Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #44887670

Tender For Field Emission Scanning Electron Microscope (Fe-Sem) + Eds,Stem And Its Accessories

Issued by Boards / Undertakings / PSU · Cochin, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
08 Sep 2024
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Offline

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Cochin → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for field emission scanning electron microscope (fe-sem) + eds,stem and its accessories 1 resolution in high vacuum mode - 0.7nm or better @ 15-20kv. - 1.3nm or better @ 1kv. - all the above claimed resolution should be supported by oem website or oem catalogue. - high resolution at lower kv should be achieved with or without beam deceleration or any other functions. 2 accelerating voltage it should be variable from 10v – 30kv or higher. 3 probe current in adjustable range from 1pa to 300na or higher. 4 magnification magnification should be 10,00,000x or higher. 5 electron gun - schottky type field emission gun with five years standard warranty. - there should be a necessary protection mechanism to protect the schottky type field emission gun during the long time power failure conditions. - fe gun should be replaced free of cost within in five years warranty period if it get failed whatever the reasons. 6 electron optics high resolution imaging should be possible at lower kv with beam deceleration or any other function. high resolution imaging of magnetic materials should be possible. the final objective lens must be combination of electrostatic/ magnetic lens or compound lens or hybrid lens. there should not be any sample restriction from conductive sample to non conductive sample. it should be easily possible with any type of magnetic samples as well. 7 user interface keyboard, mouse, touch screen monitor, control panel with multifunctions for the control and adjustment of frequently used fesem parameters. 8 specimen stage and chamber it should be 5 axis motorized fully eucentric stage with all motorized stage movements. - x= 100mm or higher -fully motorized. - y= 100mm or higher -fully motorized. - z=50 mm or higher -fully motorized. - rotation: 360° – fully motorized. - tilt: -3° or less to +70° or higher – fully motorized. - specimen chamber should be capable to accommodate larger size upto 200mm diameter and 50mm height. - specimen chabmber should be capable to upgrade all future possible detectors like stem, ebsd, wds, cl, etc., - atleast 6 or more ports shoudle be available for future expansion. - specimen chamber viewing camera should be included. 9 specimen exchange & vacuum system - specimen exchange should be possible through airlock/loadlock mechanism for easy and faster sample exchange. 10 sample holder multisampling specimen holder with 7 position or more should be provided. suitable specimen stubs to be provided – 50 numbers carbon tape – 2 nos should be supplied. 11 auto functions all auto functions like gun alignment, focus, stigmation, brightness, contrast, wobble and beam alignment should be automatic. 12 five imaging detectors should be offered 1. dedicated chamber mounted se everhart thornley detector. 2. dedicated retractable type back scattered electron detector. 3. dedicated inlens type/ through the lens type se detector for hr imaging. 4. dedicated in lens type / through the lens type bse detector for hr imaging. 5. stem detector should be included for bright field and dark field imaging. 13 one analysis detector - eds detector 5. eds system should be state of art system. - the offered eds detector should be ln2 free type. - the offered eds sensor should be silicon drift detector type - detector element area should be minimum 30mm2 or higher. - capable of quantifying elements ranging from berrilyum to uranium. - energy resolution should be < 129ev or better. - the offered eds software should have capable of live spectrum, live imaging. 14 computer/ workstation for microscope compatible computers with latest configuration, keyboard, mouse, monitor, latest windows licensed operating system preferably windows 11. 23-inch monitor square type, bezel less or better size should be included, one separately for eds image size:5120 x3840 pixel or better image depth: up to 16 bits or better. image format: bmp, tiff, jpeg,jpeg2000, gif, png etc. 15 spares and consumables essential required spares and consumables for trouble free operation of the instrument should be supplied along with instrument. eg.stubs, and carbon tape. 16 power supply over all power requirement of the instrument should be provided. (including peripherals like chiller and air compressor). instrument should be compatible with indian power standard conditions i.e, single phase (230v) / three phase (415v)@50hz power supply connectors of the instrument should be compatible with indian standards. 17 installation after installation and commission, 1-week training has to be provided on the operation, maintenance and application of the instrument at our site. 18 training should be provided separately by the competent factory trained engineer. 19 essential maintenance tools one set of essential maintenance tools must be supplied along with an instrument for regular operations and preventive maintenance work. 20 water chiller operating voltage- single phase 230vac, 50hz. ambient temperature- at least 32ºc acoustic noise level- less than 65dba @1m protection- over temperature & low water level. note :- water chiller should be compatible with supplied instrument and should be capable of working regular and continuous operation i.e. 24 x 7 operation. 21 air compressor (optional) acoustic noise level: : less than 65dba. ambient temperature: at least 35ºc operating voltage- single phase 230vac, 50hz size 22 other installaion accessories - 12kva ups with atleast 30min battery back up should be supplied. - regular n2 cylider with all necessary regulator – 1nos should be included. 23 site inspection bidders must conduct site survey after placement of po at no additional cost and all operation and installation related requirements should also be submitted. 24 onsite warranty three-years comprehensive on site warranty should be provided for all tendered item and five years fegun warranty should be included. sample preperation equipments. 25 gold coater

AI Tender Summary

OUR REF NO 44887670
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 08-09-2024
Authority
Authority Name Cochin University Of Science And Technology
Work Description Tender for field emission scanning electron microscope (fe-sem) + eds,stem and its accessories 1 resolution in high vacuum mode - 0.7nm or better @ 15-20kv. - 1.3nm or better @ 1kv. - all the above claimed resolution should be supported by oem website or oem catalogue. - high resolution at lower kv should be achieved with or without beam deceleration or any other functions. 2 accelerating voltage it should be variable from 10v – 30kv or higher. 3 probe current in adjustable range from 1pa to 300na or higher. 4 magnification magnification should be 10,00,000x or higher. 5 electron gun - schottky type field emission gun with five years standard warranty. - there should be a necessary protection mechanism to protect the schottky type field emission gun during the long time power failure conditions. - fe gun should be replaced free of cost within in five years warranty period if it get failed whatever the reasons. 6 electron optics high resolution imaging should be possible at lower kv with beam deceleration or any other function. high resolution imaging of magnetic materials should be possible. the final objective lens must be combination of electrostatic/ magnetic lens or compound lens or hybrid lens. there should not be any sample restriction from conductive sample to non conductive sample. it should be easily possible with any type of magnetic samples as well. 7 user interface keyboard, mouse, touch screen monitor, control panel with multifunctions for the control and adjustment of frequently used fesem parameters. 8 specimen stage and chamber it should be 5 axis motorized fully eucentric stage with all motorized stage movements. - x= 100mm or higher -fully motorized. - y= 100mm or higher -fully motorized. - z=50 mm or higher -fully motorized. - rotation: 360° – fully motorized. - tilt: -3° or less to +70° or higher – fully motorized. - specimen chamber should be capable to accommodate larger size upto 200mm diameter and 50mm height. - specimen chabmber should be capable to upgrade all future possible detectors like stem, ebsd, wds, cl, etc., - atleast 6 or more ports shoudle be available for future expansion. - specimen chamber viewing camera should be included. 9 specimen exchange & vacuum system - specimen exchange should be possible through airlock/loadlock mechanism for easy and faster sample exchange. 10 sample holder multisampling specimen holder with 7 position or more should be provided. suitable specimen stubs to be provided – 50 numbers carbon tape – 2 nos should be supplied. 11 auto functions all auto functions like gun alignment, focus, stigmation, brightness, contrast, wobble and beam alignment should be automatic. 12 five imaging detectors should be offered 1. dedicated chamber mounted se everhart thornley detector. 2. dedicated retractable type back scattered electron detector. 3. dedicated inlens type/ through the lens type se detector for hr imaging. 4. dedicated in lens type / through the lens type bse detector for hr imaging. 5. stem detector should be included for bright field and dark field imaging. 13 one analysis detector - eds detector 5. eds system should be state of art system. - the offered eds detector should be ln2 free type. - the offered eds sensor should be silicon drift detector type - detector element area should be minimum 30mm2 or higher. - capable of quantifying elements ranging from berrilyum to uranium. - energy resolution should be < 129ev or better. - the offered eds software should have capable of live spectrum, live imaging. 14 computer/ workstation for microscope compatible computers with latest configuration, keyboard, mouse, monitor, latest windows licensed operating system preferably windows 11. 23-inch monitor square type, bezel less or better size should be included, one separately for eds image size:5120 x3840 pixel or better image depth: up to 16 bits or better. image format: bmp, tiff, jpeg,jpeg2000, gif, png etc. 15 spares and consumables essential required spares and consumables for trouble free operation of the instrument should be supplied along with instrument. eg.stubs, and carbon tape. 16 power supply over all power requirement of the instrument should be provided. (including peripherals like chiller and air compressor). instrument should be compatible with indian power standard conditions i.e, single phase (230v) / three phase (415v)@50hz power supply connectors of the instrument should be compatible with indian standards. 17 installation after installation and commission, 1-week training has to be provided on the operation, maintenance and application of the instrument at our site. 18 training should be provided separately by the competent factory trained engineer. 19 essential maintenance tools one set of essential maintenance tools must be supplied along with an instrument for regular operations and preventive maintenance work. 20 water chiller operating voltage- single phase 230vac, 50hz. ambient temperature- at least 32ºc acoustic noise level- less than 65dba @1m protection- over temperature & low water level. note :- water chiller should be compatible with supplied instrument and should be capable of working regular and continuous operation i.e. 24 x 7 operation. 21 air compressor (optional) acoustic noise level: : less than 65dba. ambient temperature: at least 35ºc operating voltage- single phase 230vac, 50hz size 22 other installaion accessories - 12kva ups with atleast 30min battery back up should be supplied. - regular n2 cylider with all necessary regulator – 1nos should be included. 23 site inspection bidders must conduct site survey after placement of po at no additional cost and all operation and installation related requirements should also be submitted. 24 onsite warranty three-years comprehensive on site warranty should be provided for all tendered item and five years fegun warranty should be included. sample preperation equipments. 25 gold coater
Basic Detail
Tender No
Bidding Type Tender
Location
City Cochin
State Kerala
Key Dates
Publish Date 23 Aug 2024
Submission Date 08 Sep 2024
Open Date 01 Jan 0001
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
c4e50050-81f1-417e-8824-3aabd9eafed7.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 23, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 08, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

c4e50050-81f1-417e-8824-3aabd9eafed7.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders