Shipping Boards / Undertakings / PSU Closing in 0 days TDR #44763489

Tender For Annual Repair And Maintenance For Fire Fighting Lines Pertaining To Tower Monitor Line, Fire Hydrant Lines From Oph To Bd I, From Nph To Bd I And Also From Nph To Ms. Iocl, Foreshore Terminal At Oil Dock For Period Of Two Years In Chennai Port

Issued by Boards / Undertakings / PSU · chennai, Tamil Nadu
Tender Value
40.82 Lakhs
Estimated cost
Bid Submission
02 Sep 2024
0 days left
EMD
81656
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
chennai → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Annual Repair And Maintenance For Fire Fighting Lines Pertaining To Tower Monitor Line, Fire Hydrant Lines From Oph To Bd I, From Nph To Bd I And Also From Nph To Ms. Iocl, Foreshore Terminal At Oil Dock For Period Of Two Years In Chennai Port Authority

BOQ

Name of Work : e TENDER FOR ANNUAL MAINTENANCE CONTRACT (AMC) FOR FIRE FIGHTING LINES PERTAINING 16\" DIA TOWER MONITOR LINE, 14\" DIA FIRE HYDRANT LINES FROM OLD PUMP HOUSE TO BD - I, FROM NEW PUMP HOUSE TO BD - I AND ALSO FROM NEW PUMP HOUSE TO M/s. IOCL FORESHORE TERMINAL AT OIL DOCK FOR A PERIOD OF 2 YEARS AT OIL DOCK IN CHENNAI PORT AUTHORITY UNDER TWO COVER SYSTEM.
Sl. No. Item Description
1Supply of fine river sand for cement coatings to a uniform thickness of 15mm (cement and sand ratio 1:3) of various sizes of pipelines, Bends, T-Connections and reducers, etc., as detailed in Schedule - A.Note: Supply may be required for need basis at the time of fabrication.
2Supply of Cement for cement coatings to a uniform thickness of 15mm (cement and sand ratio 1:3) of various sizes of pipelines, Bends, T-conections and reducers, etc., as detailed in Schedule - A.Note: Supply may be required for need basis at the time of fabrication.
3Supply of ERW pipe of 250mm NB X 6.3mm wall thickness as per IS 3589 FE 410 of random length 4 to 7 Meters as detailed in Schedule - A. Note: Manufacturer test certificate and Guarantee certificate should accompany with the supply.
4Supply of ERW pipe of 200mm NB X 6.3mm wall thickness as per IS 3589 FE 410 of random length 4 to 7 Meters as detailed in Schedule - A. Note: Manufacturer test certificate and Guarantee certificate should accompany with the supply.
5Supply of ERW pipe of 150mm NB X 4.5mm wall thickness as per IS 3589 FE 410 of random length 4 to 7 Meters as detailed in Schedule - A. Note: Manufacturer test certificate and Guarantee certificate should accompany with the supply.
6Supply of ERW pipe of 100mm NB X 5.4mm wall thickness as per IS 1239 of random length 4 to 7 Meters as detailed in Schedule - A.Note: Manufacturer test certificate and Guarantee certificate should accompany with the supply.
7Supply of ERW pipe of 50mm NB X 4.5mm wall thickness as per IS 1239of random length 4 to 7 Meters as detailed in Schedule - A. Note: Manufacturer test certificate and Guarantee certificate should accompany with the supply.
8Supply of different sizes of cast steel 90 degree Bend as mentioned below as detailed in Schedule - A.16\" Ø 90 deg Bend
914\" Ø 90 deg Bend
1010\" Ø 90 deg Bend
118\" Ø 90 deg Bend
126\" Ø 90 deg Bend
134\" Ø 90 deg Bend
14Supply of HT Bolts & Nuts as follows required for the above works as detailed in Schedule - A.M24 X 110 mm long
15M22 X 110 mm long
16M20 X 100 mm long
17M20 X 90 mm long
18M18 X 90 mm long
19M16 X 75 mm long
20Supply of metallic gaskets as follows required for the above works as detailed in Schedule - A.16\" Ø Metallic Gasket, 3 mm thick.
2114\" Ø Metallic Gasket, 3 mm thick.
2212\" Ø Metallic Gasket, 3 mm thick.
2310\" Ø Metallic Gasket, 3 mm thick.
248\" Ø Metallic Gasket, 3 mm thick.
256\" Ø Metallic Gasket, 3 mm thick.
264\" Ø Metallic Gasket, 3 mm thick.
27Supply of M.S. Flanges (Class 150) of the following sizes as detailed in Schedule - A.16\" Ø M.S. Flange.
2814\" Ø M.S. Flange.
2912\" Ø M.S. Flange.
3010\" Ø M.S. Flange.
318\" Ø M.S. Flange.
326\" Ø M.S. Flange.
334\" Ø M.S. Flange.
34Supply of cast steel gate valve,raising spindle, Bolted bonnet Class 150 Face to Face dimension as per B 16.10, Flange drilling as per ANSI B 16.5, RF serrated, Design standard API600/ANSI 16.34. as detailed in Schedule - A. Note: Manufacturer test certufucate and Guarantee certificate should accompany with the supply. Size : 8\"
35Size : 6\"
36Size : 4\"
37Size : 2\"
38Labour Charges for replacing of punctured/weakened portions of the fire fighting pipelines including cutting, fabrication, cement coating, laying, aligning, welding in the existing maint line as per detailed in Scheduled - A.Note : Necessary steel pipes of 16\"/14\" will be supplied by ChPA. 16\" Ø Pipeline.
3914\" Ø Pipeline.
4010\" Ø Pipeline.
418\" Ø Pipeline.
426\" Ø Pipeline. (without cement coating)
434\" Ø Pipeline. (without cement coating)
442\" Ø Pipeline. (without cement coating) along with all required flanges, gaskets, pipe fittings and fasteners, etc.,
45Labour Charges for cement coating and laying, aligning, welding in the existing main line of the following firm supply items as detailed in Schedule - A.16\" Ø 90 deg Bend.
4614\" Ø 90 deg Bend.
4710\" Ø 90 deg Bend.
488\" Ø 90 deg Bend.
496\" Ø 90 deg Bend. (without cement coating)
504\" Ø 90 deg Bend. (without cement coating)
51Labour Charges for fabrication, cement coating, laying, aligning and welding of the following items from the ChPA supplied pipes as detailed in Schedule - A. 16\" Ø \"T\" Connection
5214\" Ø \"T\" Connection
5310\" Ø \"T\" Connection
5416\"/14\"Ø Reducer
5514\"/10\" Ø Reducer
5614\"/8\" Ø Reducer
578\"/6\" Ø Reducer
58Labour Charges for replacing of gate valves in fire fighting lines including gaskets, bolts & nuts, etc.,as per detailed in Schedule - A.Note: The necessary 12\" Ø gate valves only will be supplied by ChPA. 12\" ØGate valve.
598\" ØGate valve.
606\" ØGate valve.
614\" ØGate valve.
62Labour Charges for reconditioning of gate valves and NRVs in fire fighting lines including gaskets, bolts & nuts, etc., as per detailed in Schedule - A. 16\"/14\" Øgate valve.
638\" Øgate valve.
6412\"/10\" ØNRV.
65Labour Charges for cutting and welding of doubler plates/patch plates on punctured/weakened portions as detailed in Schedule - A.Note: Necessary pipes will be supplied by the ChPA. 500 mm X 500 mm
66300 mm X 300 mm
67200 mm X 200 mm
68Labour Charges for cutting and welding of flanges in fire fighting lines as detailed in Schedule - A.16\" Ø M S Flange
6914\" Ø M S Flange
7012\" Ø M S Flange
7110\" Ø M S Flange
728\" Ø M S Flange
736\" Ø M S Flange
744\" Ø M S Flange
75Labour charges for removing, reconditioning, refixing and commissioning of foot valve assembly with vertical suction pipe as detailed in Schedule - A in fire fighting pumps at Old Pump House and New Pump House including gaskets, fastners, etc., 14\"/16\" Ø foot valve assembly with vertical suction pipe at Old Pum House.
764\" Ø foot valve assembly with vertical suction pipe of PM pump at Old Pump House.
773\" Ø foot valve assembly with vertical suction pipe of PM pump at New Pump House.
7814\"/16\" Ø foot valve assembly with vertical suction pipe atNew Pump House.
79Labour charges for tower monitor gear box removing, reconditioning and re fixing with all required materials at an altitude of 20/22 meters at BD-I/BD-III as per detailed in Schedule-A.
80Labour charges for tower monitor funnel removing, reconditioning and re fixing with all required materials at an altitute of 20/22 Meters at Bd-I/BD-III as per detailed in Schedule ‘A’
81Labour charges for old pipes sent to ChPA\"s RSA yard by his own transport arrangement as detailed in Schedule-‘A’.
82Labour charges for cutting existing 14\"/16\" dia redundent Tower Monitor pipe line from Old Pump House to BD-I and replacing of punctured/Weakened portions of the fire fighting pipeline with the removed pipe including cutting, fabrication, laying, welding in the existing tower monitor/hydrant pipeline from New Pump House to BD-I as detailed in Schedule-‘A’.
83Labour charges for Chipping, cleaning, painting of renewed portions by one coat of Epoxy Zinc Rich Primer and two coats of Epoxy Post Office Red including supply of paints and other materials as detailed in Schedule-‘A’.
84b) Installation

AI Tender Summary

OUR REF NO 44763489
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 40.82 Lakhs
LAST DATE 02-09-2024
Authority
Authority Name Chennai Port Trust
Work Description Tender For Annual Repair And Maintenance For Fire Fighting Lines Pertaining To Tower Monitor Line, Fire Hydrant Lines From Oph To Bd I, From Nph To Bd I And Also From Nph To Ms. Iocl, Foreshore Terminal At Oil Dock For Period Of Two Years In Chennai Port Authority
Basic Detail
Tender No MEE/32/2024/Dy CME (MP and OH)
Bidding Type Tender
Location
City chennai
State Tamil Nadu
Key Dates
Publish Date 14 Aug 2024
Submission Date 02 Sep 2024
Open Date 03 Sep 2024
Finance
Tender Value 40.82 Lakhs
Tender Fee Ref. Documents
EMD 81656
Exemption Available
Document List
52e21866-5413-4413-b434-0ae70a00a3c8.html
BOQ_863108.xls
TD.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 14, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 02, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 03, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

52e21866-5413-4413-b434-0ae70a00a3c8.html

xls

BOQ_863108.xls

pdf

TD.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders