| 1 | Taking downold unserviceable flood light/street light/ Post top lantern fittings etc any type including brackets, cable and connections complete all as specified and directed. |
| 2 | Supply and fixing Post top lantern LED type 45 Watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp and connecting up with and including three core PVC insulated cppper conductor cable of2.5 Sqmm complete all as specified and directed |
| 3 | Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete and connecting up with and including three core PVC insulated copper conductor cable of2.5 Sqmm complete all as specified and directed |
| 4 | Supply and fixingLED street light fitting 90 Watt 230 volts AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and connecting up with and including three core PVC insulated copper conductor cable of2.5 Sqmm complete all as specified and directed |
| 5 | Supply and fixing LED flood light 120 watt 230 volts AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and connecting up with and including three core PVC insulated copper conductor cable of2.5 Sqmm complete all as specified and directed. |
| 6 | Supply and fixing LED flood light 210 watt 230 volts AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and connecting up with and including three core PVC insulated copper conductor cable of2.5 Sqmm complete all as specified and directed. |
| 7 | Supply and fixing House service bracketcomplete with 1.5m long G.I. pipe 40mm dia light. grade, two nos 90/45 degreebends. M.S.hook and stay or guy and fixed with 25mm x 4mm MS flat with necessary nuts, bolts, washers etc, as required and painting with two coats of synthetic enamel paint over a coat of primer and fixed to pole complete all as specified & as directed. |
| 8 | Supply and fixing 50mm bore GI pipe bracket (Light Grade) of length 1.5 mtrs bent to shape and fixed with 25mm x 4mm MS flat with necessary nuts, bolts, washers etc, as required and painting with two coats of synthetic enamel paint over a coat of primer and fixed to pole complete all as specified & as directed. |
| 9 | Supply and fixing in repair1.5 Sq.mm size three core PVC insulated cppper conductor cable offor connection from junction box to street light fittings run through pole complete all as specified and as directed. |
| 10 | Material and Labour for thermpolastic cable junction box IP 66 with metric knocknouts for cable entry and 4 way terminal of size 155mm x 210mm x 92mm having 04 Nos copper bus bar fixedon procelian insulators fixed in position with aluminum clamps of size 25mm x 3mm and necssary nuts and bolts complete all as specified and directed. |
| 11 | Material and Labour for trimming of tree branches (by taking proper shut down from Sub-Station) near LT/HT over head lines upto 3 m clearance around the line on all sides including removing from site all as required and directed. (Note : T&P and ladders will be arranged by the contractor at his own cost) |
| 12 | Repair/Servicing of Diesel Engineof any make directly coupled with alternator of 200 KVA/160 kVA capacity, draining out the existing engine oil from the bottom of the oil sump and checking the entire serviceablity system of DG set testing and commissioning the same at site complete all as specified and as directed..Note: (i)New Spares as required shall be measured and paid separately under subsequentitems as “Supply only” and cost of repairing is deemed to be inclusive in the unit rate quoted)(ii) DG set shall be checked for servicing once in 6 months or 200 hour whichever is less.(iii) Work shall be carried out through Original manufacturer or their authorized dealer. Certificate to this effect shall be produced before commencement of work.(iv) Proper record of testing shall be maintained as directed by Engg-In-Charge(v) Quoted rate is inclusive ofnecssary oiling and greasing, cotton ware, brushes etc and T&P required for the same(v) Contractor shall submit service report by authorized dealer/service centre. |
| 13 | Supply only Fuel Filter |
| 14 | Supply only Lub Oil Filter |
| 15 | Supply only Airfilter (Inner + Outer) |
| 16 | Supply only Relay Card |
| 17 | Supply onlyESU (Engine safety unit) |
| 18 | Supply onlyTemperature Sensor Device |
| 19 | Supply onlyRubber hose pipe suitable for 200 KVA DG Set |
| 20 | Repair/Servicing of Diesel Engine of any make directly coupled with alternator of 320 KVA capacity, draining out the existing engine oil from the bottom of the oil sump and checking the entire serviceablity system of DG set testing and commissioning the same at site complete all as specified and as directed..Note: (i)New Spares as required shall be measured and paid separately under subsequent items as “Supply only” and cost of repairing is deemed to be inclusive in the unit rate quoted)(ii) DG set shall be checked for servicing once in 6 months or 200 hour whichever is less (iii) Work shall be carried out through Original manufacturer or their authorized dealer. Certificate to this effect shall be produced before commencement of work(iv) Proper record of testing shall be maintained as directed by Engg-In-Charge(v) Quoted rate is inclusive ofnecssary oiling and greasing, cotton ware, brushes etc and T&P required for the same(v) Contractor shall submit service report by authorized dealer/service centre. |
| 21 | Supply only Fuel Filter |
| 22 | Supply only Lub Oil Filter |
| 23 | Supply only Airfilter (Inner + Outer) |
| 24 | Supply onlyRubber hose pipe suitable for 320 KVA DG Set |
| 25 | Repair/Servicing of Diesel Engine of any makedirectly coupled with alternator of 63/62.5 KVA capacity, draining out the existing engine oil from the bottom of the oil sump and checking the entire serviceablity system of DG set testing and commissioning the same at site complete all as specified and as directed. Note: (i) New Spares as required shall be measured and paid separately under subsequent items as “Supply only” and cost of repairing is deemed to be inclusive in the unit rate quoted)(ii) DG set shall be checked for servicing once in 6 months or 200 hour whichever is less (iii) Work shall be carried out through Original manufacturer or their authorized dealer. Certificate to this effect shall be produced before commencement of work(iv) Proper record of testing shall be maintained as directed by Engg-In-Charge(v) Quoted rate is inclusive ofnecssary oiling and greasing, cotton ware, brushes etc and T&P required for the same(v) Contractor shall submit service report by authorized dealer/service centre. |
| 26 | Supply only Fuel Filter |
| 27 | Supply only Lub Oil Filter |
| 28 | Supply only Airfilter (Inner + Outer) |
| 29 | Supply only Fuel injector of 63 KVA DG Set |
| 30 | Supply only injector claw of 63 KVA DG Set |
| 31 | Supply onlyRubber hose pipe suitable for 63 KVA DG Set |
| 32 | Repair/Servicing of Diesel Engine Make : Kirloskar,directly coupled with alternator of 140 KVA/125 KVA capacity, draining out the existing engine oil from the bottom of the oil sump and checking the entire serviceablity system of DG set testing and commissioning the same at site complete all as specified and as directed..Note: (i)New Spares as required shall be measured and paid separately under subsequent items as “Supply only” and cost of repairing is deemed to be inclusive in the unit rate quoted)(ii) DG set shall be checked for servicing once in 6 months or 200 hour whichever is less (iii) Work shall be carried out through Original manufacturer or their authorized dealer. certificate to this effect shall be produced before commencement of work(iv) Proper record of testing shall be maintained as directed by Engg-In-Charge(v) Quoted rate is inclusive ofnecssary oiling and greasing, cotton ware, brushes etc and T&P required for the same (v) Contractor shall submit service report by authorized dealer/service centre. |
| 33 | Supply only Fuel Filter |
| 34 | Supply only Lub Oil Filter |
| 35 | Supply only Airfilter (Inner + Outer) |
| 36 | Supply onlyRubber hose pipe suitable for 140 KVA DG Set |
| 37 | Disconnectingand taking down carefully defective self starter of 24 volt capacity of320/200 KVA DG Sets duly disconnectingall electrical cable connections and mechanical supports, transportingthe same to civil authorised work shop and dismantling and opening into parts of self starter for assessing the defects and damaged parts and rectifying the defects by changing the defective spares including testing the same after replacement of defective spares and bring back the self starter from workshop to site and re-install the same to its original position and reconnect all disconnected connections and mechanical supports etc. all as specified and as directed.. |
| 38 | Disconnectingand taking down carefully defective self starter of 24 volt capacity of140/125/63 KVA DG Sets duly disconnectingall electrical cable connections and mechanical supports, transportingthe same to civil authorised work shop and dismantling and opening into parts of self starter for assessing the defects and damaged parts and rectifying the defects by changing the defective spares including testing the same after replacement of defective spares and bring back the self starter from workshop to site and re-install the same to its original position and reconnect all disconnected connections and mechanical supports etc. all as specified and as directed.. |
| 39 | Disconnectingand dismantling including taking down carefullyradiator assembly from 140 KVA/125 KVADG Setfor cleaning soldering including servicing dully disconnecting all water hose and other mechanical supports, transporting the radiator assembly towork shop, opening into parts cleaning the radiator fans with cleaning such as cotton waste cotton rags andsoda water etc.soldering/brazing the broken/leakage fins and reassembling the same after replacement of defective spares and transportingthe same from workshop to site and mounting its to original position includingtesting etc. complete all as directed. |
| 40 | Supply only Engine Oil suitable for DGSet (K-Oil 15W/40) (in 20 Ltrs Container) complete all as specified and as directed. |
| 41 | Supply only Engine Oil suitable for DGSet (K-Oil20W/40) (in 20 Ltrs Container) complete all as specified and as directed. |
| 42 | Supply only Coolentsuitable for DGSet(in 5 Ltrs Container) complete all as specified and as directed. |
| 43 | Supply only distilled water in 1Ltr packed bottle suitable for batterycomplete all as specified and directed. |
| 44 | Supply only brass battery terminals (Set of two) complete all as specified and as directed. |
| 45 | Disconnecting and dismantling including taking down carefully injector pump for 140/125/63KVA DG Set for calibration and setting, and reassemble same after calibrationand setting and mounting it to original position including complete testing etc. complete all as specified and as directed.(Note:- Cost of transporation & any minor parts requiredis deemed to included in the Unit Rate) |
| 46 | Disconnecting and dismantling including taking down carefully injector pump for 320/200KVA DG Set for calibration and setting, and reassemble same after calibrationand setting and mounting it to original position including complete testing etc. complete all as specified and as directed.(Note:- Cost of transporation & any minor parts requiredis deemed to included in the Unit Rate) |
| 47 | Disconnectingelectrically and opening AMF Panel of140/125/63 KVA capacity DG Sets and checking all electrical cable connection and power contactors, programming of microprocessor panel, cleaning of contactors, replacement of fuse etc, andrectifying the other defects complete andrefixing the same after duly repair and replacement of unserviceablecomponents/parts and testing of panel after reparing complete all as specified and directed. |
| 48 | Disconnectingelectrically and opening AMF Panel of 320/200 KVA capacity DG Sets and checking all electrical cable connection and power contactorsprogramming of microprocessor panel, cleaning of contactors, replacement of fuse etc, andrectifying the other defects complete andrefixing the same after repair and replacement of unserviceablecomponents/parts and testing of panel after reparing complete all as specified and directed. |
| 49 | Supply and fix battery, 12 Volts,AH-180, plate -25, suitable for DG Setincluding initial charging complete all as specified and directed. |
| 50 | Supply and fixing of Power contactor 200 Amps 4 Pole with dust cover complete all as specified and as directed. |
| 51 | Supply and fixing of Power contactor 250 Amps 4 Pole with dust cover complete all as specified and as directed. |
| 52 | Supply and fixing of Power contactor 315 Amps 4 Pole with dust cover complete all as specified and as directed. |
| 53 | Supply and fixing of Power contactor 500 Amps 4 Pole with dust cover complete all as specified and as directed. |