| 1 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as directed. |
| 2 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depthfor foundation, pipeline etc area not exceeding 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed. |
| 3 | Returning, filling in, including spreading in layers not exceeding 25cm, levelling, watering and well ramming as in hard/dense soil complete all as specified and as directed. |
| 4 | Removing excavated materials to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above starting pointcomplete all as specified and as directed. |
| 5 | Excavating in post holes (or similar holes) each n exc 0.5 cu.m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft and loose soil complete all as specified and directed. |
| 6 | M&L for sand filling under floors or in foundations including watering and consolidationcomplete all as specified and as directed. |
| 7 | M&Lfor hardcore of broken stones of guage not exceeding 63 mm deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 8 | M&L for plain cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and as directed. |
| 9 | M&L for plain cement concrete (1:4:8),type D2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed. |
| 10 | M&L for PCC (1:2:4),type B0 ( using 12.5 mm graded aggregate) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, benching, copings, kneelers, apex stones, bed plates, kerbs,, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 11 | M&L for brick work with sub class \"B\" bricks straight or curved on plan exceeding 6 m mean radius built in cement mortar (1:6) complete all as specified and as directed. |
| 12 | Taking down chowkats or frame exceeding 1.5 Sqm and not exceeding 4.00 Sqm each with shutters (without taking off shutter from the frame) complete all as directed. |
| 13 | Taking down chowkats or frame not exceeding 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as directed. |
| 14 | S&F Powder coated aluminium sliding window including following components / specification complete all as specified and directed.(i) Thickness and weight per metre length of aluminium frame and section of shutter all as shown on drawing. (ii) All vercal/ horizontal joint shall be of extruded aluminium section so as to avoid any play between jointed members. (iii) all other accessories such as jointing cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, srews, etc. (iv) Stainless steel wire cloth 036 mm nominal dia of wire and average width of aparture 1.40 mm and fixed with stainless steel wire staples, etc. (v)Sheet glass 4 mm thick selected quality and glazing with oil putty or fixed with wooden beads in square not exceeding 0.5 Sqm in each pane (vi) Rest all as specified in drawing no CEZ/2015/TD/007 Sheet no 1R/5, 2R/5, 3R/5, 4R/5, 5R/5. |
| 15 | S&F Anodised aluminium powder coating windows and ventilator shutters, (minimum thickness of powder coating 50 micron) side hung type without sash aluminium sections weighing 0.55 kg/m rubber including necessary joining cleats, glazing clips, rudder packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long hinges type B-2 100mm long - 02 Nos, suitable handle - 1 Noincluding4 mm thick frosted sheet glass pieces, complete all as specified and directed. |
| 16 | S&F 8mm thick Aluminium Anodised Grill, design pattern fixed with and including standerd aluminium frame of flat section of size as approved by GE complete all as per manufacturer instruction. |
| 17 | S&F 4mm thick, Frosted glass, ordinary quality and glazing with oil putty or fixed with beads in squares not exc 0.5 sqm in each pane complete all as specified and as directed. |
| 18 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, in roof covering including ridges complete all as specified and as directed. |
| 19 | S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of profile as approved, any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with L-type or J-type or cranked hook bolt in lieu of screw complete all as specified and as directed. |
| 20 | S&F for pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/valley gutter, fixed with L-type or J-type or cranked hook bolt in lieu of screw complete all as specified and as directed.Note : Colour of ridge shall be same colour as that of sheet used for roof. |
| 21 | Supply and fix mild steel work as in Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde E-165 complete all as specified and as directed |
| 22 | M&L for mild steelframed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bar, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290 Gde (E-165) complete all as specified and as directed. |
| 23 | M&L for 75 mm thick plain cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base of floor, etc complete all as specified and as directed. |
| 24 | M&L for 40mm thick, PCC (1:2:4), type B-1 (using 20mm graded stone aggregate) as in sub base of floor etc andfinished even and smooth without using extra cement complete all as specified and directed. |
| 25 | M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed or bedding layer of cement mortar in (1:6) for laying floor finishes complete all as specified and as directed. |
| 26 | M&L for coloured glazed ceramic tiles in vertical surface as skirting, dado and risers to steps etc, of size 450X 300X 7 mm thick over 10mm thickrendering as backing coat in cement mortar (1:4) , set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, complete all as specified and directed. |
| 27 | Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and as directed |
| 28 | M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces as in walls in cement mortar (1:4) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 29 | M&L for rendering 15 mm thick in cement mortar (1:6) on other than fair faces of brick masonry or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 30 | M&L for rendering 20mm thick in two layers of 10 mm thick each(10+10) in cement morter (1:4) on fair faces of brick work or concrete surfaces and WPC shall be mixed with morter of top layer, finished even and fair, complete all as specified and directed.(Note:WPC shall be measured and paid separately as supply only) |
| 31 | Supply only liquid water proofing compound for external wall plastering (for 5 mm thick plastering) complete all as specified and as directed. |
| 32 | M&L for preparation of new plastered surfaces of wall etc and applying two coats of oil bound distemper over a coat of alkali resistant primer over a coat of 2mm thick wall care putty complete all as specified and as directed. |
| 33 | M&L for preparation of newly plastered surface of walls etc and applying three coats of white washonwalls complete all as specified and directed |
| 34 | M&L for preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 35 | Supply, laying, connection and testing, 20mm bore, steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and as directed. |
| 36 | S&F in repairs 20mm bore gun metal gate valve with iron wheel head, screwed both ends for iron pipe or for unions complete all as specified and as directed. |
| 37 | Supply and install 2 TON hi wall split units indoor/ outdoor complete with cordless remote control unit with BEE 5 Star Rating arrangement and Digital Inverter twin rotary including all the accessories needed for its installation complete all as specified and as directed. |
| 38 | Supply and install 1.5 TON hi wall split units indoor/ outdoor complete with cordless remote control unit with BEE 5 Star Rating arrangement and Digital Inverter twin rotary including all the accessories needed for its installation complete all as specified and as directed. |
| 39 | S&F of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for innput variation between 170V to 250 v with output voltage stabilizd at 230 v with accuracy of 2.5% and of capacity 5 KVA including all the accessories needed for installation complete all as specified and as directed. |
| 40 | Material & labour for Sub main wiring with two runs of single core 4 Sqmm (Nominal Area) FRLSH PVC insulated and unsheathed multi standed copper conductor cable LT 1100 volts grade drawn thorugh and including PVC casing caping of adequate size fixed on surface of wall/ceiling with all necessary fittings and accessaries and 1 run of FRLSH PVC insulated and unsheathed insulated single core cable with multi standered copper conductor of size 4 Sqmm as earth wire (green in colour) run through PVC Casing caping and connected common earth dolly including taking out the old sub main wiringfor connection to DBs/dolly shall be deemed to be included in this item and Two runs of 6 Sq mm as current carrying conductor and one run of4 Sq mm as earth conductor PVC conduit shall be measured as one run for measurement complete all as specified and as directed. |
| 41 | S&F of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB including all the fixtures for its installtion complete all as specified and as directed. |