| 1 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000m as per Technical Specification Clause 202. |
| 2 | (A) Cement Concrete |
| 3 | (B)Reinforced Cement Concrete |
| 4 | Removing all types of Hume pipes and stacking within a all leadand lift of 1000 m including Earthwork and Dismantalling of Masnory Works as per Technical Specification Clause 202 |
| 5 | Earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deletarious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling trenches with excavated suitable material. |
| 6 | A) Up To 3.00m Depth |
| 7 | B) Above 3.00m Depth |
| 8 | Dewatering on BHP basis by using water pump including diversion of stream, providing cofferdams, earthern bunds etc. as may be necessary for foundation and other parts of the the works and pumping out water during and after excavation as may be required by using 5.0 to 9.0 BHP pump etc. complete. (prior approval of Superintending Engineer will be necessary) |
| 9 | Providing concrete for plain cement concrete M-15 in foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 |
| 10 | Providing reinforced cement concrete M-30 in foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 |
| 11 | Supplying fitting, and placing TMT bar reinforcement in foundation complete as per drawing and technical spcifications Clauses 1000 & 1202 |
| 12 | Providing and layingP.C.C. M-25 Grade cement concrete in substructure complete as per drawings and technical specification Clause 802, 804, 805, 806, 807, 1202 and 1204 |
| 13 | Providing and layingR.C.C. M-30 Grade cement concrete in substructure complete as per drawings and technical specification Clause 802, 804, 805, 806, 807, 1202 and 1204 |
| 14 | Supplying fitting, and placing TMT bar reinforcement (Fe 415) in substructure complete as per drawing and technical spcifications Clauses 1002,1005,1010 and 1202 |
| 15 | Sand Filling in foundation trenches as per drawing and Technical Specification Clause 305.3.9 |
| 16 | Providing pressure relief pipes 100 mm dia. in bottom slab of box cell on a filter media base of 500 mm x 500 mm as per drawing and technical specification Clause 1205.5.7 |
| 17 | Providing and laying filter media with granular crushed aggregates as per specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wallto the full height compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8 |
| 18 | Providing and laying 0.90meter thick metal mat consisting of rubble, oversize metal and normal size metal in specified thickness as per detailed drawing including supplying all materials, hand packing of rubble, spreading metal in layers and hard murum including watering and compaction with power roller etc. complete. |
| 19 | Backfilling behind abutment, wing wall and return wall complete as per drawings and technical specification Clause 1204.3.8 |
| 20 | Providing weepholes in plain concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(v) :20(h) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 |
| 21 | FOR APPRON Providing and laying of apron with cement concrete blocks of size as per Table 1300.1 cast-in-situ and made with nominal mix of M-15 grade cement concrete as per drawing and technical specifications Clause 1301 |
| 22 | Providing and laying reinforced cement concrete M-30 in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 |
| 23 | Providing and laying cement concrete Wearing Course M-30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 |
| 24 | Providing and layingR.C.C. M-30 Grade cement concrete in substructure complete as per drawings and technical specification Clause 802, 804, 805, 806, 807, 1202 and 1204 |
| 25 | Supplying fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical spcifications Clauses 1002,1010 and 1202 |
| 26 | RAILINGProviding and fixing in position railing consisting of IS Rolled steel joist posts designation IS MB 100 (100 x 50) at 2.5m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and technical specifications Clause 1208.2 |
| 27 | Providing tar paper between cutoff & raft including laying in proper position etc. complete. |
| 28 | Providing expansion joints with 25mm thick bituminous pad as per detailed drawings etc. complete. |
| 29 | Providing and fixing 90cm x 60cm Marble plate engraving 10cm. Height letter, figures including painting the lefters/ figures with approved colour and shade complete |
| 30 | Cleaning grass and removal of rubbish up to a distance of 30m outside the periphery of the area as per Technical Specification Clause 201 |
| 31 | Scarifying the existing bituminous road surface to a depth of 150mm and disposal of scarified material with all lead and lift as per Technical Specification Clause 301.4 |
| 32 | Excavation for roadwork in soil with hydraulic excavator of 0.9 One Cubic Meter bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with all lift and lead as per Technical Specification Clause 302.3 |
| 33 | Construction of embankment with approved materials deposited at site from raodway cutting and excavation from drain and foundation of other structures graded and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 |
| 34 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5m, transporting to site, spreading , grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2with a lead upto 1000 m as per technical Specification Clause 301.5 |
| 35 | Construction of granular sub-base by providing Grading-I material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavatorat OMC, and compacting with vibratorywheel roller to achieve the desired density, complete as per Technical Specification Clause 401. |
| 36 | Providing, laying, spreading and compacting stone aggregates of specific sizes to Water Bound Macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405. |
| 37 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405 |
| 38 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope andcompacting with vibratory roller to meet requirement of Table 300.2 with all lead as per Technical Specification Clause 303.1 |
| 39 | Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.85 Kg / One Square Meter using mechanical means as per Technical specification Clause 502 |
| 40 | Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of0.275 Kg per One Square Meter on the prepared granular surfaces treated with primer and cleaned with Hydraulic broom as per Technical Specification Clause 503 |
| 41 | Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2mm to 5.6mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat as per Technical Specification Clause 508. |
| 42 | Providing and laying Seal Coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type B, as per Technical Specification Clause 510 |
| 43 | Providing and laying filter material undermeath pitching in slopes complete as per drawing and Technical Specification Clause 1302 |
| 44 | Providing and laying pitching of cement concrete blocks of size as per Table 1300.2, cast in cement concrete of grade M-15 |
| 45 | Providing concrete for plain cement concrete M-10 in foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 |
| 46 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material and single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets. Clause 1106. 1000 mm dia pipe |
| 47 | Reinforced cement concrete M-15 grade Boundary Pillar/ Local Stone of standard design as per IRC: 25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704. |
| 48 | Painting lines, dashes, arrows etc. on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702 |
| 49 | Providing and Laying hot applied thermo plastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5mm thick including 1.5 Refractive index reflectorizing glass beads @ 250 gm/ One Square Meter. Thickness of 2.5mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be >250m cd/ One Square Meter/ lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/ One Square Meter/ lux and Qd of 100 mcd/ One Square Meter/ lux measured at the end of 2 years by means of a Standard Reflecto meter of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streak sand holes complete as per direction of Engineer-in-charge and inaccordance with applicable specifications. (Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015). |
| 50 | Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15cm wide strips, fitted with 80x100mm rectangular or 75mm dia. circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings |
| 51 | Supplying and Fixing of Molded Shank Raised Pavement Markers / Cat\"s Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000Kilogramtested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kilogram. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer\"s recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer. |
| 52 | Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W \"metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)\" |
| 53 | Logo of PMGSY Project Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 One Number 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
| 54 | 800mm x 600mm Rectangular Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of4mm aluminum sheet bonded with white retro reflective sheeting ofClass B (Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3,supportedwith back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one One Number mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron postshall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B (Type IV High intensity micro-prismatic grade sheeting-HIP)sheeting shall have 7 yearswritten warrantyfrom the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificatein original should be submitted to the Engineer in charge by the contractor/supplier. |
| 55 | 600 mm Equilatral and Triangle Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of 600mmmade out of 3mm aluminum sheet bonded with white retro reflective sheeting ofClass B (Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one One Number ofM. S. angle iron post of size65 mm X 65 mm X 6 mm, 3.45 m long,duly paintedwithwith flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warrantyfrom the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificatein original should be submitted to the Engineer in charge by the contractor/supplier. |
| 56 | Typical PMGSY Citizen Informatory Board PMGSY Citizen\" s information Board- Providing and fixing of typical PMGSY Retro Reflective information board as peras per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottomduly rivetted with MSangles of 35 x 35x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler One Number NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/ Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor |
| 57 | PMGSY Project Information Board Sign Board of PMGSY Project Information :Providing and fixing of typical retro reflective PMGSY Project informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of ThreePlates ACP (Aluminum Composite Panel), material specificaitons as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The middle 4mm ACP plate of will be 1200x150mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The main 4mm ACP lower most plate will be 1500mmx600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of lower most plate and flat iron frame of the middle plate will be welded to twoOne Number 75mm x75mm x 12 swg sheet tubes posts placed at 1125mm apart centre to centre. the top of the middle plate will be flushed with the top of 75mm dia medium steel tube posts and these posts will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level and the bottom of the middle plate will be 100mm above the toplevel of the lower most plate. the diamond shaped plate mounted over flat angle iron frame will be connected to middle plate by square steel section of 47mmx47mm, thickness12SWG having a spacing of 100mm between the diamond shaped plate and middle plate and this square section will be riveted to the bottom point of the diamond shaped plate. PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler One Number NRRDA-P013 (11)/ 3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.2 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor. |