including glass wool packing and making other petty repairs complete all as specified. |
| 60 | Renewal of PVC inner liner of front door of 286 litres/ 300 litres / 310 litreslitres capacities of refrigerators including glass wool packing and making other petty repairs complete all as specified and directed. |
| 61 | M&L for spray painting with two coats of synthetic enamel paint of approved tint/colour to outer surface of refrigerator of 165/180 litres capacities on all three outer sides after preparation of old painted surfacesandwithout disturbing the components & wiring etc. complete as specified and directed by Engineer-in-Charge. |
| 62 | M&L for spray painting with two coats of synthetic enamel paint of approved tint/colour to outer surface of refrigerator of 286 /300/310 litres capacities on all three outer sides after preparation of old painted surfacesandwithout disturbing the components & wiring etc. complete as specified and directed by Engineer-in-Charge. |
| 63 | Checking of leakage in refrigerant system ofrefrigerator of 165 / 170 / 180 litres capacities by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity all as directed by Engineer-in-Charge. |
| 64 | Checking of leakage in refrigerant system ofrefrigerator of 286 /300 / 310 litres capacities by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity all as directed by Engineer-in-Charge. |
| 65 | S&F starting relay, open type for refrigerator of capacity 165/170/180/300/310 litres all as directed by Engineer-in-Charge. |
| 66 | S & F over load protector for 1/6 HP refrigerator of capacity 165/300 /310 litres all as directed by Engineer-in-Charge. |
| 67 | S & Fthermostat defrost type for refrigerator all as directed by Engineer-in-Charge. |
| 68 | S & F thermostat non defrost type for refrigerator all as directed by Engineer-in-Charge. |
| 69 | S & F door gasketfor refrigerator of 165 / 170 / 180 litres capacities, any make all as directed by Engineer-in-Charge |
| 70 | S & F door gasketfor refrigerator of 286 /300 /310 litres capacities, any make all as directed by Engineer-in-Charge |
| 71 | Supply & fixing vegetable basket with glass suitable forrefrigerator of 165 / 170 / 180 litres capacities all as specified and directed by Engineer-in-Charge. |
| 72 | Supply & fixing vegetable basket with glass suitable forrefrigerator of 286 /300 / 310 litres capacities all as specified and directed by Engineer-in-Charge. |
| 73 | S & F defrost tray (Plastic) as per sample for 165 / 170 / 180 litres capacities of refrigerator complete all as specified and directed |
| 74 | S & F defrost tray (Plastic) as per sample for 286 /300 / 310 litres capacities of refrigerator complete all as specified and directed |
| 75 | S&F copper capallery for water cooler, refrigerator and deep freezer of any sizy / capacity complete all as specified and directed. |
| 76 | Checking of leakage in refrigerant system of deep freezer of 200 / 300 litres capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing a. nd testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity all as directed by Engineer-in-Charge. |
| 77 | S&F of Fan Motor of deep freezer, 230Volts rating, AC, Single Phase, 50 Hzincluding disconnection and reconnecting and testing complete all as specified |
| 78 | Renewal of Door gasket of deep freezer of any make of following capacities 300/310 litres complete all as specified and directed. |
| 79 | Supply and fixingstarting capacitor of 80-120 Mfd capacity in plastic /metal container all as directed. |
| 80 | Supply and fixingstarting capacitor of 120-150 Mfd capacity in plastic /metal container all as directed. |
| 81 | Supply and fixingrunning capacitor 36 Mfd to 50 Mfd capacity in plastic container all as directed. |
| 82 | Supply and fixingstarting relay for 1.5TR/2 TR compressor complete all as specified and directed. |
| 83 | Supply and fixing over load protector for1.5TR/2TR compressor all as directed. |
| 84 | Supply and fixing thermostate switch for 1.5TR/2TR split AC all as directed.Make:Indfoss |
| 85 | Supply and fixing swing motorfor 1.5TR/2TR Indoor unit of any make of existing capacity all as directed. |
| 86 | Supply and fixingSwing Motor for 1.5TR/2TR window type AC of any make/model all as directed. |
| 87 | Supply and fixingreverse cycle solenoid valve in split/window type AC 1.5 /2 TR capacity with necessary extension to suction / discharge copper tubbing & toggle switch complete all as directed . |
| 88 | Supply and fixingsuction copper pipe line heavy duty 1/2\"\" dia with puff insulation and flair nuts from indoor to outdoor unit of split AC 1.5 /2 TR capacity all as specified and directed. |
| 89 | Supply and fixingsuction copper pipe line heavy duty 1/4\"\" dia with puff insulation and flair nuts from indoor to outdoor unit of split AC 1.5TR/2TR capacity all as specified and directed. |
| 90 | Supply and fixingcopper Gas filter for AC 1.5TR/2TR capacity all as specified and directed. |
| 91 | Supply and fixingPVC pipe nylon imbraided 15 mm dia for condenser water drain with clamps/ concealed in wall all as specified and directed. |
| 92 | Dismantling of defective indoor unit of 1.5 TR capacity split type AC and supply & fixing indoor unit of the same capacity with blower motor . Front grill and connecting the copper tubing by brazing detecting leak and rectifying the same and recharging with Non CFC refrigerant gas as required the unit in wall/ ceiling mounted all as specified and directed. |
| 93 | Dismantling of defective condensing unit of split type AC of 1.5 TR capacity and supply & fixing new condensing unit complete with condensing coil, coil frame , wiring kit and running capacity , relay condensing motor with blade complete all as directed. Make:AS per site requirement. |
| 94 | Material & labour for servicing of indoor and outdoor unit by means of electric blower and water under pressure cleaning & washing of condensing coil / cooling by soap solution or recommended chemical, oiling & greasing of moving parts such as blower motor etc. complete of 1.5 TR capacity window type AC all as specified and directed. |
| 95 | Material & labour for servicing of indoor and outdoor unit by means of electric blower and water under pressure cleaning & washing of condensing coil / cooling by soap solution or recommended chemical, oiling & greasing of moving parts such as blower motor etc. complete of 2 TR capacity window type AC all as specified and directed. |
| 96 | Dismantling of burnt blower motor of 1.5 TR split AC (indoor unit) and supply & fixing blower motor of same manufacturer of AC of make of AC Carrier/Voltas /Blue star as per sample complete all as specifiedand directed. |
| 97 | Supply and charging (Top up) the AC unit of 1.5 TR/ 2 TR split type AC unit with Refrigeration Gas non CFC compatible to R-22/R-32in required Qty complete all as specified and directed. |
| 98 | Supply and fixingof suction valve size 1/2\" complete all as specified and directed. |
| 99 | Supply and fixingof discharge valve size 1/4\"\" complete all as specified and directed. |
| 100 | Supply and fixingof rubber coupling mounting for blower motor of split type AC all as per directed by EIC ( Make: - Carrier /Voltas).Make:Carrier/Voltas |
| 101 | Supply and fixingof air filter made out Nylon suitable for 1.5 TR split/window AC capacity air conditioners of any Make and model all as directed. |
| 102 | Carrying out pressure leak test of split Acs 1.5 /2.0 TR by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by wilding or brazing of cooling unit and refrigerant pipe , putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site all as specified and directed. |
| 103 | Carrying out pressure leak test of 1.5 TR window AC by Nitrogen gas pressure for detecting leak in cooling unit refrigerent pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site all as specified and directed. |
| 104 | Dismantling of defective worn out wiring of indoor unit of window/split AC of capacity 1.5 TR/2TR, Supply and fixing PCB ( Printed circuit Board) & Visual Eye demo plate remote hand set to suit/match the existing system all as specified and directed.Make:LG/Universal |
| 105 | Compressor reciprocating suitable for window type AC 1.5 TR (Original sealed unit is to supply) ofspecified make as approved by GE. |
| 106 | S&F in replacement sheet metal enclosure with metallic socket and MCB single pole 32 Amp and metallic plug top connected from mains to AC all as specified and directed . |
| 107 | S&F repairs metallic plug top of 16 Amps connected from mains to AC all as specified and directed. ( Make : Havells/ Legrand/ Hager).Make:Legrand |
| 108 | Dismantling of defective cooling coil of 1.5 TR window type AC of any make and S&F cooling coil for AC, detecting the leakage with N2 Gas , reconnecting in to the system complete all as specified and directed. |
| 109 | Dismantling of defective condensing coil of 1.5 TR window type AC of any make and S&F condensing coil for AC, detecting the leakage with N2 Gas, reconnecting in to the system complete all as specified and directed. |
| 110 | Dismantling of burnt blower motor of 1.5 TR /2 TR window AC and supply & fixing new blower motor, double shaft, 1/6 or 1/8 HP as per sample complete including making necessory electrical connection with suitable size copper conductor wire all as specified and directed. |
| 111 | Dismantling of burnt blower motor of 1.5 TR/ 2 TRsplit AC ( outdoor unit) and supply & fixing new blower motor, as per sample complete including making necessory electrical connection with suitable size cooper conductor cable all as specified and directed.Make:LG |
| 112 | Supply and fixingof aluminium blower / fan blade with alminium alloy bush, screw for window Acs complete as required at site complete all as directed. |
| 113 | Supply and fixingPVC Knob of window type AC complete all as specified and directed. |
| 114 | Supply and fixingof Selector Switch of window type AC complete all as specified and directed. |
| 115 | Supply and fixing repairs front grill quantity for window AC of 1.5 TR /2TR of Make National / Cosmo all as specified and directed. |
| 116 | Supply and fixingof PVC insulated three core stranded copper cable of size 80/20 all as specified and directed. |
| 117 | M&L for servicing of window type AC 1.5 TR/2.0 TR capacity by means of electric blower and water under pressure cleaning & washing of condensing coil/cooling coil by soap solution or recommended chemical, coiling & greasing of moving parts such as blower motor etc complete of following capacity all as specified and directed. |
| 118 | Supply and fixrefrigerant gas Non CFC equivalent to R-22/R-32 a in returnable sealed cylinder all specified and directed. |
| 119 | Collection of unserviceable voltage stabilizers of any make of 1 KVA capacities from AGE store yard & transportingit to local workshop of the contractor, dismantling the stabilizer for repairs of the defective parts/ spares & reassembling including repair of defective screws, rubber shoes, testing & painting with two coats of synthetic enamelled paint after removing old paint and repairs body etc. depositing back to MES stores yard all as directed by EIC.(Note :- Spares/ parts renewed shall be paid for separately under respective items at appropriate rates). |
| 120 | Collection of unserviceable voltage stabilizers of any make of 2 KVA capacities from AGE store yard & transportingit to local workshop of the contractor, dismantling the stabilizer for repairs of the defective parts/ spares & reassembling including repair of defective screws, rubber shoes, testing & painting with two coats of synthetic enamelled paint after removing old paint and repairs body etc. depositing back to MES stores yard all as directed by EIC.(Note :- Spares/ parts renewed shall be paid for separately under respective items at appropriate rates). |
| 121 | Collection of unserviceable voltage stabilizers of any make of 4 KVA capacities from AGE store yard & transportingit to local workshop of the contractor, dismantling the stabilizer for repairs of the defective parts/ spares & reassembling including repair of defective screws, rubber shoes, testing & painting with two coats of synthetic enamelled paint after removing old paint and repairs body etc. depositing back to MES stores yard all as directed by EIC.(Note :- Spares/ parts renewed shall be paid for separately under respective items at appropriate rates). |
| 122 | Collection of unserviceable voltage stabilizers of any make of 5 KVA capacities from AGE store yard & transportingit to local workshop of the contractor, dismantling the stabilizer for repairs of the defective parts/ spares & reassembling including repair of defective screws, rubber shoes, testing & painting with two coats of synthetic enamelled paint after removing old paint and repairs body etc. depositing back to MES stores yard all as directed by EIC.(Note :- Spares/ parts renewed shall be paid for separately under respective items at appropriate rates). |
| 123 | Supply only relay 25/30 Amps 24 Volts for 4 KVA/5KVA voltage Stabilizer all as specified and directed. (Make :- Dunmag, Eaglemen, Powerman) |
| 124 | Supply only Relay for 1KVA/2 KVA voltage Stabilizers all as specified and directed. (Make :- Dunmag, Eaglemen, Powerman) |
| 125 | Supply and fixing connector for IN-Out supply of voltage stabilizer 32 Amps with earth connection all as specified and directed. |
| 126 | Supply and fixing porcelain cutout of same size capacity as existing of 16 Amp each connection all as specified and directed. |
| 127 | Supply and fixing porcelain cutout (Kit-Kats) 32 Amps/240 volts all as specified and directed. |
| 128 | Supply and fixing indication lamp in voltage stabilizers of any capacity all as specified and directed. |
| 129 | S&F 2 Meter long conductorcable 3 core PVC insulated and sheathed 80/0.20 (2.5 sqmm) size duly fitted with 3 pin top, 20 Amps all as specified. Note: The servicing/repair of Water cooler,refrigerator ,deep freezer,AC of any make and size may required item as per existing ground size and executed at all sector under AGE charduar area. |
| 130 | Taking dwon and re fixingas per side requirementfor 1.5/2 ton Window AC after minor repair complete all as specificfied and directed by Engr-in Charge |
| 131 | Taking dwon and re fixingas per side requirementfor 1.5/2 ton SpilitAC after minor repair complete all as specificfied and directed by Engr-in Charge |