Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 14-09-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 21-09-2024 |
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying cables, poles, stay etc and getting out in soft and loose soil all as specified & directed by Engineer-in-Charge. |
| 2 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc.25cm thick each layer of soil all as specified. |
| 3 | Removal of excavated material to distance not exceeding 250 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point in soil, complete all as specified and directed. |
| 4 | Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified & directed. |
| 5 | Demolition of brick work, stone/ bouldermasonry and built in cement mortar including all quoins arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articlesall as specified & directed |
| 6 | Brick work with sub class ‘B’ bricks of old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed. |
| 7 | Brick work with sub class ‘B’ bricks , old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified & directed. |
| 8 | Hard core ofbroken stone or boulders of gauge n.exc. 63mm, deposited, spread and leveled in layers n.exc. 15cm thick, watered and rammed to a true surface complete all as specified & directed. |
| 9 | Reinforced cement concrete type A-1, 1:1½:3(nominal mix, using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams etc, shelves and the like complete all as specified and directed (reinforcement shall be measured and paid for separately). |
| 10 | Reinforced cement concrete type A-1, 1:1½:3(nominal mix, using 20mm graded crushed stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed (reinforcement shall be measured and paid for separately). |
| 11 | Reinforced cement concrete,type A-1, 1:1½:3(nominal mix, using 20mm graded crushed stone aggregate)as in coloumns, pillars etc complete all as specified and directed (reinforcement shall be measured and paid for separately). |
| 12 | Reinforced cement concrete,type A-1, 1:1½:3(nominal mix, using 20mm graded crushed stone aggregate) as in beams, cantilevers , bressumers,lintels over 1.5m span, all as specified and directed . (reinforcement shall be measured and paid for separately). |
| 13 | Form work to sides of pillars, coloumns and similar items (square, rectangular or polygonal) including edges rough finished surface of concrete flat complete all as specified and directed. |
| 14 | Form work to flat surfaces of suspended slabs such as roof slab, floor slab, landing, shelves etc not exceeding 200mm thick,including edges in any position, rough finished surfaces, complete all as specified and directed. |
| 15 | Form Work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter to give rough finish to flat surfaces complete all as specified and directed. |
| 16 | Material and labour for mild steel TMT bars 10mm dia & over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Engineer-in-Charge. |
| 17 | Mild steel TMT bars 6mm to 8mm dia and over upto and including 10mm dia, cut to length, bent to shape required, including cranking, bendingspirally including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips as in stirrups, spacers and binders , all as specified. |
| 18 | Powder coated aluminum sections as inframes/ shutter of doors/window/ventilators /partitions,(Sliding / openable/ three track)including joinging cleats, glazing clips, rubber neoprene beading, powder coated aluminim snap beading, screws etc. complete all as specified and directedNote : (i) Minimum thickness of power coating shall not be less than 50 micron.(ii) Weight of aluminum section only shall be measuerd and paid.(iii) Aluminum doors/windows /ventilators to be fixed to jambs with chromium plated screws .(iv) The rate shall be inclusive of neoprene beadings, snap beading, screws etc and in case of sliding shutters locking arrangement and rollers in sliding shutters. Weight of fitting fixtures will not be measured for arriving the weight of aluminum section.(v) Glass /wooden panel/ACP sheet shall be measured and paid separately under respective items.(vi) Design as directed by Engineer in charge. |
| 19 | 5.00mm thick ordinary quality tinted glass,fixed to aluminum frame work ,in panelsexc 0.5 Sqm in each pane, complete all as specified & directed. |
| 20 | 10mm thick toughned glass partition with door, fixed with suitable size of hinges & handles , toughned glass fixed in groove of wall / floors with silicon filling including stainless steel clips and other necessary fixing arragements as reuired at site, complete all as specified and directed. |
| 21 | Dismantling floor hearth or wall tilling including cement mortar bedding, complete as specified and directed. |
| 22 | Glazed ceramic coloured tiles thickness not less than 7mm thick area of each tile exc 0.13 sqm but not exceeding 0.27 sqm, in skirting , dado etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 15 mm thick bedding layer in cement mortar 1:4, complete all as specified and directed. |
| 23 | Non skid ceramic coloured tiles7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but not exceeding 0.18 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 15 mm thick bedding layer in cement mortar 1:6, complete all as specified and directed. |
| 24 | Coloured vitrified ceramic tiles, light shade,8-10mm thick (square ) , area of each tiles n.exc 0.36sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over15mm thick screed bed in cement mortar 1:6, complete all as specified and directed. |
| 25 | 25mm thick Plain cement concrete 1:2:4 type B-0 using 12.5mm graded aggregate as in sub base complete all as specified & directed. |
| 26 | Galvanized MS wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm, complete all as specified and directed. |
| 27 | 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) double layered, screwable lid, hoisted and fixed in position, including tank nipple, float valve, ball valve 20mm PTMT, all as specified in SSR Part-I and all as directed by Engineer-in-charge. |
| 28 | 15 mm bore Galvanized Steel tubes, medium grade including all fittings for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors , complete all as specified and directed. |
| 29 | 20 mm bore Galvanized Steel tubes, medium grade including all fittings for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floorscomplete all as specified and directed. |
| 30 | Cuttingchases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings etc and cutting chases for concealed water tubing & making good, cutting not exc 10 cm girth, in brick walls complete all as specified and directed. |
| 31 | Wash hand basin, vitreous china, wall hung with fixing accessories, white, ofsize570x470x190mm,with pedastal of height 850mm, complete all as specified and directed. Make : Jaguar Cat Part ARS-WHT-39801 or equivalent as approved in Appx \"C\" |
| 32 | Single lever extended basin mixer, without Popup waste and 450mm Long Braided Hoses, cast copper alloy, cast copper alloy chromium plated, screwed for iron pipe or for union, suitable for 15mm bore pipe, complete all as specified and directed.Make : Jaguar Cat Part ARI-39001B or equivalent as approved in Appx \"C\" |
| 33 | Single Piece WC with UF Soft Close Slim Seat Cover, Hinges, Dual Flush Cistern Fitting, Fixing Accessories, Size: 370x670x720 mm, S Trap- 220 mm, fixed in position, complete all as specified and directed. Make : Jaguar Cat PartLYS-WHT-38851S220UFSMN or equivalent as approved in Appx \"C\" |
| 34 | Beveled edge looking mirror, 5.5mm thick of selected quality glass, including wood finish PVC mouldingmounted on 6mm thick ply or of PVC frame fixed to wall with screw and rawl plugs, complete all as specified and directed. |
| 35 | Wall mixer , with provision for overhead shower complete with 115mm long bend pipe on upper side connecting leg and wall flange,chromium plated suitable for 15mm bore GI pipe or union,complete all as specified and directed. Make : Jaguar Cat Part FUS-29273UPR or equivalent as approved in Appx \"C\" |
| 36 | 25mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed. |
| 37 | 127mm dia chromium plated grating, with waste hole complete all as specified and directed. |
| 38 | Hand Shower (Health Faucet) with 8mm Dia, 1.2 Meter Long Flexible Tube & Wall Hook with N.R.V (Back Flow Preventer), fixed in position, complete all as specified and directed. Make : Jaguar Cat Part ALD-577 or equivalent as approved in Appx \"C\" |
| 39 | Brass chromium plated, tubular towel rail 20 mm dia. ‘D’ type, 60 cm long between flanges including brackets, complete all as specified and directed. Make : Jaguar Cat Part CAN-1111SM or equivalent as approved in Appx \"C\" |
| 40 | Bib taps brass, with wall flange, chromium plated, cast copper alloy fancy type, short body, screwed down for iron pipe or for brass ferrule, suitable for 15mm bore pipe,complete all as specified and directed. |
| 41 | PVC connection 15mm size with PTMT nuts of length 450mm longcomplete all as specified and directed. |
| 42 | Glass shelf of size 500 x 125mm Chromium plated fixed with chromium plated steel screws and plastic cleats,complete all as specified and directed. |
| 43 | Corner glass shelf 200mm Chromium plated with brass brackets, complete all as specified and directed. |
| 44 | Rendering 10mm thick in cement plaster in cement and sand mortar 1:3 over brick work or concrete surfaces of ceiling, finished even and smooth without using extra cement ,complete all as specified & directed. |
| 45 | Three coats of white wash on ceiling surfaces including preparation of new plastered surfaces complete all as specified and directed |
| 46 | Taking down existing plaster of any description on brick wall/ concrete surface including racking out joints, hacking for key, scrubbing down with water etc complete, all as specified and directed. |
| 47 | 15mm thick rendering in Cement and Sand mortar 1:6 over concrete /brick surfaces, in patches,finished even and smooth without using extra cement complete all as specified & directed. |
| 48 | 15mm thick rendering in Cement and Sand mortar 1:4 over concrete /brick surfaces, in patches,finished even and smooth without using extra cementand providing necessary scaffolding , safety precautions and other requisite arrangements all as per site requirement complete all as specified & directed. |
| 49 | Preparation of new plastered or unplastered surfaces of walls, applying wall care putty in two coats over a coat of alkali – resistant cement based primer andapplying two coats of interior acrylic emulsion paint complete all as specified and directed. |
| 50 | Preparation of new plastered or unplastered surfaces of walls, applying wall care putty in two coats over a coat of alkali – resistant cement based primer andapplying two coats of weather proof exterior acrylic emulsion paint complete all as specified and directed. |
| 51 | Preparation of old plastered or unplastered surfaces of walls by completely removing existing treatment, applying wall care putty in two coats over a coat of alkali – resistant cement based primer andapplying two coats of interior acrylic emulsion paint complete all as specified and directed. |
| 52 | Complete removal of existing treatment and preparation of old plastered or unplastered surfaces of walls including filling with Birla white putty and applying two coats of plastic emulsion paint over a coat of primer complete all as specified and directed. |
| 53 | Chromium plated, fancy type, over head shower200mm x200mm square shape single flow (ABS body chrome plated with grey face plate) with Rubit cleaning system shower rose with shower arm 400 x25x25mm square shape, complete all as specified and directed. Make : Jaguar Cat Part OHS-35497 & SHA-455L400 or equivalent as approved in Appx \"C\" |
| 54 | PVC(SWR) rain water pipe, 110mm bore, single socketed in any length with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mmincluding nuts bolts etc,complete all as specified and directed. |
| 55 | PVC(SWR) rain water pipe, 75mm bore, single socketed in any length with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mmincluding nuts bolts etc,complete all as specified and directed. |
| 56 | PVC(SWR) rain water pipe, 110mm bore, single socketed in any length with rubber ring joints, laid in trenches or in floors,complete all as specified and directed. |
| 57 | PVC(SWR) rain water pipe, 75mm bore, single socketed in any length with rubber ring joints, laid in trenches or in floors,complete all as specified and directed. |
| 58 | 110mm bore PVC (SWR) bend any radius complete all as specified and directed. |
| 59 | 75mm bore PVC (SWR) bend any radius complete all as specified and directed. |
| 60 | Plain cement concrete type C-2, 1:3:6 using 40mm graded crushed stone aggregate as in bed to drain pipes including cradle of 150mm bore pipe after the pipes are laid and tested , complete all as specified and directed. |
| 61 | Salt glazed stoneware drain pipe grade ‘A’ 150mm bore, ISI marked, jointed with cement mortar, laid in trenches and tested including fittings of same grade complete all as specified and directed. |
| 62 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in plain cement concrete 1:2:4 type B1 smooth finished,and reforming benching as required,internal dia of pipe 150mm all as specified and directed. |
| 63 | Granite stone slabs, 16 to 18mm thick,width and length as per site requirement, best qualitymachine cut andpolished to be fixed infloors,cooking plateform, tread, raiser of steps and vertical surfaces etc and jointed with gray cement slurry and pointed in white cement mixed with marble dust (1:2) with admixture of pigment to match the shade of slab, rubbing, cutting / rounding of edgesand corners where required with and including 15 mm thick screed bed in cement mortar 1:4, Complete all as specified and directed. |
| 64 | 4mm thick False ceiling fibre cement board, white in colour , 595mm x 595mm in size, fire and moisture resistance, fixed with and including standard GI snap grid framing (Powder coated) and suspended not exceeding 900mm below from ceiling with 3mm dia wire including clips and misc fittings etc in pattern as approved by GE, fixed as in repair (size of panel shall be of 605 x 605mm and GI snap grid framing shall be of 1mm thick standard section i.e. channels, angles, tee etc),complete all as specified and directed. |
| 65 | Louvers wall panels with thickness not less10mm thick and not less than 250mm wide interlocking type system as in wall / ceiling linings including end and intermediet U or L PVC sections as per mnufacturer instructions complete all as specified and directed.Note : Colour / design and pattern as approved by Enginee-in-Charge. |
| 66 | Plain cement concretetype C-1, 1:3:6 (using 20 mm graded stone aggregate) as in levelling course, sub base and roof padding, complete all as specified and directed. |
| 67 | Rendering 15mm thick (average thickness) plaster in cement mortar 1:4 mixed with WPCon concrete roof/ wallsurfaces including flashings and junction of parapets etc ,finishing the surface even and fair without using extra cement all as specified and directed by Engineer-in-charge. |
| 68 | 3mm thick Atactic polypropylene polymer (APP) based polymeric membrane minimum weighing 3.6kg/sqm andreinforced with polyester non woven fabric (weight not less than 150 gm/sqm) laid over a coat of bitumen primer @0.40L/Sqm by same membrane manufacturer of density 0.87 to 0.89 kg/L at 25° C temperature and viscosity 70 to 160 CPS, over primer coat bonding material of blown bitumen 85/25 grade heated to working temperature of 180° C applied @1.2Kg/Sqm. The membrane shall be laid using butane torch and sealing all joints etc after preparing the surface as per standard practice and as per manufacturer instructions complete all as specified & directed. |
| 69 | Providing cement concrete type B-0, 1:2:4 using 12.5mm graded stone aggregate as on roof kerb grounded or chamfered admixing Fosroc Conplast WL @ 125ml per 50 Kg cement bag complete all as specified and directed. |
| 70 | Precast cement concrete louvres and jallies, 40mm thick (measured solid) type B0(12.5mm aggregate) set in cement mortar (1:4), including all mouldings but excluding frame, fixed in repairs ,complete all as specified & directed. |
| 71 | Providing reinforced cement concrete type B-l, 1:2:4 (20 mm graded aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area exc 100 sqcm, but n.exc 250 sqcmwith or without chamfered angles and flat, splayed, rounded or mitred tops complete all as specified & directed. |
| 72 | Steel work in tubular trusses and tubular posts including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 t complete all as specified & directed by Engineer-in-Charge |
| 73 | Toilet paper holder, cast copper alloy, chromium plated,complete all as specified and directed. |
| 74 | Taking down carefully aluminum/copper point wiring on & including hard wood battens, surface conduit and board/blocks etc or through conduits for light , socketor power point ,fan point complete incl fitting such as switches ,sockets, ceiling rose , holder socket, light fitting, regulators and making good disturbed surfaces of wall, floor , ceiling etc and removing materials (other than those for which credit has been given by the contractor) to the MES stores yard for keeping in safe custody complete all as specified and directed. |
| 75 | Material and labour forpoint wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including provn ofnew modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising ofOne light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note for serial item No 2 & 6 : Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original and nothing extra shall be paid on this account. |
| 76 | All as per serial item 75 herein before but for socket outlet 3 pin 5 Amps on same board complete all as specified and directed |
| 77 | All as per serial item 75 herein before but for socket outlet 3 pin 6 Amps on independentboard complete all as specified and directed |
| 78 | All as per serial item 75 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSHcable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor |
| 79 | Switch modular type (ISI marked), single pole, one way 6 Amps, one module(ISI marked), complete all as specified & directed. |
| 80 | Switch modular type (ISI marked), single pole, two way 6 Amps, one module(ISI marked), complete all as specified & directed. |
| 81 | Switch modular type (ISI marked), single pole, one way 16 Amps, one module(ISI marked), complete all as specified & directed. |
| 82 | Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose two module (ISI marked), complete all as specified & directed. |
| 83 | Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed. |
| 84 | Modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed. |
| 85 | Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specifiedand directed by Engineer-in-charge. |
| 86 | Lamp holder, PVC/Polycarbonate type with back plate modular type fixed on wall suitable for batten fitting ,complete all as specified and directed. |
| 87 | LED lamp9 watts, B-22 type complete all as specified . |
| 88 | Disconnecting the power supplyand taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCB\"s ,MCB\"s etcand removing from site, Complete all as specified and directed . |
| 89 | MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 08 way SPN with 200 Amps busbar 240V completed all as specified and directed. |
| 90 | Sheet metal enclosureSPN with two pin and earth plug and socket complete with one single pole MCB 20 Ampcompleted all as specified and directed. |
| 91 | MCB, SPN , 240 volt,40 to 63Amps, 10 KA , \"C\" series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 92 | MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , \"C\" series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 93 | MCB, SP , 240 volt,40Amps, 10 KA , \"B\" series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 94 | LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable sizefixed as in repair complete all as specified and directed. |
| 95 | Slim LED lights fitting, 4 feet,1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed. |
| 96 | Slim LED lights fitting, 2 feet,1x 10W, inverter rechargeable,220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed. |
| 97 | Taking down carefully old copper or aluminium sub main wiring of any Nos of wiring and size with earth wire on wooden batten/ surface conduit/ casing- capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified and directed. |
| 98 | Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 4 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 4 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.Note : (i)For the purpose of measurement, 2 single core of 4 sqmm and one single core earth cable of 4 sqmm cableshall be considered as 1 running metre. (ii) Cutting chases will be measured and paid separtely(iii) colour code shall be Red for phase, Black for neutral and green for earth |
| 99 | Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 6 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 6 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.Note : (i)For the purpose of measurement, 2 single core of 6 sqmm and one single core earth cable of 6 sqmm cableshall be considered as 1 running metre. (ii) Cutting chases will be measured and paid separtely(iii) colour code shall be Red for phase, Black for neutral and green for earth |
| 100 | Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth Complete all as specified and directed . |
| 101 | LED panel surface mounted -2\"x2\" - 36 wattscool day light fitting with heat exchanger unit, LED driver, surge protection complete including cutting hole of required size in POP/false ceiling making good disturbed including taking down any type ceiling fittingcomplee all as specified and directed. |
| 102 | LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,includinglamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, fixed as in repaircomplete all as specified and directed. |
| 103 | Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and directed. |
| 104 | Cutting openings, through brick walls in round shape , for 300mm dia exhaust fan and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required including finishing and matching the disturbed surface and removing surplus unserviceable bricks, hard-core, etc..from site and rubbish complete all as specified & directed by Engineer-in-charge. |
| 105 | Supplying, installing and commissioning of split type air conditionerwith coolingfunction EER 3.2 of capacity 2TR, 04 star rated with cordless remote control unit and in built air ioniser, plasma filter for better indoor air quality, 03 star rated suitable for wall mounted, single phase, 230/250 volt AC including breaking necessary hole in wall for fixing indoor and outdoor unit and making good to disturbed surfaces with cement mortar to match with existing finishes after commissioning,PVC pipe medium duty 25 mm dia for draining out condensed water,all as required including necessary electric connections, complete all as specified and directed.Note :- (i) Quoted rates shall deem to include the cost ofdrain pipe, copper tubing of requisite length and 4 sqmm multi standard copper cable, brackets, etc.(ii)Installation and commissioning to be done through OEM / itsauthorised service centre / agency. |
| 106 | Supply and installed voltage stabilizer automatic digital display type, single phase naturally air cooled indoor type & designed for input variation between 170V to 250 Volt with output voltage stabilized at 230 Volt +/- 2.5% of capacity 4.0 KVA complete all as specified and directed. |
| 107 | Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed. Note(s) :-(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.(ii)PCC chamber shall be constructed 500 mm away from the edge of earth pit.(iii) Rate shall include earth lead and protection pipe of length 7.5m(iv)Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.(v) unit rate including protection pipe and GI wire 4.00mm dia from top to earth plate upto 7.5 meter |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy