| 1 | CIVIL WORK |
| 2 | 15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 3 | 15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar |
| 4 | 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 5 | 1.1.1_10:Disposal of materials by mechanical transportincluding loading ,unloading and stacking lime ,moorum, buildingrubbish lead for 10 km |
| 6 | 13.4.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand) |
| 7 | 13.18:Neat cement punning |
| 8 | 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 9 | 16.64:Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc.complete as per direction of Engineer-in- Charge. |
| 10 | OD22164/2023-2024:P/L CC Pavement of Mix M-20 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screen board vibrator, vaccum dewatering process and finally finished by floating, broming with wire brush etc. complete as per specifications and directions of Engineer-in-Charge. (The panel shuttering work shall be paid for separately). |
| 11 | 5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide |
| 12 | 16.46.1:Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade \"A\" sealing compound. |
| 13 | 19.19.4.1:Providing and fixing in position Pre-cast R.C.C. manhole cover and frame of required shape and approved quality.EHD - 35Circular shape 560 mm internal dia |
| 14 | 19.26.4:Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately :Circular manhole 140 cm dia with circular cover 600 mm dia of grade EHD - 35 |
| 15 | 6.1.2:Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 16 | 5.2.2A:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand incuding manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 20% : 3 graded stone aggregate 20 mm nominal size Recycled Concrete Aggregate (RCA) upto 20% |
| 17 | 110.12:P/F precast R.C.C. stab/grating 70mm thick manufactured with CC 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20 mm nominal size) reinforced with 96 kg/m3 of R.C.C including lapping all four side with M.S. sheet 1.6 mm thick & fixing in position complete. (Drain covers with or without holes) |
| 18 | 4.1.3A:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (1 cement : 2 coarse sand (zone-III) including manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 25% : 4 graded stone aggregate 20 mm nominal size Recycled Concrete Aggregate (RCA) upto 25%) |
| 19 | 4.1.10A:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:5:10 (1 cement : 5 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 10 graded stone aggregate 40 mm nominal size Recycled Aggregate (RA) ) |
| 20 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |