| 1 | Demolishing cement concrete manually/ by mechanical means including disposal of material within all lead and lift as per direction of Engineer - in - charge. a) Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 2 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within all lead and lift. a) For thickness of tiles 10 mm to 25 mm as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, within all lead & lift including getting out the excavated soil and disposal of surplus excavated soil as directed, within all lead and lift.a) All kinds of soil as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :a) 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :a) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form work for: a) Foundations, footings, bases for columns as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :a) 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for :a) Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. a) Thermo-Mechanically Treated bars of grade Fe-500D or more as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 10 | Half brick masonry with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. a) Cement mortar 1:3 (1 cement :3 coarse sand) as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 11 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. ird course of half brick masonry as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 12 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. a) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 13 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc.,., complete as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 14 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. a) 110 mm diameter as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 15 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.a) Coupleri) 110mm as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 16 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.a) Bend 87.5°i) 110 mm bend as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 17 | 12 mm cement plaster of mix :a) 1:4 (1 cement: 4 coarse sand) as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 18 | Finishing walls with textured exterior paint of required shade :a) New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @2.20kg/10 sqm as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 19 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:a) Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 20 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 21 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.a) Two coats as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 22 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. : External worka) 65 mm dia. nominal bore as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 23 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :a) 50 to 80 mm nominal bore as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 24 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :a) 65 mm nominal bore as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 25 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work)a) 65mm nominal bore as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |
| 26 | Rebound hard plaster for squash courts as per the specification including game line marking, removing of existing plaster and cleaning the surface as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. |