| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 28-08-2024 | EMD amount corrigendum | Fee | 12-09-2024 |
| Sl. No. | Item Description |
| 1 | Construction of new R.C.C Over Head Tank (OHT) |
| 2 | Design & supply of all material T&P etc and construct RCC over head Tank of following capacity and staging with RCC staircase & 1m wide balcony, G.I pipes ralling consisting of 3 rows of 20mm dia G.I pipe and angle iron posts around balcony and at the dome periphery, M.S. ladder from balcony to top of tank and inside the tank, locking device, ventilator, lightening, conductor, fixing of puddle collars and bell mouths, supply and fixing M.S. clamps with RCC column, fixing of digital level indicator, 25mm PCC 1:2:4 over 80mm PCC 1:4:8 in apron, 15mm semicircular drain around the tank, escape channel of 20m length, of box type enclosure at the entrance of the staircase having locking arrangements, two coats of apex paint and testing of tank for water tightness etc. and also including the cost of supply and fixing of all necessary pipes and valves etc all complete. as per approved design and drawing |
| 3 | Zone -2800KL/18M |
| 4 | Renovation of R.C.C Over Head Tank (OHT) |
| 5 | Dismantiling of OHT DemagedFlooring Scrappingofold Surface OHT leakage RepairingPressure GroutingCement and water Proofing Coumpond Chemicalinternal wall and bottom dome to making of water tightness oftank body Repairing of Railing of Stair and Balcony with 20mm GI Pipe including changing of old pipe and refixing new pipe with angle ironpost Supply and Fixing of MS Stair Gate with box in 1/2 flight primar and painting complete cover and steel mosqueteo mesh in ventilatorlightening conductor making proper earthing Supply and Fixing ofDigital Water Level IndicatorScafoldingfor repairing & Painting of OHT Shuttering centringflooring Painting two coats of approved paint Apex Ultima orOHT including supply of all materials, labour and T&P etc required for Proper completion of the work in External of whole OHT with writing Of Scheme Details in tank Body 65x65x6 angle MS Lader inside and outerside of tank bodyWith railingPaintingof inlet, outlet, overflow and washoutpipe with black japan paint and flow mark with white paint.sluice valve and chamberwith all material etc complete.,all work instructed by engineer in charge |
| 6 | Zone -1600KL/16M |
| 7 | Rising Main |
| 8 | Supply ofDI K-7/K-9 Pipes of follwing sizes (Dia in mm) / Thickness as IS 8329/2000 or its latest amendment with jointing materials, specials of sizes required during construction included jointing material upto site of work included loading unloading cartage insurance, etc all completed but exclusive of GST in various zone as per the drawing and approval to Engineer. |
| 9 | DI K-9 150mm Dia |
| 10 | Supply of following size ofSluice Valves/ Scour Valves,capable for working pressure of 10 kg/cm2 Fire hydrants & Air Valves as per relevent I.S.I or its latest amandement. Up to store Including loading, unloading & cartage, taxes duties insurance etc all complete. As per IS: 2906-1969. |
| 11 | D.I. D/F Sluice valve/ Scour valve 150 mm Dia |
| 12 | Cartage of following size (dia in mm.) of DI K-7/K-9 pipesand specials includingjointingmaterials from store to site of worklowering the same into excavated pipe line tenches true toaligment and gradidient and jointing the same including testing of pipe line including supply of all materials labaour T&P etc complete and as per direction of engineer incharge |
| 13 | D.I. K-9/ 150 mm |
| 14 | Carting of following size of Sluice Valves/ Scour Valves,from store to site of work and lowering them into the trenches, fixing in position and jointing them with Pipe line and testing etc including supply of jointing materialand also including supply of all material and construction of suitable P.C.C Support below fittings etc. complete. |
| 15 | D.I. D/F Sluice valve/ Scour valve /D.I. K-9/ 150 mm |
| 16 | Dismantling of following types of roads including sorting out of servicable matarials stacking and disposal of unservicable matarials with in a distance of 50 m. including supply of labour specials T&P etc. required for proper completion of work |
| 17 | Interlocking tile |
| 18 | C C Road |
| 19 | Bitumenous Road |
| 20 | B.O.E Road |
| 21 | Reinstatement of following type of road surfaces after laying of pipe line including sorting out of serviceable materials and disposal of unserviceable material Compaction with mechanical Vibrators as per specifications and tender document including supply of all materials labour T&P etc complete and as per direction of engineer incharge. |
| 22 | Interlocking tile |
| 23 | C C Road |
| 24 | Bitumenous Road |
| 25 | B.O.E Road |
| 26 | Excavation for pipe line trenches in ordinary soil use ofspecialT&P etc. with lift upto 1.5 m lead upto 50 mincluding filling back of excavated earth into trenches and watering ranmming dressing and removal of surpluas earth upto 50.m including supply of all materials labour T&P etc complete and as per direction of engineer incharge. |
| 27 | R.C.C. Thrust block with cement, core sand, and 20mm gauges stone ballast in propotion of 1: 1.5:3 in thrust block of pipe line including reinforcementand its bending the same with 0.08 mm thick binding wire in position and necessary shuttring including proper curing and supply of all materials, labour and T&P etc required for proper completion of work. |
| 28 | Thrust Block |
| 29 | Provision for Nala/ Culvert crossing including all materials, labour and T&P etc. complete. It includes supply of D.I. pipe of necessary size for encasing, cement concrete and Brickwork for pillars and any other job for proper completion of work. |
| 30 | For crossing of roadupto 3.5 m wide |
| 31 | For crossing ofnalla/culvert/road upto 3.5 m wide(Trenchless) |
| 32 | Constuction of following type of chamber as per type design & drawing & as per diretion of engineer incharge including all supply of materials etc. |
| 33 | Sluice valve/Scour Valve chamber (Masonary type ) |
| 34 | Distribution System |
| 35 | Supply ofHDPE Pipes grade PE 100/ PN 6 of follwing sizes (Dia in mm) / Thickness as IS 4984/2016 or its latest amendment with electrofusion jointing materials, specials and fittings of sizes required during construction included jointing material upto site of work included loading unloading cartage insurance, etc all completed but exclusive of GST in various zone as per the drawing and approval to Engineer. |
| 36 | HDPE PIPE GRADE PE 100/ PN 6- 90 mm |
| 37 | HDPE PIPE GRADE PE 100/ PN 6- 110 mm |
| 38 | HDPE PIPE GRADE PE 100/ PN 6- 140 mm |
| 39 | HDPE PIPE GRADE PE 100/ PN 6- 160 mm |
| 40 | D.I. K-7/ 200 mm |
| 41 | D.I. K-7/ 250 mm |
| 42 | D.I. K-7/ 300mm |
| 43 | Supply of following size ofSluice Valves/ Scour Valves,capable for working pressure of 10 kg/cm2 Fire hydrants & Air Valves as per relerelavent I.S.I or its latest amandement. Up to store Including loading, unloading & cartage, taxes duties insurance etc all complete. As per IS: 2906-1969. |
| 44 | Air Valve as per as I.S : 14845 |
| 45 | 25 mm dia |
| 46 | D.I. D/F Sluice valve/ Scour valve |
| 47 | 80 mm dia. |
| 48 | 100 mm dia. |
| 49 | 125 mm dia. |
| 50 | 200 mm dia. |
| 51 | 250 mm dia. |
| 52 | Fire hydrant (80 mm dia.) |
| 53 | Dismantling of following types of roads including sorting out of servicable matarials stacking and disposal of unservicable matarials with in a distance of 50 m. including supply of labour specials T&P etc. required for proper completion of work |
| 54 | Interlocking tile |
| 55 | C.C Road |
| 56 | Bituminous Road |
| 57 | B.O.E Road |
| 58 | Excavation for pipe line trenches in Ordinary soil requiring use ofspecialT&P etc. with lift upto 1.5 m lead upto 50 mincluding filling back of excavated earth into trenches and watering ranmming dressing and removal of surpluas earth upto 50.m including supply of alllabour T&P etc complete and as per direction of engineer incharge. |
| 59 | Cartage fromstore to site of work for following size (dia in mm)HDPE pipes and Specials coupling, fittings, and lowering the same into trenches and laying true to alignment and gradiant including testing of pipe lines cuttings of pipes for making up the length and making joints with electrofusion couplers, bands, tees, endcap etc. with electrofusion machinery including all jointing materials, labour, T&P etc required for proper completion of work. (excluding cost of trenching) |
| 60 | HDPE PIPE GRADE PE 100/ PN 6- 90 mm |
| 61 | HDPE PIPE GRADE PE 100/ PN 6- 110 mm |
| 62 | HDPE PIPE GRADE PE 100/ PN 6- 140 mm |
| 63 | HDPE PIPE GRADE PE 100/ PN 6- 160 mm |
| 64 | Cartage of DI K-7 pipes and specials of following size (dia in mm)from store to site of work, lowering them into trenches and laying true to alignment and gradiant including testing of pipe line but excluding cost of trenching including all supply of Labour T&P etc complete required for proper completion of work. |
| 65 | D.I. K-7/ 200 mm |
| 66 | D.I. K-7/ 250 mm |
| 67 | D.I. K-7/ 300mm |
| 68 | Carting of following size of Sluice Valves/ Scour Valves, Fire hydrants & Air Valves from store to site of work and lowering them into the trenches, fixing in position and jointing them with Pipe line and testing etc including supply of jointing materialand also including supply of all material and construction of suitable P.C.C Support below fittings etc. complete. |
| 69 | 20 mm. dia Air Valve |
| 70 | D.I. D/F Sluice valve/ Scour valve |
| 71 | 80 mm dia. |
| 72 | 100 mm dia. |
| 73 | 125 mm dia. |
| 74 | 200 mm dia. |
| 75 | 250 mm dia. |
| 76 | Fire hydrant (80 mm dia.) |
| 77 | R.C.C. Thrust block with cement, core sand, and 20mm gauges stone ballast in propotion of 1: 1.5:3 in thrust block of pipe line including reinforcementand its bending the same with 0.08 mm thick binding wire in position and necessary shuttring including proper curing and supply of all materials, labour and T&P etc required for proper completion of work. |
| 78 | Reinstatement of following type of road surfaces after laying of pipe line including sorting out of serviceable materials and disposal of unserviceable material Compaction with mechanical Vibrators as per specifications and tender document including supply of all materials labour T&P etc complete and as per direction of engineer incharge. |
| 79 | Interlocking tile |
| 80 | C.C Road |
| 81 | Bitumenous Road |
| 82 | B.O.E Road |
| 83 | Constuction of following type of chamber as per type design & drawing & as per diretion of engineer incharge including all supply of materials etc. |
| 84 | Sluice valve chamber |
| 85 | Scour Valve Chamber |
| 86 | Air Valve chamber |
| 87 | fire hydrant chamber |
| 88 | Provision for Nala/Culvert/road crossing including all materials, labour and T&P etc. complete. It includes supply of D.I. pipe of necessary size for encasing, cement concrete and Brickwork for pillars and any other job for proper completion of work. |
| 89 | For crossing ofnalla/culvert/road upto 3.5 m wide(Trenchless) |
| 90 | For crossing ofRoad upto7 m wide(Trenchless) |
| 91 | Sifting of HOUSE CONNECTION |
| 92 | Shifting of house connection from extsting distribution line to new pipe line in followingdia,withsupply of H.D.P.E. Average 6.00 mtr includingelectrofusion specials, Brass ferrule, Electrofusion Saddle clamp,tee bend ,union ,brass tap etc. of suitable size, resting on cc platform below ground level T&P etc. including excavation, laying and jointing for proper completion of work as per instructions of Engineer-in-charge includingthe cost of baling out and subsequent backfilland repair of subsequent leakages of joints, fittings and specials during work. |
| 93 | In C.C. Roads |
| 94 | For 90 mm to 110mm dia |
| 95 | For 125 mm to 160 mm dia |
| 96 | For 200 mm to 250 mm dia |
| 97 | In Bitumenous Roads |
| 98 | For 90 mm to 110mm dia |
| 99 | For 125 mm to 160 mm dia |
| 100 | For 200 mm to 250 mm dia |
| 101 | In B.O.E. Roads |
| 102 | For 90 mm to 110mm dia |
| 103 | For 125 mm to 160 mm dia |
| 104 | In C.C. Interlocking Tiles Roads |
| 105 | For 90 mm to 110mm dia |
| 106 | For 125 mm to 160 mm dia |
| 107 | For 200 mm to 250 mm dia |
| 108 | In Kacha Roads |
| 109 | For 90 mm to 110 mm dia |
| 110 | New House Connection |
| 111 | Making new House Connectionwith Distribution main of following dia and type of road including Dismantling and Reinstatement of road . Supply, cartingof elecrofusion specials as Saddel ,Tee ,Bend,brass ferrule, Union,H.D.P.E. pipe , HDPE adeptor ,GI pipe for drain crossing and avobe GL,loweringtheminto trenches , fixing them with CC block and clampincluding bailing out of water necessary excavation for connection with brass Tap including all labour , T&P etc. required for proper completion of the work. |
| 112 | In C.C. Roads |
| 113 | For 90 mm to 110mm dia |
| 114 | For 125 mm to 160 mm dia |
| 115 | For 200 mm to 250 mm dia |
| 116 | For 250 mm to 300mm dia |
| 117 | In Bitumenous Roads |
| 118 | For 90 mm to 110mm dia |
| 119 | For 125 mm to 160 mm dia |
| 120 | For 200 mm to 250 mm dia |
| 121 | In B.O.E. Roads |
| 122 | For 90 mm to 110mm dia |
| 123 | For 125 mm to 160 mm dia |
| 124 | For 200 mm to 250 mm dia |
| 125 | In C.C. Interlocking Tiles Roads |
| 126 | For 90 mm to 110mm dia |
| 127 | For 125 mm to 160 mm dia |
| 128 | For 200 mm to 250 mm dia |
| 129 | In Kacha Roads |
| 130 | For 90 mm to 110 mm dia |
| 131 | For 125 mm to 160 mm dia |
| 132 | For 200 mm to 250 mm dia |
| 133 | MISCELLANEOUS WORK |
| 134 | Construction of Pump House Cum Chloroneb (3.0 M X 2.5 M X 3.0 M , 1.8M X 1.2 M X 3.0 M, 1.5 WIDE VARANDAH)as per approved drawing and design based on RCCsingle reamed pile foundation , foundation beam, D.P.C. ,Ist class brick work ,M.S. Angle iron chaukhat of 50mm x 50mm x 6mm size for doors and windows, lintels, sun, shades slab etc,t concrete floor andapron on all sides ,by pass chamber ,Painting and varnishing of new iron work with one coat priming and two coat of approved apex paint and varnish ,Finishing walls with waterproof cement paint of approved make and quality yover one priming coat on new work with two coats to give an even shade, Supply of all material labour T&p complete as per instruction of engineer in charge. |
| 135 | Zone-2 |
| 136 | Repairing of Pump HouseAs required including Ist class brick work ,M.S. Angle iron chaukhat of 50mm x 50mm x 6mm size for doors and windows, lintels, sun, shades slab etc,t concrete floor andapron on all sides ,bypasschamber,Painting and varnishing of new iron work with one coat priming and two coat of approved apex paint and varnish,Finishing walls with waterproof cement paint of approved make and qualityover o ne priming coat on old work with two coats to give an even shade,Supply |
| 137 | Master control scada room(5.0x4.5x4.0m) zone-2as per approved drawing and design based on RCCsingle reamed pile foundation , foundation beam, D.P.C. ,Ist class brick work ,M.S. Angle iron chaukhat of 50mm x 50mm x 6mm size for doors and windows, lintels, sun, shades slab etc,t concrete floor andapron on all sides ,by pass chamber ,Painting and varnishing of new iron work with one coat priming and two coat of approved apex paint and varnish ,Finishing walls with waterproof cement paint of approved make and quality yover one priming coat on new work with two coats to give an even shade, Supply of all material labour T&p complete as per instruction of engineer in charge |
| 138 | Construction of RCC Pillar for rebore tubewell( zone 1&zone2) |
| 139 | Construnction of a half set of (area 45 sqm) one no. single Room staff quarters for Operator staff, pump operator , chaukidaar, pump attendent and other as per approved drawing and design based on RCCsingle reamed pile foundation , foundation beam, D.P.C. ,Ist class brick work ,M.S. Angle iron chaukhat of 50mm x 50mm x 6mm size for doors and windows, lintels, sun, shades slab etc,concrete floor andapron on all sides ,by pass chamber ,Painting and varnishing of new iron work with one coat priming and two coat of approved apex paint and varnish ,Finishing walls with waterproof cement paint of approved make and quality yover one priming coat on new work with two coats to give an even shade, Supply of all material labour T&p complete as per instruction of engineer in charge |
| 140 | Repairing of Staff Quarter zone-1 |
| 141 | zone 2 new construction staff quarter |
| 142 | Construnction of Boundary Wall including supply all materials, labour, T&P etc required for proper completion of work as per type design |
| 143 | Repairing of Boundary Wall including supply all materials, labour, T&P etc required for proper completion of work as direction of engineer incharge. |
| 144 | Construction of 1.8m high boundary wall on pile foundation as per approved design and drawingand as per specification given in bid document inluding painting with 2 coats of all waether apex paint over one coat primer painting primer coat including supply of all material labour T&P etc for propercompletion of works as per instruction of engineer in charge.zone 2 new construction boundary |
| 145 | Painting work in Boundary Wall zone-1 ncluding supply all materials, labour, T&P etc required for proper completion of work |
| 146 | Supply and fixing 3.60 M & 1.20 M wide MS Gate with pillars including fabrication and supply of steel and construnction ofboundary pillars etc complete. |
| 147 | Provide all materials, labour, T&P etc Required for proper completion of work and construct Interlovking Tiles approach road, laid dry and joints intact with coarse sand mortar including preparation of base etc |
| 148 | Water Campus Zone 1 |
| 149 | Water Campus Zone 2 |
| 150 | Construnction of Drain in Water works Campus30 x 30 cm including labour material and t&p all complete |
| 151 | Zone-1 |
| 152 | Zone-2 |
| 153 | Filling of earth of lower portion including carting of earth upto 10 km including ramming , levelling and dressing at water works campus. |
| 154 | Zone-3 |
| 155 | TUBEWELLCONSTRUTION(SIZE300MMX200MM) - 4 Nos. TW |
| 156 | Resistivity Survey of Tubewell Site |
| 157 | Transportation of rig machine erection, dismantling and associated T&P Complete in all respect including required all material , labour etc. |
| 158 | DRILLINGOFTUBEWELLBORE |
| 159 | Drilling of 625 mm. dia bore from G.Į. to 70 M. BGĮ (70x4) |
| 160 | Drilling of 500 mm. dia bore from 70 BGĮ to 100 M. BGĮ (30x4) |
| 161 | Drilling of 500 mm. dia bore from 100 BGĮ to 125 M. BGĮ (25x4) |
| 162 | Įogging of bore hole by electirc logger |
| 163 | TUBEWELLASSEMBLY-MSERWTubewellassemblywithall required parts like plain pipe, slotted pipe, MS rings, well cap, bail plugclamp,reducer,centralguide,supportstructureetc.as required and as per typed design complete in all respect. |
| 164 | 300 mm. dia 7.1 mm thick MSERW Plain Pipe with MS ring & reducer (62x4) |
| 165 | 200 mm.dia 7.1 mm thick M.S. Plain pipe & Slotted pipe with MS ring (50x4) |
| 166 | LoweringofTubewellassemblydulyweldedincludingwelding electrode |
| 167 | 300 mm. dia 7.1mm thick MSERW Plain / Slotted Pipe (62x4) |
| 168 | 200 mm. dia Plain/Slotted Pipe 63 M. BGĮto 100 M. BGĮ (38x4) |
| 169 | 200 mm. dia Plain/Slotted Pipe 101 M. BGĮto 112 M. BGĮ (12x4) |
| 170 | Supply & Shruoding of Įal Kuan Pea Gravel 1.6 to 4.8 mm. size for Tubewell (36x4) |
| 171 | DEVELOPMENTOFTUBEWELL |
| 172 | Transportation, Erection, Dismantling of 250 P.S.I. Compressor. |
| 173 | Charges for Development by 250 P.S.I. Compressor per hour. (60x4) |
| 174 | Transportation, Erection, Dismantling of 2 Cusec O.P. Unit and yeild Test. |
| 175 | Charges for Development by 2 Cusec O.P. Unitper hour. (80x4) |
| 176 | ChemicalandBacteriological testofwatersampleform departmentel / NABĮ approved lab. |
| 177 | CLEARWATERSUBMERSIBLEPUMPINGPLANTFORTUBEWELLSTOOHTZONE-1 |
| 178 | MECHANICAL&ELECTRICALWORKS |
| 179 | Supply,installation,testingandcommissioningofClearwater submersiblepump(IS9236)completewithelectricmotor(IS8034) capable to operate on 380/420 volts 3 phase 50 c/s A.C. Capable for giving 800LPM,75MtrHead,25HPforReboreTubewell . |
| 180 | Supply,installation,testingandcommissioningofClearwater submersiblepump(IS9236)completewithelectricmotor(IS8034) capable to operate on 380/420 volts 3 phase 50 c/s A.C. Capable for giving 600LPM,75MtrHead,20HPforExsistingTubewell. |
| 181 | Supply,installation,testing andcommissioningof Main Piping & Valves with 24Mtr. Column pipe, power wiring, earthing, painting, wiring of pump house(Internal&External) completeinallrespectwithallrequired material, T&P labour 100 mm Dia. sizefor ReboreTubewell .. |
| 182 | Supply,installation,testing andcommissioningof Main Piping & Valves with 24Mtr. Column pipe, power wiring, earthing, painting, wiring of pump house(Internal&External) completeinallrespectwithallrequired material, T&P labour 80 mm Dia. size for existing TW. |
| 183 | Supply of 3 Mtr Įong Heavy duty exta Coloum pipe 100 mm Dia. Size (8 No for each TW ) |
| 184 | Supply of 3 Mtr Įong Heavy duty exta Coloum pipe 80 mm Dia. Size (8 No for each TW ) |
| 185 | Supply of Motor operated actuators forsluice valve suitable for SCADA operationwithlimitswitches,autodeclutchformanualoperationin emergencyetcasperrelevantISsuitablefor100 mm dia size sluicevalve |
| 186 | Supply of Motor operated actuators forsluice valve suitable for SCADA operationwithlimitswitches,autodeclutchformanualoperationin emergency etcas per relevant IS suitable for 80mm diasizesluice valve |
| 187 | Supply of D.I./ D.F. Dismantling Joints is a variable length Double Flanged ShortPiececonstitutedbya flange/ SpigotTailpieceinsertedintothe other Tailpiece which allows the distance between the two flanges to be variedwithincertainlimitsthusprovidingavariabledistancepiece betweentwofixedflangeenddeviceslikePumpsandValves.The Dismantling Joint to be supplied complete with Sealing Rubber Gaskets of EPDM quality (IS:5382/1985 Type-4), Cast Iron Follower Glands and Mild Steel (Zinc Coated) Nut Bolts of 100mm diasize |
| 188 | Supply of D.I./ D.F. Dismantling Joints is a variable length Double Flanged ShortPiececonstitutedbya flange/ SpigotTailpieceinsertedintothe other Tailpiece which allows the distance between the two flanges to be variedwithincertainlimitsthusprovidingavariabledistancepiece betweentwofixedflangeenddeviceslikePumpsandValves.The Dismantling Joint to be supplied complete with Sealing Rubber Gaskets of EPDM quality (IS:5382/1985 Type-4), Cast Iron Follower Glands and Mild Steel (Zinc Coated) Nut Bolts of 80mmdia size |
| 189 | ExtraSubmersibleflatcoppercondutorcable3Cx6sq.mmPVC Sheathed double run (2Rx30m = 60 mtr for each TW) |
| 190 | Supply& laying of Į.T. XĮPE insulatedarmouredaluminiumconductor cable of 1.1 KV grade Material :- H4- Grade aluminium conductor of purity>99.6%&asperIS:1554P-I/IS:7098P-(I),conductorshallhave electrolytic aluminium confirming to IS 8130, IS 3975-1999.From transformer to Main ĮT panel of 3.5Cx 35Sq.mm. |
| 191 | Pumping Plant Motor inspection, B&Į and Challan fee |
| 192 | MOTORCONTROLCENTER(MCC)PANEL:-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 / IS:2147, considered Earth Bus-Bar-GI Strip compitable to SCADA operation with RS485 Port consisting of63 A, 50KA, TPN, MCCB microprocessor baseed(O/C,S/C) release - 1 No , Spreader Įinks & Extended ROH for - 1 No, 3 Phase Digital Multifunction Meter- 1 No, Digital Voltmeter 0-500V- 1 No, Digital Ammeter 0-400A-1Nos,CTFormeterResinCastCĮ-1400A/5A,15VA-3Nos,Phase indication light ĮED type 220V AC - 1 Set, Control MCB SP 6A ,10KA - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Įink - 1 No. |
| 193 | Supply of Air Cooled Digital soft starter suitable for the ĮT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ammeter,Voltmeter,indicatinglamp6Nos, ĮED ON/OFF type and Start/StoppushbuttonandInstrumentFuses,suitabletoSCADAoperation with RS485 Port of rating capacity 25HP/18.50KW |
| 194 | Supplyofmicroprocessorbasedthreephasesensingpowerfactor correctionrelaypanel,IEC/EN61000-6-(2&4)having3CTsensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted powerfactor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multiparameterlike KW, KVA, KVAR rating capacity of 20KVAR |
| 195 | Supply of Servo Controlled Automatic Voltage stabilizer suitable for out put voltage of 415 Volt +/-1%, 3 Ph, 50 Hz, with copper wound transformer (air/oilcooled).Thestabilizer shall functionsatisfactorily evenif incoming supply is unbalanced between phases within range of 10%. The stabilizer should be constructed in cubical box, with bi-directional wheels for easy handling, necessary monitors and user\"s controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and out put voltage, Auto/Manual selector switch, Raise/Įow push buttonsetc.Suitable capacity termination stripsandbusbars for incoming and out going cable should be provided. All three phases shall beindependentlymonitoredandcorrected(Operatingvoltage240V- 500V), 415 volt, 3Phase, 50Hz of following capacity |
| 196 | Servo Controlled Automatic Voltage stabilizer of 40KVA |
| 197 | Servo Controlled Automatic Voltage stabilizer of 30KVA |
| 198 | Supply of Change over or by pass switch rating capacity 63Amp |
| 199 | Supply of 2 Ton 4.5 mtr lift chain pully block |
| 200 | SupplyofAutophasereversalunit with inbuilttimedelay& enclosure (conforming to IEC:60947-1 & IEC:60947-b-1) 63Amprating |
| 201 | Supply of CE/UĮ Certified Surge protector for control panel |
| 202 | Providing & Fixing of IK07 IP-66 protected high power ĮED flood light system with Pressure diecast aluminium housing ĮM6/ ADC12 material 50 Watt Flood light |
| 203 | SupplyofAutomatic/SCADAoperatedelectromegnaticchlorination dozzer system |
| 204 | INSTRUMENTATIONWORK |
| 205 | Supply of CE/UĮ Certified pressure transmitter CE markd with following technical parametersand Interfacing with PĮC panel including mounting arrangement.Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4\" ĮEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 |
| 206 | SupplyofCE/UĮCertifiedFullBoreElectromagneticFlowMeterof approved make of following dia and specifications complete: Media: Water (Raw/Chlorinated) , Pressure :up to 1.0MPa, Process temp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI 316Į /Hastelloy C276/Tantalum,ĮiningMaterial:HardRubber/ Neoprene/Poly-urethane(PU) , Flange : SS /CS, Flange Standard & Rating:ANSI150,Coilhousing:SSAISI304/CarbonSteel/DieCast Aluminium,with anticorrosive paint & provide completelysealed(leak proof)constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5% M.V.- velocity 0.3 to 10 m/s, Transmitter/ signa convertorEnclosure: Die CastAluminium,Power Supply : 80-240V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type: ĮCD/ ĮED Display,Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/convertor, including Surge Arrester, cable,of following size. |
| 207 | Flow meter of 100mm diasizeat outlet |
| 208 | Flow meter of 80mmdia sizeat outlet |
| 209 | CE & UĮ Certified PĮC/ RTU in IP 54 enclosure suitable to communicate with intelligent GSM Based modem unit with CPU and Power Supply with analogandDigitalParameterandfeaturesasspecified tostoreand transmit data on GSM backbone, RTU designed with logic to tansfer data atmultiplestationsandalsocompatibleforsatellitecommunication alongwithcontrolpanelwithIP54Protection,Industrialgradeforall equipment and 24V and power supply for Tubewell & OHT |
| 210 | GSM/GPRS based wireless communication with 4G modem for RTU/PĮC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer, antenna made for pumping plantwith SIM andrecharge for 1 year |
| 211 | Supply of CE/UĮ cirtified of Radar type level transmitter CE marked with following technical parameters and Interfacing with PĮC panel including mounting arrangement with inbuild battery of 5 year life forOHTOutput-4-20 mA / HART Power supply - 24V DC ext. Display - 4\" ĮEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 |
| 212 | CE&UĮCertified7\" HMItouchscreensuitabletocommunicationwith PĮC/RTU for local display & control of process parameters |
| 213 | CE/UĮ Certified Intelligent energy meters |
| 214 | SupplyofElectricallyMotoroperatedactuatorwithbracketfor sluice valve suitable for SCADA operation with limit switches, auto de clutch for manual operation in emergency etcas per relevant IS suitable for 300 mmdia sizesluice valveat OHT outlet |
| 215 | Completecablingforinstrumentation/SCADAequipmentswithpower supply of panels form source for Tubewell & OHT |
| 216 | Security Survelliance IP Camera with all required accessories |
| 217 | Supply and Fixing of fire extinguisher of 5 Kg. capacity conforming to IS: 15683:2006 |
| 218 | Rubber mats for electrical purpose as per IS:5425-1969, plain/chequered (1mX2m) - 19mm thickness |
| 219 | Installation,testing and comissioning of pumpingplant & associated all equipmentsas per approveddrawing shall be done by bidder including electrical resistance rubber mats and painting of pumping plant & main piping-valves. |
| 220 | Testing of Pumping Plant & Control Panel & valves etc at Manufacturer Works |
| 221 | CLEARWATERSUBMERSIBLEPUMPINGPLANTFORTUBEWELLSTOOHTZONE-2 |
| 222 | Supply,installation,testingandcommissioningofClearwater submersiblepump(IS9236)completewithelectricmotor(IS8034) capable to operate on 380/420 volts 3 phase 50 c/s A.C. Capable for giving 800LPM,75MtrHead,25HPforRebore & New Tubewell . |
| 223 | Supply,installation,testing andcommissioningof Main Piping & Valves with 24Mtr. Column pipe, power wiring, earthing, painting, wiring of pump house(Internal&External) completeinallrespectwithallrequired material, T&P labour 100 mm Dia. size. |
| 224 | Supply of 3 Mtr Įong Heavy duty exta Coloum pipe 100 mm Dia. Size (8 No for each TW ) |
| 225 | Supply of Motor operated actuators forsluice valve suitable for SCADA operationwithlimitswitches,autodeclutchformanualoperationin emergencyetcasperrelevantISsuitablefor100 mm dia size sluice valve |
| 226 | Supply of D.I./ D.F. Dismantling Joints is a variable length Double Flanged ShortPiececonstitutedbya flange/ SpigotTailpieceinsertedintothe other Tailpiece which allows the distance between the two flanges to be variedwithincertainlimitsthusprovidingavariabledistancepiece betweentwofixedflangeenddeviceslikePumpsandValves.The Dismantling Joint to be supplied complete with Sealing Rubber Gaskets of EPDM quality (IS:5382/1985 Type-4), Cast Iron Follower Glands and Mild Steel (Zinc Coated) Nut Bolts of 100mm diasize |
| 227 | ExtraSubmersibleflatcoppercondutorcable3Cx6sq.mmPVC Sheathed double run (2Rx30m = 60 mtr for each TW) |
| 228 | Supply& laying of Į.T. XĮPE insulatedarmouredaluminiumconductor cable of 1.1 KV grade Material :- H4- Grade aluminium conductor of purity>99.6%&asperIS:1554P-I/IS:7098P-(I),conductorshallhave electrolytic aluminium confirming to IS 8130, IS 3975-1999.From transformer to Main ĮT panel of 3.5Cx 35Sq.mm. |
| 229 | Pumping Plant Motor inspection, B&Į and Challan fee |
| 230 | MOTORCONTROLCENTER(MCC)PANEL:-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 / IS:2147, considered Earth Bus-Bar-GI Strip compitable to SCADA operation with RS485 Port consisting of63 A, 50KA, TPN, MCCB microprocessor baseed(O/C,S/C) release - 1 No , Spreader Įinks & Extended ROH for - 1 No, 3 Phase Digital Multifunction Meter- 1 No, Digital Voltmeter 0-500V- 1 No, Digital Ammeter 0-400A-1Nos,CTFormeterResinCastCĮ-1400A/5A,15VA-3Nos,Phase indication light ĮED type 220V AC - 1 Set, Control MCB SP 6A ,10KA - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Įink - 1 No. |
| 231 | Supply of Air Cooled Digital soft starter suitable for the ĮT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ammeter,Voltmeter,indicatinglamp6Nos, ĮED ON/OFF type and Start/StoppushbuttonandInstrumentFuses,suitabletoSCADAoperation with RS485 Port of rating capacity 25HP/18.50KW |
| 232 | Supplyofmicroprocessorbasedthreephasesensingpowerfactor correctionrelaypanel,IEC/EN61000-6-(2&4)having3CTsensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted powerfactor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multiparameterlike KW, KVA, KVAR rating capacity of 20KVAR |
| 233 | Supply of Servo Controlled Automatic Voltage stabilizer suitable for out put voltage of 415 Volt +/-1%, 3 Ph, 50 Hz, with copper wound transformer (air/oilcooled).Thestabilizer shall functionsatisfactorily evenif incoming supply is unbalanced between phases within range of 10%. The stabilizer should be constructed in cubical box, with bi-directional wheels for easy handling, necessary monitors and user\"s controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and out put voltage, Auto/Manual selector switch, Raise/Įow push buttonsetc.Suitable capacity termination stripsandbusbars for incoming and out going cable should be provided. All three phases shall beindependentlymonitoredandcorrected(Operatingvoltage240V- 500V), 415 volt, 3Phase, 50Hz of40KVA capacity |
| 234 | Supply of Change over or by pass switch rating capacity 63Amp |
| 235 | Supply of 2 Ton 4.5 mtr lift chain pully block |
| 236 | SupplyofAutophasereversalunit with inbuilttimedelay& enclosure (conforming to IEC:60947-1 & IEC:60947-b-1) 100Amprating |
| 237 | Supply of CE/UĮ Certified Surge protector for control panel |
| 238 | Providing & Fixing of IK07 IP-66 protected high power ĮED flood light system with Pressure diecast aluminium housing ĮM6/ ADC12 material 50 Watt Flood light |
| 239 | SupplyofAutomatic/SCADAoperatedelectromegnaticchlorination dozzer system |
| 240 | INSTRUMENTATIONWORK |
| 241 | Supply of CE/UĮ Certified pressure transmitter CE markd with following technical parametersand Interfacing with PĮC panel including mounting arrangement.Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4\" ĮEDAccuracy - +/- 0.1 % of full scale or betterEnclosure- IP 68 |
| 242 | SupplyofCE/UĮCertifiedFullBoreElectromagneticFlowMeterof approved make of following dia and specifications complete: Media: Water (Raw/Chlorinated) , Pressure :up to 1.0MPa, Process temp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI 316Į /Hastelloy C276/Tantalum,ĮiningMaterial:HardRubber/ Neoprene/Poly-urethane(PU) , Flange : SS /CS, Flange Standard & Rating:ANSI150,Coilhousing:SSAISI304/CarbonSteel/DieCast Aluminium,with anticorrosive paint & provide completelysealed(leak proof)constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5% M.V.- velocity 0.3 to 10 m/s, Transmitter/ signa convertorEnclosure: Die CastAluminium,Power Supply : 80-240V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type: ĮCD/ ĮED Display,Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable, of100mmdia size at delivery header |
| 243 | CE & UĮ Certified PĮC/ RTU in IP 54 enclosure suitable to communicate with intelligent GSM Based modem unit with CPU and Power Supply with analogandDigitalParameterandfeaturesasspecified tostoreand transmit data on GSM backbone, RTU designed with logic to tansfer data atmultiplestationsandalsocompatibleforsatellitecommunication alongwithcontrolpanelwithIP54Protection,Industrialgradeforall equipment and 24V and power supply for Tubewell & OHT |
| 244 | GSM/GPRS based wireless communication with 4G modem for RTU/PĮC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer, antenna made for pumping plantwith SIM andrecharge for 1 year |
| 245 | Supply of CE/UĮ cirtified of Radar type level transmitter CE marked with following technical parameters and Interfacing with PĮC panel including mounting arrangement with inbuild battery of 5 year life forOHTOutput-4-20 mA / HART Power supply - 24V DC ext. Display - 4\" ĮEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 |
| 246 | CE&UĮCertified7\" HMItouchscreensuitabletocommunicationwith PĮC/RTU for local display & control of process parameters |
| 247 | CE/UĮ Certified Intelligent energy meters |
| 248 | SupplyofElectricallyMotoroperatedactuatorwithbracketfor sluice valve suitable for SCADA operation with limit switches, auto de clutch for manual operation in emergency etcas per relevant IS suitable for 250 mmdia sizesluice valveat OHT outlet |
| 249 | Completecablingforinstrumentation/SCADAequipmentswithpower supply of panels form source for Tubewell & OHT |
| 250 | Security Survelliance IP Camera with all required accessories |
| 251 | Supply and Fixing of fire extinguisher of 5 Kg. capacity conforming to IS:15683:2006 |
| 252 | Rubber mats for electrical purpose as per IS:5425-1969, plain/chequered (1mX2m) - 19mm thickness |
| 253 | Toolset:-Spenners -2Nos, AdjustableWrinchset-2Nos,sizewrinchesof different sizes - 1 Set, Gigital Tong tester - 1 Nos, Digital Clamp meter - 1 No, megger 5Mva- 1 No, Hydraulic crimping tool 500 Sq mm size - 1 No, Sand PPM measuring kit - 1 No, Digital Screw Gauge 40mm size - 1 No, Inner & Outer pipe gauge set 500mm size - 1 Set, Filler gauges - 1 Set, Electronic battery operated water level / depth gauge with meter marking upto 400 mtr depth - 1 No |
| 254 | Installation,testing and comissioning of pumpingplant & associated all equipmentsas per approveddrawing shall be done by bidder including electrical resistance rubber mats and painting of pumping plant & main piping-valves. |
| 255 | Testing of Pumping Plant & Control Panel & valves etc at Manufacturer Works |
| 256 | MASTERCONTROLSTATION(MCS) |
| 257 | CE/UĮ&BISCertifiedindustrialgradeĮEDMONITOR withlatest configuration as per specification 65\" |
| 258 | Video call media player of same OEM |
| 259 | Core i7 10th gen Desktop with 8 gb ram and 1 TB SSD |
| 260 | CE/UĮ Certified 3 KVA UPS with Batteries required for mentioned work wih 01 hrs backup |
| 261 | Full Development version of TAGS SCADA software with costomization ofsoftwareforMCSforunlimiteddigitalandanalogInput/output features as per requirements |
| 262 | CE/UĮ certified master control room PĮC with redundant CPU & power supply at MCS in IP-54 enclosure as per site requirement and specification required to complete in all respect |
| 263 | CE/UĮ certified Field gateway agent for transfering data for MCS/control room |
| 264 | GSM/GPRSbased wireless/Broadband/equivelent communication system for PĮC Capable to transfer and receive data & gather data from remotesitestocontrolstationsallaccessoriesincludedwithsignal enhancer, antenna along with running expences till 1 year |
| 265 | CE/UĮ certified Firewall for network protection |
| 266 | Surge protector for Ethernet communication protection |
| 267 | CE/UĮ Certified industrial grade Ethernet switch |
| 268 | Mobileappfacilitysystemarchitecture(industriesinternetbased& viewed through mobile apps for increasedblocal & remote visibility) |
| 269 | Canon/HP or equivalent Įaser Printer 1018 or equivalent. |
| 270 | Hp or equivalent multifunctioning Įaser Printer with scanner |
| 271 | BEE : 5 Star rating 1.5 Ton capacity air conditioner with voltage satbilizer |
| 272 | Office furniture ( office table - 2 No, revolving chair- 2No, Office chair-3 No, Godrej almirah - 1No) |
| 273 | Security Survelliance IP Camera with recorder |
| 274 | Supply and Fixing of fire extinguisher of 5 Kg. capacity conforming to IS: 15683:2006 |
| 275 | Installation, Commissioning and testing of all above equipments for MCSwith all power cables |
| 276 | TRAIL&RUNFOR3MONTHSWITHOUTELECTRICITY |