| Sl. No. | Item Description |
| 1 | LT Panel complete in all respect for Boot Plant Sub-Station. Details mentioned in Tender documentAs Per Annexure-C . |
| 2 | LT Distribution Panel for LCS Cutting Line, Closing Line and Moulding Shop. Details mentioned in Tender documentAs Per Annexure-C . |
| 3 | Supply and Fixing of three phase & neutral closed busbar chamber of size 12 Inch X 08 Inch of 250 Ampere with powder coated sheet metal 16 gauge including earth protection with aluminium strip 25mmX03mm and hanging arrangement. |
| 4 | Sheet metal enclosures 450mmX300mmX150mm for feeding three phase & Neutral Bas Bar, Ampere meter with selector switch, Volt meter with selector switch, RYB Phase indicator, fixing arrangement for MCB\"s Triple pole and neutral, duly powder coated including wiring, cable gland and locking arrangement. |
| 5 | Taking down fan, sealing cable end, dismantaling blades and removing fan and blades to store. |
| 6 | Hanging only ceiling fan (M. D. Supply) and connecting up including provision of cable from ceiling rose. |
| 7 | Earthing complete with galvanised steel earth plate electrode 60cmX60cmX6mm thick burried directly in ground connection using galvanised iron strip 25X4 mm as earth lead. |
| 8 | S&F Industrial LED Tube Light fitting with detachable tube rod, 2X20 Watt, 220VAC with driver, holder including led tube light, refelectorconnecting up with three core flexible copper conductor cable of suitable size to MCB installed on 4-way DB at closed busbar chamber. |
| 9 | Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors,etc. |
| 10 | Taking down copper / aluminium point wiring (light, fan, socket or power) complete, incluiding fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets light fitting etc. removing materials to store for keeping in safe custody and making good disturbed surfaces of walls, floors,etc. |
| 11 | Taking down by unscrewing from boards / outlet boxes fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets light fitting etc. removing materials to store for keeping in safe custody and making good disturbed surfaces of walls, floors,etc. |
| 12 | Point wiring of one light point or one fan point controlled by one switch with PVC single core, sheathed copper conductor cable 1.5 Sqr.mm size in PVC conduit pipe (M&L) |
| 13 | Point wiring of one 3 pin socket outlet 5 Amp on the same board with other switches with PVC single core, sheathed copper conductor cable 1.5 Sqr.mm size in PVC conduit pipe (M&L). |
| 14 | Point wiring of one 3 pin socket outlet 5 Amps independent, PVC single core, sheathed copper conductor cable 1.5 Sqr.mm size in PVC conduit pipe (M&L). |
| 15 | Switch Piano, flush type single pole, one way 5Amp (S&F) |
| 16 | Socket outlet 2 in 1, 3pin, 5Amps flush type (M&L). |
| 17 | Ceiling rose, 3 Phase/ PVC/ Polycarbonate, isolated body (M&L). |
| 18 | Point wiring of one 3 pin 15Amp socket outlet independent with PVC single core, sheathed copper conductor cable 4 Sqr.mm size in PVC conduit pipe (M&L) |
| 19 | Switch Piano, flush type single pole, one way 15Amp (S&F) |
| 20 | Socket outlet 2 in 1, 3pin, 5 and 15 Amp. Flush type (M&L). |
| 21 | PVC rectangular block size 250X200x50mm deep (M&L). |
| 22 | PVC rectangular block size 175X100x50mm deep (M&L). |
| 23 | Sheet metal enclosures for MCB\"s Triple pole and neutral 4 way,with 200Amp ratedB/Bar 415VAC Double door covering open space with MCB blanker (S&F). |
| 24 | Sheet metal enclosures for MCB\"s Triple pole and neutral 8 way,with 200Amp ratedB/Bar 415VAC Double door covering open space with MCB blanker(S&F). |
| 25 | Sheet metal enclosures for MCB\"s single pole & neutral 8 way,with 200Amp ratedB/Bar 240VAC Double door covering open space with MCB blanker(S&F). |
| 26 | S&F of Sheet metal enclosures for MCB\"s single pole & neutral 4 way,with 200Amp ratedB/Bar 240VAC Sigle door covering open space with MCB blanker 4 way DB must be fitted in overhead busbar. Three phase and neutral must be connected with 4 way DB. |
| 27 | Sheet metal enclosures for MCB\"s single pole & neutral 2 way,without B/Bar 240VAC Double door covering open space with MCB blanker(S&F). |
| 28 | Isolator TP 40Amp 415VAC (M&L). |
| 29 | Isolator TPN 40Amp 415VAC (M&L). |
| 30 | Isolator TPN 100Amp 415VAC (M&L). |
| 31 | Isolator DP 40Amp 240VAC (M&L). |
| 32 | Isolator SP 40Amp 240VAC (M&L). |
| 33 | Wiring for circuit / submain wiring along with earth wire with 2X2.5 sqmm +1X1.5 sq. mm FR PVC insulated copper conductor single core |
| 34 | Wiring for circuit / submain wiring along with earth wire with 2X4.0sqmm +1X2.5 sq. mm FR PVC insulated copper conductor single core |
| 35 | Wiring for circuit / submain wiring along with earth wire with 2X6.0 sq mm +1X4.0sq. mm FR PVC insulated copper conductor single core |
| 36 | S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as required. |
| 37 | Rigid non-metallic PVC coduit 20mm dia exclusive of boxes (junction/terminal) but inclusive of all tees,bends,elbows,reducers,bell mouth tube ends and fixing accessories such as couplers,lock nuts, saddles, pipe hooks etc. (Fixing Only). |
| 38 | Cutting chases for concealed conduit wiring etc and making good cutting not exe 10cm girth. |
| 39 | Single pole and neautral sheet metal enclosure with a two pin and earth plug and socket complete with 20Amp single pole MCB. |
| 40 | PVC insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 35 Sq. mm 3 & 1/2 core. |
AI Tender Summary
Tender Timeline
Aug 29, 2024
11:30 IST
Tender Published
Tender notice published.
CompletedSep 12, 2024
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedSep 14, 2024
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender