| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil all as specified and as directed. |
| 2 | Returning filling in excavated soil upto a depth of 30 cm after riddling of excavated soil (in lieu of sand) for cushioning of cable and refilling of trenches with left over normal excavated soil including spreading, leveling, watering and well ramming in layers complete all as specified and as directed by Engr-in-Charge. |
| 3 | Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed. |
| 4 | Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 flat, size 250 mm x 150mm x 40mm all as specified and as directed. |
| 5 | M&L for Plain Cement Concrete 1:4:8 type D2 (using 40mm graded stone aggregate) in foundation complete all as specified and directed by Eng-in-cahrge. |
| 6 | M&L for Plain Cement Concrete 1:3:6 type C1 (using 20mm graded stone aggregate) for stay and coping for poles including necessary form work and exposed surface finished smooth and even complete all as specified and directed. |
| 7 | M & L for Steel tubular swaged poles 9 meter long complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 including two coats of silver painting over a coat of red oxide primer complete all as directed by Eng-in-Charge. |
| 8 | Supply and laying in trenches, LT underground cable, XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross sectional area 6 Sqmm, 2 core multistranded including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as specified and directed. |
| 9 | All as per item No 8here-in-before but cross sectional area 10 Sqmm, 4 Core. |
| 10 | All same as per item No 8 here-in-before but cross sectional area 16 Sqmm, 4 Core. |
| 11 | All same as per item No 8 here-in-before but cross sectional area 25 Sqmm, 3.5 Core.Note to item No. 8 to 11 : Necessary excavation shall be measured and paid separately. |
| 12 | M&L for preparing of old faded paint surface and painting with one coat of synthetic enamel paint to existing LT PCC/RCC/Steel tubular poles of size 9 m long up to the height of 1.2 m from the bottom with approved white and blue colour alternatively including pole number with paint same as existing earlier complete all as directed by Eng-in-Charge. |
| 13 | M&L for preparing of old faded painted surface of 9 m long steel tubular pole complete including all accessories such as cross arms, bracings, brackets etc and painitng with two coats of aluminium paint of approved make including writing pole number with paint same as existing earlier complete all as directed by Eng-in-Charge. |
| 14 | Supply and fix in repair LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as specified and directed by Eng-in-Charge. |
| 15 | All as per item No 14 here-in-before but capacity 60 Watt. |
| 16 | All as per item No 14 here-in-before but capacity 72 Watt. |
| 17 | All as per item No 14 here-in-before but capacity 90 Watt. |
| 18 | Supply and fix in repair energy saving rectangular LED flood light fitting 150 Watts, 240 volts AC, cool white colour, CCT5700°K, CRI>70, THD<10%, system lumens not less than 100lumens/watt with innovative thermal management, available with multiple optics, equipped with IP-66 protection, 5 KV surge protection, aluminium die cast housing, life of luminaires should not be less than 50000 burning hours and suitable for large area lighting including fixing on High mast pole/Buildings/TARMAC poles etc. by means of clamps, nuts, bolts and any other accessories complete all as specified and as directed by Engr-in-Charge. |
| 19 | All as per item No 18 here-in-before but capacity 200 Watts. |
| 20 | All as per item No 18 here-in-before but capacity 250 Watts. |
| 21 | Repair and maintenance of all type Street/Security light fittings 45/60/70/90 watt capacity and flood light fittings 150/170/200/250 watt, solar street light fittings 10/12 watt capacity including cleaning of perplex cover where ever required and tightening of loose connection or brought it down for repair and fix it back after repair on the same pole/place all as specified and directed. |
| 22 | Supply and fix in repair of terminal box made out of SMC with hinged door and locking arrangements of size 140x140x95mm Including ,Backlite 4 way connector,M S Clamps suitable for pole ,PCC/MS/GI/rail etc. with bolt, nut and washer,electrical connections including MCB SP 6-32 Amps complete all as specified and as directed by Engr-in-Charge. |
| 23 | Supply and fix in repair of terminal box made out of SMC with hinged door and locking arrangements of size 200x140x95mm Including ,Backlite 4 way connector,M S Clamps suitable for pole ,PCC/MS/GI/rail etc. with bolt, nut and washer,electrical connections including MCB SP 6-32 Amps complete all as specified and as directed directed by Engr-in-Charge. |
| 24 | S&F in repair pole mounted junction box (Street light box) made out of SMC sliding type doors fits to base by 3 phase busbar insulator - 04 Nosfor street lighting system with nuts and bolts with fixing arrangment outdoor type of dimension 240 x 130 x 110 mmforwith suitable screen printed skull and bones for danger notice on middle and top cover of the box complete all as directed by Eng-in-Charge. |
| 25 | Supply and fix in repair three single core PVC insulated and sheathed copper conductor cable 2.5 Sqmm nominal size and one single corePVC insulated and sheathed copper conductor cable 2.5 Sqmm nominal size for earth continuity from main lines to the street light fittings after removing u/s onecomplete all as directed by Eng-in-Charge. |
| 26 | Supply and in repair three core PVCcable, FRLSwith copper conductor round cable of size 1.5 Sqmm for connection from juction box to street light fittings complete all as directed by Eng-in-Charge. |
| 27 | Supply and fix in repair 415V 10KA \"B\" curve miniature circuit breaker (MCB) of 40 to 100 Amps rating triple pole and neutral in the DB complete with connection testing and commissioning all as specified and directed by Engr-in-charge. |
| 28 | Supply and fix in repair 415V 10KA \"C\" curve miniature circuit breaker (MCB) of 40 to 100 Amps rating triple pole and neutral in the DB complete with connection testing and commissioning all as specified and directed by Engr-in-charge. |
| 29 | Supply and fixing in repair 230V 10KA \"C\" curve miniature circuit breaker (MCB) of 6 to 32 Amps rating single pole in the Junction box/DB complete with connection testing and commissioning all as specified and directed by Engr-in-charge. |
| 30 | M & L for boring of holes under roof, pavement, hardstanding by trenchless technology using ultrasound technique and necessary machine including provision of HDPE pipe of 75mm dia suitable for 0.4mpa working pressure complete all as specified and directed by Eng-in-Charge. |
| 31 | Supply & lay GI tubing light grade 50 mm bore in trenches/fixing on pole/wall/crossing in drain etc. for protection of UG cablecomplete all as directed by Eng-in-Charge. |
| 32 | Supply & lay GI tubing light grade 40 mm bore in trenches/fixing on pole/wall/crossing in drain etc. for protection of UG cablecomplete all as directed by Eng-in-Charge. |
| 33 | Supply and fix in repair driver suitable for 45 Watt LED light fittings and testing complete all as specified and directed by Engr-in-charge. |
| 34 | Supply and fix in repair driver suitable for 60 Watt LED light fittings and testing complete all as specified and directed by Engr-in-charge. |
| 35 | Supply and fix in repair driver suitable for 70/72 Watt LED light fittings and testing completecomplete all as specified and directed by Engr-in-charge. |
| 36 | Supply and fix in repair driver suitable for 90 Watt LED light fittings and testing complete all as specified and directed by Engr-in-charge. |
| 37 | Supply and fix in repair driver suitable for 120 Watt LED flood light fittings and testing complete all as specified and directed by Engr-in-charge. |
| 38 | Supply and fix in repair driver suitable for 150 Watt LED flood light fittings and testing complete all as specified and directed by Engr-in-charge. |
| 39 | Supply and fix in repair driver suitable for 200/250 Watt LED lood light fittings and testing complete all as specified and directed by Engr-in-charge. |
| 40 | Supply and fix in repairs analog time switch with battery backup, 3 pole module, 24 hours programmable every 20 min, backup of 100 hrs, current capacity 32 Amps, with 1 change over complete with connection testing and commissioning all as specified and directed by Engr-in-charge. Make : Indo Asian model 3mod DIN Daily, Cat No TA926453 or any equivalant make as mentioned in PS. |
| 41 | Supply and fix LED Aviation light luminaries Integral LED aviation light comprising of aluminium housing with polycarbonate enclosure complete all as specified and directed by Engr-in-Charge. Make - Bajaj Cat Part No. 110731 BGAV 302 LED or its equivalent in phillips/cormpton. |
| 42 | Repair/Maintenance for street light control gate ways and its accessories including recharging of postpaid SIM cards (09 Nos) for the period of 08 Months complete all as specified and directed by Engr-in-charge. |
| 43 | Dismantling and taking down the complete high mast tower 16 to 20 mtr height by removing bolts and nuts at the bottomwith the help of crane/motor andremoving the worn out /cut stainless steel GI wire unservicable pulley,shafts checknuts etc includingfixing new spares,applying grease, checking and rectifying mechanical and electricalconnections and re-erecting the same after making functional of all componentscomplete all as specified and as directed by Engr-in-chargeNote:(i) NecessarySpares shall be measured and paid separately under relevant item/items of the schedule as supply only. The rate for minor spares necessary for carryingout the repair work which are all not coveredunder the schedule shall also deemed to be included the quoted rate.(ii) The rate quoted deemed to be included the rate of all manpower including technicians,crane operator etc.and all tools and plants including crane/motor required to carryout above work.(iii)The light assembly shall also be checked twice in the contract period other than the repairing time by taking down the light assembly from top to bottom and taking up to the original position (i.e. from bottom to top) after completing the repair work if any including checking the serviceability of high mast operating mechanism. |
| 44 | Supply only reverse forward switch suitable for existing high mast light tower 15 mtr to 20 Mtr heightall as specified. |
| 45 | Supply only galvanised steel wire rope 8 mm dia 30 mtr long suitable for existing high mast light tower 15 mtr to 20 Mtr height all as specified. |
| 46 | Supply only pulley for geared motor existing high mast light tower 15 mtr to 20 Mtr heightall as specified. |
| 47 | Supply only sprocket for geared motor existing high mast light tower 15 mtr to 20 Mtr heightall as specified. |
| 48 | Supply and pour gearbox oil suitable for geared motor after cleanig all geared surface of high mast gear box including draining out of old unusable oil all as specified and directed. |
| 49 | Supply and fix in repairs bolts,nuts,washers, check nuts etc. suitable for high mast light/ solar lights complete all as specified and as directed by Engr-in-Charge. |
| 50 | Supply and fix in repair copper cable of size 10 sqmm 4 core PVC insulated flexible, PVC sheathed 1100 volts including removing unserviceable cable complete all as specified and as directed by Engr-in-Charge. |
| 51 | M & L for LT panel board totally enclosed floor mounted outdoor type vermin proof,dust proof made out of 3mm thichk ms sheet of suitable size with door locking arrangement, door rubber beading duly painted with powder coated two coats of synthetic enamel paint over a coat of red oxide primer including panel wiring including necessary civil work for fixing of panel board consisting of the following items:(a) MCCB 4 pole 63 Amps, 16 KA,415 Volts, 50Hz with adjustable thermal and magnetic setting-01 No(b) MCB TPN 63 Amps 10KA, 415 Volts, C Curve - 02 Nos outgoing(c) Digital voltmeter with selector switch 0-500 Volts-01 No(d) Digital Ammeter with selector switches 0-100 Amps-01 No(e) Indicator lamps LED type (RYB)-01 Set(f) Complete internal wiring with suitable PVC insulated copper conductor cable including lugs and connections. |
| 52 | M&L for rewinding of 3 HP motor of High mast light by takingto workshop and removing cut/burnt winding and rewinding with suitable sizeof copper wire and making the motor serviceable including testing complete all as specified and as directed by Engr-in-Charge. |
| 53 | Supply and fix in repair LED Street light fitting 10/12W, DC suitable for solar street light with pressure die cast aluminium housing with heat reristant glass & IP 65 Protection better option for uniform distribution of light & including with all accessories fixing on pole/wallcomplete with necessary connection and all as specified and directed. |
| 54 | M&L for fabrication of rectangular box of size 59cmx26cmx45cm made from 2 mm thick GI sheet suitable toaccommodate solar battery including lockingarrangements, providing support at the bottomand necessary fixing arrangements to fix the box on the poleand applying two coats synthetic enamel paint over a coat of red oxide primer including write pole No as per existing and taking down old unserviceable box complete all as specified and directed. |
| 55 | M&L for replacing the unserviceable batteries of solar street light with maintenance free sealed battery of size 120 AH 12V including taking out old unservicealbe batteries all as specified and directed. |
| 56 | M&L for cleaning and washing of each solar street light panelto remove layer of dust and dirt from panels by simply wash the panel with water and rub the panel surface with a sponge. Note : (a) Do not use a metal brush or detergent to clean the solar panel surface. (b) Rates deemed to be inculded labour, water and sponge charges. |
| 57 | Supply and fixing in replacement, “Lithium based Energy Efficient Integrated Solar Street Light of 30Watt”inrust proof Aluminium housingwith Monocrystalline Solar PV Panel of 75W(-0/+4W)Mono , Lithium Battery 12.8V, 42AH(BIS Certified), IP 65, High brightness W-LED(150 Lm/watt) lamp with Aluminum reflector for better light distribution,Color Temperature 6500K +500K, Microcontroller based charge controller cum driver, automatic dimming function( with PIR Motion Sensor), Dusk to Dawn Operation, suitable to working temperature: (-) 5 degree C to (+) 45degree C,Charging time 1 day and Autonomy 2 days with dimming Protections: Short Circuit, overload, Reverse polarity and battery protections.Make:- Cromptom CSOP-816-30-57-HL5-FD-LM-SR or equalavent in Havells/ Philips/ Wipro |
| 58 | Supply and fxing in replacement of 7 meter high hot dipped octagonal poles with 130mm bottom dia & 70mm top dia made up of 3 mm thick HT Sheet alongwith base plate of size 200x200x12mm including fiundation bolts & bracket of size M20 x 600 mm EN 8 grade \"J\" type foundation bolts and numbering of poles, in white paint over black painted back ground at a height of 1.5m from bottom of pole with 5 cm large bold letters 2\" (inch) wide withetc complete as required andall as specified and directed.complete accessories as required including dismantling existing pole. |
| 59 | Supply and fixing in replacement offlexi strip trica ac led tricolor strip light street light for poles with optimum brightness and uniformity for perfect cove light, IP-65, 120 LED/Mtr with rated input power 8W per meter , LED Driver : AC Adaptor , input voltage 220-240V AC , frquency 50 Hz , Power factor , Protection open circuitLED revrse polarity , surge withstanding 2.0KV CCT 3000K/4000K/6500Ksuitable for working temp 0 to 100 degree Celcius and also protects against harsh environment outdoor complete all as speceified and directed by Engr In charge - Make : Havells Cat part No FLEXISTRIPTRICAROPE 120D 18MSTRIP or equalavent in PHILLIPS/WIPRO/CROMPTONNote : Rate fortri color strip inclusive of rate of driver for each pole and light should be fixed upto the height of 1.5 Mtr from the ground in the form of National flag color . |
| 60 | M&L for sub-main wiring with two runs of 1.5 sqmm unsheathed PVC insulated, single core heavy duty ISI Marked FRLS cable 1100 volts grade with multistranded copper conductor drawn through and including not less than 20mm dia non metallic rigid PVC white conduit and conduit accesories concealed/fixed to wall/roof/floor and including suitable PVC conduit with 1.5 sqmm copper earth wire after taking out the existing sub-main wiring, making good to the distrubed surfaces also matching the existing surfaces all as specified and directed. Note: 2 runs of cable and one run earth wire and conduit will be measured as one length. |
| 61 | All as per item No 60here-in-before but FRLS copper cable of size 2.5 Sqmm. |
| 62 | Supply and fix in repair LED flood light 150 Watts, 230 V AC outdoor type with thermal management in multiple optics, powder coated pressure die cast aluminium body with toughened glass visor,and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp,CCT 5700K, lumen efficacy not less than 110 lumen/wattsincluding testing commissioning and fixing upto 20 Mtr hight of hanger includingnecessaryfixing arrangement of clamps nut bolts etc complete all as directed by Eng-in-Charge. Make:- Havells Cat Part No: -JETALEGANZAFLS150WLED757P60DTOTG or its equivalent in Crompton,Wipro,Philips |
| 63 | Supply and fix in repair LED flood light 200 Watts, 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lampCCT 5700K, lumen efficacy not less than 110 lumen/wattsincluding testing commissioning and fixing upto 20 Mtr hight of hanger includingnecessaryfixing arrangement of clamps nut bolts, chain lockingetc complete all as directed by Eng-in-Charge. Make:- Havells Cat Part No: - JETALEGANZAFLS200WLED757P60DTOTG or its equivalent in Crompton,Wipro,Philips |
| 64 | All as per item No 63here-in-before but 250 Watts. |
| 65 | Supply and fixing industrial LED High Bay light fitting power range of 200 Watts, powder coated PDC aluminium body & PC optical lenses, Lumen efficiency of >110lm/W, 5700K CCT, Alluminum Die cast housing, IP66with life of 50,000hrs with Eye bolt provided for mounting purpose for fixing onwall/ceiling mount available as accessory, flexible options to meet industrial lighting needs i.e. suspended/fixed to Hanger Ceiling, cool white light colour, material made out of die cast aluminum & extruded aluminum heat sink and finish powder coatedcomplete connecting electrically including testing commissioning and fixing upto 20 Mtr hight of hanger includingnecessaryfixing arrangement of clamps nut bolts, chain locking etc complete all as directed by Engineer-in-charge. Make:- Havells Cat Part No: -PARABELLOHBP200WLED857PTOTGor its equivalent in Crompton,Wipro,Philips |
| 66 | Supply and fixin repair LED lights fitting 20 Watt, 220V, 4 feet long, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge. Make:- Havells Cat Part No: -LUMILINENXTBS20WLED865SPCWH or its equivalent in Crompton,Wipro,Philips |
| 67 | Supply and fixin repair LED lights fitting 10 Watt, 220V, 2 feet long, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge.Make:- Havells Cat Part No: -LUMILINENXTBS10WLED865SPCWH or its equivalent in Crompton,Wipro,Philips |
| 68 | Supply and fixing LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Eng-in-Charge.Make:- Havells Cat Part No: - VENUSTREND2X2PLR36WLED865SWH or its equivalent in Crompton,Wipro,Philips |
| 69 | Supply and fixin repair round/Square shape 15 watt 220 volts AC recessed/surface type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge. |
| 70 | Supply and fixin repair building security light LED street light fitting 72 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-66 protection complete all as specified and directed by Engr-in-Charge.Make:- Havells Cat Part No:- ENDURASUNBEAMSL72WLED757SASYTOPC or its equivalent in Crompton,Wipro,Philips |
| 71 | Supply and fixing in repair 230V 10KA \"C\" curve miniature circuit breaker (MCB) of 32 Amps rating single pole and neutral in the DB complete with connection testing and commissioning all as specified and directed by Engr-in-charge. |
| 72 | Note : (a) Highbay light/Flood light/Street light/recessed, surface mounted light and submain wiring to be repaired/replaced upto 20 Mtr Height. (b) The expenditure on Ladder/Crane will be borne by the contractor and all rates deemed to be inluded the same.(c) Hangar lights must be fixed properly to avoid harm/damages to Aircrafts/Helicopers/persons. |