| 1 | Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth in soft / loose soil and getting out for removing / laying of pipe lines complete all as specified and directed by Engr-in-Charge. |
| 2 | Returning and filling including spreading, levelling, watering and well ramming in layers not exceeding 25 Cm thick complete all as specified and directed by Engr-in-Charge. |
| 3 | Removing of surplus soil to a distance not exceeding 50 Mtrs and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engr-in-Charge. |
| 4 | M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in floor / hard-standing, surface finished even and smooth without using extra cement to match with the existing surface complete all as specified and directed by Engr-in-Charge. |
| 5 | M&L complete for drilling hole of 150mm dia under hard standing /road for laying of pipe by means of manual buckle and without disturbing the top surface and making good the disturbed surface if any complete all as specified and directed by Engr-in-charge. |
| 6 | Dismantling and taking down unserviceable steel tubing and connection including cleaning the same for re-fixing or removal with stop valves or gate valves complete all as specified and directed by Engr-in-Charge of the following sizes:- |
| 7 | 15 mm dia |
| 8 | 20 mm dia |
| 9 | 25 mm dia |
| 10 | 40 mm dia |
| 11 | 50 mm dia |
| 12 | 80 mm dia |
| 13 | 100 mm dia |
| 14 | Taking up Cast iron pipe water mains (including all fittings) with spigot and socket ends and lead joints including burning out joints and recovering lead of size 80 mm dia bore complete all as specified and as directed by Engr-in-Charge. |
| 15 | Taking up Cast iron pipe water mains (including all fittings) with spigot and socket ends and lead joints including burning out joints and recovering lead of size 100 mm dia bore complete all as specified and as directed by Engr-in-Charge. |
| 16 | Supply, Laying, jointing and testing of GI tubing medium grade with all fittings such as bend, tee, elbow, union, reducer etc, laid in trenches complete all as specified and as directed at site by Engr-in-charge of the following sizes:-Note:(i) The laying and jointing of pipes are required to be carried out in short/long stretches catering to specific requirements of a particular quarter, building block or a group of blocks.(ii) Excavation & earth work shall be measured & paid separately. |
| 17 | 15 mm dia |
| 18 | 20 mm dia |
| 19 | 25 mm dia |
| 20 | 40 mm dia |
| 21 | 50 mm dia |
| 22 | 80 mm bore |
| 23 | 100 mm bore |
| 24 | S&F of cast iron pipes with spigot and socket ends centrifugally cast 80 mm dia class LA, in any length laid in trenches including jointing materials complete all as specified and as directed by Engr-in-Charge. Note: Earth work and CI fittings measured and separate items |
| 25 | S&F of cast iron pipes with spigot and socket ends centrifugally cast 100 mm dia class LA, in any length laid in trenches including jointing materials complete all as specified and as directed by Engr-in-Charge. Note: Earth work and CI fittings measured and separate items |
| 26 | S&F CI fittings for spigot and socket pipes such as bends (any type, radius and angle) tapers any type, (straight, bend increasing, decreasing or double socket etc) Tee pieces single branch, single branch, \"Y\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs upto 150mm dia bore complete all as specified and directed by Engr-in-Charge. |
| 27 | Supply, Laying, jointing and testing of GI Pipe medium grade including supply and fixing of all fittings such as bend, tee, elbow, union, reducer etc, laid on floor / walls etc complete all as specified and as directed at site by Engr-in-charge of the following sizes:- Note: (i) The laying and jointing of pipes are required to be carried out in short/ long stretches catering to specific requirements of a particular quarter, building block or a group of blocks. (ii) Excavation & earth work shall be measured & paid separately. |
| 28 | 15 mm dia |
| 29 | 20 mm dia |
| 30 | 25 mm dia |
| 31 | 40 mm dia |
| 32 | 50 mm dia |
| 33 | M&L in repair for leakages of CI pipes with spigot and socket ends, de-watering of pipe lines and trenches, burning out joints to recover lead and making new lead joint with retrieved material and any additional quantity of lead required as per site requirement including all other materials such as spun yarn, fire wood etc complete all as specified and as directed for the following sizes.Note: Excavation & earth work shall be measured & paid separately. |
| 34 | 80mm dia |
| 35 | 100mm dia |
| 36 | M&Lin repair for run lead joint for cast iron water mains / fittings and finishing complete all as specified and directed by Engr-In-Charge for the following sizes :- |
| 37 | 80mm dia |
| 38 | 100mm dia |
| 39 | S&Fin replacement of sluice valve class PN-1.6, heavy duty, both ends flangedwith steel spindle & check nut, CI operating wheel and all nuts, bolts, washers, gaskets etc. complete all as specified and directed by Engr-In-Charge of the following sizes:- |
| 40 | 80mm dia |
| 41 | 100mm dia |
| 42 | S&F in replacement of Gun metal iron gate valve with iron wheel head, screwed both ends for iron pipe, ISI marked complete all as specified and directed by Engr-In-Charge for the following sizes :- |
| 43 | 15 mm dia |
| 44 | 20 mm dia |
| 45 | 25 mm dia |
| 46 | 40 mm dia |
| 47 | 50 mm dia |
| 48 | S&F in replacement of 15 mm dia Ball brass valve, high pressure, with polythene float and flynut complete screwed for brass ferrule complete all as specified and directed by Engr-In-Charge. |
| 49 | S&F in replacement of 20 mm dia Ball brass valve, high pressure, with polythene float and flynut complete screwed for brass ferrule complete all as specified and directed by Engr-In-Charge. |
| 50 | S&F in replacement of 25 mm dia Ball brass valve, high pressure, with polythene float and flynut complete screwed for brass ferrule complete all as specified and directed by Engr-In-Charge. |
| 51 | S&F in replacement of 80 mm bore non return sluice valve ISI marked both end flanged suitable for cast iron pipe including all fittings washer, nuts & bolt etc complete all as specified and directed by Engr-in-Charge. |
| 52 | S&F in replacement of 100 mm bore non return valve ISI marked both end flanged suitable for cast iron pipe including all fittings washer, nuts & bolt etc complete all as specified and directed by Engr-in-Charge. |
| 53 | M&L in repairs for construction of valve chamber in replacement600 x 600 x 950 mm internal dimensions,6 mm thick MS sheet cover with 2 Nos MS hinges welded to angle iron frame of 40mm x 40mm x 6 mm thick with lifting hook and locking arrangement complete with necessary earth work, brick work in CM (1:6), 230 mm thick,PCC bed (1:4:8) type D2 150 mm thick, cement plastering, finishing 15 mm thick in CM (1:4) and applying a coat of black bituminous paint to the steel surfaces including dismantling and removal of old unserviceable valve pit remains complete all as specified and directed by Engr-in-Charge at site. |
| 54 | M&L in repair for construction of valve chamber in replacement950 x 950 x 950 mm internal dimensions, 6 mm thick MS sheet cover with 2 Nos MS hinges welded to angle iron frame of 40mm x 40mm x 6 mm thick with lifting hook and locking arrangement complete with necessary earth work, brick work in CM (1:6), 230 mm thick,PCC bed (1:4:8) type D2 150 mm thick, cement plastering, finishing 15 mm thick in cement mortar (1:4) and applying a coat of black bituminous paint to the steel surfaces including dismantling and removal of old unserviceable valve pit remains complete all as specified and directed by Engr-in-Charge at site. |
| 55 | De-watering by using pump as required and, removal of mud and settled silt including scrapping of complete inner surface with the help of wire brush etc and therefore cleaning by water and bleaching of the following OH tank / UG sumps / Static Water tanks. And apply two coat of white wash to all internal surface of wall and two coat of colour wash to all external surface including top surface and painting to oblitering labels shall be not less than 60 x 40 cm using black paint to match with existing dimension and writing particulars such as capacity of sump, date/ due date of cleaning etc using white paint including disposal of mud silt etc obtained after cleaning up to 50 m away complete all as specified and directed by Engr-In-Charge for the following capacity of UG sumps:- Note: Rate includes for marking on tank, date of cleaning and due date of next cleaning. |
| 56 | All as per srl item No 23.00 but for Semi UG sump of capacity 50000 GLNS at Bani Camp complete all as specified and directed by Engr-in-charge. |
| 57 | All as per srl item No 23.00 but for Static Water Tank of capacity 20000 GLNS at Bani Camp complete all as specified and directed by Engr-in-charge. |
| 58 | Testing of Raw Water/Treated water for bacteriological analysis, Chemical analysis, Arsenic presence test from any Govt. Approved/recognized Lab as approved by the GE. Note:- Contractor will be responsible to carry out the sample & submit report timely. |
| 59 | M&L for servicing of centrifugal /mono block pump set 20 HP, Opening the pump and re-fixing machining the pump shaft and shaft key ways, impeller shaft hole etc and replacing the key, impeller nut, gland packing, gland nuts and coupling as per existing size including re-fixing the same to the original position and commissioning testing complete all as specified and as directed by Engr-in-charge. |
| 60 | M&L for servicing of centrifugal /mono block pump set 15 HP, Opening the pump and re-fixing machining the pump shaft and shaft key ways, impeller shaft hole etc and replacing the key, impeller nut, gland packing, gland nuts and coupling as per existing size including re-fixing the same to the original position and commissioning testing complete all as specified and as directed by Engr-in-charge. |
| 61 | M&L for servicing of centrifugal /mono block pump set 7.5 HP, Opening the pump and re-fixing machining the pump shaft and shaft key ways, impeller shaft hole etc and replacing the key, impeller nut, gland packing, gland nuts and coupling as per existing size including re-fixing the same to the original position and commissioning testing complete all as specified and as directed by Engr-in-charge. |
| 62 | M&L for rewinding of electric motor upto 20 HP 50 Hz 415 volts of mono block/centrifugal pump of any make and type with super enameled copperwinding wireincluding bearing bushes and other accessories etc required to make motor functional and testing on load complete all as specified and directed by Engr-in-Charge. |
| 63 | M&L for rewinding of electric motor upto 15 HP 50 Hz 415 volts of mono block/centrifugal pump of any make and type with super enameled copperwinding wireincluding bearing bushes and other accessories etc required to make motor functional and testing on load complete all as specified and as directed by Engr-in-charge. |
| 64 | M&L for rewinding of electric motor upto 7.5 HP 50 Hz 415 volts of mono block/centrifugal pump of any make and type with super enameled copperwinding wireincluding bearing bushes and other accessories etc required to make motor functional and testing on load complete all as specified and as directed by Engr-in-charge. |
| 65 | M&L for rewinding of electric motor upto 5 HP 50 Hz 415 volts of mono block/centrifugal pump of any make and type with super enameled copperwinding wireincluding bearing bushes and other accessories etc required to make motor functional and testing on load complete all as specified and as directed by Engr-in-charge. |
| 66 | M&L for rewinding of submersible motor by taking out burnt copper winding, cleaning the casing & slots with wire brush & washing with pressure water & shall be dried, rewinding the motor using required gauge of super enameled copper winding wire.Making the winding leak proof & taking out the electric connection with suitable size of submersible cable upto 03 meter, capacity of motor 5 HP complete all as specified and as directed by Engr-in-charge. |
| 67 | All as per item No 32.00 above but of capacity 2 HP complete all as specified and as directed by Engr-in-charge. |
| 68 | M&L for replacement of submersible of capacity 2.0 HP ThreePhase, 50 Hz 415 Volts, Suction X Delivery size of 50 x 40 mm, CI Impeller, and 3000 rpm including all connections complete all specified and directed by Eng-in-Charge. |
| 69 | S&F in replacement of6 Sqmm multistranded copper conductor, 3 core PVC insulated and sheathed copper screen protected 1100 Volts grade submersible flat cable fixed to column pipes with suitable clamps &jointing material complete including disconnecting complete all as specified and as directed by Engr-in-Charge. |
| 70 | M&L for Rotational moulded polyethylene water storage of capacity 1000 Ltr (cylindrical vertical type with closed top) hoisted and fixed in position all as specified in SSR Part-I complete all as specified and as directed by Engr-in-Charge |
| 71 | M&L for Rotational moulded polyethylene water storage of capacity 5000 Ltr (cylindrical vertical type with closed top) hoisted and fixed in position all as specified in SSR Part-I complete all as specified and as directed by Engr-in-Charge |
| 72 | M&L for Rotational moulded polyethylene water storage of capacity 10000 Ltr (cylindrical vertical type with closed top) hoisted and fixed in position all as specified in SSR Part-I complete all as specified and as directed by Engr-in-Charge |
| 73 | Taking down, dismantling / unscrewing electric water heater (Geyser) for repair / servicing and refixing after repair reconnecting of electrical and water supply and testing with water pressure complete all as specified and directed by Engr-in-charge. Note : Spare parts of geyser measure and paid separately are as under. |
| 74 | S&F in repairs of complete for heating element 1500 watt, ISI marked of any type copper sheathed and nickel plated of suitable size complete all as specified and directed by Engr-in-charge. |
| 75 | S&F in repairs of complete for heating element 2000 watt, ISI marked of any type copper sheathed and nickel plated of suitable size complete all as specified and directed by Engr-in-charge. |
| 76 | S&F in repairs of complete for thermostat suitable for 25/50 Litre water heater(Geyser) of any make ranging from 0 C to 90 C complete all as specified and directed by Engr-in-charge. |
| 77 | S&F in repairs of in repair base plate assembly complete with rubber packing suitable for water heater (geyser) of any make/any model 25 litre capacity complete all as specified and directed by Engr-in-charge. |
| 78 | S&F in repairs of base plate assembly complete with rubber packing suitable for water heater (geyser) of any make/any model 35/50 litre capacity complete all as specified and directed by Engr-in-charge. |
| 79 | S&F in repairs of safety valve suitable for 25ltr/35ltr/50ltr geysers complete all as specified and directed by Engr-in-charge. |
| 80 | S&F in repairs of geyser inner tank (copper) of 25 litre capacity complete all as specified and directed by Engr-in-charge. |
| 81 | S&F in repairs of geyser inner tank (copper) of 35/50 litre capacity complete all as specified and directed by Engr-in-charge. |
| 82 | S&F in repairs of glass wool for geyser complete all as specified and directed by Engr-in-charge. |
| 83 | S&F in repairs of fusible plug having melting point 90 degree C/100 degree C (as per sample) complete all as specified and directed by Engr-in-charge. |
| 84 | S&F in repairs of neon lamp indicator red / green rectangular / round type, complete all as specified and directed by Engr-in-charge. |
| 85 | S&F in repairs of plug top 3 pin 15 Amps ISI Marked complete all as specified and directed by Engr-in-charge. |
| 86 | S&F in repairs of replacement for PVC connection 15mm size dia of 450mm long with check nuts on both end with rubber washer complete all as specified and directed by Engr-in-charge. |
| 87 | S&F in repairs of replacement for PVC connection 15mm size dia of 750mm long with check nuts on both end with rubber washer complete all as specified and directed by Engr-in-charge. |
| 88 | S&F in repairs of PVC insulated flexible cable 3 core with stranded copper conductor of size 2.5 Sqmm complete all as specified and directed by Engr-in-charge. |
| 89 | Taking down carefully sub main wiring off size including batten and making good disturbed surface of wall complete all as specified and directed by Engr-in-charge. |
| 90 | M&L complete for sub main wiring with single core copper multi strand conductor FRLSinsulated (unsheathed) cable of size 2x06 Sqmm and 1x06 Sqmm as in continuous earth wire drawn into & including PVC conduit medium 25mm dia ISI marked complete with fittings and fixings accessories laid concealed complete and including necessary cement work complete all as directed by the Engr in charge including cutting chases pinning in making good to facing and pointing in cement mortar 1;3 to the ends or cutting chases for concealed conduit sub main wiring and making good disturbed surface complete all as specified and directed by Engr-in-charge. Note:Cutting not exc 4cm girth and 4cm width. |
| 91 | Taking down carefully aluminium/copper point wiring on batten or in PVC conduit or in MS conduit with GI earth wire etc (for light, fan, socket or power), including fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and making goodthe disturbedsurfaces of walls, Floors, ceilings etc. complete all as specified and directed by Engr-in-charge. |
| 92 | M&L complete for wiring with cable of size 4.00 Sqmm single core copper multistrand conductor including 4.00 Sqmm continuous earth wire in PVC pipe, using cable FRLSinsulated(unsheathed) 1100 volts grade conforming to Is-694 drawn in to and including concealedPVC rigid conduit medium duty with all fittings and fixing accessoriesISI certified IS 9537 part -3 and terminated in to pressed steel metal flushboxes, brackets etc andincluding necessary cement work complete all as specified and directed by Engr-in-charge. |
| 93 | S&F in repairs of complete for modular socket 2 in 1, 6 pin 6A/16 Amp- 2/3pin combined 2 module complete all as specified and directed by Engr-in-charge. |
| 94 | S&F in repairs of Complete for modular switch one way 16 amps 1 module complete all as specified and directed by Engr-in-charge. |
| 95 | S&F in replacement for single pole and neutral enclosures with a two pin and earth plug and socket complete with one single pole MCB of 20 Amp capacity with alignment 10 KA ‘C’ series including electric connection complete all as specified and directed by Engr-in-charge. |
| 96 | S&F in repairs of water heater, storage type steel body with inner tank and heating element upto 2 KWcapacity 25 Litre, BEE 5 star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc. complete all as specified and directed by Engr-in-charge.Note : The old unserviceable geysers should be deposited at AGE E/M yard |
| 97 | S&F in repairs of water heater, storage type steel body with inner tank and heating element upto 2 KW capacity 35 Litre, BEE 5 star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc. complete all as specified and as directed by Engr-in-charge. Note : The old unserviceable geysers should be deposited at AGE E/M yard |
| 98 | Taking down Geyser capacity 25/50 ltrs from its existing position duly disconnected inlet/outlet water connection and painting of geysers with 1st grade synthetic enameled paint (DUCO) by spraying after preparation of old steel surface including refixing the geysers after successful painting to its existing position including making connection of inlet/outlet water connection and testing complete all as specified and directed by Engr-in-charge. |
| 99 | S&F in replacement complete for stop valves fancy type chromium plated cast copper alloy, screwed down high pressure with crutch or butter fly handle external threaded screwed both ends for iron pipes of 20 mm dia complete all as specified and directed by Engr-in-charge. |
| 100 | S&F in replacement complete for stop valves fancy type chromium plated cast copper alloy, screwed down high pressure with crutch or butter fly handle external threaded screwed both ends for iron pipes of 15 mm dia complete all as specified and directed by Engr-in-charge. |
| 101 | S&F in replacement complete for bib taps cast copper alloy screwed down high pressure with crutch or butterfly handle external threaded screwed for iron pipes 20 mm dia complete all as specified and directed by Engr-in-charge. |
| 102 | S&F in replacement complete for bib taps cast copper alloy screwed down high pressure with crutch or butterfly handle external threaded screwed for iron pipes 15 mm dia complete all as specified and directed by Engr-in-charge. |
| 103 | Taking down of unserviceable PVC tank of any capacity and disconnecting of all GI pipe complete all as specified and directed by Engr-in-charge. |
| 104 | M&L for rotational moulded polyethylene water storage tanks Capacity 500 Ltr (Cylindrical vertical with closed top) hoisted and fixed in position includingconnectioncomplete all as specified and directed by Engr-in-charge. |
| 105 | M&L in replacement of MS angle of size 45 X 45 X 5 mm for stand of solar hot water storage tank and solar collector complete all as specified and directed by Engr-in-charge. |
| 106 | M&L for PCC (1:2:4) type B1 using 20 mm graded stone aggregate in foundation, mass concrete fixing for solar water tank /panel complete all as specified and directed by Engr-in-charge. |
| 107 | S&F in replacement complete for flat plate solar collectors toughened glass 3 mm thick of size 1992x1090 mm, including all fixing accessories complete all as specified and directed by Engr-in-charge. |
| 108 | S&F in replacement complete for flat plate solar collectors frame box, including all fixing accessories complete all as specified and directed by Engr-in-charge. |
| 109 | S&F in replacement complete for flat plate solar collectors copper absorber including all fixing accessories complete all as specified and directed by Engr-in-charge. |
| 110 | Disconnecting the unserviceable heat collector panels any capacity any types from solar tank carefully, complete all as specified and directed by Engr-in-charge. |
| 111 | S&F in repairs of complete for flat plate solar collectors of size 1992x1090x100 mm complete puff insulated collector accessories complete all as specified and directed by Engr-in-charge. |
| 112 | Taking down of unserviceable worn out solar tank disconnecting all connection of GI pipe complete all as specified and directed by Engr-in-charge. |
| 113 | S&F in replacement complete for 200 LPD solar hot water storage tank SS 304 L grade vertical/horizontal with insulation of 50 mm puff insulated tank with pre powder coated GI sheet complete all as specified and directed by Engr-in-charge. |
| 114 | M&L complete for hot water pipe duly insulated with glass wool and aluminium cladding 15mm bore GI pipe complete all as specified and directed by Engr-in-charge. |
| 115 | M&L complete for hot water pipe duly insulated with glass wool and aluminium cladding 20mm bore GI pipe complete all as specified and directed by Engr-in-charge. |
| 116 | M&L complete for hot water pipe duly insulated with glass wool and aluminium cladding 25mm bore GI pipe complete all as specified and directed by Engr-in-charge. |
| 117 | M&L in replacement complete for fire alarm control panel complying with BS EN 54, two loop panel of capacity from with 99 detectors and 99 modules(per each loop) complete all as specified and directed by Engr-in-charge. |
| 118 | M&L in replacement complete for detectors complying with and type certified to En 45 addressable type multi sensor detector with heat and smoke combination complete all as specified and directed by Engr-in-charge. |
| 119 | M&L in replacement complete for beam master detector with transmitter and receiver (add power supply unit & module) complete all as specified and directed by Engr-in-charge. |
| 120 | M&L in replacement complete for addressable control module complete all as specified and directed by Engr-in-charge. |
| 121 | M&L in replacement complete for addressable monitor module complete all as specified and directed by Engr-in-charge. |
| 122 | M&L in replacement complete for Fire alarm sounders / sirens electronic type horizontal two stage continuous normal operation for at least 50 minutes with sound level 65 db to 120 db measured at 1.5 m with sound output variation of + 5db 500m range complete all as specified and directed by Engr-in-charge. |