Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift up to 1.5 m, as directed by Engineer-in-Charge: |
| 2 | All kinds of soil |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. |
| 4 | All kinds of soil |
| 5 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50 m and lift up to 1.5m, as directed by Engineer-in-Charge. |
| 6 | Ordinary rock |
| 7 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 8 | All kinds of soil. |
| 9 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m. |
| 10 | Ordinary rock |
| 11 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : |
| 12 | All kinds of soil |
| 13 | Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 14 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 15 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 16 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 17 | 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 18 | 1:5:10 (1 cement : 5 coarse sand(zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 19 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, excluding the cost of centering, shuttering and finishing : |
| 20 | 1:5:10 (1 cement : 5 coarse sand(zone-III) : 10 graded brick aggregate 40 mm nominal size). |
| 21 | Providing and laying in position plum concrete with hard stone boulders in retaining walls etc up to all height and level, in required size and shape etc. with cement concrete of mix 1:3:6 (1 Cement : 3 Coarse sand : 6 Graded stone aggregate 40 mm nominal size) using 40 % plum / hard stone boulders of size 150 mm to 300 mm, excluding cost centring and shuttering all complete as per the direction of Engineer-in-charge. |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form work for : |
| 23 | Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.. |
| 24 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation leveling and dressing and finishing the top smooth. |
| 25 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 26 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 27 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 28 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources) |
| 29 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). |
| 30 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 31 | Foundations, footings, bases of columns, etc. for mass concrete |
| 32 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 33 | Suspended floors, roofs, landings, balconies and access platform |
| 34 | Shelves (Cast in situ) |
| 35 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 36 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 37 | Stairs, (excluding landings) except spiral-staircases |
| 38 | Edges of slabs and breaks in floors and walls |
| 39 | Under 20 cm wide |
| 40 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto alllevel. |
| 41 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 42 | Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand). |
| 43 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 44 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 45 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 46 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 47 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 48 | Supplying & back filling with well graded stone boulders of size 150 mm to 300 mm behind retaining wall complete as per the directions of the Engineer-in-charge. (Note :- 30% deductions in measurements shall be made for voids). |
| 49 | Providing and fixing 110mm dia Rigid PVC pipe (working pressure 4 kg / sqcm) conforming to IS : 13592 type A in retaining walls for use as weep holes, laid to required slope complete as per the directions of the Engineer-in-charge. |
| 50 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
| 51 | Granite stone slab colour black, Cherry/Ruby red |
| 52 | Area of slab over 0.50 sqm |
| 53 | Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete |
| 54 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinalpartitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finishedsmooth. |
| 55 | Granite Stone of approved shade |
| 56 | Providing and fixing Ist quality ceramic rectified glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 57 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 58 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 59 | Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). |
| 60 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : |
| 61 | 25 mm dia (heavy type) |
| 62 | Providing M.S. Piano hinges ISI marked IS : 3818 finished with nickel plating and fixing with necessary screws etc., complete. |
| 63 | Overall width 35 mm. |
| 64 | Providing and fixing bright /matt finished Stainless Steel sliding door bolts of approved quality & make with necessary screws etc all complete as per direction of Engineer-in-Charge. |
| 65 | 300x16 mm |
| 66 | 250x16 mm |
| 67 | Providing and fixing bright /matt finished Stainless Steel tower boltof approved quality & make with necessary screws etc all complete as per direction of Engineer-in-Charge.. |
| 68 | 250x10 mm |
| 69 | Providing and fixing bright /matt finished Stainless Steelhandles of approved quality & make with necessary screws etc all completeas per direction of Engineer-in-Charge.. |
| 70 | 125 mm |
| 71 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 72 | Twin rubber stopper |
| 73 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 74 | 150x10 mm |
| 75 | Providing and fixing 2nd class teak wood lipping/ moulded beading or taj beading of size 18X5 mm fixed with wooden adhesive of approved quality and screws/ nails on the edges of the Pre-laminated particle board as per direction of Engineer-in-charge. |
| 76 | Providing and fixing powder coated telescopic drawer channels 300 mm long with necessary screws etc. complete as per directions of Engineer-in-charge. |
| 77 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 78 | Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. |
| 79 | Size 50 mm |
| 80 | Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. |
| 81 | Triple strip vertical type |
| 82 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady] the frame. |
| 83 | Providing and fixing to existing door frames. |
| 84 | 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. |
| 85 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. |
| 86 | 1.0 mm thick. |
| 87 | Providing & Fixinglaminated sheet of in white / ivory shade of Century/Greenply/Merino make, inside of cupboard etc. with adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. |
| 88 | 0.8 mm thick. |
| 89 | Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws: |
| 90 | 35 mm thick shutters. |
| 91 | Second class teak wood |
| 92 | Providing and fixing MS powder coated set of five pegs (Hooks) of approved quality with MS screws all complete as per direction of the Engineer-in-charge . |
| 93 | P/F PVC rubber Silencer on the rear side of door shutter to avoid collision between wall and door shutter as per directions of Engineer in Charge. |
| 94 | Providing and fixing BWP Ply board conforming to IS: 710 of of Merriono/ Greenply/ Century/Archid/Kitply , bonded with phenolformaldehyde synthetic resin in cupboards, shelves, shutters with necessary screws, nails and adhesive etc. all complete as per the direction of Engineer-in-charge |
| 95 | 18mm thick |
| 96 | Providing and fixing 6mm thick BWP grade commercial ply of Merriono/ Greenply/Century/ Archid/ Kitply , bonded with phenolformaldehyde synthetic resin in backing ofcupboards, shelves, shutters with necessary screws, nails and adhesive etc. all complete as per the direction of Engineer-in-charge |
| 97 | 6mm thick |
| 98 | Providing and fixing glazing in Aluminium windows, all complete with aluminium beading as per manufacturer\"s specification and direction of of Engineer-in-charge. ( Note :- aluminium beading to be paid in basic frame item).(Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). |
| 99 | 5 mm thick toughened energy efficient reflectiveglass . |
| 100 | Providing and fixing Touch Lock handle made of zinc alloyed (white powder coated) for Aluminium casement window with necessary screws etc. complete. |
| 101 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 102 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: |
| 103 | Profile B |
| 104 | Fixing with adjustable lugs with split end tail to each jamb. |
| 105 | Profile C |
| 106 | Fixing with adjustable lugs with split end tail to each jamb. |
| 107 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 108 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 109 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 110 | 40 mm thick with 20 mm nominal size stone aggregate |
| 111 | Providing and laying rectified Glazed Ceramic floor tiles of size 450x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 112 | Providing and laying full body homogeneous and unglazed vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 113 | Size of Tile 600x600 mm |
| 114 | Providing and laying full body Vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make in all colours & shade in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), including grouting the joint with white cement &matching pigments etc. complete. |
| 115 | Size of Tile 600x600 mm |
| 116 | Grouting the joints of flooring tiles having joints of 5 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade(0.10 kg of hardener and 0.20 kg of resin per kg), including filling/grouting and finishing complete as per direction of Engineer-in-charge. |
| 117 | Size of Tile 600x600 mm |
| 118 | Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles |
| 119 | Providing and layingGVT(Glazed Vitrified Tiles)of approvedin smooth finish Vitrified tiles in different sizes (Minimum thickness 12 mm ) with water absorption less than 0.08 % and conforming to I.S. 15622, in all colours & shade in wall lining, in skirting, risers of steps and dados& floor over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including using PVC spacer 2 to 3 mm thick and after removing the spacers,the joints shall be filled using epoxy grout mix of 0.7 kg of organic coated filler of desired shade , 0.1 Kg of hardner and 0.2 kg of resin per kg of grout and finishing all complete as per direction of E-In-Charge. |
| 120 | Size of Tile1200x600 mm |
| 121 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 122 | Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent |
| 123 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, |
| 124 | (i)Single socketed pipes. |
| 125 | 110 mm diameter |
| 126 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. |
| 127 | Bend 87.5° |
| 128 | 110 mm bend |
| 129 | Shoe (Plain) |
| 130 | 110 mm Shoe |
| 131 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hardwood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 132 | 110 mm |
| 133 | Providing and fixing precoated profiled colour coated Galvalume profile sheets of TATA Durashine/ JINDAL Coloron / CRILL(size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.5 mm (min. total coated thickness ) tensile strength 550 mpa steel grade,composition -55% Aluminium, 43.4% ZInc & 1.6% Silicon ,strength As per IS 1397 - 1993, base metal high tensile steel. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 134 | Providing and fixing precoatedplain Galvalume profile sheets of TATA Durashine /JINDAL Coloron /CRILLas approved by Engineer-in-charge 0.470 mm (min. total coated thickness ) tensile strength 550 mpa steel grade,composition -55% Aluminium, 43.4% ZInc & 1.6% Silicon ,strength as per IS 1397 - 1993, base metal high tensile steel sheet600 mm wide plain precoated sheet for ridges / valleys / flashings / gutters or 200 mm to 600 mm wide E-Board / E Board bottom with nominal 40 mum zinc coated or nominal 25 mum zinc-tin alloy coated, hexhead, self-drilling screws as per AS 3566-2002 class 3 fasteners woth EPDM / Cyclonic washer all complete as per the direction of the Engineer -in-charge. |
| 135 | 12 mm cement plaster of mix : |
| 136 | 1:6 (1 cement: 6 coarse sand) |
| 137 | 15 mm cement plaster on rough side of single or half brick wall of mix : |
| 138 | 1:6 (1 cement: 6 coarse sand) |
| 139 | 15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall. |
| 140 | Neat cement punning |
| 141 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification. |
| 142 | Two or more coats on new work. |
| 143 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 144 | Water thinnable cement primer. |
| 145 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 146 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). |
| 147 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 148 | Two or more coats on new work. |
| 149 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 150 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 151 | French spirit polishing : |
| 152 | Two or more coats on new works including a coat of wood filler. |
| 153 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 154 | Providing and fixing 22 gauge chiken wire mesh in required size and shape 150 mm wide and fixed with Bombay nails on vertical and horizontal junctions of RCC and AAC block masonary i/c scaffholding, all leads and lifts etc. Before plastering of surface all complete as per direction of E-In-Charge. |
| 155 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re- olling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 156 | Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer\"s specifications & direction of Engineer in-Charge. |
| 157 | 80mm thick Cement concrete paver block of M-40 grade with approved colour, design & pattern. |
| 158 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required : |
| 159 | W.C. pan with ISI marked white solid plastic seat and lid |
| 160 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : |
| 161 | Single half stall urinal with 5 litre P.V.C. automatic flushing cistern |
| 162 | Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern |
| 163 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 164 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 165 | White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 166 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 167 | Kitchen sink with drain board |
| 168 | 510x1040 mm bowl depth 250 mm. |
| 169 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 170 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 171 | Flexible pipe |
| 172 | 32 mm dia |
| 173 | 40 mm dia |
| 174 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 175 | Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 176 | Providing and fixing toilet paper holder : |
| 177 | C.P. brass |
| 178 | Providing and fixing soil, waste and vent pipes : |
| 179 | 100 mm dia. |
| 180 | Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989. |
| 181 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and includingcement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : |
| 182 | For 100 mm dia. Pipe |
| 183 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. |
| 184 | 100 mm dia |
| 185 | Sand cast iron S&S as per IS - 3989 |
| 186 | Providing and fixing plain bend of required degree. |
| 187 | 100 mm dia |
| 188 | Sand cast iron S&S as per IS : 3989 |
| 189 | Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. |
| 190 | 100x100x100 mm |
| 191 | Sand cast iron S&S as per IS - 3989 |
| 192 | Providing and fixing single equal plain junction of required degree : |
| 193 | 100x100x100 mm |
| 194 | Sand cast iron S&S as per IS - 3989 |
| 195 | Providing and fixing terminal guard: |
| 196 | 100 mm |
| 197 | Sand cast iron S&S as per IS - 3989 |
| 198 | Providing and fixing collar: |
| 199 | 100 mm |
| 200 | Sand cast iron S&S as per IS - 3989 |
| 201 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter: |
| 202 | 100 mm |
| 203 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : |
| 204 | 100 mm inlet and 100 mm outlet |
| 205 | Sand cast iron S&S as per IS: 3989. |
| 206 | Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : |
| 207 | 100 mm diameter pipe |
| 208 | Extra for providing and fixing 100 mm Dia stainless steel grating with frame (with or without hole) instead of screwed down or hinged SCI grating. |
| 209 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. : Internal work – Exposed on wall. |
| 210 | 15 mm dia. nominal bore |
| 211 | 20 mm dia. nominal bore |
| 212 | 25 mm dia. nominal bore |
| 213 | 32 mm dia. nominal bore |
| 214 | 40 mm dia. nominal bore |
| 215 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anticorrosive bitumastic paint, cutting chases and making good the wall: |
| 216 | 15 mm dia. nominal bore |
| 217 | 20 mm dia. nominal bore |
| 218 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. : External work |
| 219 | 32 mm dia. nominal bore |
| 220 | 40 mm dia. nominal bore |
| 221 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
| 222 | 25 to 40 mm nominal bore |
| 223 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 224 | 25 mm nominal bore |
| 225 | 20 mm nominal bore |
| 226 | 32 mm nominal bore. |
| 227 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 228 | 20 mm nominal bore |
| 229 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 230 | 45 cm length |
| 231 | 15 mm nominal bore |
| 232 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : |
| 233 | 100 mm diameter |
| 234 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : |
| 235 | 15 mm diameter pipe. |
| 236 | 20 mm diameter pipe. |
| 237 | 25 mm diameter pipe. |
| 238 | 32 mm diameter pipe. |
| 239 | 40 mm diameter pipe. |
| 240 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : |
| 241 | 32 mm diameter pipe |
| 242 | Providing and filling sand of grading zone V or coarser grade all- round the G.I. pipes in external work. |
| 243 | 32 mm diameter pipe |
| 244 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) |
| 245 | 15 mm nominal bore |
| 246 | 20 mm nominal bore |
| 247 | 25 mm nominal bore |
| 248 | 32 mm nominal |
| 249 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 250 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931: |
| 251 | 15 mm nominal bore. |
| 252 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 253 | 15 mm nominal bore. |
| 254 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 : |
| 255 | 15mm nominal bore |
| 256 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 257 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : |
| 258 | 150 mm diameter |
| 259 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : |
| 260 | 150 mm diameter S.W. pipe |
| 261 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: |
| 262 | 100x100 mm size P type |
| 263 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 264 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : |
| 265 | 150 mm dia. R.C.C. pipe |
| 266 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : |
| 267 | Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : |
| 268 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 269 | Extra for depth for manholes |
| 270 | Size 90x80 cm |
| 271 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 272 | Replacement of M.S. foot rests in manholes including dismantling concrete blocks and fixing with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) : |
| 273 | With 20x20 mm square bar |
| 274 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality |
| 275 | L D - 2.5 |
| 276 | Rectangular shape 600x450 mm internal dimensions |
| 277 | Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with pre-cast R.C.C. vertical grating complete as per standard design : |
| 278 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 279 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
| 280 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 281 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 282 | For fixed portion |
| 283 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 284 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). |
| 285 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 286 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. |
| 287 | (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). |
| 288 | Providing and fixing GI Spouts in depressed portions,40mm dia and 60Cm long in Cement Mortar 1:4 (1 Cement: 4 Fine Sand) i/c making arrangement for smooth & efficient functioning of the spout as per the direction of the Engineer-in-charge. |
| 289 | ELECTRICAL COMPONENTSH: WIRING Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 290 | Group A |
| 291 | Group C |
| 292 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 293 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
| 294 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
| 295 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 296 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 297 | 4 X 1.5 sq. mm + 2 X 1.5 sq. mm earth wire |
| 298 | 6 X 1.5 sq. mm + 3 X 1.5 sq. mm earth wire |
| 299 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 300 | 4 X 10 sq. mm + 2 X 6sq. mm earth wire |
| 301 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 302 | 20mm |
| 303 | 25mm |
| 304 | 32 mm |
| 305 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. |
| 306 | 1x1.5 sq. mm |
| 307 | 2x1.5 sq. mm |
| 308 | 3x1.5 sq. mm |
| 309 | 4x1.5 sq. mm |
| 310 | 5x1.5 sq. mm |
| 311 | 6x1.5 sq. mm |
| 312 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 313 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 314 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 315 | 5/6 amps switch |
| 316 | 15/16 amps switch |
| 317 | 3 pin 5/6 amp socket outlet |
| 318 | 6 pin 15/16 amp socket outlet |
| 319 | RJ-45 Jack with Cat 6 |
| 320 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. |
| 321 | 1 or 2 Module (75mmX75mm) |
| 322 | 4 Module (125mmX75mm) |
| 323 | 8 Module (125mmX125mm) |
| 324 | 12 Module (200mmX150mm) |
| 325 | S/Fixing hexagonal fan box of size 150 mm dia made outof 16 SWG MS sheet including 12mm dia MS rod in the U shape with its vertical legs bent horizontally at thetop at least 19 cm on either side and bound to the top reinforcement of the roof at the time of casting i/c S/F 3 mm thick phenolic laminated sheet at the bottom complete as reqd. |
| 326 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 327 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 328 | 1 run of cable |
| 329 | 2 run of cable |
| 330 | SH: DISTRIBUTION SYSTEMSupplying and fixing following way, horizontal type SPN / TPN, sheet steel, MCB distribution board, 240/ 415 volts, on surface/ recess, complete with metal door, tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) |
| 331 | 12 Way SPNDouble Door |
| 332 | 4 Way TPN (8+12) Double Door |
| 333 | Supplying and fixing following rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 334 | 5 amps to 32 amps, 240 volts Single pole. |
| 335 | Double Pole |
| 336 | 63 amps, 415 volts Four pole. |
| 337 | S/F Following rating MCB power protected unit suitable for operation on 230V single phase AC supply complete with all accessories i/c making interconnection etc as required. |
| 338 | 16A |
| 339 | Supplying and fixing 63 Amps., four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 340 | Supplying and fixing Adaptor Box(s) fabricated out of 16 SWG M.S. sheet complete with cutting, welding, painting, sign writing etc. all as required. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail