| 1 | Sub Head - I ( Wiring ) Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (DSR 2022 - Item no.1.14.2) |
| 2 | Sub Head -II(Switchgear and earthing)Supplying and fixing of horizontal type three pole and nuetral sheet steel MCB distribution board, 415Volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, inter connections, powder painted including earthing etc., as required (but without MCB/RCCB/Isolator) 4 (8+12) way, Double door |
| 3 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, MCCB distribution board of sheet steel, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, inter connections, powder painted including earthing etc., as required (but without MCB/RCCB/Isolator)6 way, Double door |
| 4 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door (DSR 2022 Item 2.3.2) |
| 5 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required. (DSR 2022 Item 2.16) |
| 6 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts,\"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DBomplete with connections, testing and commissioning etc. as required.Single pole (DSR 2022 Item no.2.10.1) |
| 7 | Single pole and neutral (DSR 2022 Item no.2.10.2) |
| 8 | Supplying and fixing following rating, triple pole, 415 volts,\"C\" curve, miniature circuit breaker suitable for inductive load in the existing MCB DBomplete with connections, testing and commissioning etc. as required.63A |
| 9 | Providing and fixing following rating and breaking capacity and triple pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 A, 25 kA |
| 10 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR 2022 Item no.2.13.1) |
| 11 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. (DSR 2022 Item no.2.11) |
| 12 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 A(DSR 2022 Item No. 2.14.1) |
| 13 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A (DSR 2022 Item No. 2.15.2) |
| 14 | Sub Head - III ( Fittings )Supplying, installation, testing andcommissioning of Industrial Box type Luminaire batten suitable for twin T8 LED Tube on wall/truss for fixing LED tube and using department supplied LED tubes including connection, testing as required. |
| 15 | Supplying, installation, Testing and commissioning of 45 watt LED 5700K type LED streetlight made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection with impact resisitance of IK07 and fixing on truss /wall/ pole with suitable clamps and nut bolts including giving connection testing etc., at site of work as required. |
| 16 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (DSR 2022 Item no.19.1) |
| 17 | Sub Head - IV - Underground Cabling Works Supply of PVC insulated and PVC sheathed XPLE power cable of 1.1 KV grade armoured UG aluminium conductor cable conforming to IS 7098 part 1 with up-to-date amendment of the following size as required. 3 x 6 sq.mm |
| 18 | 3 x 10 sq.mm |
| 19 | 4 x 16 sq.mm |
| 20 | 4 × 25 sq.mm |
| 21 | 3.5 x 35 sq.mm |
| 22 | 3.5 x 50 sq.mm |
| 23 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required. 50 mm dia (DSR 2022 Item no.14.13.1, Civil DSR 2021 Item no.18.12.6) |
| 24 | 100 mm dia (DSR 2022 Item no.14.13.3) |
| 25 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm) (DSR 2022 - Item no. 9.1.2) |
| 26 | 3 X 10 sq. mm (22mm) (DSR 2022 - Item no. 9.1.7) |
| 27 | 4 X 16 sq. mm (28mm) (DSR 2022 - Item no. 9.1.33) |
| 28 | 4 X 25 sq.mm (28mm) (DSR 2022 -Item no.9.1.34) |
| 29 | 3.5 X 35 sq. mm (32mm) (DSR 2022 - Item no. 9.1.21) |
| 30 | 3.5 X 50 sq. mm (35mm) (DSR 2022 - Item no. 9.1.22) |
| 31 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Up to 35 Sq mm (DSR 2022 -Item no.7.3.1) |
| 32 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation excluding excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Up to 35 Sq mm(DSR 2022 Item no 7.4.1) |
| 33 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Up to 35 Sq mm (DSR 2022 -Item no.7.5.1) |
| 34 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) (DSR 2022 -Item no.7.7.1) |
| 35 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) (Civil DSR 2021 - Item no.4.1.8) |
| 36 | Supplying and fixing cable route marker with 10 cm x 10 cm x 5 cm thick G.I. plate with inscription there on, bolted/ welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. (DSR 2022 -Item no.7.10) |
| 37 | Supplying and fixing hot press molded SMC box SINTEX make of size 140x140x95 mm outside (GSJB 1414) with suitable clamps to the wall/pole/truss/G.I pipe, including providing and fixing of 3 way connections of suitable rating, providing and fixing 0.5 A Fuse with fuse holder, terminating the incoming and outgoing cables/wires (but with out end termination glands), making connections etc. as required. |
| 38 | Supplying and fixing hot press molded SMC box SINTEX make of size 140x140x95 mm outside (GSJB 1414) with suitable clamps to the wall/pole/truss/G.I pipe, including providing and fixing of 3 way connections of suitable rating, terminating the incoming and outgoing cables/wires (but with out end termination glands), making connections etc. as required. |
| 39 | Supplying and fixing hot press molded SMC box of size 250x200x100 mm outside with suitable clamps to the wall/pole/truss/GI Pipe, terminating the incoming and out going cables /wires (but with out end termination glands) making , making connections etc. as required. |
| 40 | Supplying and fixing hot press molded SMC Box of size 500 x 300 x 230mm with suitable clamps to the wall/pole/truss/GI Pipe with connector bar etc. as required. |
| 41 | Supplying and fixing hot press molded SMC Box of size 700 x 480 x 210mm with suitable clamps to the wall/pole/truss/GI Pipe, including providing and fixing of metal frame for mounting, concreting the metal frame, refixing existing starter, making connections etc. as required. |
| 42 | Supplying and fixing of 32 mm dia X 1.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. (Derived from DSR 2022 Item 12.34) |
| 43 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete asrequired.63 mm dia (OD-63 mm & ID-51 mm nominal) (DSR 2022 Item No.14.15.1) |
| 44 | Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 1 meter length along the pole for protection of under ground cable as required (Derived from DSR 2022 -Item no.12.37) |
| 45 | Sub Head - V(Credit Items)Credit value of followingdimantled obselete/unserviceable materials. Dismantled scrap of MS conduit/DB\"s/GI wire/clamps etc. |
| 46 | Dismantled scrap wire of Al.conductor cable. |
| 47 | Ceiling fan |
| 48 | Tube light fitting |
| 49 | Tube light |