Public Administrative Department Government Departments Closing in 0 days TDR #44930445

Tender For Repair And Renovation Of Power House Building At Chowra Island Sw Providing Iei

Issued by Government Departments · PORT Blair, Andaman And Nicobar Islands
Tender Value
3.17 Lakhs
Estimated cost
Bid Submission
06 Sep 2024
0 days left
EMD
6353
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
PORT Blair → Andaman And Nicobar Islands
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair And Renovation Of Power House Building At Chowra Island Sw Providing Iei , Wiring For Light Point/Fan Point/Exhaust Fan Point/Call Bell Point With 1.5 Sqmm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/Recessed Medium Class Pvc Conduit With Modular Switch, Modular Plate Suitable Gi Box And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Reqd. , GroupC , Wiring For Light/ Power Plug With 2 X 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit Alongwith 1 No 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Pvc Conduit As Required , 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire , 4 X 4 Sq. Mm + 2 X 4 Sq. Mm Earth Wire , 4 X 6 Sq. Mm + 2 X 6 Sq. Mm Earth Wire , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Reqd. , A) 20Mm , Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5/6 & 15/16 A Modular Socket Outlet And 15/16 A Modular Switch, Connections Etc. As Required. , Supplying And Fixing 3 Pin, 5 Amp Ceiling Rose On The Existing Junction Box/ Wooden Block Including Connection Etc As Required , Supplying And Fixing Pvc Batten/ Angle Holder Including Connection Etc. As Required. , Installation Testing And Commissioning Ofwall Bracket /Ceiling Fittings Of All Sizes And Shapes Containing Upto Two Gls Lamps Per Fitting, Complete With All Accessories Including Connection Etc. As Required. , Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rods Of Standard Length (Upto 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required , Installation Of Exhaust Fan In The Existing Opening Including Making Good The Damage Connection Testing Commissioning Etc As Reqd. , A) Upto 450Mm Sweep , Extra For Fixing The Louvers/Shutters Complete With Frame For A Exhaust Fan Of All Size , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing 2 Nos, 3 Pin 5/6 Amps Modular Socket Outlet And 2 Nos 5/6 Amps Modular Switches Connection Etc As Reqd (For Light Plugs To Be Used In Non Residential Building) , Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) , A) 4 Way, (4+12),Double Door , Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, 10 Ka, “C” Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required , Single Pole , Supplying And Fixing Following Rating,Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , 63 Amps , Providing And Laying Earth Connection From Earth Electrode With 4.00 Mm Dia Copper Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With Copper Thimble Excavation And Re-Filling As Required , Providing And Fixing 4.00 Mm Dia Copper Wire On Surface Or In Recess For Loop Earthing As Required , Supplying Installation, Testing And Commissioning Of Ashlok Make See Brand Safe Earthing Electro Type-19, 50Mm Dia Length 2 Mtrs And Inner Space To Be Filled With Crystaline Conductive Mixture Including Filling Up With Elelctrodite (Back Fill Compound ) As Reqd For Safe Earth Electrode And Providing Masonary Enclusure With Cover Plate Having Locling Arrangement Etc As Reqd. , Supply Ofled Floodlight 30 Watt Similar To Crompton Gleam 30 Watt Outdoor Waterproof( Cool Day Light 6500K) Or Equivalent To Isi Specification , Supplying Of Ip66 Led Floodlight 100 Watts Similar To Wipro Garnet 100 W 6500 K Or Its Equivalent To Is Specification , Sitc Of Air Circular Wall Fan Of Size 450Mm Sweep Metallic Blade With Protective Guard Similar To Havells Turbo Force Or Equivalent To Isi Specification , Supplying Of Heavy Duty Exhaust Fan Of Size 450Mm Sweep Metallic Blades With Protective Bird Guard (Similar To Havells Turbo Force Sp 1400 Rpm Or Equivalent To Isi Specification. , Supply Of Led Lighting Fixture With Extruded Polycarbonate Of 18 Watts Similar To Havells E-Lite Led Pride Plus Cat No: Lhexblp5pn1w018 Or Its Equivalent To Isi Specification. , Supply Of Led Bulb Of 9 Watts Of Syska Ssk -Srl Or Equivalent To Isi Specification. , Supplying Ofenergy Saving 5 Star Rating, With Isi,A.C. Ceiling Fan 1200 Mm Sweep, With All Accessories(Similar To Plycab Eteri Energy Efficient Bldc5 Star)Or Equivalent

BOQ

Name of Work :Repair & Renovation of power house building at Chowra Island. Sub Work:- Providing IEI.
Sl. No. Item Description
1Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit with modular switch, modular plate suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as reqd.
2Group\"C\"
3Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
4Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required
52 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
64 X 4 sq. mm + 2 X 4 sq. mm earth wire
74 X 6 sq. mm + 2 X 6 sq. mm earth wire
8Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as reqd.
9a) 20mm
10Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
11Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
12Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required
13Supplying and fixing PVC batten/ angle holder including connection etc. as required.
14Installation testing and commissioning ofwall bracket /ceiling fittings of all sizes and shapes containing upto two GLS lamps per fitting, complete with all accessories including connection etc. as required.
15Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required
16Installation of exhaust fan in the existing opening including making good the damage connection testing commissioning etc as reqd.
17a) upto 450mm sweep
18Extra for fixing the louvers/shutters complete with frame for a exhaust fan of all size
19Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 2 nos, 3 pin 5/6 amps modular socket outlet and 2 nos 5/6 amps modular switches connection etc as reqd (For light plugs to be used in non residential building)
20Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
21a) 4 way, (4+12),Double door
22Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
23Single Pole
24Supplying and fixing following rating,four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2563 Amps
26Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required
27Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required
28Supplying installation, testing and commissioning of ASHLOK make SEE brand safe earthing electro type-19, 50mm dia length 2 mtrs and inner space to be filled with crystaline conductive mixture including filling up with elelctrodite (Back fill compound ) as reqd for safe earth electrode and providing masonary enclusure with cover plate having locling arrangement etc as reqd.
29Supply ofLED Floodlight 30 Watt similar to Crompton Gleam 30 watt Outdoor waterproof( Cool day light 6500K) or equivalent to ISI specification
30Supplying of IP66 LED floodlight 100 watts similar to Wipro Garnet 100 W 6500 K or its equivalent to IS specification
31SITC of Air circular wall fan of size 450mm sweep metallic blade with protective guard similar to Havells Turbo Force or equivalent to ISI specification
32Supplying of Heavy Duty Exhaust fan of size 450mm sweep metallic blades with protective bird guard (Similar to Havells Turbo Force SP 1400 RPM or equivalent to ISI specification.
33Supply of LED lighting fixture with extruded polycarbonate of 18 Watts similar to Havells E-Lite LED Pride Plus Cat No: LHEXBLP5PN1W018 or its equivalent to ISI specification.
34Supply of LED bulb of 9 Watts of SYSKA SSK -SRL or equivalent to ISI specification.
35Supplying ofEnergy Saving 5 star rating, with ISI,A.C. Ceiling fan 1200 mm sweep, with all accessories(Similar to Plycab Eteri Energy Efficient BLDC5 Star)or equivalent

AI Tender Summary

OUR REF NO 44930445
AUTHORITY Government Departments
TENDER VALUE 3.17 Lakhs
LAST DATE 06-09-2024
Authority
Authority Name Andaman Public Works Dept
Work Description Repair And Renovation Of Power House Building At Chowra Island Sw Providing Iei , Wiring For Light Point/Fan Point/Exhaust Fan Point/Call Bell Point With 1.5 Sqmm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/Recessed Medium Class Pvc Conduit With Modular Switch, Modular Plate Suitable Gi Box And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Reqd. , GroupC , Wiring For Light/ Power Plug With 2 X 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit Alongwith 1 No 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Pvc Conduit As Required , 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire , 4 X 4 Sq. Mm + 2 X 4 Sq. Mm Earth Wire , 4 X 6 Sq. Mm + 2 X 6 Sq. Mm Earth Wire , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Reqd. , A) 20Mm , Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5/6 & 15/16 A Modular Socket Outlet And 15/16 A Modular Switch, Connections Etc. As Required. , Supplying And Fixing 3 Pin, 5 Amp Ceiling Rose On The Existing Junction Box/ Wooden Block Including Connection Etc As Required , Supplying And Fixing Pvc Batten/ Angle Holder Including Connection Etc. As Required. , Installation Testing And Commissioning Ofwall Bracket /Ceiling Fittings Of All Sizes And Shapes Containing Upto Two Gls Lamps Per Fitting, Complete With All Accessories Including Connection Etc. As Required. , Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rods Of Standard Length (Upto 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required , Installation Of Exhaust Fan In The Existing Opening Including Making Good The Damage Connection Testing Commissioning Etc As Reqd. , A) Upto 450Mm Sweep , Extra For Fixing The Louvers/Shutters Complete With Frame For A Exhaust Fan Of All Size , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing 2 Nos, 3 Pin 5/6 Amps Modular Socket Outlet And 2 Nos 5/6 Amps Modular Switches Connection Etc As Reqd (For Light Plugs To Be Used In Non Residential Building) , Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) , A) 4 Way, (4+12),Double Door , Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, 10 Ka, “C” Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required , Single Pole , Supplying And Fixing Following Rating,Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , 63 Amps , Providing And Laying Earth Connection From Earth Electrode With 4.00 Mm Dia Copper Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With Copper Thimble Excavation And Re-Filling As Required , Providing And Fixing 4.00 Mm Dia Copper Wire On Surface Or In Recess For Loop Earthing As Required , Supplying Installation, Testing And Commissioning Of Ashlok Make See Brand Safe Earthing Electro Type-19, 50Mm Dia Length 2 Mtrs And Inner Space To Be Filled With Crystaline Conductive Mixture Including Filling Up With Elelctrodite (Back Fill Compound ) As Reqd For Safe Earth Electrode And Providing Masonary Enclusure With Cover Plate Having Locling Arrangement Etc As Reqd. , Supply Ofled Floodlight 30 Watt Similar To Crompton Gleam 30 Watt Outdoor Waterproof( Cool Day Light 6500K) Or Equivalent To Isi Specification , Supplying Of Ip66 Led Floodlight 100 Watts Similar To Wipro Garnet 100 W 6500 K Or Its Equivalent To Is Specification , Sitc Of Air Circular Wall Fan Of Size 450Mm Sweep Metallic Blade With Protective Guard Similar To Havells Turbo Force Or Equivalent To Isi Specification , Supplying Of Heavy Duty Exhaust Fan Of Size 450Mm Sweep Metallic Blades With Protective Bird Guard (Similar To Havells Turbo Force Sp 1400 Rpm Or Equivalent To Isi Specification. , Supply Of Led Lighting Fixture With Extruded Polycarbonate Of 18 Watts Similar To Havells E-Lite Led Pride Plus Cat No: Lhexblp5pn1w018 Or Its Equivalent To Isi Specification. , Supply Of Led Bulb Of 9 Watts Of Syska Ssk -Srl Or Equivalent To Isi Specification. , Supplying Ofenergy Saving 5 Star Rating, With Isi,A.C. Ceiling Fan 1200 Mm Sweep, With All Accessories(Similar To Plycab Eteri Energy Efficient Bldc5 Star)Or Equivalent
Basic Detail
Tender No 02/NIT/DB/CD/KMT/2024-25
Bidding Type Tender
Location
City PORT Blair
State Andaman And Nicobar Islands
Key Dates
Publish Date 27 Aug 2024
Submission Date 06 Sep 2024
Open Date 06 Sep 2024
Finance
Tender Value 3.17 Lakhs
Tender Fee Ref. Documents
EMD 6353
Exemption Not Available
Document List
1b870e2c-ede4-40d8-9120-acd59ea26170.html
BOQ_16209.xls
edoc.pdf
Instructions-to-bidders.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 27, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 06, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 06, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

1b870e2c-ede4-40d8-9120-acd59ea26170.html

xls

BOQ_16209.xls

pdf

edoc.pdf

pdf

Instructions-to-bidders.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender