Feeder Segregation Of Balance Agriculture Feeders In Raebareli, Sitapur, Unnao, Badaun And Shahjahanpur Districts Of Mvvnl, Uttar Pradesh Under Rdss. - Overhead 11 kV Line 2 8.5 m/180 kgs PCC Poles (PCC Pole as per state practice) 3 Foundation of PCC Supports as per scope of works, cement concreting (1:3:6) (0.268 Cmt for each support) 4 Stone pad for supports as per scope of works & drawing (300x300x75 mm ) 5 11 KV V-Type Cross-arm (M.S Angel 65X65x6mm weight-10.37 kg) 6 Cross arm holding back clamps (MS Flat-50x8 mm, weight-1.33 kg) with bolts and nuts 7 F- Bracket MS flat (50x8 mm) (weight- 1.56 kg) with nut and bolts 8 Cut point top channel (100x50x6 mm) of length 1150 mm along with supporting clamp and nut-bolts 9 Bottom support channel for Cut point (100x50x6 mm) of length 230 mm along with supporting clamp and nut-bolts 10 DP Top channel (100X50x6mm) 2240 mm long with supporting clamp and nuts-bolts 11 Horizontal Belting Angle (Angle-50x50x6 mm) 2240 mm long with bolts and nuts 12 Cross bracing Angle (Angle-50x50x6 mm) 2500 mm long with bolts and nuts 13 Belting clamp-Top clamp (Flat-50x8 mm) (weight 1.4 kg) with bolts and nuts 14 Belting clamp-Bottom clamp (Flat-50x8 mm) (weight 1.5 kg) with bolts and nuts 15 11 KV polymer Disc insulator 45 KN (B&S type) along with suitable hardware fittings 16 Fish plate for jumpering 17 Phase wire 6/3.35 + 1/3.35 mm (50 sqmm Al. Area) ACSR Rabbit conductors 18 PG clamp for Rabbit conductor 19 Aluminium Jointing sleave for ACSR Rabbit 20 Aluminium binding wire and tape 21 11 KV Polymer Pin Insulators 5 KN with nuts 22 Earthing of poles using spike type 20 Ø G.I earthing Rod of 2500 mm as per approved drawings. 23 8 SWG GI wire for pole,DB earthing with GI nuts, bolts & washers 24 MS Danger board with Back calmps & nuts and boltsas per Technical specification 25 Anti-climbing device-1.5 kgs with supporting clamp, 2.5mm dia (12 SWG) galvanized barbed wire on each 11 kV support as per scope of works & TS 26 Numbering and scheme details on each pole as per Technical specification and scope of work 27 Tree Cutting Compensation 28 Existing 11KV/LT line Crossings 29 13 Meter long Steel Tubular Poles with welded steel base plate of designation 410 SP 72 (With two coat of redoxide paint from manufacturer as per SBD) 30 11 Meter long Steel Tubular Pples with welded steel base plate of designation 410 SP 55 (With two coat of redoxide paint from from manufacturer as per SBD) 31 Foundation of STP 13 M Supports as per scope of works, cement concreting (1:3:6) (0.63 Cu Mtr for each support) 32 Foundation of STP 11 M Supports as per scope of works, cement concreting (1:3:6) (0.44 Cu Mtr for each support) 33 Aluminium paint as per mentioned in SBD 34 Supporting channel (100x50x6 mm) 300 mm long for V-cross arm with holding back clamps and nut-bolts. 35 11 KV V-Type Cross-arm (M.S Channel 65X65x6mm, weight-10.37 kg) with holding back clamps (MS Flat-50x8 mm, weight-1.33 kg) and nut-bolts. 36 Guarding Cross arm (75x40x6 mm) 2210 mm long with eye bolts (16mm dia) 37 Back clamp for guarding cross arm (50x8 mm) (weight- 1.15 kg)with nut & bolts. 38 Cross arm holding clamps (MS Flat-50x8 mm) (weight-1.33 kg) with bolts and nuts 39 6 SWG GI wire along the span 40 8 SWG GI wire across the span 41 12 SWG GI wire for binding 42 11 KV Polymer Pin Insulators 5 KN with nuts 43 F-bracket MS flat (50X8 mm) (weight- 1.5 kg) for fitting top insulator with bolts & nuts 44 Barbed wire GI 45 Danger Plate with clamps & bolts 46 Earthing of poles using spike type 20 Ø G.I earthing Rod of 2500 mm as per approved drawings. 47 8 SWG GI wire for pole,DB earthing with GI nuts, bolts & washers 48 Supply & Installation of 11KV VCB Switchgear panel outgoing for outgoing feeders 49 11 KVVCB 50 11KV VCB Switchgear panel outgoing CTR 200/100/5A, 350 MVA 51 11 KV rearrangement for connecting new 11 KV VCB with existing 11 KV Switch gear (Adoptor Panel) 52 11 KV 3 core cable 53 Cable AL 3X185 sqmm XLPE 11 KV 54 Laying of 11 KV cable including cost of sand & bricks 55 11 KV cable jointing kit indoor 185 sq.mm. 56 11 KV cable jointing kit outdoor 185 sq.mm. 57 Control Cable 58 4x2.5 mm sq 59 2x2.5mm sq 60 Section double pole on 11 mtr STP 61 Controll Room Extension 62 Excavation in foundation in ordinary soil (Loam day or sand) including lift upto 1.5 mtr. And lead upto 30 m and including filling watering and ramming of excavated earth into the building and sides of the foundation trenches or in to the plinth and directed by the engineer-in-charge upto a distance of 30 m from the foundation 63 Concrete with 4 cm.gauge 1st class brick ballast (class 150) coarse sand (F.M.1.8 to 2.5) and cement in proportion of 10:5:1 in foundation and under floors including supply of all materials labour and T&P etc. required for propoer complrtion of work. 64 1st class brick work in 1:6 cement & coarse sand (F.M.1.8 to 2.5) morter in foundation & plinth including supply of all materials, labour and T&P etc. required for propoer complrtion of work. 65 1st class brick (class 150)work in 1:6 cement & coarse sand (FM 1.8 to 2.50) morter but in supper structure but for wall of one & half brick thick including supply of all materials , labour T&P etc required for propoer completion of work. 66 1st class brick (class 150) work in 1:6 cement & coarse sand (FM1.8 to 2.50) morter but in supper structure but for wall of one brick thick including supply of all material, labour T&P etc required for proper completion of work. 67 Mild steel or iron in plain work such as reinforced concrete or reinforced brick work (when not included in over all rate) wrought to required shape as necessary I/C bending for proper completion of the work & I/C supply of steel its wastege shall be measured stee! shall not be supplied by the department. 68 Mild steel or iron work in heavy sizes such as trusses built up gates, door frames, record racks roof work gates etc. wrought to required form including holes riveting or welding where necessary and also including supply of steel bolts nuts wastage etc.and their fixing required for proper completion of the work (steel is not supplies by the department) 69 R.C.C. work with cement approved coarse sand (P.M. 1.8 to 2.5)and 2 Cm gauge graded approved hard stone ballast in proportion 1:2:4 in lintels of doors & windows excluding supply of reinforcement and its bending but including its fixing & binding the same with 24 BWG G.I. binding wire and including necessary centring & shuttering etc. and also including cost of all materials, labour and T&P etc. required for proper completion of the work. 70 R.c.c. work with cement approved coarse sand (P.M. 1.8 to 2.5)and 2 Cm gauge graded approved hard stone ballast in proportion 1:1:5:3 for slab excluding supply of reinforcement and its bending but including its fixing & binding the same with 24 BWG G.I binding wire and I/C necessary centering & shuttering etc. and also I/C cost of all materials, labour and T&P etc. required for proper completion of the work. 71 12 MM thick plaster with cement morter consisting of 1 aart: Sparts of approved coarse sand on fare surface ncluding supply of all materials, labour T&P etc. required for proper completion of work. 72 Supply & fixing fan hooks 16 mm dia 200 mm long complete. 73 P/F glass strip of 40 mm depth in joints of floor and skirting at the time of laying, floors flush with floor level ncluding labour. Tools and plants etc. complete. 74 40 mm thick 1:2:4 floor without base concrete floor with cement, approved coarse sand &2 cm. graded approved stone ballast (shingle for bareily) laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and giving them a uniform finish including supply of all labour and T&P etc required for proper completion of work. 75 White washing three coats of new surface including cost of all materials, labour and T&P etc. required for proper completion of the work exept cost of angle iron and flat. 76 One priming coat and two coats of dry distemper castle or equivalent make on new surface including cost of all materials, labour and T&P etc. required for proper completion of the work. 77 Finishing walls with water proof cement paint of approved make and quality over new work with three coats to give an even shade including supply of all materials, labour and T&P etc.required for proper completion of the work. 78 Writing point for light with 1.5 sq.mm. FRPVC insulated multistrand single core copper conductor cable in surface conduit pipe, complete with copper earth continuity wire, piano type switch & ceiling rose/angle/button holder on 3mm thick phenolic aminated backelite-sheet etc. Complete in all respects, as directed including matching colour wash. 79 Wiring point for fan/fresh air fan (light duty exhaust fan) n PVC conduit with 1.5 sq.mm. FR PVC insulted multistrand copper condctor cable as earth wire drawn nside the conduit. 80 S/F Batten/Angle Holder of approved quality complete n all respect. 81 Painting or varnishing on new iron work in small areas or new wood work with one coat of ready mixed priming paint and two coats of approved superior quality ready mixed paint (Luxol) or equivalent brand or varnish I/C supply of all materials, labour T&P etc. required for proper completion of work.Paint to be used should conform I.S.103-1950 82 Dismantling brick work or stone work in time or cement mortar and including stacking of materials as directed by E/l within distance of 60mtr. 83 Dismantling Existing plaster including disposal of refuse as directed by E/l within a distance of 60 mtr. 84 Dismantling C.C brick or brick or granolithic floors including base concrete and including stacking of dismantled material as directed by E/l within a distance of 60 mtr. 85 Railway Crossing 86 11 KV under ground railway crossing by 2 nos (including one spare) 3CX185 sqmm XLPE Armoured Cable using 150mm dia GI pipes (grade A for underground laying and grade B for Pole support), with 11 KV XLPE Cable in G.I. Pipe on double pole with sutiable clapms, nut & bolts, Outdoor Heat Shrinkable cable jointing kits, Lugs, 4 nos GI 3-Meter long pipe, Erathing, 8 SWG GI wires, cable markers, Bi metalic clamps, Jumpering, as required as per technical specifications, Drawings and Scope of the work. 87 11 KV Line crossing on double pole (11 Meter long Steel Tubular Poles with welded steel base plate of designation 410 SP 55) with two coat of redoxide paint from from manufacturer as per SBD 88 Foundation of STP Supports as per scope of works, cement concreting (1:3:6) (0.5 Cmt for each support and 0.014 cmt for muffing) 89 Aluminium paint as per mentioned in SBD 90 DP Top channel (100X50x6mm) 2240 mm long with supporting back clamps and nuts-bolts 91 Horizontal Belting Angle (Angle-50x50x6 mm) 2240 mm long with bolts and nuts 92 Cross bracing Angle (Angle-50x50x6 mm) 2500 mm long with bolts and nuts 93 Belting clamp- Top clamp (Flat-50X8 mm) (wieght 1.4 kg) with bolts and nuts 94 Belting clamp- Bottom clamp (Flat-50X8 mm) (wieght 1.5 kg) with bolts and nuts 95 Fish plate for jumpering 96 11 KV Polymer Pin Insulators 5 KN with nuts 97 9 KV, 10KA station class Lighting Arrester 98 Supply of 11 kV XLPE insulated Al. UG cable of size 3Cx185 mm2 99 Supply and Erection of Aluminium lugs-185 Sq.mm 100 Heat Shrinkable Jointing Kit Outdoor for 11 KV 3x185 sq. mm XLPE Cable 101 Hoisting of 3CX185 sqmm of 11 KV single cable on erected double pole including GI pipe 3 mtr long 6 dia including jumpering, dressing of cable with required all necessary clamps and nut, bolts. (all the materials shall be arranged by Bidders) 102 Earth digging minimum 3 meters below the Railway track by Horizontal Drilling (HDD) Method for laying, termination/jointing, erection of underground 11 KV grade 3-Core 185 Sqmm XLPE power cable in G.I. Pipes as per TS / approved drwaings. 103 Digging of Trench by excavation of earth, laying of bricks to cover the cable and filling of sand & earth ramming and dressing properly with complete job for laying 11 KV XLPE cables including cost of Bricks, sand, clamps etc. 104 G.I. Pipe (6 dia.) for for laying UG below the Railway track by HDD Method. 105 Supply and erection of 11 KV single core 95 sqmm XLPE Aluminium cable for jumpering 106 Testing and Commissioning of 11 KV grade 3-core 185 sqmm XLPE power underground cable 107 Earthing of poles using spike type 20 Ø G.I earthing Rod of 2500 mm as per approved drawings. 108 8 SWG GI wire for pole,DB earthing with GI nuts, bolts & washers 109 MS Danger board with Back calmps & nuts and boltsas per Technical specification 110 Anti-climbing device-1.5 kgs with supporting clamp, 2.5mm dia (12 SWG) galvanized barbed wire on each 11 kV support as per scope of works & TS 111 Numbering and scheme details on each pole as per Technical specification and scope of work 112 11 KV Polymer Disc insulator 45 KN (B&S type) along with suitable hardware fittings 113 PG clamp for Rabbit conductor 114 Railway crossing documentation and approval fee etc. as per actual on submission on requiste documents of concern department. 115 National Highway Crossing 116 11 KV under ground National Highway crossing by 2 nos (including one spare) 3CX185 sqmm XLPE Armoured Cable using 150mm dia GI pipes (grade A for underground laying and grade B for Pole support), with 11 KV XLPE Cable in G.I. Pipe on double pole with sutiable clapms, nut & bolts, Outdoor Heat Shrinkable cable jointing kits, Lugs, Erathing, 8 SWG GI wires, cable markers, Bi metalic clamps, Jumpering, as required as per technical specifications, Drawings and Scope of the work. 117 11 kV Line crossing on double pole (11 Meter long Steel Tubular Poles with welded steel base plate of designation 410 SP 55) with two coat of redoxide paint from from manufacturer as per SBD 118 Foundation of STP Supports as per scope of works, cement concreting (1:3:6) (0.5 Cmt for each support & 0.014 cmt for muffing) 119 Aluminium paint as per mentioned in SBD 120 DP Top channel (100X50x6mm) 2240 mm long with supporting back clamp and nuts and bolts 121 Horizontal Belting Angle (Angle-50x50x6 mm) 2240 mm long with bolts and nuts 122 Cross bracing Angle (Angle-50x50x6 mm) 2500 mm long with bolts and nuts 123 Belting clamp- Top clamp (Flat-50X8 mm) (wieght 1.4 kg) with bolts and nuts 124 Belting clamp- Bottom clamp (Flat-50X8 mm) (wieght 1.5 kg) with bolts and nuts 125 Fish plate for jumpering 126 11 KV Polymer Pin Insulators 5 KN with nuts 127 9KV, 10KA station class Lighting Arrester 128 Supply of 11 kV XLPE insulated Al. UG cable of size 3Cx185 mm2 129 Heat Shrinkable Jointing Kit Outdoor for 11 KV 3x185 sq. mm XLPE Cable 130 Hoisting of 3CX185 sqmm of 11 KV single cable on erected double pole including GI pipe 3 mtr long 6 dia including jumpering, dressing of cable with required all necessary clamps and nut, bolts. (all the materials shall be arranged by Bidders) 131 Earth digging below the National Highway by Horizontal Drilling (HDD) Method for laying, termination/jointing, erection of underground 11 KV grade 3-Core 185 Sqmm XLPE power cable as per TS / approved drwaings 132 Digging of Trench by excavation of earth, laying of bricks to cover the cable and filling of sand & earth ramming and dressing properly with complete job for laying 11 KV XLPE cables including cost of Bricks, sand, clamps etc. 133 Supply & Erection of Aluminium lugs-185 Sq.mm 134 Pipe HDPE having 160 mm dia for for laying UG below the National Highway by HDD Method. 135 Supply & erection of 11 KV single core 95 sqmm XLPE Aluminium cable for jumpering 136 Testing & Commissioning of 11 KV grade 3-core 185 sqmm XLPE power underground cable 137 Earthing of poles using spike type 20 Ø G.I earthing Rod of 2500 mm as per approved drawings. 138 8 SWG GI wire for pole,DB earthing with GI nuts, bolts & washers 139 MS Danger board with Back calmps & nuts and boltsas per Technical specification 140 Anti-climbing device-1.5 kgs with supporting clamp, 2.5mm dia (12 SWG) galvanized barbed wire on each 11 kV support as per scope of works & TS 141 Numbering and scheme details on each pole as per Technical specification and scope of work 142 11 KV Polymer Disc insulator 45 KN (B&S type) along with suitable hardware fittings 143 PG clamp for Rabbit conductor 144 National Highway crossing documentation and approval fee etc. as per Actual 145 G.I. Pipe 6 dia. with Clamps 146 Road Restoration Charges etc. as per actual on submission on requiste documents of concern department. 147 Distribution transformers 148 9 M / 400 kgs WL PCC Poles (PCC Pole as per state practice) 149 Foundation of PCC Supports as per scope of works, cement concreting (1:3:6) (0.268 Cmt for each support) 150 Stone pad for supports as per scope of works & drawing (300x300x75 mm ) 151 Transformer Top channel MS (100x50x6mm) 2800 mm long with supporting back clamps and nut-bolts 152 AB switch mounting channel (100x50x6mm) 2800 mm long with nuts & bolts 153 Back clamp for AB switch mounting channel(50x8mm)- (weight-1.8 kg) with nuts & bolts 154 DO fuse mounting channel (75x40x6mm) 2800 mm long with nuts & bolts 155 Back clamp for DO fuse mounting channel(50x8mm)- (weight-1.9 kg) with nuts & bolts 156 Tapping horizontal cross arm (100x50x6 mm) of length 1020 mm along with calmps (50x8) and nut and bolts 157 Tapping bottom channel (100x50x6 mm) of length 256 mm along with calmps(50x8) and nut and bolts 158 PG clamp for Rabbit conductor 159 Transformer mounting channel (100x50x6mm) 2800 mm with nuts & bolts 160 Transformer mounting channel support (50x50x6mm) 500 mm long with Nuts & bolts. 161 Transformer Belting angle (50x50x6mm) 2800 mm long with nuts & bolts 162 Transformer Belting angle support (35x35x6 mm) 500 mm long with nuts & bolts 163 11 KV polymer Disc insulator 45 KN (T&C type) along with suitable hardware fittings 164 11 KV Polymer Pin Insulators 5 KN with nuts 165 11/0.4 kV Distribution Transformer 25 KVA Three Phase aluminum wound DTR with high grade CRGO Core (Energy Efficiency Level-1 specified in IS 1180 (Part-1):2014 as per latest amendment 4 March 2021) 166 Tree Cutting Compensation 167 ACSR weasel counductor for Jumpering 168 Bimetallic connector for HT & LT side of the transformer 169 T clamp & PG clamp for jumpering 170 E Bracket MS flat (50X8mm) with nuts & bolts 171 LT Distribution box polyester sheet moulding compound (SMC) for 25 kVA Distribution transformer with arrangement of suitable bus-bars & MCCBs, DB with suitable Back clamp support (2 Nos) for LTDB ( 65x8 mm) as per scope of works of SBD 172 1Cx35 sqmm 1.1KV XLPE cable with suitable lugs and glands and cable ties 173 Suitable clamps for LT service cable support 174 9 kV, 5 KA distribution class LA 175 11 kV, 3-ph, 200 A, 3 Pin type Vertical Mounting typeAB Switch along with Support Insulators, Base Channel, down Pipe, operating handle and support, etc. complete asper technical specifications, scope of works and approved drawings 176 11 kV, 3-ph, Drop Out fuse Set (set of 3 units) along with Support Insulators, Base Channel, fuse barrel etc. complete asper technical specifications, scope of works and approved drawings 177 GI Earthing pipe of 40 mm dia & 3000 mm long as per IS 1161 178 GI flat (25x3 mm) 179 Earthing of poles using spike type 20 Ø G.I earthing Rod of 2500 mm as per approved drawings. 180 8 SWG GI wire for pole,DB earthing with GI nuts, bolts & washers 181 MS Danger board with Back calmps & nuts and bolts as per Technical specification 182 Anti-climbing device-1.5 kgs, 2.5mm dia (12 SWG) galvanized barbed wire on each 11 kV support as per scope of works & TS 183 Numbering and scheme details on each pole as per Technical specification and scope of work 184 LT line 185 8.5 m/180 kgs PCC Poles (PCC Pole as per state practice) 186 Foundation of PCC Supports as per scope of works, cement concreting (1:3:6) (0.268 Cmt for each support) 187 Stone pad for supports as per scope of works & drawing (300x300x75 mm ) 188 Aerial Bunched XLPE Cable 3X50 (Ph) + 1X35 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm 189 LT pole clamp (50x8mm) (2.56 kg) with Nut and bolts for laying of ABC 190 Dead end clamp with Eye hook 191 suspension clamp with Eye hook 192 PG clamp for(For line to line jumpering of bare messenger cum neutral wire of LT Aerial Bunched Cable(ABC) & energizing DB Neutral) 193 LT Insulation Piercing connectors type-II of 16-95 sqmm size for energizing distibution Kiosk/box (AB cable to Service cable) 194 Insulation Piercing connectors/Connector type-I (AB cable to AB cable) 195 2Cx25 sqmm XLPE aluminium conductor cable for single phase DB incomer 196 4Cx35 sqmm XLPE aluminium conductor cable for Three phase DB incomer 197 Single phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC) Pole top distribution box with calmps (40x3 mm) and nut & bolts 198 Three phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC)Pole top distribution box with calmps (40x3 mm) and nut & bolts 199 Earthing of poles using spike type 20 Ø G.I earthing Rod of 2500 mm as per approved drawings. 200 8 SWG GI wire for pole,DB earthingwith GI nuts, bolts & washers 201 Stay Set (Galvanised) with 50x8 mm stay clamps, guy insulator , anchor plate (200x200x6mm) , nut bolts, 1 Nos turn-buckle, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work including foundation of stay support in each stay set as per scope of works 202 Stay Rod 16x1800 mm complete as per Technical specification, scope of work and tender drawing 203 Stay Wire 7/10 SWG 204 Stay Clamp- (Flat-50x8 mm) (weight-1.5 kg)with bolts and nuts 205 Stay Guy insulator LT 206 Stay Guy insulator HT (11 KV) 207 Stay thimble 208 Hellically formed end fitting 209 Concreting of Stay Rod (0.2 cmt cement concreting in mixture (1:3:6)