Defence Government Departments Closing in 0 days TDR #44975708

Tender For Repair Or Renovation Of Electrical System Of Lcs Shop Of Boot Plant Inside Factory At Oefc

Issued by Government Departments · kanpur, Uttar Pradesh
Tender Value
47 Lakhs
Estimated cost
Bid Submission
12 Sep 2024
0 days left
EMD
94000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
kanpur → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Repair Or Renovation Of Electrical System Of Lcs Shop Of Boot Plant Inside Factory At Oefc

BOQ

Name of Work:Repair/renovation of Electrical system of LCS Shop of Boot Plant inside factory at OEFC
Sl. No. Item Description
1LT Panel complete in all respect for Boot Plant Sub-Station. Details mentioned in Tender documentAs Per Annexure-C .
2LT Distribution Panel for LCS Cutting Line, Closing Line and Moulding Shop. Details mentioned in Tender documentAs Per Annexure-C .
3Supply and Fixing of three phase & neutral closed busbar chamber of size 12 Inch X 08 Inch of 250 Ampere with powder coated sheet metal 16 gauge including earth protection with aluminium strip 25mmX03mm and hanging arrangement.
4Sheet metal enclosures 450mmX300mmX150mm for feeding three phase & Neutral Bas Bar, Ampere meter with selector switch, Volt meter with selector switch, RYB Phase indicator, fixing arrangement for MCB\"s Triple pole and neutral, duly powder coated including wiring, cable gland and locking arrangement.
5Taking down fan, sealing cable end, dismantaling blades and removing fan and blades to store.
6Hanging only ceiling fan (M. D. Supply) and connecting up including provision of cable from ceiling rose.
7Earthing complete with galvanised steel earth plate electrode 60cmX60cmX6mm thick burried directly in ground connection using galvanised iron strip 25X4 mm as earth lead.
8S&F Industrial LED Tube Light fitting with detachable tube rod, 2X20 Watt, 220VAC with driver, holder including led tube light, refelectorconnecting up with three core flexible copper conductor cable of suitable size to MCB installed on 4-way DB at closed busbar chamber.
9Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors,etc.
10Taking down copper / aluminium point wiring (light, fan, socket or power) complete, incluiding fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets light fitting etc. removing materials to store for keeping in safe custody and making good disturbed surfaces of walls, floors,etc.
11Taking down by unscrewing from boards / outlet boxes fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets light fitting etc. removing materials to store for keeping in safe custody and making good disturbed surfaces of walls, floors,etc.
12Point wiring of one light point or one fan point controlled by one switch with PVC single core, sheathed copper conductor cable 1.5 Sqr.mm size in PVC conduit pipe (M&L)
13Point wiring of one 3 pin socket outlet 5 Amp on the same board with other switches with PVC single core, sheathed copper conductor cable 1.5 Sqr.mm size in PVC conduit pipe (M&L).
14Point wiring of one 3 pin socket outlet 5 Amps independent, PVC single core, sheathed copper conductor cable 1.5 Sqr.mm size in PVC conduit pipe (M&L).
15Switch Piano, flush type single pole, one way 5Amp (S&F)
16Socket outlet 2 in 1, 3pin, 5Amps flush type (M&L).
17Ceiling rose, 3 Phase/ PVC/ Polycarbonate, isolated body (M&L).
18Point wiring of one 3 pin 15Amp socket outlet independent with PVC single core, sheathed copper conductor cable 4 Sqr.mm size in PVC conduit pipe (M&L)
19Switch Piano, flush type single pole, one way 15Amp (S&F)
20Socket outlet 2 in 1, 3pin, 5 and 15 Amp. Flush type (M&L).
21PVC rectangular block size 250X200x50mm deep (M&L).
22PVC rectangular block size 175X100x50mm deep (M&L).
23Sheet metal enclosures for MCB\"s Triple pole and neutral 4 way,with 200Amp ratedB/Bar 415VAC Double door covering open space with MCB blanker (S&F).
24Sheet metal enclosures for MCB\"s Triple pole and neutral 8 way,with 200Amp ratedB/Bar 415VAC Double door covering open space with MCB blanker(S&F).
25Sheet metal enclosures for MCB\"s single pole & neutral 8 way,with 200Amp ratedB/Bar 240VAC Double door covering open space with MCB blanker(S&F).
26S&F of Sheet metal enclosures for MCB\"s single pole & neutral 4 way,with 200Amp ratedB/Bar 240VAC Sigle door covering open space with MCB blanker 4 way DB must be fitted in overhead busbar. Three phase and neutral must be connected with 4 way DB.
27Sheet metal enclosures for MCB\"s single pole & neutral 2 way,without B/Bar 240VAC Double door covering open space with MCB blanker(S&F).
28Isolator TP 40Amp 415VAC (M&L).
29Isolator TPN 40Amp 415VAC (M&L).
30Isolator TPN 100Amp 415VAC (M&L).
31Isolator DP 40Amp 240VAC (M&L).
32Isolator SP 40Amp 240VAC (M&L).
33Wiring for circuit / submain wiring along with earth wire with 2X2.5 sqmm +1X1.5 sq. mm FR PVC insulated copper conductor single core
34Wiring for circuit / submain wiring along with earth wire with 2X4.0sqmm +1X2.5 sq. mm FR PVC insulated copper conductor single core
35Wiring for circuit / submain wiring along with earth wire with 2X6.0 sq mm +1X4.0sq. mm FR PVC insulated copper conductor single core
36S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as required.
37Rigid non-metallic PVC coduit 20mm dia exclusive of boxes (junction/terminal) but inclusive of all tees,bends,elbows,reducers,bell mouth tube ends and fixing accessories such as couplers,lock nuts, saddles, pipe hooks etc. (Fixing Only).
38Cutting chases for concealed conduit wiring etc and making good cutting not exe 10cm girth.
39Single pole and neautral sheet metal enclosure with a two pin and earth plug and socket complete with 20Amp single pole MCB.
40PVC insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 35 Sq. mm 3 & 1/2 core.

AI Tender Summary

OUR REF NO 44975708
AUTHORITY Government Departments
TENDER VALUE 47 Lakhs
LAST DATE 12-09-2024
Authority
Authority Name Ordnance Equipment Factory
Work Description Tender For Repair Or Renovation Of Electrical System Of Lcs Shop Of Boot Plant Inside Factory At Oefc
Basic Detail
Tender No CW/TE/E-Proc/17/OEF/EO/2024-25
Bidding Type Tender
Location
City kanpur
State Uttar Pradesh
Key Dates
Publish Date 29 Aug 2024
Submission Date 12 Sep 2024
Open Date 14 Sep 2024
Finance
Tender Value 47 Lakhs
Tender Fee Ref. Documents
EMD 94000
Exemption Not Available
Document List
Integrity_Pact17.pdf
TCC17.pdf
7debaeea-030b-4493-82df-6aa8fbc471ea.html
Annexure-C.PDF
BOQ_225733.xls
Checklist17.pdf
Compliance_format17.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 29, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 12, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 14, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Integrity_Pact17.pdf

pdf

TCC17.pdf

html

7debaeea-030b-4493-82df-6aa8fbc471ea.html

PDF

Annexure-C.PDF

xls

BOQ_225733.xls

pdf

Checklist17.pdf

pdf

Compliance_format17.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail