Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 02-09-2024 | Corrigendum NO 01 for this office NIT NO 01/2024-25 | Other | 24-09-2024 |
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils |
| 2 | 100 mm dia pipe |
| 3 | 150 mm dia pipe |
| 4 | 200 mm dia pipe |
| 5 | 250 mm dia pipe |
| 6 | 300 mm dia pipe |
| 7 | 350 mm dia pipe |
| 8 | 400 mm dia pipe |
| 9 | 450 mm dia pipe |
| 10 | 600 mm dia pipe |
| 11 | 700 mm dia pipe |
| 12 | Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctileIron(DI)ISI markedK-7gradeS&Spipesas per IS:8329-2000 (amendeduptodate),withinternalcementmortar lining suitable for potablewater with rubber ring (EPDM)joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 13 | 100 mm dia pipe |
| 14 | 150 mm dia pipe |
| 15 | 200 mm dia pipe |
| 16 | 250 mm dia pipe |
| 17 | 300 mm dia pipe |
| 18 | 350 mm dia pipe |
| 19 | 400 mm dia pipe |
| 20 | 450 mm dia pipe |
| 21 | 600 mm dia pipe |
| 22 | 700 mm dia pipe |
| 23 | Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-9 grade S&S pipes as per 15:8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382- 1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ I.I unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 24 | 100 mm dia pipe |
| 25 | 150 mm dia pipe |
| 26 | Providing, lowering, aligning, fixing in position and Jointing in pipe line, combination Air Release Valve Kinetic type with single chamber housed Double orifice and have 3 functions, large Air exhaust, small Air venting and large air intake during vacuum of pipeline of approved makes of following pressure rating and dia and as per following specifications:Governing standard - AWWA C512 ,Body and bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865,Float & internal trim: AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBRDrilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & coverinside and outside Fasteners - CS/ Galvanised steel ,Outlet of big orifice will have a screen to prevent Tamper of float, Big orifice size should be equal or larger than the inlet flange bore, for fully comply with AWWA C512.), Valve including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. |
| 27 | 50 mm dia |
| 28 | 80 mm dia |
| 29 | 100 mm dia |
| 30 | Construction of Air valve pillar for fixing of Air valves |
| 31 | Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Manually Operated Resilient Seated Sluice Valves of Class PN 1.0/1.6 |
| 32 | 100 mm dia |
| 33 | 150 mm dia |
| 34 | 200 mm dia |
| 35 | 250 mm dia |
| 36 | 300 mm dia |
| 37 | Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amendedup to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/316 & shaft bearings-bronze/ PTET or Teflon with EPDM/NBR \"O\" ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Class PN 1.0/1.6 Manually Operated with Gear Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 38 | 350 mm dia |
| 39 | 400 mm dia |
| 40 | 450 mm dia |
| 41 | 600 mm dia |
| 42 | 700 mm dia |
| 43 | Cosntruction of valve chamber for Sluice Valves, Flow Control Valve and Butterfly valve as per approved drawing and specifications to the satisfaction of Engineer-in-charge |
| 44 | Type - C (250 mm to 350 mm dia) |
| 45 | Type - D (400 mm to 450 mm dia) |
| 46 | Type - E (500 mm to 600 mm dia) |
| 47 | Type - F (650 mm to 750 mm dia) |
| 48 | Cosntruction of Scour valve chamber as per approved drawing and specifications to the satisfaction of Engineer-in-charge |
| 49 | Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer. |
| 50 | 100 mm dia |
| 51 | 150 mm dia |
| 52 | 200 mm dia |
| 53 | 250 mm dia |
| 54 | 300 mm dia |
| 55 | 350 mm dia |
| 56 | 400 mm dia |
| 57 | 450 mm dia |
| 58 | 600 mm dia |
| 59 | 700 mm dia |
| 60 | Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved byauthority specification and the direction of the Engineer.Apply corrosion, resistant, protection on inside and outside of casing pipeas per technical specification. |
| 61 | 600 mm dia |
| 62 | Providing, laying and jointing RCC NP4pipe with cement mortar joints by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per the direction of NHAI including carrying out survey work at the job site for determining underground cable trenches like telephone, power cable, water & sanitary lines and resistivity tests for finding the soil strata using necessary equipments for completion of work, mobilizing of machineries and specialized crew at the job site, etc. complete in all respects,including excavation of drive pit and exit pit (upto 3 metre depth) with proper protection at the three sides, providing and casting of MS cutting edges for front shield and constructingthrustbedatdesignedlevelasdirectedbythe Engineer,necessaryde-wateringandprovidingconcrete foundations at the base of the Drive pit, crane for handling of pipes, and any other machinery, tool & tackels required, construction of temporaryworksasperrequirementandasapprovedbyNH authorities complete in all respect for the road crossing at necessary depth (all depths) with all lead and lifts, as per secification and the direction ofthe Engineer |
| 63 | 600 mm dia |
| 64 | Dismantling of flexible pavement for pipe lineand chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be madefor trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work. |
| 65 | Bituminous courses |
| 66 | Granular courses |
| 67 | Provision for Restroration of Bitumen Road after laying & jointing pipe line as per direction of Engineer In charge |
| 68 | SURGE PROTECTION MEASURES Provision for Design,Supply andinstallation of suitable Surge Protection Devices to protect the Pumping main includingallmaterial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer etc,complete in all respect. |
| 69 | Providing, lowering, aligning, fixing in position and Jointing in pipe line, combination Air Release Valve Kinetic type with single chamber housed Double orifice and have 3 functions, large Air exhaust, small Air venting and large air intake during vacuum of pipeline of approved makes of following pressure rating and dia and as per following specifications:Governing standard - AWWA C512 ,Body and bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865,Float & internal trim: AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBRDrilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & coverinside and outside Fasteners - CS/ Galvanised steel ,Outlet of big orifice will have a screen to prevent Tamper of float, Big orifice size should be equal or larger than the inlet flange bore, for fully comply with AWWA C512.), Valve including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. |
| 70 | 50 mm dia |
| 71 | Construction of Air valve pillar for fixing of Air valves |
| 72 | Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Manually Operated Resilient Seated Sluice Valves of Class PN 1.0/1.6 |
| 73 | 100 mm dia |
| 74 | 150 mm dia |
| 75 | 200 mm dia |
| 76 | Cosntruction of valve chamber for Sluice Valves as per approved drawing and specifications to the satisfaction of Engineer-in-charge |
| 77 | Type - A (80 mm to 100 mm dia) |
| 78 | Type - B (125 mm to 200 mm dia) |
| 79 | Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer. |
| 80 | 100 mm dia |
| 81 | 150 mm dia |
| 82 | 200 mm dia |
| 83 | Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved byauthority specification and the direction of the Engineer.Apply corrosion, resistant, protection on inside and outside of casing pipeas per technical specification. |
| 84 | 400 mm Dia 8 mm thick casing pipe with protective coating. |
| 85 | Providing, laying and jointing RCC NP4pipe with cement mortar joints by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per the direction of NHAI including carrying out survey work at the job site for determining underground cable trenches like telephone, power cable, water & sanitary lines and resistivity tests for finding the soil strata using necessary equipments for completion of work, mobilizing of machineries and specialized crew at the job site, etc. complete in all respects,including excavation of drive pit and exit pit (upto 3 metre depth) with proper protection at the three sides, providing and casting of MS cutting edges for front shield and constructingthrustbedatdesignedlevelasdirectedbythe Engineer,necessaryde-wateringandprovidingconcrete foundations at the base of the Drive pit, crane for handling of pipes, and any other machinery, tool & tackels required, construction of temporaryworksasperrequirementandasapprovedbyNH authorities complete in all respect for the road crossing at necessary depth (all depths) with all lead and lifts, as per secification and the direction ofthe Engineer |
| 86 | 300 mm dia |
| 87 | 400 mm dia |
| 88 | Dismantling of flexible pavement for pipe lineand chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be madefor trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work. |
| 89 | Bituminous courses |
| 90 | Granular courses |
| 91 | Provision for Restroration of Bitumen Road after laying & jointing pipe line as per direction of Engineer In charge |
| 92 | Providing, lowering, aligning, fixing in position and Jointing in pipe line, combination Air Release Valve Kinetic type with single chamber housed Double orifice and have 3 functions, large Air exhaust, small Air venting and large air intake during vacuum of pipeline of approved makes of following pressure rating and dia and as per following specifications:Governing standard - AWWA C512 ,Body and bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865,Float & internal trim: AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBRDrilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & coverinside and outside Fasteners - CS/ Galvanised steel ,Outlet of big orifice will have a screen to prevent Tamper of float, Big orifice size should be equal or larger than the inlet flange bore, for fully comply with AWWA C512.), Valve including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. Class PN 1.6 |
| 93 | 50 mm dia |
| 94 | Construction of Air valve pillar for fixing of Air valves |
| 95 | Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Manually Operated Resilient Seated Sluice Valves of Class PN 1.0/1.6 |
| 96 | 100 mm dia |
| 97 | 150 mm dia |
| 98 | 200 mm dia |
| 99 | 250 mm dia |
| 100 | 300 mm dia |
| 101 | Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesof approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitablesupport structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Manually Operated CI Sluice Valves of Class PN 1.0 Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 102 | 80 mm dia |
| 103 | 100 mm dia |
| 104 | 125 mm dia |
| 105 | 150 mm dia |
| 106 | 200 mm dia |
| 107 | 250 mm dia |
| 108 | 300 mm dia |
| 109 | Cosntruction of valve chamber for Sluice Valves as per approved drawing and specifications to the satisfaction of Engineer-in-charge |
| 110 | Type - A (80 mm to 100 mm dia) |
| 111 | Type - B (125 mm to 200 mm dia) |
| 112 | Type -C (250 mm to 350 mm dia) |
| 113 | Construction of Village Transfer Chamber as per approved design, drawing & specification given for material of construction and completion of all works of installation of sluice valves, D.joints, C.I. pipes, specials (excluding supply)etc. complete in all respect to achieve the work as given in the scope of work. |
| 114 | Type-A |
| 115 | Type-B |
| 116 | Providing, lowering,aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specificationscompleteofthefollowingsizesincludingall jointing material,costofalllabour,testingandcommissioningand as per technical specifications and direction of Engineer In-Charge. Class PN 1.0/1.6 |
| 117 | 80 mm dia |
| 118 | 100 mm dia |
| 119 | 125 mm dia |
| 120 | 150 mm dia |
| 121 | 200 mm dia |
| 122 | 250 mm dia |
| 123 | 300 mm dia |
| 124 | Provision for Construction of flow meter hut of size 2.5*2.5*2.8 m for installation of FM display, battery, power meter etc. at each OHSR complete in all respect as per approved drawing. |
| 125 | Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: - |
| 126 | a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc.c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR.The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil.d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall.e)Conducting successfully hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome.g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc..h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab.j) Providing and fixing water level indicator (float type). |
| 127 | k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres.l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide.m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall).n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground.o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm.p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir.q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. |
| 128 | Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-III & STAGING 15 M |
| 129 | 75 KL |
| 130 | Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-III & STAGING 18 M |
| 131 | 100 KL |
| 132 | 150 KL |
| 133 | 200 KL |
| 134 | 250 KL |
| 135 | 300 KL |
| 136 | 350 KL |
| 137 | Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-III & STAGING 20 M |
| 138 | 100 KL |
| 139 | 200 KL |
| 140 | 250 KL |
| 141 | 300 KL |
| 142 | 350 KL |
| 143 | 400 KL |
| 144 | Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-III & STAGING 22 M |
| 145 | 200 KL |
| 146 | 250 KL |
| 147 | 350 KL |
| 148 | Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. |
| 149 | 100 mm dia |
| 150 | 150 mm dia |
| 151 | 200 mm dia |
| 152 | 250 mm dia |
| 153 | 300 mm dia |
| 154 | Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN- 1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG- 400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Manually Operated Resilient Seated Sluice Valves of Class PN 1.0/1.6 |
| 155 | 100 mm dia |
| 156 | 150 mm dia |
| 157 | 200 mm dia |
| 158 | 250 mm dia |
| 159 | 300 mm dia |
| 160 | Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer. |
| 161 | 100 mm dia |
| 162 | 150 mm dia |
| 163 | 200 mm dia |
| 164 | 250 mm dia |
| 165 | 300 mm dia |
| 166 | Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved byauthority specification and the direction of the Engineer.Apply corrosion, resistant, protection on inside and outside of casing pipeas per technical specification. |
| 167 | 300 mm Dia 8 mm thick casing pipe with protective coating. |
| 168 | Providing, laying and jointing RCC NP4pipe with cement mortar joints by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per the direction of NHAI including carrying out survey work at the job site for determining underground cable trenches like telephone, power cable, water & sanitary lines and resistivity tests for finding the soil strata using necessary equipments for completion of work, mobilizing of machineries and specialized crew at the job site, etc. complete in all respects,including excavation of drive pit and exit pit (upto 3 metre depth) with proper protection at the three sides, providing and casting of MS cutting edges for front shield and constructingthrustbedatdesignedlevelasdirectedbythe Engineer,necessaryde-wateringandprovidingconcrete foundations at the base of the Drive pit, crane for handling of pipes, and any other machinery, tool & tackels required, construction of temporaryworksasperrequirementandasapprovedbyNH authorities complete in all respect for the road crossing at necessary depth (all depths) with all lead and lifts, as per secification and the direction ofthe Engineer |
| 169 | 300 mm dia |
| 170 | 400 mm dia |
| 171 | Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Section of foundation above PCC W-600 mm, D-450mm, W- 450mm, D-450 mm.4. Superstructure work: Stone masonary W-300, height-1650 mm,/ Brick work W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6.6. Expansion joint shall be on every 30 mtr.7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done. |
| 172 | Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamal paints. |
| 173 | Dismantling of cement concrete pavement for pipe lineand chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shallbe made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. |
| 174 | Provision of restoration of cement concrete roads after laying and jointing pipeline as per direction of Engineer In charge |
| 175 | Dismantling of flexible pavement for pipe lineand chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be madefor trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work. |
| 176 | Bituminous courses |
| 177 | Granular courses |
| 178 | Provision for Restroration of Bitumen Road after laying & jointing pipe line as per direction of Engineer In charge |
| 179 | Dismantling of flexible pavement for pipe lineand chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be madefor trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work. |
| 180 | Granular courses |
| 181 | Provision for Restroration of WBM Road after laying & jointing pipe line as per direction of Engineer In charge |
| 182 | Earth work in excavation by mechanical means (Hydraulic Excavator )/manual means in trenches for water supply pipe lines, shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for lifts up to 1.5 depth and strata as specified. The work also includes depositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr. All kinds of soils |
| 183 | 75 mm dia |
| 184 | 90 mm dia |
| 185 | 110 mm dia |
| 186 | 125 mm dia |
| 187 | 140 mm dia |
| 188 | 160 mm dia |
| 189 | 180 mm dia |
| 190 | 200 mm dia |
| 191 | 225 mm dia |
| 192 | Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes PE 100 PN 6.0 as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. |
| 193 | 75 mm dia |
| 194 | 90 mm dia |
| 195 | 110 mm dia |
| 196 | Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply of pipe shall be in straight length in 6/12 M. PE 100 PN 6.0 |
| 197 | 125 mm dia |
| 198 | 140 mm dia |
| 199 | 160 mm dia |
| 200 | 180 mm dia |
| 201 | 200 mm dia |
| 202 | 225 mm dia |
| 203 | Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Manually Operated Resilient Seated Sluice Valves of Class PN 1.0/1.6. For Sluice valves |
| 204 | 80 mm dia |
| 205 | 100 mm dia |
| 206 | 125 mm dia |
| 207 | 150 mm dia |
| 208 | 200 mm dia |
| 209 | Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Manually Operated Resilient Seated Sluice Valves of Class PN 1.0/1.6. For Pressure Reducing Valves |
| 210 | 80 mm dia |
| 211 | 100 mm dia |
| 212 | 125 mm dia |
| 213 | 200 mm dia |
| 214 | Construction of valve chamber as per approved drawing and specifications to the satisfaction of Engineer-in-charge. |
| 215 | for size from 80 mm to 100 mm (Type-A) |
| 216 | for size from 125 mm to 200 mm (Type-B) |
| 217 | Providing, lowering, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning and as per technical specifications and direction of Engineer In-Charge. Class PN 1.0/1.6 |
| 218 | 80 mm dia |
| 219 | 100 mm dia |
| 220 | 125 mm dia |
| 221 | 150 mm dia |
| 222 | 200 mm dia |
| 223 | Dismantling of flexible pavement for pipe line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work. For BT Roads |
| 224 | Bituminous Course |
| 225 | Granular Course |
| 226 | Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. For CC Roads |
| 227 | Dismantling of flexible pavement for pipe line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work. For WBM Roads |
| 228 | Restoration of BT roads |
| 229 | Restoration of WBM roads |
| 230 | Restoration ogf CC roads |
| 231 | Providing service connection as per technical specification and standard drawing as per relevant IS code (amended up to date) from all kind of water mains up to consumer meter/premises (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil including demolishing of cement concrete,WBM, Black top etc. of all thickness; cutting of CC road/jhiri by using a concrete cutter machine; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 50 meter ; providing & fixing of all fitting duly approved in accordance with ISO/DTR 9080 as per specification for potable water including approved make of MS/PVC clamp with saddle piece, gunmetal ferrule 4.0 mm (ISI make) ,valve (IS: 778) and specials with MDPE pipe PE80 PN 12.5 as per ISO 4427 below ground level and GI 15 mm class B (ISI mark) above ground level ( max. length 3.0 mtr), P&F a Bib Cock (IS : 8931 Mark), Superior quality Brass 400 gm,15 mm nominal bore including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . In addition to the ferrule, an orifice of 4.0 mm dia should also be provided in the service line at the entry point of the consumer\"s property in such a way that it should be accessible for inspection to VWSC, PHED and any other authority which would like to inspect as and when required. The service line should be laid at least 45 cm below ground level, except in case of concrete/bituminous roads where minimum depth shall be 20 cm.For detailed specifications of MDPE pipes please refer section \"Technical Specifications\" of bid document. General specifications of MDPE pipes shall be as under:• The raw material shall be virgin PE 80 Blue compound and comply with the requirements of ISO/Directive of testing material : 9080 with minimum required strength of 8 Kg/sq.cm.• The raw material shall be Food grade quality Pressure rating shall be 12.5 Bar.• The pipes shall bear ISO marking. |
| 232 | Add extra over item no 1.21 & 1.22 for providing20 mm PE80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr. |
| 233 | Construction of Pump house of required size suitable for installation ofpumping sets as per approved GA drawing, scope of work and technical specification complete work in all respect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement. |
| 234 | TPS-2 & CPS-1 (KALOO) |
| 235 | TPS-3 & CPS-2 (LADHRIYA) |
| 236 | CPS-3 (ADSAR PUROHITAN) |
| 237 | CPS-4 (MPMASAR) |
| 238 | CPS-5 ( KUNTASAR) |
| 239 | TPS-4 Dungargarh Town For Rural |
| 240 | TPS-4 Dungargarh Town For Urban |
| 241 | TPS-5 & CPS-6 (TOLIYASAR) |
| 242 | TPS-6 & CPS-7 (MANKRASAR) |
| 243 | CPS-8 (JODHASAR) |
| 244 | CPS-9 (PUNDALSAR) |
| 245 | TPS-7 & CPS- 10 (KALYANSAR) |
| 246 | CPS-11 (RIRI) |
| 247 | CPS-12 (KEU) |
| 248 | A : External Lighting |
| 249 | P & F IP-65 protected street light luminaire on existing bracket suitable for HPSV/MH LAMP, made from powder coated single piece pressure die cast aluminium housing electrochemically brightened and anodized POT optics aluminium reflector, heat resistant & toughened glass cover and accessories like copper ballast, electronic ignitor, capacitor, holder prewired up to terminal block etc. as required including making connection testing etc. as required (without lamp) street light suitable for metal halide lamps : 1x150W |
| 250 | Supply and errection of MS swaged tubuler pole as per IS 27131980(part I & II) and made out from tube of ISI mark for structural purpose, with MS base base plate in position, including excavation of pit, filling the same with C.C. of M-10 grade (1:3:6) from bottom to 50 cm above the ground level with the help of steel frame of 40 cm dia upto bottom section of 114.3 mm OD & 50 cm dia beyond 114.3 mm OD, duly finished with cement plaster, GI cable sleev, earthing terminal, cable entry, rubber paint upto CC level, red oxide in remaining portion, duly finished with two coats of Aluminium/enamel paint, approved by engineer incharge. The pole shall be as per following specification (See Table) |
| 251 | 7.5 mtr. (410 SP-5) |
| 252 | Add for Supply & fixing of MS overhang of following size over the existing poles |
| 253 | 76.1 mm OD x 3.25 mm thickness |
| 254 | P & F Normal/ High OutputHigh pressure sodium vapour/ Metal halide/ Halogen lamp as required : |
| 255 | Metal Halide Lamp Double ended 150 Watts |
| 256 | P & F Electronic ignitor suitable for HPSV/ Metal halide lamp up to 30.0 Mtr. distance as required. |
| 257 | P/Laying XLPE insulated /P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 4cx6mm sq aluminium armoured |
| 258 | B : Horticulture |
| 259 | Supply at site of work well decayed farm yard manure from any available source approved by Engineer-in-charge including screening and stacking |
| 260 | Supply&Stackinggoodearthatsitecompleteincludingloading,unloading&transporationetc. |
| 261 | Supply of Insecticides & Pesticides Methyl Prathion 2% at store in dust / liquid form complete. |
| 262 | Grassing with \"Doobs\" grass In rows 15 cm apart in either direction including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed. |
| 263 | Supply and planting of Tabernaemontana variegated ( Chandni) in poly bags / earthen pots well branched, well established & free from disease of 900 mm min. height plants at site in 0.60 m dia holes,1 m deep dug in the ground,mixing the soil with decayed farm yard/sludge manure,backfilling the hole watering etc as required. |
| 264 | Supply and planting of Wedelia trilobata ( SunFlower Family) in poly bags / earthen pots well branched, well established & free from disease of 300 mm min. height ground covers at site in 0.3 m dia holes,0.3 m deep dug in the ground,mixing the soil with decayed farm yard/sludge manure,backfilling the hole watering etc as required. |
| 265 | Supply and planting of Boungainvilleabest quality container grown healthy trees of 2 mt. min. height, well established & free from disease at site in 0.90 m dia holes,1 m deep dug in the ground,mixing the soil with decayed farm yard/sludge manure,backfilling the hole watering etc as required. |
| 266 | General Leveling & grading of the campus area and provision for rainwater harvesting structures |
| 267 | C : Construction of Cement Concrete Road |
| 268 | Earth work in excavation for roadway, including trimming bottom and side slopes in accordance with requirement of line, grades and cross sections, including disposal of surplus material with all lift and lead upto 1000 metre |
| 269 | In all types of soil [MoRTH Specification : Clause : 301] |
| 270 | Providing, laying and compacting plain/ reinforced cement concrete of specified grade in foundation/ leveling course/ pile cap using concrete mixer and vibrater complete including cost of form work, as per drawing and technical specifications and as per clause 1100, 1500,1700,2100 of MoRT&H specification including all scaffolding material, labour, machinery. |
| 271 | P.C.C.M-15 grade |
| 272 | Total |
| 273 | P.C.C.M-20 grade |
| 274 | Total |
| 275 | D : Construction of Surface Drainge ( Masonary) |
| 276 | Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottom, lift upto 1.5 Mtr. including taking out the excavated soil and depositing and refilling of jhiri with watering and ramming and disposal ofsurplus excavated soil as directed within a lead of 50 m in all kinds of soil. |
| 277 | Basefloor |
| 278 | Providing and laying in position cement concrete including curing compaction etc. of specified grade excluding the cost of centering and shuttering. All up to plinth level |
| 279 | Base Floor |
| 280 | RR stone masonary suerstructure ( cm 1:4) |
| 281 | Vertical InnerLongWall |
| 282 | Cement Plaster 1:4 cm (20 mm) |
| 283 | Cement Concrete Coping M15 |
| 284 | Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Section of foundation above PCC W-600 mm, D-450mm, W- 450mm, D-450 mm.4. Superstructure work: Stone masonary W-300, height-1650 mm,/ Brick work W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6.6. Expansion joint shall be on every 30 mtr.7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done. |
| 285 | Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamal paints. |
| 286 | Construction of Chokidar Hut/J2 Quater of required size as per approved GA drawing, scope of work and technical specification complete work in all respect including electrical works for lighting and fans, rain water drainage. (1set of J2 type quarter = 100 Sqm) |
| 287 | TPS-2 & CPS-1 (KALOO) |
| 288 | TPS-3 & CPS-2 (LADHRIYA) |
| 289 | CPS-3 (ADSAR PUROHITAN) |
| 290 | CPS-4 (MPMASAR) |
| 291 | CPS-5 ( KUNTASAR) |
| 292 | TPS-5 & CPS-6 (TOLIYASAR) |
| 293 | TPS-6 & CPS-7 (MANKRASAR) |
| 294 | CPS-8 (JODHASAR) |
| 295 | CPS-9 (PUNDALSAR) |
| 296 | TPS-7 & CPS- 10 (KALYANSAR) |
| 297 | CPS-11 (RIRI) |
| 298 | CPS-12 (KEU) |
| 299 | Fabrication, supply of flanged/ plain ended MS pipe made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete excluding flanged jointing wherever (required) including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. |
| 300 | MS pipe upto 600 mm dia (with minimum 5mm thickness sheet |
| 301 | MS pipe above 600mm dia (with minimum 6.3mm thickness sheet) |
| 302 | Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Motorised sluice Valves with Electric Actuator and integral starterof Class PN 1.6 |
| 303 | 80 mm dia |
| 304 | 100 mm dia |
| 305 | 125 mm dia |
| 306 | 150 mm dia |
| 307 | 200 mm dia |
| 308 | 250 mm dia |
| 309 | 300 mm dia |
| 310 | 350 mm dia |
| 311 | 400 mm dia |
| 312 | 450 mm dia |
| 313 | 500 mm dia |
| 314 | 600 mm dia |
| 315 | Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice valves of approved make & design standard of following dia complete (including jointing & jointing material ) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer.(Electrically Operated & SCADA Compatible class PN 1.6) |
| 316 | 700mm dia |
| 317 | Providing, installation, testing and commissioning of following Stain less steel AISI 304 Expansion bellows of 16 bar rating with tie rods as per technical specifications and layout drawings including jointing material like nuts, bolts, rubber gaskets etc. complete in all respect as per technical specification and direction of Engineer In-Charge. |
| 318 | 80 mm dia |
| 319 | 100 mm dia |
| 320 | 125 mm dia |
| 321 | 150 mm dia |
| 322 | 200 mm dia |
| 323 | 250 mm dia |
| 324 | 300 mm dia |
| 325 | 350 mm dia |
| 326 | 400 mm dia |
| 327 | 450 mm dia |
| 328 | 600 mm dia |
| 329 | 700 mm dia |
| 330 | Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer. PN 1.6 |
| 331 | 400 mm dia |
| 332 | 500 mm dia |
| 333 | Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amendedup to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/316 & shaft bearings-bronze/ PTET or Teflon with EPDM/NBR \"O\" ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Class PN 1.6, Motorised operated/Wafer TypeNote: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 334 | 80 mm dia |
| 335 | 100 mm dia |
| 336 | 125 mm dia |
| 337 | 150 mm dia |
| 338 | 200 mm dia |
| 339 | 250 mm dia |
| 340 | 400 mm dia |
| 341 | Providing, lowering, aligning, fixing in position in pipe line, DIdouble flanged resilient seated Dual plate check valve of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M, Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside .Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/410 , Hinge SS AISI 316/304,SpringSS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \"O\" ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) ,Insersion rubber of black EPDM 6mm thick .Suitablesupport structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. PN 1.6Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 342 | 80 mm dia |
| 343 | 100 mm dia |
| 344 | 125 mm dia |
| 345 | 150 mm dia |
| 346 | 200 mm dia |
| 347 | 250 mm dia |
| 348 | 400 mm dia |
| 349 | Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casting pumps/Centrifugal Monoblock Pump sets with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specification |
| 350 | Discharge 63.1783625730994 lps Head 51 m |
| 351 | Discharge 203.220295055821 lps Head 68 m |
| 352 | Discharge 19.265168128655 lps Head 37 m |
| 353 | Discharge 23.5804093567251 lps Head 79 m |
| 354 | Discharge 12.4014985380117 lps Head 65 m |
| 355 | Discharge 11.499817251462 lps Head 74 m |
| 356 | Discharge 40.6057947900053 lps Head 70.5 m |
| 357 | Discharge 176.005715045189 lps Head 69 m |
| 358 | Discharge 9.33022660818713 lps Head 38 m |
| 359 | Discharge 9.67690058479532 lps Head 64 m |
| 360 | Discharge 69.61 lps Head 70 m |
| 361 | Discharge 35.7296650717703 lps Head 70 m |
| 362 | Discharge 5.97277046783626 lps Head 75 m |
| 363 | Discharge 16.3731725146199 lps Head 48 m |
| 364 | Discharge 45.0773220833265 lps Head 47 m |
| 365 | Discharge 6.0625 lps Head 44 m |
| 366 | Discharge 15.5575657894737 lps Head 55 m |
| 367 | Discharge 7.92598684210526 lps Head 45 m |
| 368 | Discharge 15.5180921052632 lps Head 66 m |
| 369 | Discharge 12.1754385964912 lps Head 56.5 m |
| 370 | Discharge 29.6306652046784 lps Head 76 m |
| 371 | Discharge 32.5131578947368 lps Head 52 m |
| 372 | Discharge 39.1904572036151 lps Head 55 m |
| 373 | Discharge 14.483735380117 lps Head 38 m |
| 374 | Discharge 22.0168128654971 lps Head 65 m |
| 375 | Discharge 24.0570175438596 lps Head 73 m |
| 376 | Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 operating at sync. speed 2900 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected onC.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions of one of the makes approved by Technical Committee. |
| 377 | Discharge 13.0895467836257 lps Head 75 m |
| 378 | Discharge 8.06743421052632 lps Head 47 m |
| 379 | Discharge 9.81176900584795 lps Head 54 m |
| 380 | Discharge 16.8706140350877 lps Head 29 m |
| 381 | Discharge 7.99360380116959 lps Head 55 m |
| 382 | Discharge 16.8167032163743 lps Head 44.5 m |
| 383 | Discharge 16.546418128655 lps Head 66 m |
| 384 | Discharge 24.4431652046784 lps Head 50 m |
| 385 | Discharge 20.2624269005848 lps Head 57 m |
| 386 | Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casting pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specification |
| 387 | Discharge 15.468932748538 lps Head 45.5 m |
| 388 | Discharge 14.9296418128655 lps Head 44 m |
| 389 | Discharge 18.7297149122807 lps Head 51.5 m |
| 390 | Discharge 25.0301535087719 lps Head 43 m |
| 391 | Discharge 28.8567251461988 lps Head 67 m |
| 392 | Supplying, erecting, testing & commissioning of Electrically Operated Travelling Crane (EOT) .Main girder & End Carriage fabricated from Rollled Steel Section, Gear Box for all motion, Electro Magnetic Friction Disc Type Brakes, all safety limit switches, LT wheels EN 9, Double Flanged 4No, with Sq. Cage motor of adequate rating (KW), duly painted mechanical cleaning and one coat of primer and two coat of synthetic paint and as per the direction of the Engineer.2 MT Capacity |
| 393 | Span 8.5 M and Lift 7.8 M 2MT |
| 394 | Span 5.5 M and Lift 7.8 M 2MT |
| 395 | Span 8.5 M and Lift 7.8 M 3MT |
| 396 | Span 5.5 M and Lift 7.8 M 3MT |
| 397 | Span 4.5 M and Lift 6.5 M 2MT |
| 398 | Span 4.5 M and Lift 6.5 M 2MT |
| 399 | Span 4.0 M and Lift 9.0 M 2MT |
| 400 | Span 8.5 M and Lift 7.8 M 3MT |
| 401 | Span 6.5 M and Lift 6.5 M 2MT |
| 402 | Span 6.5 M and Lift 6.5 M 3MT |
| 403 | Span 4.5 M and Lift 6.5 M 2 MT |
| 404 | Span 4.5 M and Lift 6.5 M 2MT |
| 405 | Span 6.5 M and Lift 6.5 M 2MT |
| 406 | Span 6.5 M and Lift 6.5 M 2MT |
| 407 | Span 4.5 M and Lift 6.5 M 2MT |
| 408 | Design, Manufacturing and Supply of Batch Type Electro chlorinator of capacity gm/Hr |
| 409 | 500 KLH |
| 410 | 200 KLH |
| 411 | 300 KLH |
| 412 | Providing,installation, testing and commisioning of vacuum Feed Gas Chlorinator with all assessories and making connection with existing pipeline required including supply & instalation of trunnionroller support, auxillary container valve,fluxible copper connector, manifold valve, tonner manifold pipes, chlorine Pressure gauge, Isolation valve, gas filter, pressure reducing valve, chlorine gas pipe with fittings, diffuser, lifting beam, load indicator, 25 NB PP diaphragm Valve on injector inlet & outlet, 32 OD uPVC pipe for chlorine solution, 25 NB GI pipe for pump suction & delivery, 25 NB GM gate valve on pump suction & delivery, 25 NB GM \"Y\" type stainer on pump suction, 25 NB GM Check valve on pump delivery, pressure gauge with Isolated valve on pump delivery and chlorine booster pump with motor of required capacity complete in all respect as per specification and the direction of the Engineer. 2 kg/hr capacity |
| 413 | Supply of Chlorine Tonner as per specifications with rollers completein all respect as per the direction of Engineer. (Rural) |
| 414 | SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) ,Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304,Electrode : SS AISI 316L /Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection with existing pipeline including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. |
| 415 | EFM 80 mm |
| 416 | EFM100 mm |
| 417 | EFM 125 mm |
| 418 | EFM 150 mm |
| 419 | EFM 200 mm |
| 420 | EFM 250 mm |
| 421 | EFM 300 mm |
| 422 | EFM 600 mm |
| 423 | Providing, installation, testing and commissioning of glycerin filled Pressure gauge of following ranges with isolation valve and tap off pipe complete in all respect as per technical specification and as per direction of Engineer. |
| 424 | 0 to 4.0 / 0 to 6.0 / 0 to 10.0 kg/cm² |
| 425 | Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA with HART / Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 1/2 M (NPT) |
| 426 | Supply, Installation, Testing & Commissioning of HT metering cubical panel as approved By DISCOMs fabricated out of 14 SWGCRCA sheet steel in two compartment & MS angle of size60mmX6mm having provision for Following:(i) Provision for fixing Trivector Meter (To be supplied by DISCOMs)(ii) Provision for fixing of combined CT PT Set (To be supplied byDISCOMs)(iii)TT Block(iv) 6mm Bakelite sheet on all sides. |
| 427 | Supply, Installation, testing and commissioning of 11 KV DoublePole structure With Air Break SWITCH having followingspecifications :(a) DP : Double pole structure made of two nos. 9 meter long PCCpoles (400 Kg) & 7 nos. MS Channel each of size 100 mmx50mmx2500mm complete with earthing of the structure as perREC standards in all respect with nuts, springs washers, clamps asrequired.(b) GO:Off load type gang operated 3-pole vertical flute type switchsuitable for 11KV ; 400A ,3 phase, central post rotating double breakisolator complete with MS hardware , copper moving & fixed contact,assembly of 9 Nos pin insulator ,GI pipe of suitable length foroperation.c) DO: 3 Nos. Horizontal/Vertical mounted 33KV Horn Gap fuse set /Drop Out fuse set, 33KV barrel fuses mounted on 6 Nos. Postinsulators.(c) DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set/drop out 11kv barrel fuses mounted on 6no pin insulators(d) LA:3 piece non linear resistor type. lighting arrestor of approvedmake suitable for 3 wire, 11kv oh linewith rated voltage of 9kv rms &nominal discharge current rating of 5 ka & complete with galvanizedclamping arrangement GI bolts, nuts, washer etc as required.(e) JUMPERS: 3 no 11kv acsr conductors mounted on pin typeinsularors as required.GENERAL:The go shall be operated by hand operated liver properlyearthed with provision for locking mounted at 3’ |
| 428 | Supply, Installation, Testing and commissioning of copper wound ISImarked Transformer 11/0.433 KV, Three Phase, 50 Hz, DYN 11,ONAN type , Standard accessories like, conservator, Silicagelbreather, radiator, fins, HT & LT cable end boxes or Bus Duct flange,Lifting lugs, Bi-directional Plain/ Flanged Rollers,Earthingterminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof 2.5%), winding / Top oil temperature rise of 45°C/40°C, ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxybased paint etc having max. total losses as per energy efficiencylevel - 2 at basic Insulation level conforming to IS 2026 (Part- I toPart - II), latest ammended and IS 1180 Part-I : 2014 BEE star level- I as per Govt. of India, Ministry of power notification Dated 16thDec., 2016. Transformers described as above and as per thefollowing continuous rating |
| 429 | 1000 KVA |
| 430 | Providing & Laying XLPE insulated IS:7098/II/85 ofapproved make H.T.cable for working voltage 11K.V.Earthed with Stranded Compacted CircularAluminium Conductor, Conductor Screened withExtruded Semi-conducting compound, XLPE Insulated,Insulation Screened with extruded semi-conductingcompound in combination with Copper Tape, cores laidup, inner sheath of Thermoplastic tape, galvanised flatsteel strip armoured and overall Extruded PVC Type ST-2 Outer Sheathed cable direct in ground includingexcavation of 30cmx100cm size trench, 25cm layer ofriver sand, second Class bricks covering, refilling earth,compaction of earth, making necessary connectiontesting etc.as required of size. |
| 431 | 3 core 185.0 Sq.mm |
| 432 | Providing & making heat shrinkable type indoor/outdoor/straightthrough terminations/joint kit of approved make suitable for XLPEinsulated 11 KV cable, with required components, prepration ofcable ends,testing etc. as required of following sizes . |
| 433 | 3 core 120/150/185 Sq.mm |
| 434 | 3 core 120/150/185/225 Sq.mm |
| 435 | P/Laying XLPE insulated / P.V.C. sheathed cable of 1.1KV grade with aluminium conductor Armoured ofIS:7098-I/1554-1 approved make in ground as perIS:1255 including excavation of 30cmx75cm size trench,25 cm thick under layer of sand,IInd class brickscovering, refilling earth,compaction of earth, makingnecessary connection, testing etc. as required of size. |
| 436 | 3/CX4 sq mm |
| 437 | 4/CX10 sq mm |
| 438 | 3/CX70 sq mm |
| 439 | 3/CX10 sq mm |
| 440 | 3/CX25 sq mm |
| 441 | Providing & Laying XLPE/PVC PVC insulated & PVC Sheathed armoured control Cable of 1.1 KV grade with copper conductor as per IS 1275 including escavation of 30cmX 75 cm size trench 25 cm thick under layer of sand and lind class of bricks covering |
| 442 | 14CX1.5 sq mm |
| 443 | 5CX1.5 sq mm |
| 444 | Supplying and making one end termination with heavy duty doublecompression brass gland SIBG type, aluminium lugs duly crimpedwith crimping tool, PVC tape etc for following size of Armoured PVCinsulated & PVC sheathed/ XLPE aluminium conductor cable of1100 volt grade as required of size. |
| 445 | 4/C 10 sq mm |
| 446 | 3/CX4 sq mm |
| 447 | 3/CX70 sq mm |
| 448 | 3/CX10 sq mm |
| 449 | 3/CX25 sq mm |
| 450 | Supply, Fabricating & installing following sizes of perforated cabletrays including horizontal and vertical bends, reducers tees,crossmembers and other accessories as required and duly suspendedfrom the ceiling with suspenders and including painting as required. |
| 451 | 600mm x 50mm x 2.0mm |
| 452 | 150mm x 50mm x 1.6mm |
| 453 | Supply,installation,testing and commissionionig of floor mounted LV Switchboard (indoor dury,dust proof,vermin proof IP-4Xfront operated with 2 mm thick sheet metal compartmentalised) with all accessible parts,heat shrinkable sleeves,SMC/DMC bus bar supports, padlocking facility complete in all respect in line with SLD. |
| 454 | Supply Installation Testing & commissioning of Local Push button Station |
| 455 | SITC of microprocessor based intelligent power factor correctionrelay having sensitivity up to 50 milli Amp secondary current andfollowing way, self analysing auto c/k setting according to targetedpower factor setting, the relay shall have minimum three digit displayunit for display of real power factor, targeted power factor, lag/leadcapacitor switching status, alarm output for under current, overcurrent, insufficient compensation, indication of switching on units,auto/manual status, and shall have over load protection, no voltrelease etc. as required. |
| 456 | 6 to 14 stage - sensitivity upto 50 milli Amp. |
| 457 | SITC of self healing MPP/MP type shunt capacitor (banks)conforming to IS:13340-41 / IEC :831-1&2 in existing panel orparallel with load terminals , the capacitor shall be fitted withdischarge resistors, pressure sensitive disconnector ( PSD ) andshall have dissipation factor less than 0.0025 at 50 Hz and totalwattage loss less than 0.5 Watt per KVAR. including makingconnections with suitable capacity conductors/cables testing asrequired. |
| 458 | Heavy duty Three phase 440 V , 50 Hz capacitor (Bank) |
| 459 | Plate Earthing as per IS:3043 with copper Earth plate of size600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below theground level with 20 mm dia. G.I. \"B\" class watering Pipe including allaccessories like nut, bolts, reducer, nipple ,wire meshed funnel, andC.C. finished chamber covered with hinged type with lockingarrangement C.I. Cover, C.I. Frame of size300mm x 300mmcomplete with alternate layers of salt and coke/charcoal, testing ofearth resistance as required. |
| 460 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. of following size. |
| 461 | 50mm x 6mm G. I. strip |
| 462 | 25mm x 3mm Alum. Strip |
| 463 | S.I.T.C. of bus trunking arrangement in convenient sectionscomplete with housing of galvanized sheet steel of minimum 1.5 mmthickness, aluminium bus bar for use on 3 phase, 4 wire, 415 volts,A.C. supply with degree of protection IP-42 for the following currentcarrying capacity, including jointing of sections, flexible joints.expansion joints, bends, and earthing with 2 runs of alum. strips etc.as required. |
| 464 | 1400 amps |
| 465 | Miscellaneous items Rubber mat,Danger Plate,Lugs,steel etc |
| 466 | Supply, Installation, Testing & Commissioning of HT meteringcubical panel as approved By DISCOMs fabricated out of 14 SWGCRCA sheet steel in two compartment & MS angle of size60mmX6mm having provision for Following:(i) Provision for fixing Trivector Meter (To be supplied by DISCOMs)(ii) Provision for fixing of combined CT PT Set (To be supplied byDISCOMs)(iii)TT Block(iv) 6mm Bakelite sheet on all sides. |
| 467 | Supply, Installation, testing and commissioning of 11 KV DoublePole structure With Air Break SWITCH having followingspecifications :(a) DP : Double pole structure made of two nos. 9 meter long PCCpoles (400 Kg) & 7 nos. MS Channel each of size 100mmx50mmx2500mm complete with earthing of the structure as perREC standards in all respect with nuts, springs washers, clamps asrequired.(b) GO:Off load type gang operated 3-pole vertical flute type switchsuitable for 11KV ; 400A ,3 phase, central post rotating double breakisolator complete with MS hardware , copper moving & fixed contact,assembly of 9 Nos pin insulator ,GI pipe of suitable length foroperation.c) DO: 3 Nos. Horizontal/Vertical mounted 33KV Horn Gap fuse set /Drop Out fuse set, 33KV barrel fuses mounted on 6 Nos. Postinsulators.(c) DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set/drop out 11kv barrel fuses mounted on 6no pin insulators(d) LA:3 piece non linear resistor type. lighting arrestor of approvedmake suitable for 3 wire, 11kv oh linewith rated voltage of 9kv rms &nominal discharge current rating of 5 ka & complete with galvanizedclamping arrangement GI bolts, nuts, washer etc as required.(e) JUMPERS: 3 no 11kv acsr conductors mounted on pin typeinsularors as required.GENERAL:The go shall be operated by hand operated liver properlyearthed with provision for locking mounted at 3’ |
| 468 | Supply, Installation, Testing and commissioning of copper wound ISImarked Transformer 11/0.433 KV, Three Phase, 50 Hz, DYN 11,ONAN type , Standard accessories like, conservator, Silicagelbreather, radiator, fins, HT & LT cable end boxes or Bus Duct flange,Lifting lugs, Bi-directional Plain/ Flanged Rollers,Earthingterminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof 2.5%), winding / Top oil temperature rise of 45°C/40°C, ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxybased paint etc having max. total losses as per energy efficiencylevel - 2 at basic Insulation level conforming to IS 2026 (Part- I toPart - II), latest ammended and IS 1180 Part-I : 2014 BEE star level- I as per Govt. of India, Ministry of power notification Dated 16thDec., 2016. Transformers described as above and as per thefollowing continuous rating |
| 469 | 1000 KVA |
| 470 | Providing & Laying XLPE insulated IS:7098/II/85 ofapproved make H.T.cable for working voltage 11K.V.Earthed with Stranded Compacted CircularAluminium Conductor, Conductor Screened withExtruded Semi-conducting compound, XLPE Insulated,Insulation Screened with extruded semi-conductingcompound in combination with Copper Tape, cores laidup, inner sheath of Thermoplastic tape, galvanised flatsteel strip armoured and overall Extruded PVC Type ST-2 Outer Sheathed cable direct in ground includingexcavation of 30cmx100cm size trench, 25cm layer ofriver sand, second Class bricks covering, refilling earth,compaction of earth, making necessary connectiontesting etc.as required of size. |
| 471 | 3 core 185.0 Sq.mm |
| 472 | Providing & making heat shrinkable type indoor/outdoor/straightthrough terminations/joint kit of approved make suitable for XLPEinsulated 11 KV cable, with required components, prepration ofcable ends,testing etc. as required of following sizes . |
| 473 | 3 core 120/150/185 Sq.mm |
| 474 | 3 core 120/150/185/225 Sq.mm |
| 475 | P/Laying XLPE insulated / P.V.C. sheathed cable of 1.1KV grade with aluminium conductor Armoured ofIS:7098-I/1554-1 approved make in ground as perIS:1255 including excavation of 30cmx75cm size trench,25 cm thick under layer of sand,IInd class brickscovering, refilling earth,compaction of earth, makingnecessary connection, testing etc. as required of size. |
| 476 | 3/CX4 sq mm |
| 477 | 4/CX10 sq mm |
| 478 | 3/CX70 sq mm |
| 479 | 3/CX10 sq mm |
| 480 | 3/CX50 sq mm |
| 481 | Providing & Laying XLPE/PVC PVC insulated & PVC Sheathed armoured control Cable of 1.1 KV grade with copper conductor as per IS 1275 including escavation of 30cmX 75 cm size trench 25 cm thick under layer of sand and lind class of bricks covering |
| 482 | 14CX1.5 sq mm |
| 483 | 5CX1.5 sq mm |
| 484 | Supplying and making one end termination with heavy duty doublecompression brass gland SIBG type, aluminium lugs duly crimpedwith crimping tool, PVC tape etc for following size of Armoured PVCinsulated & PVC sheathed/ XLPE aluminium conductor cable of1100 volt grade as required of size. |
| 485 | 4/C 10 sq mm |
| 486 | 3/CX4 sq mm |
| 487 | 3/CX70 sq mm |
| 488 | 3/CX10 sq mm |
| 489 | 3/CX50 sq mm |
| 490 | Supply, Fabricating & installing following sizes of perforated cabletrays including horizontal and vertical bends, reducers tees,crossmembers and other accessories as required and duly suspendedfrom the ceiling with suspenders and including painting as required. |
| 491 | 600mm x 50mm x 2.0mm |
| 492 | 150mm x 50mm x 1.6mm |
| 493 | Supply,installation,testing and commissionionig of floor mounted LV Switchboard (indoor dury,dust proof,vermin proof IP-4Xfront operated with 2 mm thick sheet metal compartmentalised) with all accessible parts,heat shrinkable sleeves,SMC/DMC bus bar supports, padlocking facility complete in all respect in line with SLD. |
| 494 | Supply Installation Testing & commissioning of Local Push button Station |
| 495 | SITC of microprocessor based intelligent power factor correctionrelay having sensitivity up to 50 milli Amp secondary current andfollowing way, self analysing auto c/k setting according to targetedpower factor setting, the relay shall have minimum three digit displayunit for display of real power factor, targeted power factor, lag/leadcapacitor switching status, alarm output for under current, overcurrent, insufficient compensation, indication of switching on units,auto/manual status, and shall have over load protection, no voltrelease etc. as required. |
| 496 | 6 to 14 stage - sensitivity upto 50 milli Amp. |
| 497 | SITC of self healing MPP/MP type shunt capacitor (banks)conforming to IS:13340-41 / IEC :831-1&2 in existing panel orparallel with load terminals , the capacitor shall be fitted withdischarge resistors, pressure sensitive disconnector ( PSD ) andshall have dissipation factor less than 0.0025 at 50 Hz and totalwattage loss less than 0.5 Watt per KVAR. including makingconnections with suitable capacity conductors/cables testing asrequired. |
| 498 | Heavy duty Three phase 440 V , 50 Hz capacitor (Bank) |
| 499 | Plate Earthing as per IS:3043 with copper Earth plate of size600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below theground level with 20 mm dia. G.I. \"B\" class watering Pipe including allaccessories like nut, bolts, reducer, nipple ,wire meshed funnel, andC.C. finished chamber covered with hinged type with lockingarrangement C.I. Cover, C.I. Frame of size300mm x 300mmcomplete with alternate layers of salt and coke/charcoal, testing ofearth resistance as required. |
| 500 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. of following size. |
| 501 | 50mm x 6mm G. I. strip |
| 502 | 25mm x 3mm Alum. Strip |
| 503 | S.I.T.C. of bus trunking arrangement in convenient sectionscomplete with housing of galvanized sheet steel of minimum 1.5 mmthickness, aluminium bus bar for use on 3 phase, 4 wire, 415 volts,A.C. supply with degree of protection IP-42 for the following currentcarrying capacity, including jointing of sections, flexible joints.expansion joints, bends, and earthing with 2 runs of alum. strips etc.as required. |
| 504 | 1400 amps |
| 505 | Miscellaneous items Rubber mat,Danger Plate,Lugs,steel etc |
| 506 | Supply, Installation, Testing & Commissioning of HT meteringcubical panel as approved By DISCOMs fabricated out of 14 SWGCRCA sheet steel in two compartment & MS angle of size60mmX6mm having provision for Following:(i) Provision for fixing Trivector Meter (To be supplied by DISCOMs)(ii) Provision for fixing of combined CT PT Set (To be supplied byDISCOMs)(iii)TT Block(iv) 6mm Bakelite sheet on all sides. |
| 507 | Supply, Installation, testing and commissioning of 11 KV DoublePole structure With Air Break SWITCH having followingspecifications :(a) DP : Double pole structure made of two nos. 9 meter long PCCpoles (400 Kg) & 7 nos. MS Channel each of size 100mmx50mmx2500mm complete with earthing of the structure as perREC standards in all respect with nuts, springs washers, clamps asrequired.(b) GO:Off load type gang operated 3-pole vertical flute type switchsuitable for 11KV ; 400A ,3 phase, central post rotating double breakisolator complete with MS hardware , copper moving & fixed contact,assembly of 9 Nos pin insulator ,GI pipe of suitable length foroperation.c) DO: 3 Nos. Horizontal/Vertical mounted 33KV Horn Gap fuse set /Drop Out fuse set, 33KV barrel fuses mounted on 6 Nos. Postinsulators.(c) DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set/drop out 11kv barrel fuses mounted on 6no pin insulators(d) LA:3 piece non linear resistor type. lighting arrestor of approvedmake suitable for 3 wire, 11kv oh linewith rated voltage of 9kv rms &nominal discharge current rating of 5 ka & complete with galvanizedclamping arrangement GI bolts, nuts, washer etc as required.(e) JUMPERS: 3 no 11kv acsr conductors mounted on pin typeinsularors as required.GENERAL:The go shall be operated by hand operated liver properlyearthed with provision for locking mounted at 3’ |
| 508 | Supply, Installation, Testing and commissioning of copper wound ISImarked Transformer 11/0.433 KV, Three Phase, 50 Hz, DYN 11,ONAN type , Standard accessories like, conservator, Silicagelbreather, radiator, fins, HT & LT cable end boxes or Bus Duct flange,Lifting lugs, Bi-directional Plain/ Flanged Rollers,Earthingterminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof 2.5%), winding / Top oil temperature rise of 45°C/40°C, ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxybased paint etc having max. total losses as per energy efficiencylevel - 2 at basic Insulation level conforming to IS 2026 (Part- I toPart - II), latest ammended and IS 1180 Part-I : 2014 BEE star level- I as per Govt. of India, Ministry of power notification Dated 16thDec., 2016. Transformers described as above and as per thefollowing continuous rating |
| 509 | 100 KVA |
| 510 | Providing & Laying XLPE insulated IS:7098/II/85 ofapproved make H.T.cable for working voltage 11K.V.Earthed with Stranded Compacted CircularAluminium Conductor, Conductor Screened withExtruded Semi-conducting compound, XLPE Insulated,Insulation Screened with extruded semi-conductingcompound in combination with Copper Tape, cores laidup, inner sheath of Thermoplastic tape, galvanised flatsteel strip armoured and overall Extruded PVC Type ST-2 Outer Sheathed cable direct in ground includingexcavation of 30cmx100cm size trench, 25cm layer ofriver sand, second Class bricks covering, refilling earth,compaction of earth, making necessary connectiontesting etc.as required of size. |
| 511 | 3 core 185.0 Sq.mm |
| 512 | Providing & making heat shrinkable type indoor/outdoor/straightthrough terminations/joint kit of approved make suitable for XLPEinsulated 11 KV cable, with required components, prepration ofcable ends,testing etc. as required of following sizes . |
| 513 | 3 core 120/150/185 Sq.mm |
| 514 | 3 core 120/150/185/225 Sq.mm |
| 515 | P/Laying XLPE insulated / P.V.C. sheathed cable of 1.1KV grade with aluminium conductor Armoured ofIS:7098-I/1554-1 approved make in ground as perIS:1255 including excavation of 30cmx75cm size trench,25 cm thick under layer of sand,IInd class brickscovering, refilling earth,compaction of earth, makingnecessary connection, testing etc. as required of size. |
| 516 | 3/CX4 sq mm |
| 517 | 4/CX10 sq mm |
| 518 | 3.5/CX95 sq mm |
| 519 | 3/CX10 sq mm |
| 520 | Providing & Laying XLPE/PVC PVC insulated & PVC Sheathed armoured control Cable of 1.1 KV grade with copper conductor as per IS 1275 including escavation of 30cmX 75 cm size trench 25 cm thick under layer of sand and lind class of bricks covering |
| 521 | 14CX1.5 sq mm |
| 522 | 5CX1.5 sq mm |
| 523 | Supplying and making one end termination with heavy duty doublecompression brass gland SIBG type, aluminium lugs duly crimpedwith crimping tool, PVC tape etc for following size of Armoured PVCinsulated & PVC sheathed/ XLPE aluminium conductor cable of1100 volt grade as required of size. |
| 524 | 3/CX10 sq mm |
| 525 | 3.5/CX95 sq mm |
| 526 | 4/C 10 sq mm |
| 527 | 3/CX4 sq mm |
| 528 | Supply, Fabricating & installing following sizes of perforated cabletrays including horizontal and vertical bends, reducers tees,crossmembers and other accessories as required and duly suspendedfrom the ceiling with suspenders and including painting as required. |
| 529 | 600mm x 50mm x 2.0mm |
| 530 | 150mm x 50mm x 1.6mm |
| 531 | Supply,installation,testing and commissionionig of floor mounted LV Switchboard (indoor dury,dust proof,vermin proof IP-4Xfront operated with 2 mm thick sheet metal compartmentalised) with all accessible parts,heat shrinkable sleeves,SMC/DMC bus bar supports, padlocking facility complete in all respect in line with SLD. |
| 532 | Supply Installation Testing & commissioning of Local Push button Station |
| 533 | SITC of microprocessor based intelligent power factor correctionrelay having sensitivity up to 50 milli Amp secondary current andfollowing way, self analysing auto c/k setting according to targetedpower factor setting, the relay shall have minimum three digit displayunit for display of real power factor, targeted power factor, lag/leadcapacitor switching status, alarm output for under current, overcurrent, insufficient compensation, indication of switching on units,auto/manual status, and shall have over load protection, no voltrelease etc. as required. |
| 534 | 6 to 14 stage - sensitivity upto 50 milli Amp. |
| 535 | SITC of self healing MPP/MP type shunt capacitor (banks)conforming to IS:13340-41 / IEC :831-1&2 in existing panel orparallel with load terminals , the capacitor shall be fitted withdischarge resistors, pressure sensitive disconnector ( PSD ) andshall have dissipation factor less than 0.0025 at 50 Hz and totalwattage loss less than 0.5 Watt per KVAR. including makingconnections with suitable capacity conductors/cables testing asrequired. |
| 536 | Heavy duty Three phase 440 V , 50 Hz capacitor (Bank) |
| 537 | Plate Earthing as per IS:3043 with copper Earth plate of size600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below theground level with 20 mm dia. G.I. \"B\" class watering Pipe including allaccessories like nut, bolts, reducer, nipple ,wire meshed funnel, andC.C. finished chamber covered with hinged type with lockingarrangement C.I. Cover, C.I. Frame of size300mm x 300mmcomplete with alternate layers of salt and coke/charcoal, testing ofearth resistance as required. |
| 538 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. of following size. |
| 539 | 50mm x 6mm G. I. strip |
| 540 | 25mm x 3mm Alum. Strip |
| 541 | Miscellaneous items Rubber mat,Danger Plate,Lugs,steel etc |
| 542 | Supply, Installation, Testing & Commissioning of HT meteringcubical panel as approved By DISCOMs fabricated out of 14 SWGCRCA sheet steel in two compartment & MS angle of size60mmX6mm having provision for Following:(i) Provision for fixing Trivector Meter (To be supplied by DISCOMs)(ii) Provision for fixing of combined CT PT Set (To be supplied byDISCOMs)(iii)TT Block(iv) 6mm Bakelite sheet on all sides. |
| 543 | Supply, Installation, testing and commissioning of 11 KV DoublePole structure With Air Break SWITCH having followingspecifications :(a) DP : Double pole structure made of two nos. 9 meter long PCCpoles (400 Kg) & 7 nos. MS Channel each of size 100mmx50mmx2500mm complete with earthing of the structure as perREC standards in all respect with nuts, springs washers, clamps asrequired.(b) GO:Off load type gang operated 3-pole vertical flute type switchsuitable for 11KV ; 400A ,3 phase, central post rotating double breakisolator complete with MS hardware , copper moving & fixed contact,assembly of 9 Nos pin insulator ,GI pipe of suitable length foroperation.c) DO: 3 Nos. Horizontal/Vertical mounted 33KV Horn Gap fuse set /Drop Out fuse set, 33KV barrel fuses mounted on 6 Nos. Postinsulators.(c) DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set/drop out 11kv barrel fuses mounted on 6no pin insulators(d) LA:3 piece non linear resistor type. lighting arrestor of approvedmake suitable for 3 wire, 11kv oh linewith rated voltage of 9kv rms &nominal discharge current rating of 5 ka & complete with galvanizedclamping arrangement GI bolts, nuts, washer etc as required.(e) JUMPERS: 3 no 11kv acsr conductors mounted on pin typeinsularors as required.GENERAL:The go shall be operated by hand operated liver properlyearthed with provision for locking mounted at 3’ |
| 544 | Supply, Installation, Testing and commissioning of copper wound ISImarked Transformer 11/0.433 KV, Three Phase, 50 Hz, DYN 11,ONAN type , Standard accessories like, conservator, Silicagelbreather, radiator, fins, HT & LT cable end boxes or Bus Duct flange,Lifting lugs, Bi-directional Plain/ Flanged Rollers,Earthingterminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof 2.5%), winding / Top oil temperature rise of 45°C/40°C, ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxybased paint etc having max. total losses as per energy efficiencylevel - 2 at basic Insulation level conforming to IS 2026 (Part- I toPart - II), latest ammended and IS 1180 Part-I : 2014 BEE star level- I as per Govt. of India, Ministry of power notification Dated 16thDec., 2016. Transformers described as above and as per thefollowing continuous rating |
| 545 | 100 KVA |
| 546 | Providing & Laying XLPE insulated IS:7098/II/85 ofapproved make H.T.cable for working voltage 11K.V.Earthed with Stranded Compacted CircularAluminium Conductor, Conductor Screened withExtruded Semi-conducting compound, XLPE Insulated,Insulation Screened with extruded semi-conductingcompound in combination with Copper Tape, cores laidup, inner sheath of Thermoplastic tape, galvanised flatsteel strip armoured and overall Extruded PVC Type ST-2 Outer Sheathed cable direct in ground includingexcavation of 30cmx100cm size trench, 25cm layer ofriver sand, second Class bricks covering, refilling earth,compaction of earth, making necessary connectiontesting etc.as required of size. |
| 547 | 3 core 185.0 Sq.mm |
| 548 | Providing & making heat shrinkable type indoor/outdoor/straightthrough terminations/joint kit of approved make suitable for XLPEinsulated 11 KV cable, with required components, prepration ofcable ends,testing etc. as required of following sizes . |
| 549 | 3 core 120/150/185 Sq.mm |
| 550 | 3 core 120/150/185/225 Sq.mm |
| 551 | P/Laying XLPE insulated / P.V.C. sheathed cable of 1.1KV grade with aluminium conductor Armoured ofIS:7098-I/1554-1 approved make in ground as perIS:1255 including excavation of 30cmx75cm size trench,25 cm thick under layer of sand,IInd class brickscovering, refilling earth,compaction of earth, makingnecessary connection, testing etc. as required of size. |
| 552 | 3/CX4 sq mm |
| 553 | 4/CX10 sq mm |
| 554 | 3.5/CX95 sq mm |
| 555 | 3/CX10 sq mm |
| 556 | Providing & Laying XLPE/PVC PVC insulated & PVC Sheathed armoured control Cable of 1.1 KV grade with copper conductor as per IS 1275 including escavation of 30cmX 75 cm size trench 25 cm thick under layer of sand and lind class of bricks covering |
| 557 | 14CX1.5 sq mm |
| 558 | 5CX1.5 sq mm |
| 559 | Supplying and making one end termination with heavy duty doublecompression brass gland SIBG type, aluminium lugs duly crimpedwith crimping tool, PVC tape etc for following size of Armoured PVCinsulated & PVC sheathed/ XLPE aluminium conductor cable of1100 volt grade as required of size. |
| 560 | 3/CX10 sq mm |
| 561 | 3.5/CX95 sq mm |
| 562 | 4/C 10 sq mm |
| 563 | 3/CX4 sq mm |
| 564 | Supply, Fabricating & installing following sizes of perforated cabletrays including horizontal and vertical bends, reducers tees,crossmembers and other accessories as required and duly suspendedfrom the ceiling with suspenders and including painting as required. |
| 565 | 600mm x 50mm x 2.0mm |
| 566 | 150mm x 50mm x 1.6mm |
| 567 | Supply,installation,testing and commissionionig of floor mounted LV Switchboard (indoor dury,dust proof,vermin proof IP-4Xfront operated with 2 mm thick sheet metal compartmentalised) with all accessible parts,heat shrinkable sleeves,SMC/DMC bus bar supports, padlocking facility complete in all respect in line with SLD. |
| 568 | Supply Installation Testing & commissioning of Local Push button Station |
| 569 | SITC of microprocessor based intelligent power factor correctionrelay having sensitivity up to 50 milli Amp secondary current andfollowing way, self analysing auto c/k setting according to targetedpower factor setting, the relay shall have minimum three digit displayunit for display of real power factor, targeted power factor, lag/leadcapacitor switching status, alarm output for under current, overcurrent, insufficient compensation, indication of switching on units,auto/manual status, and shall have over load protection, no voltrelease etc. as required. |
| 570 | 6 to 14 stage - sensitivity upto 50 milli Amp. |
| 571 | SITC of self healing MPP/MP type shunt capacitor (banks)conforming to IS:13340-41 / IEC :831-1&2 in existing panel orparallel with load terminals , the capacitor shall be fitted withdischarge resistors, pressure sensitive disconnector ( PSD ) andshall have dissipation factor less than 0.0025 at 50 Hz and totalwattage loss less than 0.5 Watt per KVAR. including makingconnections with suitable capacity conductors/cables testing asrequired. |
| 572 | Heavy duty Three phase 440 V , 50 Hz capacitor (Bank) |
| 573 | Plate Earthing as per IS:3043 with copper Earth plate of size600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below theground level with 20 mm dia. G.I. \"B\" class watering Pipe including allaccessories like nut, bolts, reducer, nipple ,wire meshed funnel, andC.C. finished chamber covered with hinged type with lockingarrangement C.I. Cover, C.I. Frame of size300mm x 300mmcomplete with alternate layers of salt and coke/charcoal, testing ofearth resistance as required. |
| 574 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. of following size. |
| 575 | 50mm x 6mm G. I. strip |
| 576 | 25mm x 3mm Alum. Strip |
| 577 | Miscellaneous items Rubber mat,Danger Plate,Lugs,steel etc |
| 578 | Supply, Installation, Testing & Commissioning of HT meteringcubical panel as approved By DISCOMs fabricated out of 14 SWGCRCA sheet steel in two compartment & MS angle of size60mmX6mm having provision for Following:(i) Provision for fixing Trivector Meter (To be supplied by DISCOMs)(ii) Provision for fixing of combined CT PT Set (To be supplied byDISCOMs)(iii)TT Block(iv) 6mm Bakelite sheet on all sides. |
| 579 | Supply, Installation, testing and commissioning of 11 KV DoublePole structure With Air Break SWITCH having followingspecifications :(a) DP : Double pole structure made of two nos. 9 meter long PCCpoles (400 Kg) & 7 nos. MS Channel each of size 100mmx50mmx2500mm complete with earthing of the structure as perREC standards in all respect with nuts, springs washers, clamps asrequired.(b) GO:Off load type gang operated 3-pole vertical flute type switchsuitable for 11KV ; 400A ,3 phase, central post rotating double breakisolator complete with MS hardware , copper moving & fixed contact,assembly of 9 Nos pin insulator ,GI pipe of suitable length foroperation.c) DO: 3 Nos. Horizontal/Vertical mounted 33KV Horn Gap fuse set /Drop Out fuse set, 33KV barrel fuses mounted on 6 Nos. Postinsulators.(c) DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set/drop out 11kv barrel fuses mounted on 6no pin insulators(d) LA:3 piece non linear resistor type. lighting arrestor of approvedmake suitable for 3 wire, 11kv oh linewith rated voltage of 9kv rms &nominal discharge current rating of 5 ka & complete with galvanizedclamping arrangement GI bolts, nuts, washer etc as required.(e) JUMPERS: 3 no 11kv acsr conductors mounted on pin typeinsularors as required.GENERAL:The go shall be operated by hand operated liver properlyearthed with provision for locking mounted at 3’ |
| 580 | Supply, Installation, Testing and commissioning of copper wound ISImarked Transformer 11/0.433 KV, Three Phase, 50 Hz, DYN 11,ONAN type , Standard accessories like, conservator, Silicagelbreather, radiator, fins, HT & LT cable end boxes or Bus Duct flange,Lifting lugs, Bi-directional Plain/ Flanged Rollers,Earthingterminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof 2.5%), winding / Top oil temperature rise of 45°C/40°C, ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxybased paint etc having max. total losses as per energy efficiencylevel - 2 at basic Insulation level conforming to IS 2026 (Part- I toPart - II), latest ammended and IS 1180 Part-I : 2014 BEE star level- I as per Govt. of India, Ministry of power notification Dated 16thDec., 2016. Transformers described as above and as per thefollowing continuous rating |
| 581 | 630 KVA |
| 582 | Providing & Laying XLPE insulated IS:7098/II/85 ofapproved make H.T.cable for working voltage 11K.V.Earthed with Stranded Compacted CircularAluminium Conductor, Conductor Screened withExtruded Semi-conducting compound, XLPE Insulated,Insulation Screened with extruded semi-conductingcompound in combination with Copper Tape, cores laidup, inner sheath of Thermoplastic tape, galvanised flatsteel strip armoured and overall Extruded PVC Type ST-2 Outer Sheathed cable direct in ground includingexcavation of 30cmx100cm size trench, 25cm layer ofriver sand, second Class bricks covering, refilling earth,compaction of earth, making necessary connectiontesting etc.as required of size. |
| 583 | 3 core 185.0 Sq.mm |
| 584 | Providing & making heat shrinkable type indoor/outdoor/straightthrough terminations/joint kit of approved make suitable for XLPEinsulated 11 KV cable, with required components, prepration ofcable ends,testing etc. as required of following sizes . |
| 585 | 3 core 120/150/185 Sq.mm |
| 586 | 3 core 120/150/185/225 Sq.mm |
| 587 | P/Laying XLPE insulated / P.V.C. sheathed cable of 1.1KV grade with aluminium conductor Armoured ofIS:7098-I/1554-1 approved make in ground as perIS:1255 including excavation of 30cmx75cm size trench,25 cm thick under layer of sand,IInd class brickscovering, refilling earth,compaction of earth, makingnecessary connection, testing etc. as required of size. |
| 588 | 3/CX4 sq mm |
| 589 | 4/CX10 sq mm |
| 590 | 3/CX70 sq mm |
| 591 | 3/CX10 sq mm |
| 592 | 3/CX25 sq mm |
| 593 | 3/CX35 sq mm |
| 594 | 3/CX16sq mm |
| 595 | Providing & Laying XLPE/PVC PVC insulated & PVC Sheathed armoured control Cable of 1.1 KV grade with copper conductor as per IS 1275 including escavation of 30cmX 75 cm size trench 25 cm thick under layer of sand and lind class of bricks covering |
| 596 | 14CX1.5 sq mm |
| 597 | 5CX1.5 sq mm |
| 598 | Supplying and making one end termination with heavy duty doublecompression brass gland SIBG type, aluminium lugs duly crimpedwith crimping tool, PVC tape etc for following size of Armoured PVCinsulated & PVC sheathed/ XLPE aluminium conductor cable of1100 volt grade as required of size. |
| 599 | 4/C 10 sq mm |
| 600 | 3/CX4 sq mm |
| 601 | 3/CX70 sq mm |
| 602 | 3/CX10 sq mm |
| 603 | 3/CX25 sq mm |
| 604 | 3/CX35 sq mm |
| 605 | 3/CX16sq mm |
| 606 | Supply, Fabricating & installing following sizes of perforated cabletrays including horizontal and vertical bends, reducers tees,crossmembers and other accessories as required and duly suspendedfrom the ceiling with suspenders and including painting as required. |
| 607 | 600mm x 50mm x 2.0mm |
| 608 | 150mm x 50mm x 1.6mm |
| 609 | Supply,installation,testing and commissionionig of floor mounted LV Switchboard (indoor dury,dust proof,vermin proof IP-4Xfront operated with 2 mm thick sheet metal compartmentalised) with all accessible parts,heat shrinkable sleeves,SMC/DMC bus bar supports, padlocking facility complete in all respect in line with SLD. |
| 610 | Supply Installation Testing & commissioning of Local Push button Station |
| 611 | SITC of microprocessor based intelligent power factor correctionrelay having sensitivity up to 50 milli Amp secondary current andfollowing way, self analysing auto c/k setting according to targetedpower factor setting, the relay shall have minimum three digit displayunit for display of real power factor, targeted power factor, lag/leadcapacitor switching status, alarm output for under current, overcurrent, insufficient compensation, indication of switching on units,auto/manual status, and shall have over load protection, no voltrelease etc. as required. |
| 612 | 6 to 14 stage - sensitivity upto 50 milli Amp. |
| 613 | SITC of self healing MPP/MP type shunt capacitor (banks)conforming to IS:13340-41 / IEC :831-1&2 in existing panel orparallel with load terminals , the capacitor shall be fitted withdischarge resistors, pressure sensitive disconnector ( PSD ) andshall have dissipation factor less than 0.0025 at 50 Hz and totalwattage loss less than 0.5 Watt per KVAR. including makingconnections with suitable capacity conductors/cables testing asrequired. |
| 614 | Heavy duty Three phase 440 V , 50 Hz capacitor (Bank) |
| 615 | Plate Earthing as per IS:3043 with copper Earth plate of size600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below theground level with 20 mm dia. G.I. \"B\" class watering Pipe including allaccessories like nut, bolts, reducer, nipple ,wire meshed funnel, andC.C. finished chamber covered with hinged type with lockingarrangement C.I. Cover, C.I. Frame of size300mm x 300mmcomplete with alternate layers of salt and coke/charcoal, testing ofearth resistance as required. |
| 616 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. of following size. |
| 617 | 50mm x 6mm G. I. strip |
| 618 | 25mm x 3mm Alum. Strip |
| 619 | S.I.T.C. of bus trunking arrangement in convenient sectionscomplete with housing of galvanized sheet steel of minimum 1.5 mmthickness, aluminium bus bar for use on 3 phase, 4 wire, 415 volts,A.C. supply with degree of protection IP-42 for the following currentcarrying capacity, including jointing of sections, flexible joints.expansion joints, bends, and earthing with 2 runs of alum. strips etc.as required. |
| 620 | 1400 amps |
| 621 | Miscellaneous items Rubber mat,Danger Plate,Lugs,steel etc |
| 622 | P/Laying XLPE insulated / P.V.C. sheathed cable of 1.1KV grade with aluminium conductor Armoured ofIS:7098-I/1554-1 approved make in ground as perIS:1255 including excavation of 30cmx75cm size trench,25 cm thick under layer of sand,IInd class brickscovering, refilling earth,compaction of earth, makingnecessary connection, testing etc. as required of size. |
| 623 | 3/CX4 sq mm |
| 624 | 3/CX70 sq mm |
| 625 | 3.5/CX240sq mm |
| 626 | Providing & Laying XLPE/PVC PVC insulated & PVC Sheathed armoured control Cable of 1.1 KV grade with copper conductor as per IS 1275 including escavation of 30cmX 75 cm size trench 25 cm thick under layer of sand and lind class of bricks covering |
| 627 | 14CX1.5 sq mm |
| 628 | 5CX1.5 sq mm |
| 629 | Supplying and making one end termination with heavy duty doublecompression brass gland SIBG type, aluminium lugs duly crimpedwith crimping tool, PVC tape etc for following size of Armoured PVCinsulated & PVC sheathed/ XLPE aluminium conductor cable of1100 volt grade as required of size. |
| 630 | 3/CX4 sq mm |
| 631 | 3/CX70 sq mm |
| 632 | 3/CX240sq mm |
| 633 | Supply, Fabricating & installing following sizes of perforated cabletrays including horizontal and vertical bends, reducers tees,crossmembers and other accessories as required and duly suspendedfrom the ceiling with suspenders and including painting as required. |
| 634 | 600mm x 50mm x 2.0mm |
| 635 | 150mm x 50mm x 1.6mm |
| 636 | Supply,installation,testing and commissionionig of floor mounted LV Switchboard (indoor dury,dust proof,vermin proof IP-4Xfront operated with 2 mm thick sheet metal compartmentalised) with all accessible parts,heat shrinkable sleeves,SMC/DMC bus bar supports, padlocking facility complete in all respect in line with SLD. |
| 637 | Supply Installation Testing & commissioning of Local Push button Station |
| 638 | Plate Earthing as per IS:3043 with copper Earth plate of size600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below theground level with 20 mm dia. G.I. \"B\" class watering Pipe including allaccessories like nut, bolts, reducer, nipple ,wire meshed funnel, andC.C. finished chamber covered with hinged type with lockingarrangement C.I. Cover, C.I. Frame of size300mm x 300mmcomplete with alternate layers of salt and coke/charcoal, testing ofearth resistance as required. |
| 639 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. of following size. |
| 640 | 50mm x 6mm G. I. strip |
| 641 | 25mm x 3mm Alum. Strip |
| 642 | Miscellaneous items Rubber mat,Danger Plate,Lugs,steel etc |
| 643 | Supply, Installation, Testing & Commissioning of HT meteringcubical panel as approved By DISCOMs fabricated out of 14 SWGCRCA sheet steel in two compartment & MS angle of size60mmX6mm having provision for Following:(i) Provision for fixing Trivector Meter (To be supplied by DISCOMs)(ii) Provision for fixing of combined CT PT Set (To be supplied byDISCOMs)(iii)TT Block(iv) 6mm Bakelite sheet on all sides. |
| 644 | Supply, Installation, testing and commissioning of 11 KV DoublePole structure With Air Break SWITCH having followingspecifications :(a) DP : Double pole structure made of two nos. 9 meter long PCCpoles (400 Kg) & 7 nos. MS Channel each of size 100mmx50mmx2500mm complete with earthing of the structure as perREC standards in all respect with nuts, springs washers, clamps asrequired.(b) GO:Off load type gang operated 3-pole vertical flute type switchsuitable for 11KV ; 400A ,3 phase, central post rotating double breakisolator complete with MS hardware , copper moving & fixed contact,assembly of 9 Nos pin insulator ,GI pipe of suitable length foroperation.c) DO: 3 Nos. Horizontal/Vertical mounted 33KV Horn Gap fuse set /Drop Out fuse set, 33KV barrel fuses mounted on 6 Nos. Postinsulators.(c) DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set/drop out 11kv barrel fuses mounted on 6no pin insulators(d) LA:3 piece non linear resistor type. lighting arrestor of approvedmake suitable for 3 wire, 11kv oh linewith rated voltage of 9kv rms &nominal discharge current rating of 5 ka & complete with galvanizedclamping arrangement GI bolts, nuts, washer etc as required.(e) JUMPERS: 3 no 11kv acsr conductors mounted on pin typeinsularors as required.GENERAL:The go shall be operated by hand operated liver properlyearthed with provision for locking mounted at 3’ |
| 645 | Supply, Installation, Testing and commissioning of copper wound ISImarked Transformer 11/0.433 KV, Three Phase, 50 Hz, DYN 11,ONAN type , Standard accessories like, conservator, Silicagelbreather, radiator, fins, HT & LT cable end boxes or Bus Duct flange,Lifting lugs, Bi-directional Plain/ Flanged Rollers,Earthingterminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof 2.5%), winding / Top oil temperature rise of 45°C/40°C, ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxybased paint etc having max. total losses as per energy efficiencylevel - 2 at basic Insulation level conforming to IS 2026 (Part- I toPart - II), latest ammended and IS 1180 Part-I : 2014 BEE star level- I as per Govt. of India, Ministry of power notification Dated 16thDec., 2016. Transformers described as above and as per thefollowing continuous rating |
| 646 | 100 KVA |
| 647 | Providing & Laying XLPE insulated IS:7098/II/85 ofapproved make H.T.cable for working voltage 11K.V.Earthed with Stranded Compacted CircularAluminium Conductor, Conductor Screened withExtruded Semi-conducting compound, XLPE Insulated,Insulation Screened with extruded semi-conductingcompound in combination with Copper Tape, cores laidup, inner sheath of Thermoplastic tape, galvanised flatsteel strip armoured and overall Extruded PVC Type ST-2 Outer Sheathed cable direct in ground includingexcavation of 30cmx100cm size trench, 25cm layer ofriver sand, second Class bricks covering, refilling earth,compaction of earth, making necessary connectiontesting etc.as required of size. |
| 648 | 3 core 185.0 Sq.mm |
| 649 | Providing & making heat shrinkable type indoor/outdoor/straightthrough terminations/joint kit of approved make suitable for XLPEinsulated 11 KV cable, with required components, prepration ofcable ends,testing etc. as required of following sizes . |
| 650 | 3 core 120/150/185 Sq.mm |
| 651 | 3 core 120/150/185/225 Sq.mm |
| 652 | P/Laying XLPE insulated / P.V.C. sheathed cable of 1.1KV grade with aluminium conductor Armoured ofIS:7098-I/1554-1 approved make in ground as perIS:1255 including excavation of 30cmx75cm size trench,25 cm thick under layer of sand,IInd class brickscovering, refilling earth,compaction of earth, makingnecessary connection, testing etc. as required of size. |
| 653 | 3/CX4 sq mm |
| 654 | 4/CX10 sq mm |
| 655 | 3.5/CX95 sq mm |
| 656 | 3/CX10 sq mm |
| 657 | Providing & Laying XLPE/PVC PVC insulated & PVC Sheathed armoured control Cable of 1.1 KV grade with copper conductor as per IS 1275 including escavation of 30cmX 75 cm size trench 25 cm thick under layer of sand and lind class of bricks covering |
| 658 | 14CX1.5 sq mm |
| 659 | 5CX1.5 sq mm |
| 660 | Supplying and making one end termination with heavy duty doublecompression brass gland SIBG type, aluminium lugs duly crimpedwith crimping tool, PVC tape etc for following size of Armoured PVCinsulated & PVC sheathed/ XLPE aluminium conductor cable of1100 volt grade as required of size. |
| 661 | 3/CX10 sq mm |
| 662 | 3.5/CX95 sq mm |
| 663 | 4/C 10 sq mm |
| 664 | 3/CX4 sq mm |
| 665 | Supply, Fabricating & installing following sizes of perforated cabletrays including horizontal and vertical bends, reducers tees,crossmembers and other accessories as required and duly suspendedfrom the ceiling with suspenders and including painting as required. |
| 666 | 600mm x 50mm x 2.0mm |
| 667 | 150mm x 50mm x 1.6mm |
| 668 | Supply,installation,testing and commissionionig of floor mounted LV Switchboard (indoor dury,dust proof,vermin proof IP-4Xfront operated with 2 mm thick sheet metal compartmentalised) with all accessible parts,heat shrinkable sleeves,SMC/DMC bus bar supports, padlocking facility complete in all respect in line with SLD. |
| 669 | Supply Installation Testing & commissioning of Local Push button Station |
| 670 | SITC of microprocessor based intelligent power factor correctionrelay having sensitivity up to 50 milli Amp secondary current andfollowing way, self analysing auto c/k setting according to targetedpower factor setting, the relay shall have minimum three digit displayunit for display of real power factor, targeted power factor, lag/leadcapacitor switching status, alarm output for under current, overcurrent, insufficient compensation, indication of switching on units,auto/manual status, and shall have over load protection, no voltrelease etc. as required. |
| 671 | 6 to 14 stage - sensitivity upto 50 milli Amp. |
| 672 | SITC of self healing MPP/MP type shunt capacitor (banks)conforming to IS:13340-41 / IEC :831-1&2 in existing panel orparallel with load terminals , the capacitor shall be fitted withdischarge resistors, pressure sensitive disconnector ( PSD ) andshall have dissipation factor less than 0.0025 at 50 Hz and totalwattage loss less than 0.5 Watt per KVAR. including makingconnections with suitable capacity conductors/cables testing asrequired. |
| 673 | Heavy duty Three phase 440 V , 50 Hz capacitor (Bank) |
| 674 | Plate Earthing as per IS:3043 with copper Earth plate of size600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below theground level with 20 mm dia. G.I. \"B\" class watering Pipe including allaccessories like nut, bolts, reducer, nipple ,wire meshed funnel, andC.C. finished chamber covered with hinged type with lockingarrangement C.I. Cover, C.I. Frame of size300mm x 300mmcomplete with alternate layers of salt and coke/charcoal, testing ofearth resistance as required. |
| 675 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. of following size. |
| 676 | 50mm x 6mm G. I. strip |
| 677 | 25mm x 3mm Alum. Strip |
| 678 | Miscellaneous items Rubber mat,Danger Plate,Lugs,steel etc |
| 679 | Supply, Installation, Testing & Commissioning of HT meteringcubical panel as approved By DISCOMs fabricated out of 14 SWGCRCA sheet steel in two compartment & MS angle of size60mmX6mm having provision for Following:(i) Provision for fixing Trivector Meter (To be supplied by DISCOMs)(ii) Provision for fixing of combined CT PT Set (To be supplied byDISCOMs)(iii)TT Block(iv) 6mm Bakelite sheet on all sides. |
| 680 | Supply, Installation, testing and commissioning of 11 KV DoublePole structure With Air Break SWITCH having followingspecifications :(a) DP : Double pole structure made of two nos. 9 meter long PCCpoles (400 Kg) & 7 nos. MS Channel each of size 100mmx50mmx2500mm complete with earthing of the structure as perREC standards in all respect with nuts, springs washers, clamps asrequired.(b) GO:Off load type gang operated 3-pole vertical flute type switchsuitable for 11KV ; 400A ,3 phase, central post rotating double breakisolator complete with MS hardware , copper moving & fixed contact,assembly of 9 Nos pin insulator ,GI pipe of suitable length foroperation.c) DO: 3 Nos. Horizontal/Vertical mounted 33KV Horn Gap fuse set /Drop Out fuse set, 33KV barrel fuses mounted on 6 Nos. Postinsulators.(c) DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set/drop out 11kv barrel fuses mounted on 6no pin insulators(d) LA:3 piece non linear resistor type. lighting arrestor of approvedmake suitable for 3 wire, 11kv oh linewith rated voltage of 9kv rms &nominal discharge current rating of 5 ka & complete with galvanizedclamping arrangement GI bolts, nuts, washer etc as required.(e) JUMPERS: 3 no 11kv acsr conductors mounted on pin typeinsularors as required.GENERAL:The go shall be operated by hand operated liver properlyearthed with provision for locking mounted at 3’ |
| 681 | Supply, Installation, Testing and commissioning of copper wound ISImarked Transformer 11/0.433 KV, Three Phase, 50 Hz, DYN 11,ONAN type , Standard accessories like, conservator, Silicagelbreather, radiator, fins, HT & LT cable end boxes or Bus Duct flange,Lifting lugs, Bi-directional Plain/ Flanged Rollers,Earthingterminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof 2.5%), winding / Top oil temperature rise of 45°C/40°C, ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxybased paint etc having max. total losses as per energy efficiencylevel - 2 at basic Insulation level conforming to IS 2026 (Part- I toPart - II), latest ammended and IS 1180 Part-I : 2014 BEE star level- I as per Govt. of India, Ministry of power notification Dated 16thDec., 2016. Transformers described as above and as per thefollowing continuous rating |
| 682 | 200 KVA |
| 683 | Providing & Laying XLPE insulated IS:7098/II/85 ofapproved make H.T.cable for working voltage 11K.V.Earthed with Stranded Compacted CircularAluminium Conductor, Conductor Screened withExtruded Semi-conducting compound, XLPE Insulated,Insulation Screened with extruded semi-conductingcompound in combination with Copper Tape, cores laidup, inner sheath of Thermoplastic tape, galvanised flatsteel strip armoured and overall Extruded PVC Type ST-2 Outer Sheathed cable direct in ground includingexcavation of 30cmx100cm size trench, 25cm layer ofriver sand, second Class bricks covering, refilling earth,compaction of earth, making necessary connectiontesting etc.as required of size. |
| 684 | 3 core 185.0 Sq.mm |
| 685 | Providing & making heat shrinkable type indoor/outdoor/straightthrough terminations/joint kit of approved make suitable for XLPEinsulated 11 KV cable, with required components, prepration ofcable ends,testing etc. as required of following sizes . |
| 686 | 3 core 120/150/185 Sq.mm |
| 687 | 3 core 120/150/185/225 Sq.mm |
| 688 | P/Laying XLPE insulated / P.V.C. sheathed cable of 1.1KV grade with aluminium conductor Armoured ofIS:7098-I/1554-1 approved make in ground as perIS:1255 including excavation of 30cmx75cm size trench,25 cm thick under layer of sand,IInd class brickscovering, refilling earth,compaction of earth, makingnecessary connection, testing etc. as required of size. |
| 689 | 3/CX4 sq mm |
| 690 | 4/CX10 sq mm |
| 691 | 3/CX10 sq mm |
| 692 | 3.5/CX95 sq mm |
| 693 | 3/CX50 sq mm |
| 694 | Providing & Laying XLPE/PVC PVC insulated & PVC Sheathed armoured control Cable of 1.1 KV grade with copper conductor as per IS 1275 including escavation of 30cmX 75 cm size trench 25 cm thick under layer of sand and lind class of bricks covering |
| 695 | 14CX1.5 sq mm |
| 696 | 5CX1.5 sq mm |
| 697 | Supplying and making one end termination with heavy duty doublecompression brass gland SIBG type, aluminium lugs duly crimpedwith crimping tool, PVC tape etc for following size of Armoured PVCinsulated & PVC sheathed/ XLPE aluminium conductor cable of1100 volt grade as required of size. |
| 698 | 4/C 10 sq mm |
| 699 | 3/CX4 sq mm |
| 700 | 3/CX50 sq mm |
| 701 | 3/CX10 sq mm |
| 702 | 3.5/CX95 sq mm |
| 703 | Supply, Fabricating & installing following sizes of perforated cabletrays including horizontal and vertical bends, reducers tees,crossmembers and other accessories as required and duly suspendedfrom the ceiling with suspenders and including painting as required. |
| 704 | 600mm x 50mm x 2.0mm |
| 705 | 150mm x 50mm x 1.6mm |
| 706 | Supply,installation,testing and commissionionig of floor mounted LV Switchboard (indoor dury,dust proof,vermin proof IP-4Xfront operated with 2 mm thick sheet metal compartmentalised) with all accessible parts,heat shrinkable sleeves,SMC/DMC bus bar supports, padlocking facility complete in all respect in line with SLD. |
| 707 | Supply Installation Testing & commissioning of Local Push button Station |
| 708 | SITC of microprocessor based intelligent power factor correctionrelay having sensitivity up to 50 milli Amp secondary current andfollowing way, self analysing auto c/k setting according to targetedpower factor setting, the relay shall have minimum three digit displayunit for display of real power factor, targeted power factor, lag/leadcapacitor switching status, alarm output for under current, overcurrent, insufficient compensation, indication of switching on units,auto/manual status, and shall have over load protection, no voltrelease etc. as required. |
| 709 | 6 to 14 stage - sensitivity upto 50 milli Amp. |
| 710 | SITC of self healing MPP/MP type shunt capacitor (banks)conforming to IS:13340-41 / IEC :831-1&2 in existing panel orparallel with load terminals , the capacitor shall be fitted withdischarge resistors, pressure sensitive disconnector ( PSD ) andshall have dissipation factor less than 0.0025 at 50 Hz and totalwattage loss less than 0.5 Watt per KVAR. including makingconnections with suitable capacity conductors/cables testing asrequired. |
| 711 | Heavy duty Three phase 440 V , 50 Hz capacitor (Bank) |
| 712 | Plate Earthing as per IS:3043 with copper Earth plate of size600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below theground level with 20 mm dia. G.I. \"B\" class watering Pipe including allaccessories like nut, bolts, reducer, nipple ,wire meshed funnel, andC.C. finished chamber covered with hinged type with lockingarrangement C.I. Cover, C.I. Frame of size300mm x 300mmcomplete with alternate layers of salt and coke/charcoal, testing ofearth resistance as required. |
| 713 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. of following size. |
| 714 | 50mm x 6mm G. I. strip |
| 715 | 25mm x 3mm Alum. Strip |
| 716 | Miscellaneous items Rubber mat,Danger Plate,Lugs,steel etc |
| 717 | Supply, Installation, Testing & Commissioning of HT meteringcubical panel as approved By DISCOMs fabricated out of 14 SWGCRCA sheet steel in two compartment & MS angle of size60mmX6mm having provision for Following:(i) Provision for fixing Trivector Meter (To be supplied by DISCOMs)(ii) Provision for fixing of combined CT PT Set (To be supplied byDISCOMs)(iii)TT Block(iv) 6mm Bakelite sheet on all sides. |
| 718 | Supply, Installation, testing and commissioning of 11 KV DoublePole structure With Air Break SWITCH having followingspecifications :(a) DP : Double pole structure made of two nos. 9 meter long PCCpoles (400 Kg) & 7 nos. MS Channel each of size 100mmx50mmx2500mm complete with earthing of the structure as perREC standards in all respect with nuts, springs washers, clamps asrequired.(b) GO:Off load type gang operated 3-pole vertical flute type switchsuitable for 11KV ; 400A ,3 phase, central post rotating double breakisolator complete with MS hardware , copper moving & fixed contact,assembly of 9 Nos pin insulator ,GI pipe of suitable length foroperation.c) DO: 3 Nos. Horizontal/Vertical mounted 33KV Horn Gap fuse set /Drop Out fuse set, 33KV barrel fuses mounted on 6 Nos. Postinsulators.(c) DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set/drop out 11kv barrel fuses mounted on 6no pin insulators(d) LA:3 piece non linear resistor type. lighting arrestor of approvedmake suitable for 3 wire, 11kv oh linewith rated voltage of 9kv rms &nominal discharge current rating of 5 ka & complete with galvanizedclamping arrangement GI bolts, nuts, washer etc as required.(e) JUMPERS: 3 no 11kv acsr conductors mounted on pin typeinsularors as required.GENERAL:The go shall be operated by hand operated liver properlyearthed with provision for locking mounted at 3’ |
| 719 | Supply, Installation, Testing and commissioning of copper wound ISImarked Transformer 11/0.433 KV, Three Phase, 50 Hz, DYN 11,ONAN type , Standard accessories like, conservator, Silicagelbreather, radiator, fins, HT & LT cable end boxes or Bus Duct flange,Lifting lugs, Bi-directional Plain/ Flanged Rollers,Earthingterminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof 2.5%), winding / Top oil temperature rise of 45°C/40°C, ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxybased paint etc having max. total losses as per energy efficiencylevel - 2 at basic Insulation level conforming to IS 2026 (Part- I toPart - II), latest ammended and IS 1180 Part-I : 2014 BEE star level- I as per Govt. of India, Ministry of power notification Dated 16thDec., 2016. Transformers described as above and as per thefollowing continuous rating |
| 720 | 200 KVA |
| 721 | Providing & Laying XLPE insulated IS:7098/II/85 ofapproved make H.T.cable for working voltage 11K.V.Earthed with Stranded Compacted CircularAluminium Conductor, Conductor Screened withExtruded Semi-conducting compound, XLPE Insulated,Insulation Screened with extruded semi-conductingcompound in combination with Copper Tape, cores laidup, inner sheath of Thermoplastic tape, galvanised flatsteel strip armoured and overall Extruded PVC Type ST-2 Outer Sheathed cable direct in ground includingexcavation of 30cmx100cm size trench, 25cm layer ofriver sand, second Class bricks covering, refilling earth,compaction of earth, making necessary connectiontesting etc.as required of size. |
| 722 | 3 core 185.0 Sq.mm |
| 723 | Providing & making heat shrinkable type indoor/outdoor/straightthrough terminations/joint kit of approved make suitable for XLPEinsulated 11 KV cable, with required components, prepration ofcable ends,testing etc. as required of following sizes . |
| 724 | 3 core 120/150/185 Sq.mm |
| 725 | 3 core 120/150/185/225 Sq.mm |
| 726 | P/Laying XLPE insulated / P.V.C. sheathed cable of 1.1KV grade with aluminium conductor Armoured ofIS:7098-I/1554-1 approved make in ground as perIS:1255 including excavation of 30cmx75cm size trench,25 cm thick under layer of sand,IInd class brickscovering, refilling earth,compaction of earth, makingnecessary connection, testing etc. as required of size. |
| 727 | 3/CX4 sq mm |
| 728 | 4/CX10 sq mm |
| 729 | 3.5/CX150 sq mm |
| 730 | 3/CX10 sq mm |
| 731 | 3/CX35 sq mm |
| 732 | Providing & Laying XLPE/PVC PVC insulated & PVC Sheathed armoured control Cable of 1.1 KV grade with copper conductor as per IS 1275 including escavation of 30cmX 75 cm size trench 25 cm thick under layer of sand and lind class of bricks covering |
| 733 | 14CX1.5 sq mm |
| 734 | 5CX1.5 sq mm |
| 735 | Supplying and making one end termination with heavy duty doublecompression brass gland SIBG type, aluminium lugs duly crimpedwith crimping tool, PVC tape etc for following size of Armoured PVCinsulated & PVC sheathed/ XLPE aluminium conductor cable of1100 volt grade as required of size. |
| 736 | 4/C 10 sq mm |
| 737 | 3/CX4 sq mm |
| 738 | 3/CX150 sq mm |
| 739 | 3/CX10 sq mm |
| 740 | 3/CX35 sq mm |
| 741 | Supply, Fabricating & installing following sizes of perforated cabletrays including horizontal and vertical bends, reducers tees,crossmembers and other accessories as required and duly suspendedfrom the ceiling with suspenders and including painting as required. |
| 742 | 600mm x 50mm x 2.0mm |
| 743 | 150mm x 50mm x 1.6mm |
| 744 | Supply,installation,testing and commissionionig of floor mounted LV Switchboard (indoor dury,dust proof,vermin proof IP-4Xfront operated with 2 mm thick sheet metal compartmentalised) with all accessible parts,heat shrinkable sleeves,SMC/DMC bus bar supports, padlocking facility complete in all respect in line with SLD. |
| 745 | Supply Installation Testing & commissioning of Local Push button Station |
| 746 | SITC of microprocessor based intelligent power factor correctionrelay having sensitivity up to 50 milli Amp secondary current andfollowing way, self analysing auto c/k setting according to targetedpower factor setting, the relay shall have minimum three digit displayunit for display of real power factor, targeted power factor, lag/leadcapacitor switching status, alarm output for under current, overcurrent, insufficient compensation, indication of switching on units,auto/manual status, and shall have over load protection, no voltrelease etc. as required. |
| 747 | 6 to 14 stage - sensitivity upto 50 milli Amp. |
| 748 | SITC of self healing MPP/MP type shunt capacitor (banks)conforming to IS:13340-41 / IEC :831-1&2 in existing panel orparallel with load terminals , the capacitor shall be fitted withdischarge resistors, pressure sensitive disconnector ( PSD ) andshall have dissipation factor less than 0.0025 at 50 Hz and totalwattage loss less than 0.5 Watt per KVAR. including makingconnections with suitable capacity conductors/cables testing asrequired. |
| 749 | Heavy duty Three phase 440 V , 50 Hz capacitor (Bank) |
| 750 | Plate Earthing as per IS:3043 with copper Earth plate of size600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below theground level with 20 mm dia. G.I. \"B\" class watering Pipe including allaccessories like nut, bolts, reducer, nipple ,wire meshed funnel, andC.C. finished chamber covered with hinged type with lockingarrangement C.I. Cover, C.I. Frame of size300mm x 300mmcomplete with alternate layers of salt and coke/charcoal, testing ofearth resistance as required. |
| 751 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. of following size. |
| 752 | 50mm x 6mm G. I. strip |
| 753 | 25mm x 3mm Alum. Strip |
| 754 | Miscellaneous items Rubber mat,Danger Plate,Lugs,steel etc |
| 755 | Supply, Installation, Testing & Commissioning of HT meteringcubical panel as approved By DISCOMs fabricated out of 14 SWGCRCA sheet steel in two compartment & MS angle of size60mmX6mm having provision for Following:(i) Provision for fixing Trivector Meter (To be supplied by DISCOMs)(ii) Provision for fixing of combined CT PT Set (To be supplied byDISCOMs)(iii)TT Block(iv) 6mm Bakelite sheet on all sides. |
| 756 | Supply, Installation, testing and commissioning of 11 KV DoublePole structure With Air Break SWITCH having followingspecifications :(a) DP : Double pole structure made of two nos. 9 meter long PCCpoles (400 Kg) & 7 nos. MS Channel each of size 100mmx50mmx2500mm complete with earthing of the structure as perREC standards in all respect with nuts, springs washers, clamps asrequired.(b) GO:Off load type gang operated 3-pole vertical flute type switchsuitable for 11KV ; 400A ,3 phase, central post rotating double breakisolator complete with MS hardware , copper moving & fixed contact,assembly of 9 Nos pin insulator ,GI pipe of suitable length foroperation.c) DO: 3 Nos. Horizontal/Vertical mounted 33KV Horn Gap fuse set /Drop Out fuse set, 33KV barrel fuses mounted on 6 Nos. Postinsulators.(c) DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set/drop out 11kv barrel fuses mounted on 6no pin insulators(d) LA:3 piece non linear resistor type. lighting arrestor of approvedmake suitable for 3 wire, 11kv oh linewith rated voltage of 9kv rms &nominal discharge current rating of 5 ka & complete with galvanizedclamping arrangement GI bolts, nuts, washer etc as required.(e) JUMPERS: 3 no 11kv acsr conductors mounted on pin typeinsularors as required.GENERAL:The go shall be operated by hand operated liver properlyearthed with provision for locking mounted at 3’ |
| 757 | Supply, Installation, Testing and commissioning of copper wound ISImarked Transformer 11/0.433 KV, Three Phase, 50 Hz, DYN 11,ONAN type , Standard accessories like, conservator, Silicagelbreather, radiator, fins, HT & LT cable end boxes or Bus Duct flange,Lifting lugs, Bi-directional Plain/ Flanged Rollers,Earthingterminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof 2.5%), winding / Top oil temperature rise of 45°C/40°C, ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxybased paint etc having max. total losses as per energy efficiencylevel - 2 at basic Insulation level conforming to IS 2026 (Part- I toPart - II), latest ammended and IS 1180 Part-I : 2014 BEE star level- I as per Govt. of India, Ministry of power notification Dated 16thDec., 2016. Transformers described as above and as per thefollowing continuous rating |
| 758 | 200 KVA |
| 759 | Providing & Laying XLPE insulated IS:7098/II/85 ofapproved make H.T.cable for working voltage 11K.V.Earthed with Stranded Compacted CircularAluminium Conductor, Conductor Screened withExtruded Semi-conducting compound, XLPE Insulated,Insulation Screened with extruded semi-conductingcompound in combination with Copper Tape, cores laidup, inner sheath of Thermoplastic tape, galvanised flatsteel strip armoured and overall Extruded PVC Type ST-2 Outer Sheathed cable direct in ground includingexcavation of 30cmx100cm size trench, 25cm layer ofriver sand, second Class bricks covering, refilling earth,compaction of earth, making necessary connectiontesting etc.as required of size. |
| 760 | 3 core 185.0 Sq.mm |
| 761 | Providing & making heat shrinkable type indoor/outdoor/straightthrough terminations/joint kit of approved make suitable for XLPEinsulated 11 KV cable, with required components, prepration ofcable ends,testing etc. as required of following sizes . |
| 762 | 3 core 120/150/185 Sq.mm |
| 763 | 3 core 120/150/185/225 Sq.mm |
| 764 | P/Laying XLPE insulated / P.V.C. sheathed cable of 1.1KV grade with aluminium conductor Armoured ofIS:7098-I/1554-1 approved make in ground as perIS:1255 including excavation of 30cmx75cm size trench,25 cm thick under layer of sand,IInd class brickscovering, refilling earth,compaction of earth, makingnecessary connection, testing etc. as required of size. |
| 765 | 3/CX4 sq mm |
| 766 | 4/CX10 sq mm |
| 767 | 3.5/CX95 sq mm |
| 768 | 3/CX10 sq mm |
| 769 | 3/CX35 sq mm |
| 770 | Providing & Laying XLPE/PVC PVC insulated & PVC Sheathed armoured control Cable of 1.1 KV grade with copper conductor as per IS 1275 including escavation of 30cmX 75 cm size trench 25 cm thick under layer of sand and lind class of bricks covering |
| 771 | 14CX1.5 sq mm |
| 772 | 5CX1.5 sq mm |
| 773 | Supplying and making one end termination with heavy duty doublecompression brass gland SIBG type, aluminium lugs duly crimpedwith crimping tool, PVC tape etc for following size of Armoured PVCinsulated & PVC sheathed/ XLPE aluminium conductor cable of1100 volt grade as required of size. |
| 774 | 3/CX10 sq mm |
| 775 | 3.5/CX95 sq mm |
| 776 | 4/C 10 sq mm |
| 777 | 3/CX4 sq mm |
| 778 | 3/CX35 sq mm |
| 779 | Supply, Fabricating & installing following sizes of perforated cabletrays including horizontal and vertical bends, reducers tees,crossmembers and other accessories as required and duly suspendedfrom the ceiling with suspenders and including painting as required. |
| 780 | 600mm x 50mm x 2.0mm |
| 781 | 150mm x 50mm x 1.6mm |
| 782 | Supply,installation,testing and commissionionig of floor mounted LV Switchboard (indoor dury,dust proof,vermin proof IP-4Xfront operated with 2 mm thick sheet metal compartmentalised) with all accessible parts,heat shrinkable sleeves,SMC/DMC bus bar supports, padlocking facility complete in all respect in line with SLD. |
| 783 | Supply Installation Testing & commissioning of Local Push button Station |
| 784 | SITC of microprocessor based intelligent power factor correctionrelay having sensitivity up to 50 milli Amp secondary current andfollowing way, self analysing auto c/k setting according to targetedpower factor setting, the relay shall have minimum three digit displayunit for display of real power factor, targeted power factor, lag/leadcapacitor switching status, alarm output for under current, overcurrent, insufficient compensation, indication of switching on units,auto/manual status, and shall have over load protection, no voltrelease etc. as required. |
| 785 | 6 to 14 stage - sensitivity upto 50 milli Amp. |
| 786 | SITC of self healing MPP/MP type shunt capacitor (banks)conforming to IS:13340-41 / IEC :831-1&2 in existing panel orparallel with load terminals , the capacitor shall be fitted withdischarge resistors, pressure sensitive disconnector ( PSD ) andshall have dissipation factor less than 0.0025 at 50 Hz and totalwattage loss less than 0.5 Watt per KVAR. including makingconnections with suitable capacity conductors/cables testing asrequired. |
| 787 | Heavy duty Three phase 440 V , 50 Hz capacitor (Bank) |
| 788 | Plate Earthing as per IS:3043 with copper Earth plate of size600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below theground level with 20 mm dia. G.I. \"B\" class watering Pipe including allaccessories like nut, bolts, reducer, nipple ,wire meshed funnel, andC.C. finished chamber covered with hinged type with lockingarrangement C.I. Cover, C.I. Frame of size300mm x 300mmcomplete with alternate layers of salt and coke/charcoal, testing ofearth resistance as required. |
| 789 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. of following size. |
| 790 | 50mm x 6mm G. I. strip |
| 791 | 25mm x 3mm Alum. Strip |
| 792 | Miscellaneous items Rubber mat,Danger Plate,Lugs,steel etc |
| 793 | Supply, Installation, Testing & Commissioning of HT meteringcubical panel as approved By DISCOMs fabricated out of 14 SWGCRCA sheet steel in two compartment & MS angle of size60mmX6mm having provision for Following:(i) Provision for fixing Trivector Meter (To be supplied by DISCOMs)(ii) Provision for fixing of combined CT PT Set (To be supplied byDISCOMs)(iii)TT Block(iv) 6mm Bakelite sheet on all sides. |
| 794 | Supply, Installation, testing and commissioning of 11 KV DoublePole structure With Air Break SWITCH having followingspecifications :(a) DP : Double pole structure made of two nos. 9 meter long PCCpoles (400 Kg) & 7 nos. MS Channel each of size 100mmx50mmx2500mm complete with earthing of the structure as perREC standards in all respect with nuts, springs washers, clamps asrequired.(b) GO:Off load type gang operated 3-pole vertical flute type switchsuitable for 11KV ; 400A ,3 phase, central post rotating double breakisolator complete with MS hardware , copper moving & fixed contact,assembly of 9 Nos pin insulator ,GI pipe of suitable length foroperation.c) DO: 3 Nos. Horizontal/Vertical mounted 33KV Horn Gap fuse set /Drop Out fuse set, 33KV barrel fuses mounted on 6 Nos. Postinsulators.(c) DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set/drop out 11kv barrel fuses mounted on 6no pin insulators(d) LA:3 piece non linear resistor type. lighting arrestor of approvedmake suitable for 3 wire, 11kv oh linewith rated voltage of 9kv rms &nominal discharge current rating of 5 ka & complete with galvanizedclamping arrangement GI bolts, nuts, washer etc as required.(e) JUMPERS: 3 no 11kv acsr conductors mounted on pin typeinsularors as required.GENERAL:The go shall be operated by hand operated liver properlyearthed with provision for locking mounted at 3’ |
| 795 | Supply, Installation, Testing and commissioning of copper wound ISImarked Transformer 11/0.433 KV, Three Phase, 50 Hz, DYN 11,ONAN type , Standard accessories like, conservator, Silicagelbreather, radiator, fins, HT & LT cable end boxes or Bus Duct flange,Lifting lugs, Bi-directional Plain/ Flanged Rollers,Earthingterminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof 2.5%), winding / Top oil temperature rise of 45°C/40°C, ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxybased paint etc having max. total losses as per energy efficiencylevel - 2 at basic Insulation level conforming to IS 2026 (Part- I toPart - II), latest ammended and IS 1180 Part-I : 2014 BEE star level- I as per Govt. of India, Ministry of power notification Dated 16thDec., 2016. Transformers described as above and as per thefollowing continuous rating |
| 796 | 100 KVA |
| 797 | Providing & Laying XLPE insulated IS:7098/II/85 ofapproved make H.T.cable for working voltage 11K.V.Earthed with Stranded Compacted CircularAluminium Conductor, Conductor Screened withExtruded Semi-conducting compound, XLPE Insulated,Insulation Screened with extruded semi-conductingcompound in combination with Copper Tape, cores laidup, inner sheath of Thermoplastic tape, galvanised flatsteel strip armoured and overall Extruded PVC Type ST-2 Outer Sheathed cable direct in ground includingexcavation of 30cmx100cm size trench, 25cm layer ofriver sand, second Class bricks covering, refilling earth,compaction of earth, making necessary connectiontesting etc.as required of size. |
| 798 | 3 core 185.0 Sq.mm |
| 799 | Providing & making heat shrinkable type indoor/outdoor/straightthrough terminations/joint kit of approved make suitable for XLPEinsulated 11 KV cable, with required components, prepration ofcable ends,testing etc. as required of following sizes . |
| 800 | 3 core 120/150/185 Sq.mm |
| 801 | 3 core 120/150/185/225 Sq.mm |
| 802 | P/Laying XLPE insulated / P.V.C. sheathed cable of 1.1KV grade with aluminium conductor Armoured ofIS:7098-I/1554-1 approved make in ground as perIS:1255 including excavation of 30cmx75cm size trench,25 cm thick under layer of sand,IInd class brickscovering, refilling earth,compaction of earth, makingnecessary connection, testing etc. as required of size. |
| 803 | 3/CX4 sq mm |
| 804 | 4/CX10 sq mm |
| 805 | 3.5/CX95 sq mm |
| 806 | 3/CX10 sq mm |
| 807 | 3/CX16 sq mm |
| 808 | Providing & Laying XLPE/PVC PVC insulated & PVC Sheathed armoured control Cable of 1.1 KV grade with copper conductor as per IS 1275 including escavation of 30cmX 75 cm size trench 25 cm thick under layer of sand and lind class of bricks covering |
| 809 | 14CX1.5 sq mm |
| 810 | 5CX1.5 sq mm |
| 811 | Supplying and making one end termination with heavy duty doublecompression brass gland SIBG type, aluminium lugs duly crimpedwith crimping tool, PVC tape etc for following size of Armoured PVCinsulated & PVC sheathed/ XLPE aluminium conductor cable of1100 volt grade as required of size. |
| 812 | 3/CX10 sq mm |
| 813 | 3/CX16 sq mm |
| 814 | 3.5/CX95 sq mm |
| 815 | 4/C 10 sq mm |
| 816 | 3/CX4 sq mm |
| 817 | Supply, Fabricating & installing following sizes of perforated cabletrays including horizontal and vertical bends, reducers tees,crossmembers and other accessories as required and duly suspendedfrom the ceiling with suspenders and including painting as required. |
| 818 | 600mm x 50mm x 2.0mm |
| 819 | 150mm x 50mm x 1.6mm |
| 820 | Supply,installation,testing and commissionionig of floor mounted LV Switchboard (indoor dury,dust proof,vermin proof IP-4Xfront operated with 2 mm thick sheet metal compartmentalised) with all accessible parts,heat shrinkable sleeves,SMC/DMC bus bar supports, padlocking facility complete in all respect in line with SLD. |
| 821 | Supply Installation Testing & commissioning of Local Push button Station |
| 822 | SITC of microprocessor based intelligent power factor correctionrelay having sensitivity up to 50 milli Amp secondary current andfollowing way, self analysing auto c/k setting according to targetedpower factor setting, the relay shall have minimum three digit displayunit for display of real power factor, targeted power factor, lag/leadcapacitor switching status, alarm output for under current, overcurrent, insufficient compensation, indication of switching on units,auto/manual status, and shall have over load protection, no voltrelease etc. as required. |
| 823 | 6 to 14 stage - sensitivity upto 50 milli Amp. |
| 824 | SITC of self healing MPP/MP type shunt capacitor (banks)conforming to IS:13340-41 / IEC :831-1&2 in existing panel orparallel with load terminals , the capacitor shall be fitted withdischarge resistors, pressure sensitive disconnector ( PSD ) andshall have dissipation factor less than 0.0025 at 50 Hz and totalwattage loss less than 0.5 Watt per KVAR. including makingconnections with suitable capacity conductors/cables testing asrequired. |
| 825 | Heavy duty Three phase 440 V , 50 Hz capacitor (Bank) |
| 826 | Plate Earthing as per IS:3043 with copper Earth plate of size600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below theground level with 20 mm dia. G.I. \"B\" class watering Pipe including allaccessories like nut, bolts, reducer, nipple ,wire meshed funnel, andC.C. finished chamber covered with hinged type with lockingarrangement C.I. Cover, C.I. Frame of size300mm x 300mmcomplete with alternate layers of salt and coke/charcoal, testing ofearth resistance as required. |
| 827 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. of following size. |
| 828 | 50mm x 6mm G. I. strip |
| 829 | 25mm x 3mm Alum. Strip |
| 830 | Miscellaneous items Rubber mat,Danger Plate,Lugs,steel etc |
| 831 | Supply, Installation, Testing & Commissioning of HT meteringcubical panel as approved By DISCOMs fabricated out of 14 SWGCRCA sheet steel in two compartment & MS angle of size60mmX6mm having provision for Following:(i) Provision for fixing Trivector Meter (To be supplied by DISCOMs)(ii) Provision for fixing of combined CT PT Set (To be supplied byDISCOMs)(iii)TT Block(iv) 6mm Bakelite sheet on all sides. |
| 832 | Supply, Installation, testing and commissioning of 11 KV DoublePole structure With Air Break SWITCH having followingspecifications :(a) DP : Double pole structure made of two nos. 9 meter long PCCpoles (400 Kg) & 7 nos. MS Channel each of size 100mmx50mmx2500mm complete with earthing of the structure as perREC standards in all respect with nuts, springs washers, clamps asrequired.(b) GO:Off load type gang operated 3-pole vertical flute type switchsuitable for 11KV ; 400A ,3 phase, central post rotating double breakisolator complete with MS hardware , copper moving & fixed contact,assembly of 9 Nos pin insulator ,GI pipe of suitable length foroperation.c) DO: 3 Nos. Horizontal/Vertical mounted 33KV Horn Gap fuse set /Drop Out fuse set, 33KV barrel fuses mounted on 6 Nos. Postinsulators.(c) DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set/drop out 11kv barrel fuses mounted on 6no pin insulators(d) LA:3 piece non linear resistor type. lighting arrestor of approvedmake suitable for 3 wire, 11kv oh linewith rated voltage of 9kv rms &nominal discharge current rating of 5 ka & complete with galvanizedclamping arrangement GI bolts, nuts, washer etc as required.(e) JUMPERS: 3 no 11kv acsr conductors mounted on pin typeinsularors as required.GENERAL:The go shall be operated by hand operated liver properlyearthed with provision for locking mounted at 3’ |
| 833 | Supply, Installation, Testing and commissioning of copper wound ISImarked Transformer 11/0.433 KV, Three Phase, 50 Hz, DYN 11,ONAN type , Standard accessories like, conservator, Silicagelbreather, radiator, fins, HT & LT cable end boxes or Bus Duct flange,Lifting lugs, Bi-directional Plain/ Flanged Rollers,Earthingterminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof 2.5%), winding / Top oil temperature rise of 45°C/40°C, ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxybased paint etc having max. total losses as per energy efficiencylevel - 2 at basic Insulation level conforming to IS 2026 (Part- I toPart - II), latest ammended and IS 1180 Part-I : 2014 BEE star level- I as per Govt. of India, Ministry of power notification Dated 16thDec., 2016. Transformers described as above and as per thefollowing continuous rating |
| 834 | 315 KVA |
| 835 | Providing & Laying XLPE insulated IS:7098/II/85 ofapproved make H.T.cable for working voltage 11K.V.Earthed with Stranded Compacted CircularAluminium Conductor, Conductor Screened withExtruded Semi-conducting compound, XLPE Insulated,Insulation Screened with extruded semi-conductingcompound in combination with Copper Tape, cores laidup, inner sheath of Thermoplastic tape, galvanised flatsteel strip armoured and overall Extruded PVC Type ST-2 Outer Sheathed cable direct in ground includingexcavation of 30cmx100cm size trench, 25cm layer ofriver sand, second Class bricks covering, refilling earth,compaction of earth, making necessary connectiontesting etc.as required of size. |
| 836 | 3 core 185.0 Sq.mm |
| 837 | Providing & making heat shrinkable type indoor/outdoor/straightthrough terminations/joint kit of approved make suitable for XLPEinsulated 11 KV cable, with required components, prepration ofcable ends,testing etc. as required of following sizes . |
| 838 | 3 core 120/150/185 Sq.mm |
| 839 | 3 core 120/150/185/225 Sq.mm |
| 840 | P/Laying XLPE insulated / P.V.C. sheathed cable of 1.1KV grade with aluminium conductor Armoured ofIS:7098-I/1554-1 approved make in ground as perIS:1255 including excavation of 30cmx75cm size trench,25 cm thick under layer of sand,IInd class brickscovering, refilling earth,compaction of earth, makingnecessary connection, testing etc. as required of size. |
| 841 | 3/CX4 sq mm |
| 842 | 4/CX10 sq mm |
| 843 | 3.5/CX150 sq mm |
| 844 | 3/CX10 sq mm |
| 845 | 3/CX35 sq mm |
| 846 | 3/CX16 sq mm |
| 847 | 3/CX25 sq mm |
| 848 | Providing & Laying XLPE/PVC PVC insulated & PVC Sheathed armoured control Cable of 1.1 KV grade with copper conductor as per IS 1275 including escavation of 30cmX 75 cm size trench 25 cm thick under layer of sand and lind class of bricks covering |
| 849 | 14CX1.5 sq mm |
| 850 | 5CX1.5 sq mm |
| 851 | Supplying and making one end termination with heavy duty doublecompression brass gland SIBG type, aluminium lugs duly crimpedwith crimping tool, PVC tape etc for following size of Armoured PVCinsulated & PVC sheathed/ XLPE aluminium conductor cable of1100 volt grade as required of size. |
| 852 | 4/C 10 sq mm |
| 853 | 3/CX4 sq mm |
| 854 | 3/CX150 sq mm |
| 855 | 3/CX10 sq mm |
| 856 | 3/CX35 sq mm |
| 857 | 3/CX16 sq mm |
| 858 | 3/CX25 sq mm |
| 859 | Supply, Fabricating & installing following sizes of perforated cabletrays including horizontal and vertical bends, reducers tees,crossmembers and other accessories as required and duly suspendedfrom the ceiling with suspenders and including painting as required. |
| 860 | 600mm x 50mm x 2.0mm |
| 861 | 150mm x 50mm x 1.6mm |
| 862 | Supply,installation,testing and commissionionig of floor mounted LV Switchboard (indoor dury,dust proof,vermin proof IP-4Xfront operated with 2 mm thick sheet metal compartmentalised) with all accessible parts,heat shrinkable sleeves,SMC/DMC bus bar supports, padlocking facility complete in all respect in line with SLD. |
| 863 | Supply Installation Testing & commissioning of Local Push button Station |
| 864 | SITC of microprocessor based intelligent power factor correctionrelay having sensitivity up to 50 milli Amp secondary current andfollowing way, self analysing auto c/k setting according to targetedpower factor setting, the relay shall have minimum three digit displayunit for display of real power factor, targeted power factor, lag/leadcapacitor switching status, alarm output for under current, overcurrent, insufficient compensation, indication of switching on units,auto/manual status, and shall have over load protection, no voltrelease etc. as required. |
| 865 | 6 to 14 stage - sensitivity upto 50 milli Amp. |
| 866 | SITC of self healing MPP/MP type shunt capacitor (banks)conforming to IS:13340-41 / IEC :831-1&2 in existing panel orparallel with load terminals , the capacitor shall be fitted withdischarge resistors, pressure sensitive disconnector ( PSD ) andshall have dissipation factor less than 0.0025 at 50 Hz and totalwattage loss less than 0.5 Watt per KVAR. including makingconnections with suitable capacity conductors/cables testing asrequired. |
| 867 | Heavy duty Three phase 440 V , 50 Hz capacitor (Bank) |
| 868 | Plate Earthing as per IS:3043 with copper Earth plate of size600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below theground level with 20 mm dia. G.I. \"B\" class watering Pipe including allaccessories like nut, bolts, reducer, nipple ,wire meshed funnel, andC.C. finished chamber covered with hinged type with lockingarrangement C.I. Cover, C.I. Frame of size300mm x 300mmcomplete with alternate layers of salt and coke/charcoal, testing ofearth resistance as required. |
| 869 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. of following size. |
| 870 | 50mm x 6mm G. I. strip |
| 871 | 25mm x 3mm Alum. Strip |
| 872 | Miscellaneous items Rubber mat,Danger Plate,Lugs,steel etc |
| 873 | Supply, Installation, Testing & Commissioning of HT meteringcubical panel as approved By DISCOMs fabricated out of 14 SWGCRCA sheet steel in two compartment & MS angle of size60mmX6mm having provision for Following:(i) Provision for fixing Trivector Meter (To be supplied by DISCOMs)(ii) Provision for fixing of combined CT PT Set (To be supplied byDISCOMs)(iii)TT Block(iv) 6mm Bakelite sheet on all sides. |
| 874 | Supply, Installation, testing and commissioning of 11 KV DoublePole structure With Air Break SWITCH having followingspecifications :(a) DP : Double pole structure made of two nos. 9 meter long PCCpoles (400 Kg) & 7 nos. MS Channel each of size 100mmx50mmx2500mm complete with earthing of the structure as perREC standards in all respect with nuts, springs washers, clamps asrequired.(b) GO:Off load type gang operated 3-pole vertical flute type switchsuitable for 11KV ; 400A ,3 phase, central post rotating double breakisolator complete with MS hardware , copper moving & fixed contact,assembly of 9 Nos pin insulator ,GI pipe of suitable length foroperation.c) DO: 3 Nos. Horizontal/Vertical mounted 33KV Horn Gap fuse set /Drop Out fuse set, 33KV barrel fuses mounted on 6 Nos. Postinsulators.(c) DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set/drop out 11kv barrel fuses mounted on 6no pin insulators(d) LA:3 piece non linear resistor type. lighting arrestor of approvedmake suitable for 3 wire, 11kv oh linewith rated voltage of 9kv rms &nominal discharge current rating of 5 ka & complete with galvanizedclamping arrangement GI bolts, nuts, washer etc as required.(e) JUMPERS: 3 no 11kv acsr conductors mounted on pin typeinsularors as required.GENERAL:The go shall be operated by hand operated liver properlyearthed with provision for locking mounted at 3’ |
| 875 | Supply, Installation, Testing and commissioning of copper wound ISImarked Transformer 11/0.433 KV, Three Phase, 50 Hz, DYN 11,ONAN type , Standard accessories like, conservator, Silicagelbreather, radiator, fins, HT & LT cable end boxes or Bus Duct flange,Lifting lugs, Bi-directional Plain/ Flanged Rollers,Earthingterminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof 2.5%), winding / Top oil temperature rise of 45°C/40°C, ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxybased paint etc having max. total losses as per energy efficiencylevel - 2 at basic Insulation level conforming to IS 2026 (Part- I toPart - II), latest ammended and IS 1180 Part-I : 2014 BEE star level- I as per Govt. of India, Ministry of power notification Dated 16thDec., 2016. Transformers described as above and as per thefollowing continuous rating |
| 876 | 160 KVA |
| 877 | Providing & Laying XLPE insulated IS:7098/II/85 ofapproved make H.T.cable for working voltage 11K.V.Earthed with Stranded Compacted CircularAluminium Conductor, Conductor Screened withExtruded Semi-conducting compound, XLPE Insulated,Insulation Screened with extruded semi-conductingcompound in combination with Copper Tape, cores laidup, inner sheath of Thermoplastic tape, galvanised flatsteel strip armoured and overall Extruded PVC Type ST-2 Outer Sheathed cable direct in ground includingexcavation of 30cmx100cm size trench, 25cm layer ofriver sand, second Class bricks covering, refilling earth,compaction of earth, making necessary connectiontesting etc.as required of size. |
| 878 | 3 core 185.0 Sq.mm |
| 879 | Providing & making heat shrinkable type indoor/outdoor/straightthrough terminations/joint kit of approved make suitable for XLPEinsulated 11 KV cable, with required components, prepration ofcable ends,testing etc. as required of following sizes . |
| 880 | 3 core 120/150/185 Sq.mm |
| 881 | 3 core 120/150/185/225 Sq.mm |
| 882 | P/Laying XLPE insulated / P.V.C. sheathed cable of 1.1KV grade with aluminium conductor Armoured ofIS:7098-I/1554-1 approved make in ground as perIS:1255 including excavation of 30cmx75cm size trench,25 cm thick under layer of sand,IInd class brickscovering, refilling earth,compaction of earth, makingnecessary connection, testing etc. as required of size. |
| 883 | 3/CX4 sq mm |
| 884 | 4/CX10 sq mm |
| 885 | 3.5/CX150 sq mm |
| 886 | 3/CX10 sq mm |
| 887 | 3/CX16 sq mm |
| 888 | Providing & Laying XLPE/PVC PVC insulated & PVC Sheathed armoured control Cable of 1.1 KV grade with copper conductor as per IS 1275 including escavation of 30cmX 75 cm size trench 25 cm thick under layer of sand and lind class of bricks covering |
| 889 | 14CX1.5 sq mm |
| 890 | 5CX1.5 sq mm |
| 891 | Supplying and making one end termination with heavy duty doublecompression brass gland SIBG type, aluminium lugs duly crimpedwith crimping tool, PVC tape etc for following size of Armoured PVCinsulated & PVC sheathed/ XLPE aluminium conductor cable of1100 volt grade as required of size. |
| 892 | 4/C 10 sq mm |
| 893 | 3/CX4 sq mm |
| 894 | 3/CX150 sq mm |
| 895 | 3/CX10 sq mm |
| 896 | 3/CX16 sq mm |
| 897 | Supply, Fabricating & installing following sizes of perforated cabletrays including horizontal and vertical bends, reducers tees,crossmembers and other accessories as required and duly suspendedfrom the ceiling with suspenders and including painting as required. |
| 898 | 600mm x 50mm x 2.0mm |
| 899 | 150mm x 50mm x 1.6mm |
| 900 | Supply,installation,testing and commissionionig of floor mounted LV Switchboard (indoor dury,dust proof,vermin proof IP-4Xfront operated with 2 mm thick sheet metal compartmentalised) with all accessible parts,heat shrinkable sleeves,SMC/DMC bus bar supports, padlocking facility complete in all respect in line with SLD. |
| 901 | Supply Installation Testing & commissioning of Local Push button Station |
| 902 | SITC of microprocessor based intelligent power factor correctionrelay having sensitivity up to 50 milli Amp secondary current andfollowing way, self analysing auto c/k setting according to targetedpower factor setting, the relay shall have minimum three digit displayunit for display of real power factor, targeted power factor, lag/leadcapacitor switching status, alarm output for under current, overcurrent, insufficient compensation, indication of switching on units,auto/manual status, and shall have over load protection, no voltrelease etc. as required. |
| 903 | 6 to 14 stage - sensitivity upto 50 milli Amp. |
| 904 | SITC of self healing MPP/MP type shunt capacitor (banks)conforming to IS:13340-41 / IEC :831-1&2 in existing panel orparallel with load terminals , the capacitor shall be fitted withdischarge resistors, pressure sensitive disconnector ( PSD ) andshall have dissipation factor less than 0.0025 at 50 Hz and totalwattage loss less than 0.5 Watt per KVAR. including makingconnections with suitable capacity conductors/cables testing asrequired. |
| 905 | Heavy duty Three phase 440 V , 50 Hz capacitor (Bank) |
| 906 | Plate Earthing as per IS:3043 with copper Earth plate of size600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below theground level with 20 mm dia. G.I. \"B\" class watering Pipe including allaccessories like nut, bolts, reducer, nipple ,wire meshed funnel, andC.C. finished chamber covered with hinged type with lockingarrangement C.I. Cover, C.I. Frame of size300mm x 300mmcomplete with alternate layers of salt and coke/charcoal, testing ofearth resistance as required. |
| 907 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. of following size. |
| 908 | 50mm x 6mm G. I. strip |
| 909 | 25mm x 3mm Alum. Strip |
| 910 | Miscellaneous items Rubber mat,Danger Plate,Lugs,steel etc |
| 911 | Supply, Installation, Testing & Commissioning of HT meteringcubical panel as approved By DISCOMs fabricated out of 14 SWGCRCA sheet steel in two compartment & MS angle of size60mmX6mm having provision for Following:(i) Provision for fixing Trivector Meter (To be supplied by DISCOMs)(ii) Provision for fixing of combined CT PT Set (To be supplied byDISCOMs)(iii)TT Block(iv) 6mm Bakelite sheet on all sides. |
| 912 | Supply, Installation, testing and commissioning of 11 KV DoublePole structure With Air Break SWITCH having followingspecifications :(a) DP : Double pole structure made of two nos. 9 meter long PCCpoles (400 Kg) & 7 nos. MS Channel each of size 100mmx50mmx2500mm complete with earthing of the structure as perREC standards in all respect with nuts, springs washers, clamps asrequired.(b) GO:Off load type gang operated 3-pole vertical flute type switchsuitable for 11KV ; 400A ,3 phase, central post rotating double breakisolator complete with MS hardware , copper moving & fixed contact,assembly of 9 Nos pin insulator ,GI pipe of suitable length foroperation.c) DO: 3 Nos. Horizontal/Vertical mounted 33KV Horn Gap fuse set /Drop Out fuse set, 33KV barrel fuses mounted on 6 Nos. Postinsulators.(c) DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set/drop out 11kv barrel fuses mounted on 6no pin insulators(d) LA:3 piece non linear resistor type. lighting arrestor of approvedmake suitable for 3 wire, 11kv oh linewith rated voltage of 9kv rms &nominal discharge current rating of 5 ka & complete with galvanizedclamping arrangement GI bolts, nuts, washer etc as required.(e) JUMPERS: 3 no 11kv acsr conductors mounted on pin typeinsularors as required.GENERAL:The go shall be operated by hand operated liver properlyearthed with provision for locking mounted at 3’ |
| 913 | Supply, Installation, Testing and commissioning of copper wound ISImarked Transformer 11/0.433 KV, Three Phase, 50 Hz, DYN 11,ONAN type , Standard accessories like, conservator, Silicagelbreather, radiator, fins, HT & LT cable end boxes or Bus Duct flange,Lifting lugs, Bi-directional Plain/ Flanged Rollers,Earthingterminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof 2.5%), winding / Top oil temperature rise of 45°C/40°C, ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxybased paint etc having max. total losses as per energy efficiencylevel - 2 at basic Insulation level conforming to IS 2026 (Part- I toPart - II), latest ammended and IS 1180 Part-I : 2014 BEE star level- I as per Govt. of India, Ministry of power notification Dated 16thDec., 2016. Transformers described as above and as per thefollowing continuous rating |
| 914 | 160 KVA |
| 915 | Providing & Laying XLPE insulated IS:7098/II/85 ofapproved make H.T.cable for working voltage 11K.V.Earthed with Stranded Compacted CircularAluminium Conductor, Conductor Screened withExtruded Semi-conducting compound, XLPE Insulated,Insulation Screened with extruded semi-conductingcompound in combination with Copper Tape, cores laidup, inner sheath of Thermoplastic tape, galvanised flatsteel strip armoured and overall Extruded PVC Type ST-2 Outer Sheathed cable direct in ground includingexcavation of 30cmx100cm size trench, 25cm layer ofriver sand, second Class bricks covering, refilling earth,compaction of earth, making necessary connectiontesting etc.as required of size. |
| 916 | 3 core 185.0 Sq.mm |
| 917 | Providing & making heat shrinkable type indoor/outdoor/straightthrough terminations/joint kit of approved make suitable for XLPEinsulated 11 KV cable, with required components, prepration ofcable ends,testing etc. as required of following sizes . |
| 918 | 3 core 120/150/185 Sq.mm |
| 919 | 3 core 120/150/185/225 Sq.mm |
| 920 | P/Laying XLPE insulated / P.V.C. sheathed cable of 1.1KV grade with aluminium conductor Armoured ofIS:7098-I/1554-1 approved make in ground as perIS:1255 including excavation of 30cmx75cm size trench,25 cm thick under layer of sand,IInd class brickscovering, refilling earth,compaction of earth, makingnecessary connection, testing etc. as required of size. |
| 921 | 3/CX4 sq mm |
| 922 | 4/CX10 sq mm |
| 923 | 3.5/CX150 sq mm |
| 924 | 3/CX35 sq mm |
| 925 | 3/CX16 sq mm |
| 926 | Providing & Laying XLPE/PVC PVC insulated & PVC Sheathed armoured control Cable of 1.1 KV grade with copper conductor as per IS 1275 including escavation of 30cmX 75 cm size trench 25 cm thick under layer of sand and lind class of bricks covering |
| 927 | 14CX1.5 sq mm |
| 928 | 5CX1.5 sq mm |
| 929 | Supplying and making one end termination with heavy duty doublecompression brass gland SIBG type, aluminium lugs duly crimpedwith crimping tool, PVC tape etc for following size of Armoured PVCinsulated & PVC sheathed/ XLPE aluminium conductor cable of1100 volt grade as required of size. |
| 930 | 4/C 10 sq mm |
| 931 | 3/CX4 sq mm |
| 932 | 3/CX150 sq mm |
| 933 | 3/CX35 sq mm |
| 934 | 3/CX16 sq mm |
| 935 | Supply, Fabricating & installing following sizes of perforated cabletrays including horizontal and vertical bends, reducers tees,crossmembers and other accessories as required and duly suspendedfrom the ceiling with suspenders and including painting as required. |
| 936 | 600mm x 50mm x 2.0mm |
| 937 | 150mm x 50mm x 1.6mm |
| 938 | Supply,installation,testing and commissionionig of floor mounted LV Switchboard (indoor dury,dust proof,vermin proof IP-4Xfront operated with 2 mm thick sheet metal compartmentalised) with all accessible parts,heat shrinkable sleeves,SMC/DMC bus bar supports, padlocking facility complete in all respect in line with SLD. |
| 939 | Supply Installation Testing & commissioning of Local Push button Station |
| 940 | SITC of microprocessor based intelligent power factor correctionrelay having sensitivity up to 50 milli Amp secondary current andfollowing way, self analysing auto c/k setting according to targetedpower factor setting, the relay shall have minimum three digit displayunit for display of real power factor, targeted power factor, lag/leadcapacitor switching status, alarm output for under current, overcurrent, insufficient compensation, indication of switching on units,auto/manual status, and shall have over load protection, no voltrelease etc. as required. |
| 941 | 6 to 14 stage - sensitivity upto 50 milli Amp. |
| 942 | SITC of self healing MPP/MP type shunt capacitor (banks)conforming to IS:13340-41 / IEC :831-1&2 in existing panel orparallel with load terminals , the capacitor shall be fitted withdischarge resistors, pressure sensitive disconnector ( PSD ) andshall have dissipation factor less than 0.0025 at 50 Hz and totalwattage loss less than 0.5 Watt per KVAR. including makingconnections with suitable capacity conductors/cables testing asrequired. |
| 943 | Heavy duty Three phase 440 V , 50 Hz capacitor (Bank) |
| 944 | Plate Earthing as per IS:3043 with copper Earth plate of size600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below theground level with 20 mm dia. G.I. \"B\" class watering Pipe including allaccessories like nut, bolts, reducer, nipple ,wire meshed funnel, andC.C. finished chamber covered with hinged type with lockingarrangement C.I. Cover, C.I. Frame of size300mm x 300mmcomplete with alternate layers of salt and coke/charcoal, testing ofearth resistance as required. |
| 945 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. of following size. |
| 946 | 50mm x 6mm G. I. strip |
| 947 | 25mm x 3mm Alum. Strip |
| 948 | Miscellaneous items Rubber mat,Danger Plate,Lugs,steel etc |
| 949 | Construction of RCC Rectangular Clear water reservoirs of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab, top roof slab / dome, 20 mm thick cement plaster with water proofing compound in CM 1:3 proportion and food grade epoxy paint to inner face of the container and dome/slabv, including refilling and disposing of surplus stuff, all labour and material charges, providing and fixing accesories such asa M.S./Aluminium ladder/ RCC stairs inside and outside, manhole frame and cover, puddle collar, ventilators satisfactory hydraulic test and water tightness test as per IS code and providing three coats of cement paints to all exposed surface of structure including dome, etc. complete in all respect as per , design data, criteria, obligatory requirements and detailed specifications, scope of work and GA drawing. The job include painting the name of the scheme and other details on the reservoir and any other work related to structure (including chambers for valves etc.) as per directions of Engineer-in-charge, Technical specification and scope of work of following capacity. The rate is excluding the cost of pipes, specials and valves required for inlet, outlet, washout & overflow arrangement. |
| 950 | TPS 2 |
| 951 | CPS1 |
| 952 | TPS 3 CPS 2 |
| 953 | CPS 3 |
| 954 | CPS 4 |
| 955 | CPS 5 |
| 956 | TPS 4 for Town |
| 957 | TPS 4 for Rural |
| 958 | TPS 5 & CPS 6 |
| 959 | TPS 6 & CPS 7 |
| 960 | CPS 8 |
| 961 | CPS 9 |
| 962 | TPS 7 & CPS 10 |
| 963 | CPS 11 |
| 964 | CPS 12 |
| 965 | Fabrication, supply of flanged/ plain ended MS pipe made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete excluding flanged jointing wherever (required) including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. |
| 966 | MS pipe upto 600 mm dia (with minimum 5mm thickness sheet |
| 967 | MS pipe above 600mm dia (with minimum 6.3mm thickness sheet) |
| 968 | Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesof approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitablesupport structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 969 | 100 mm dia |
| 970 | 150 mm dia |
| 971 | 200 mm dia |
| 972 | 250 mm dia |
| 973 | 300 mm dia |
| 974 | 400 mm dia |
| 975 | 450 mm dia |
| 976 | 500 mm dia |
| 977 | 600 mm dia |
| 978 | Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. With gear |
| 979 | 700 mm dia |
| 980 | 800 mm dia |
| 981 | Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer. |
| 982 | 100 mm dia |
| 983 | 150 mm dia |
| 984 | 200 mm dia |
| 985 | 250 mm dia |
| 986 | 300 mm dia |
| 987 | 400 mm dia |
| 988 | 450 mm dia |
| 989 | 500 mm dia |
| 990 | 600 mm dia |
| 991 | MS700 mm dia |
| 992 | MS 800 mm dia |
| 993 | SITC of Ultrasonic Level Transmitter suitable for measuring water levelin reservoir, Normal Powered 24VDC, Type of Transmitter: Two Wire ( 4-20 mA), Cable Entry:1/2\" NPT (F), Sensor Material: PP, slip-on Flange: 2 ½” Flange, Material of Construction for Slip-on flange: PP, output 4~20mA, HART compatible,accuracy +/_ 0.2 % as per detailed Technical specification, scope of work and direction of Engineer in charge. |
| 994 | Measuring range 0.0 to 6.0 mtr |
| 995 | SCADA & Instrumentation |
| 996 | SITC ofUltrasonic Level Transmitter suitable for measuring water levelin reservoir, powered by solar panel with minimum 48 power back up or internal installed battery ( 5 years battery life with replacement warranty), with out put as GSM/GPRS + data logger , Sensor Material: PP, accuracy +/_ 0.2 %,as per detailed Technical specification, scope of work and direction of Engineer in charge. |
| 997 | Measuring range 0.0 to 6.0 mtr |
| 998 | SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) ,Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304,Electrode : SS AISI 316L /Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection with existing pipeline including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. |
| 999 | 80 mm dia |
| 1000 | 100 mm dia |
| 1001 | 150 mm dia |
| 1002 | 200 mm dia |
| 1003 | 250 mm dia |
| 1004 | Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA with HART / Diaphragm: SS316L / Process Connection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP671/2\" M (NPT) |
| 1005 | 11.3 SITC of Bulk Flow Meter with removable mechanism class \"B\" confirming to ISO: 4064: 2005/ IS:2373 of approved make of following dia sized pipelines and specifications complete: Media: Water (Clear), Temp. 50 deg., Pr. rating: PN16, Protection type: IP-68, Body Material: IS-210 Gr. FG-200, Accuracy Class: Class B (+ 2% @ Nominal flow rate), Magnetic Drive, Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 1006 | 80 mm dia |
| 1007 | 100 mm dia |
| 1008 | 125 mm dia |
| 1009 | 150 mm dia |
| 1010 | 200 mm dia |
| 1011 | 250 mm dia |
| 1012 | 300 mm dia |
| 1013 | Providing and fixing GSM/GPRS based data transmitter devicefor water meter compatible with SCADA system |
| 1014 | Supply,Installation,Testing and commissioning ofRTU Based VTC IP55 Panel with compact low-power RTU; Operated with battery or solar operated connection ext. Power Supply 10.8 V to 28.8 V DC. Integrated UMTS Modem: Connection to Tele Control Server Basic, DNP3-IEC 60870-5-104 and SINAUT ST7 Protocols, onboard I/Os:8 DI, 4 DO, 4 Al: FTP-Client:Ethernet Port, Configuration/Diagnostics via web server, time of day synchronization, SMS, Email, SD Card Slot etc. to the satisfaction of EIC.-operated power supply and suitable to communicate data to SMC/MCC as per scope of work and specifications,to the satisfaction of EIC |
| 1015 | Supply,Installation,Testing and commissioning of PLC Based Engineered IP 55 Automation Panel for 8 DI, 6 DO, 6 AI with rack mounted GPRS Module, Antenasuitable to communicate data to SMC/MCC as per scope of work and specifications,to the satisfaction of EIC |
| 1016 | Operation and Maintainance of System for 1st Year |
| 1017 | Operation and Maintainance of System for 2nd Year |
| 1018 | Operation and Maintainance of System for 3rd Year |
| 1019 | Operation and Maintainance of System for 4th Year |
| 1020 | Operation and Maintainance of System for 5th Year |
| 1021 | Operation and Maintainance of System for 6th Year |
| 1022 | Operation and Maintainance of System for 7th Year |
| 1023 | Operation and Maintainance of System for 8th Year |
| 1024 | Operation and Maintainance of System for 9th Year |
| 1025 | Operation and Maintainance of System for 10th Year |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy