Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 02-09-2024 | Date Extension | Date | 09-09-2024 |
| Sl. No. | Item Description |
| 1 | OD: Supplying, fixing, testing and commissioning of Twin lobe air blower for out door application complete with air filter, motor of 1500 rpm with pressure gauges, pressure relief valve, acoustic hood, suction silencer with suitable flanges, common motor and compressor base frame with motor including all accessoriescomplete as per technical specification,including dismantling and removal of old blower and its accessories, connection to existing air line, etc. , the dismantled old items shall be shifted to RPIPL store etc. complete as per the direction of the Engineer in Charge:- Capacity: 250 m3/hr, Pressure: 0.4 kg/cm2, |
| 2 | OD : Effluent Transfer Pump : Supplying , fixing, testing and commissioning of self priming, non clog centrifugal pump for rated continuous duty and efficiency, CI construction, bronze impeller, mechanical sealcomplete with 3phase motor,suitable for operation on 415+/-10% volts, 50HZ, A C power supply etc. complete in all respects as required by the standard specifications complete with all accessories as per technical specification, including dismantling and removal of old pump and its accessories, connection to existing pipeline, etc. , the dismantled old items shall be shifted to RPIPL store etc. complete as per the direction of the Engineer in Charge :- Capacity: 12.5 m3/hr, Head: 10 m |
| 3 | OD : Effluent Recirculation Pump at Bio Tower I: Supplying , fixing, testing and commissioning of self priming, non clog centrifugal pump for rated continuous duty and efficiency, CI construction, bronze impeller, mechanical sealcomplete with 3phase motor,suitable for operation on 415+/-10%volts, 50HZ, A C power supply etc. complete in all respects as required by the standard specifications complete with all accessories as per technical specification, including dismantling and removal of old pump and its accessories, connection to existing pipeline, etc. , the dismantled old items shall be shifted to RPIPL store etc. complete as per the direction of the Engineer in Charge :- Capacity: 35 m3/hr, Head: 10 m |
| 4 | OD : Effluent Recirculation Pump at Bio Tower II: Supplying , fixing, testing and commissioning of self priming, non clog centrifugal pump for rated continuous duty and efficiency, CI construction, bronze impeller, mechanical sealcomplete with 3phase motor,suitable for operation on 415+/-10% volts, 50HZ, A C power supply etc. complete in all respects as required by the standard specifications complete with all accessories as per technical specification, including dismantling and removal of old pump and its accessories, connection to existing pipeline, etc. , the dismantled old items shall be shifted to RPIPL store etc. complete as per the direction of the Engineer in Charge :- Capacity: 25 m3/hr, Head: 10 m |
| 5 | OD : Bio Sludge Recirculation Pump at Secondary Clarifier: Supplying , fixing, testing and commissioning of self priming, non clog centrifugal pump for rated continuous duty and efficiency, CI construction, bronze impeller, mechanical sealcomplete with 3phase motor,suitable for operation on 415+/-10% volts, 50HZ, A C power supply etc. complete in all respects as required by the standard specifications complete with all accessories as per technical specification, including dismantling and removal of old pump and its accessories, connection to existing pipeline, etc., the dismantled old items shall be shifted to RPIPL store etc. complete as per the direction of the Engineer in Charge :- Capacity: 10 m3/hr, Head: 10 m |
| 6 | OD : Filter Feed Pump : Supplying , fixing, testing and commissioning of centrifugal pump for rated continuous duty and efficiency, CI construction, bronze impeller, mechanical sealcomplete with 3phase motor,suitable for operation on 415+/-10%volts, 50HZ, A C power supply etc. complete in all respects as required by the standard specifications complete with all accessories as per technical specification, including dismantling and removal of old pump and its accessories, connection to existing pipeline, etc., the dismantled old items shall be shifted to RPIPL store etc. complete as per the direction of the Engineer in Charge :- Capacity: 12.5 m3/hr, Head: 35 m |
| 7 | OD: Filtrate pump : Supplying and fixing of self priming, non clog centrifugal pump for rated continuous duty and efficiency, CI construction, bronze impeller, complete with 3phase motor, FRP motor cover, pressure gauge, suitable for operation on 415+/-10% volts,50 HZ,AC power supply etc. complete in all respects as required by the standard specifications and shall suit following capacities complete with all accessories as per technical specification Capacity: 5 m3/hr, Head: 10 m |
| 8 | OD : Supplying,fixing and commissioning of mechanically actuated diaphragm dosing pump with all wetted parts in PP construction suitable for pumping Alum/Limesolution including cost of valve, suction and delivery lines using heavy duty PVC tubes, etc. and complete with all accessories : capacity 0- 100 LPH @ 1.5Kg/cm2 |
| 9 | OD : Supplying, fixing, testingand commissioning of electro magnetic dosing pump with all wetted parts in PP construction suitable for pumping HOCl solution including cost of valve, suction and delivery lines using heavy duty PVC tubes, etc. and complete with all accessories : capacity 0-6LPH @ 3.5 Kg/cm2 |
| 10 | OD : Supply, erection, testing and commissioning of Electro magnetic flow meter suitable for fixing in Treated water line with a flow rate of 10 - 15 Cum./Hr with SS construction and IP 68 protection, wall mounting facility, cables, flow transmitter, converter, integrator, totalizer, display unit and all accessories: 63 mm PVC line |
| 11 | OD: Fine bubble diffuser system : Supplying and fixing of fine bubble tubular diffuser system of 90 mm dia and 1000 mm length, EPDM make with capacity of min 7m3/hrwith suitable SS clamp etc. as per technical specification, including dismantling and removal of old diffusers and its accessories, connection to existing pipeline, etc., the dismantled old items shall be shifted to RPIPL store etc. complete as per the direction of the Engineer in Charge. |
| 12 | Supply and fixing PVC Bio Fills of 0.6 mm thick (Corrugated, UV Stabilised, Double edge Folded type in black colour ) in standard dimension of 1200x600x600 mm with void ratio more than 97% and specific surface area not less than 102 Sq.m /Cum . Dry weight of the media shall be 35 KG/Cum,including dismantling and removal of old media from bio tower, cleaning, cost of all materials, labour charges, required tools,transportation loading and unloading charges etc. complete, the removed materials shall be disposed asper the direction of the Engineer in Charge. |
| 13 | Supply and fixing PVC Bio Fills of 0.4 mm thick (Corrugated, UV Stabilised, Double edge Folded type in black colour ) in standard dimension of 1200x600x600 mm with void ratio more than 97% and specific surface area not less than 102 Sq.m /Cum . Dry weight of the media shall be 28 KG/Cum,including dismantling and removal of old media from bio tower, cleaning, cost of all materials, labour charges, required tools,transportation loading and unloading charges etc. complete, the removed materials shall be disposed asper the direction of the Engineer in Charge. |
| 14 | Supply and fixing FRPfeed well of size 600 mm dia x 1250 mm deep ( thickness 4mm) with necessary supports in M S with epoxy painting in settling tank after removal of the old feed well, including cost of all materials, labour charges, required tools,transportation loading and unloading charges etc.including dismantling and removal of old well and its supports etc., the dismantled old items shall be shifted to RPIPL store etc. complete as per the direction of the Engineer in Charge. |
| 15 | OD : Supplying and fixing of clarifier rake mechanism for secondary clarifier of 4.30 m dia and 2.50 m SWD complete with central bridge, walk way with ladder, handrails etc. of MS construction with epoxy painting, rake mechanism including rake arm, scrapper blade, cone scrapper, feed well of 1m dia and 1.4 m depth etc. in FRP construction ( thickness 4mm), central shaft with MS construction, base plate, central heavy duty bearing, 1HP motor assembly and 2 nos. gearboxesandcomplete with all other accessories as per technical specification, including dismantling and removal of old clarifier mechanism and its accessories etc., the dismantled old items shall be shifted to RPIPL store etc. complete as per the direction of the Engineer in Charge. |
| 16 | OD - Dual Media Pressure sand Filter :-Servicing of the existing Filter of size 1000 dia. X 1500 HOSby remove entire filter media from the filter vessels, cleaning the interior of the vessels, cleaning the pebbles, refilling the pebbles, filling the new course/medium/fine sandin layers as per design, including cost of filter media, transportation, loading andunloading charges, all labour charges, disposal of waste materials etc. complete as directed by the Engineer in charge. |
| 17 | OD - Carbon Filter :- Servicing of the existing filter of size 1000 dia. X 2100 HOS by remove entire media from the filter vessels, cleaning the interior of the vessels, cleaning the pebbles/media, refilling the pebbles/media, filling the new activated carbon media ( Iodine Value - 900) in layers as per design, including cost of activated carbon, transportation, loading andunloading charges, all labour charges, disposal of waste materials etc. complete as directed by the Engineer in charge. |
| 18 | OD : Providing and fixing of C I non-return valve of approved quality,with pressure PN 16-, Horizontal appropriate with MS lines including supplying and fixing necessary tail pieces,flanges with bolts, nuts,including removal of the existing old valve, cost of all materials, transportation, labour charges etc,. complete as directed by the Engineer in Charge. :- Size - 100 mm |
| 19 | OD : Providing and fixing ofbutterfly valve,appropriate with MS lines including supplying and fixing necessary tail pieces,flanges with bolts, nuts, etc. completeincluding removal of the existing old valve, cost of all materials, transportation, labour charges etc,. complete as directed by the Engineer in Charge. :- Size - 100 mm |
| 20 | OD : Providing and fixing of C I Ball valve,appropriate with MS lines including supplying and fixing necessary tail pieces,flanges with bolts, nuts, including removal of the existing old valve, cost of all materials, transportation, labour charges etc,. complete as directed by the Engineer in Charge. :- Size -40mm |
| 21 | OD: Providing and fixing ofpolypropylene Ball valve ( flanged type ),appropriate with HDPE lines including supplying and fixing necessary tail pieces,flanges with bolts, nuts, including removal of the existing old valve, cost of all materials, transportation, labour charges etc,. complete as directed by the Engineer in Charge. :- Size - 90 mm |
| 22 | OD: Providing and fixing ofpolypropylene Ball valve ( flanged type ),appropriate with HDPE lines including supplying and fixing necessary tail pieces,flanges with bolts, nuts, including removal of the existing old valve, cost of all materials, transportation, labour charges etc,. complete as directed by the Engineer in Charge. :- Size - 63 mm |
| 23 | OD: Providing and fixing ofpolypropylene Ball valve ( flanged type ),appropriate with HDPE lines including supplying and fixing necessary tail pieces,flanges with bolts, nuts, including removal of the existing old valve, cost of all materials, transportation, labour charges etc,. complete as directed by the Engineer in Charge. :- Size - 50 mm |
| 24 | OD: Providing and fixing ofpolypropylene Ball valve ( flanged type ), appropriate with HDPE lines including supplying and fixing necessary tail pieces,flanges with bolts, nuts, including removal of the existing old valve, cost of all materials, transportation, labour charges etc,. complete as directed by the Engineer in Charge. :- Size - 40 mm |
| 25 | OD: Providing and fixing ofC I Diaphragmvalve ( flanged type ),appropriate with MS lines including supplying and fixing necessary tail pieces, flanges with bolts, nuts, etc. including removal of the existing old valve, cost of all materials, transportation, labour charges etc,. complete as directed by the Engineer in Charge :- Size - 40mm |
| 26 | OD - Cleaning of Rubber trap, screen andgrit chamber by removing, water, all accumulated sludge, rubber waste, other materials and stacking the same at the storage shed, washing and cleaning , including side wall, disposing theslurry / waste materials away from the immediate premises, without causing any damage to the existing structure and installations,includingall labour charges, hire charges of toolsetc. complete as per the direction of the Engineer in charge. |
| 27 | OD - Cleaning of Equalisation Tank by removing all accumulated sludge, rubber waste, other materials and stacking the same at the storage shed, washing and cleaning , including side wall, disposing theslurry / waste materials away from the immediate premises, without causing any damage to the existing structure and installations,includingall labour charges, hire charges of toolsetc. complete as per the direction of the Engineer in charge. |
| 28 | OD - Cleaning of flocculation tank by removing all accumulated sludge, rubber waste, other materials and stacking the same at the storage shed, washing and cleaning , including side wall, disposing theslurry / waste materials away from the immediate premises, without causing any damage to the existing structure and installations,includingall labour charges, hire charges of toolsetc. complete as per the direction of the Engineer in charge. |
| 29 | OD - Cleaning of Primary Clarifier by removing all accumulated sludge, rubber waste, other materials and stacking the same at the storage shed, washing and cleaning , including side wall, disposing theslurry / waste materials away from the immediate premises, without causing any damage to the existing structure and installations,includingall labour charges, hire charges of toolsetc. complete as per the direction of the Engineer in charge. |
| 30 | OD - Cleaning of Bio Tower I & II by removing all accumulated sludge, rubber waste, other materials and stacking the same at the storage shed, washing and cleaning , including side wall, disposing theslurry / waste materials away from the immediate premises, without causing any damage to the existing structure and installations,includingall labour charges, hire charges of toolsetc. complete as per the direction of the Engineer in charge. |
| 31 | OD - Cleaning of settling tank by removing all accumulated sludge, rubber waste, other materials and stacking the same at the storage shed, washing and cleaning , including side wall, disposing theslurry / waste materials away from the immediate premises, without causing any damage to the existing structure and installations,includingall labour charges, hire charges of toolsetc. complete as per the direction of the Engineer in charge. |
| 32 | OD - Cleaning of Secondary Clarifier by removing all accumulated sludge, rubber waste, other materials and stacking the same at the storage shed, washing and cleaning , including side wall, disposing theslurry / waste materials away from the immediate premises, without causing any damage to the existing structure and installations,includingall labour charges, hire charges of toolsetc. complete as per the direction of the Engineer in charge. |
| 33 | OD - Cleaning of Aeration tank by removing water, all accumulated sludge, rubber waste, other materials and stacking the same at the storage shed, washing and cleaning , including side wall, disposing theslurry / waste materials away from the immediate premises, without causing any damage to the existing structure and installations,includingall labour charges, hire charges of toolsetc. complete as per the direction of the Engineer in charge. |
| 34 | OD - Cleaning of Filter feed tank by removing all accumulated sludge, rubber waste, other materials and stacking the same at the storage shed, washing and cleaning , including side wall, disposing theslurry / waste materials away from the immediate premises, without causing any damage to the existing structure and installations,includingall labour charges, hire charges of toolsetc. complete as per the direction of the Engineer in charge. |
| 35 | OD - Cleaning of Sludge drying beds ( 6 Nos.) and filtrate sump, by removing water, all accumulated sludge, rubber waste, filter mediaother materials and stacking the same at the storage shed, washing and cleaning , including side wall, disposing theslurry / waste materials away from the immediate premises, without causing any damage to the existing structure and installations,includingall labour charges, hire charges of toolsetc. complete as per the direction of the Engineer in charge. |
| 36 | OD - Cleaning of air purging grid at Equalisation tank by removing all pipes and fittings, washing and cleaning inside and outside of the pipe for the smooth flow of air, refixing the pipes in original position with stainless steel clamps as required, includingall labour charges, cost of required materials (cost of clamps, screws etc. ) hire charges of toolsetc. complete as per the direction of the Engineer in charge.( cost for replacing the damaged portion of the pipe will be paid extra). |
| 37 | OD - Cleaning of air purging grid at Flocculation tank by removing all pipes and fittings, washing and cleaning inside and outside of the pipe for the smooth flow of air, refixing the pipes in original position with stainless steel clamps as required, includingall labour charges, cost of required materials (cost of clamps, screws etc. ) hire charges of toolsetc. complete as per the direction of the Engineer in charge.( cost for replacing the damaged portion of the pipe will be paid extra). |
| 38 | OD - Cleaning of air purging grid at Filter feedtank by removing all pipes and fittings, washing and cleaning inside and outside of the pipe for the smooth flow of air, refixing the pipes in original position with stainless steel clamps as required, includingall labour charges, cost of required materials (cost of clamps, screws etc. ) hire charges of toolsetc. complete as per the direction of the Engineer in charge.( cost for replacing the damaged portion of the pipe will be paid extra). |
| 39 | OD - Providing and fixing perforated PVC pipes andfittings in Bio Tower for sprinkling water, including fixing the pipe with clamps as required. This includes jointing of pipes & fittings with one step PVC solvent cement or flangesetc.complete as per direction of Engineer-in-Charge - 40 mm dia 6 Kgf/cm2, ISI marked |
| 40 | OD: Providing and fixing of BrassBall valve,appropriate with MS lines including supplying and fixing necessary tail pieces,flanges with bolts, nuts,all labour charges, hire charges of toolsetc. complete as per the direction of the Engineer in charge. - 25 mm |
| 41 | OD: Providing and fixing ofPVC Ball valve ,appropriate with PVClines including supplying and fixing necessary couplings, all labour charges, hire charges of toolsetc. complete as per the direction of the Engineer in charge - 63 mm |
| 42 | OD: Providing and fixing ofPVC Ball valve ,appropriate with PVClines including supplying and fixing necessary couplings, all labour charges, hire charges of toolsetc. complete as per the direction of the Engineer in charge - 50 mm |
| 43 | OD: Providing and fixing ofPVC Ball valve ,appropriate with PVClines including supplying and fixing necessary couplings, all labour charges, hire charges of toolsetc. complete as per the direction of the Engineer in charge - 40 mm |
| 44 | OD : Supplying and fixing Brassfoot valve with all accessories including cost and conveyance of all materials, labour charges etc complete as directed by the Engineer -in - charge at all levels. 50 mm dia |
| 45 | OD : Supplying and fixing Brass foot valve with all accessories including cost and conveyance of all materials, labour charges etc complete as directed by the Engineer -in - charge at all levels. 40 mm dia |
| 46 | OD: Providing and fixing of 100 mm dia M S Pressure Guage, 10 Kg/cm2, with all accessories, including all labour charges, hire charges of toolsetc. complete as per the direction of the Engineer in charge. |
| 47 | OD: Providing and fixing of 10mm dia Brass Ball Valve, with all accessories, including all labour charges, hire charges of toolsetc. complete as per the direction of the Engineer in charge. |
| 48 | OD - Supplying, laying/ fixing, testing and commissioning of 100 mm dia.M S pipe, class C(with necessary clampsand fittings but excluding valves, strainers, gauges etc.)etc completeas per specifications and as required, including all labour charges, hire charges of tools and plants etc. complete as per the direction of the Engineer in charge. |
| 49 | OD - Supplying, laying/ fixing, testing and commissioning of 40 mm dia.M S pipe, class C (with necessary clampsand fittings but excluding valves, strainers, gauges etc.)etc completeas per specifications and as required, including all labour charges, hire charges of tools and plants etc. complete as per the direction of the Engineer in charge. |
| 50 | OD - Supplying, laying/ fixing, testing and commissioning of 50 mm dia. class CM S pipe (with necessary clampsand fittings but excluding valves, strainers, gauges etc.)etc completeas per specifications and as required, including all labour charges, hire charges of tools and plants etc. complete as per the direction of the Engineer in charge. |
| 51 | OD - Removing filter media from the filter beds without making any damages to the existing structures and back manifolds and stacking at a safe and convenient place for segregation process and as per the directions of the department officers etc. complete. |
| 52 | OD : Supplying and laying 40 mm broken stone in sludge drying bed in required thickness. The rate inclusive of cost and conveyance of all materials, labour charges etc complete all as per detailed specifications anddirections of the Engineer in charge at all levels. |
| 53 | OD : Supplying and laying 20 mm to 12.5mm broken stonein sludge drying bed in required thickness. The rate inclusive of cost and conveyance of all materials, labour charges etc complete all as per detailed specifications anddirections of the Engineer in charge at all levels. |
| 54 | OD : Supplying and laying 10mm to 6mmbroken stonein sludge drying bed in required thickness. The rate inclusive of cost and conveyance of all materials, labour charges etc complete all as per detailed specifications anddirections of the Engineer in charge at all levels. |
| 55 | OD : Supplying and laying Coarse sand (zone III)in sludge drying bed in required thickness. The rate inclusive of cost and conveyance of all materials, labour charges etc complete all as per detailed specifications anddirections of the Engineer in charge at all levels. |
| 56 | OD : Supplying and laying Fine sand (0.5-2mm) in sludge drying bed in required thickness. The rate inclusive of cost and conveyance of all materials, labour charges etc complete all as per detailed specifications anddirections of the Engineer in charge at all levels. |
| 57 | 15.19 : Dismantling steel work manually / by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per directions of Engineer -in-Charge. |
| 58 | 15.2.1 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge. - Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 59 | 15.23.1 : Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm |
| 60 | OD: Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead : - Polycarbonate sheet |
| 61 | 11.38 : Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of Ist quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete. |
| 62 | 10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 63 | 10.26.1 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.:- M.S. tube |
| 64 | 10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 65 | 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m:-All kinds of soil |
| 66 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) |
| 67 | 4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 68 | 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete |
| 69 | 5.9.2 : Centering and shuttering including strutting, etc. and removal of form for: Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 70 | 5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size |
| 71 | 5.12 : Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size) |
| 72 | 5.22.4 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete up to plinth level : - Hot rolled deformed bars |
| 73 | 2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 74 | 50.6.2.2 : Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete |
| 75 | 13.1.1 : 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 fine sand) |
| 76 | 13.7.2 : 12 mm cement plaster finished with a floating coat of neat cement of mix: 1:4 ( 1 cement : 4 fine sand) |
| 77 | 12.5 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 78 | 12.51.1 : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Ridges plain (500-600 mm) |
| 79 | 50.12.2.1 : Providing & fixing Poly carbonate corrugated sheet 0.8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling / self tapping screw of size (5.5x55 mm) with EPDM seal complete up to any pitch in horizontal/ vertical/ curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size shapes where ever required. |
| 80 | MORTH3.1 : Excavation for roadway in soil using manual means including loading in truck for carrying of cut earth to embankment site with all lifts and lead upto1000 metres |
| 81 | MORTH4.2. A.1 : Construction of granular sub-base by providing graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. - Grading-III -For lower sub base - Mix in Place Method |
| 82 | MORTH 55.22 : Supplying and laying interlocking tile 100 mm or nearest size thickness, minimum strength M 40 including providing a layer of 6 mm aggregate for 5 cm thickness, then laying interlock cobbles in lines and levels as per the directions of the departmental officers at site inclusive of all cost & conveyance charges etc.; complete. |
| 83 | 4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 84 | 13.81.2 : Dis tempering with Ist quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams /litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. :- Two coats |
| 85 | 13.112.1 : Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade :- Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface |
| 86 | 13.47.1 : Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 87 | 13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete. :- On steel work |
| 88 | 13.99.1 : Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work |
| 89 | 50.18.9.15.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge :-40 mm dia 6 Kgf/cm2 - External work - Exposed on wall |
| 90 | 50.18.9.16.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge :- 50 mm dia 6Kgf/cm2 - External work - Exposed on wall |
| 91 | 50.18.9.17.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge :- 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall |
| 92 | 13.71 : Lettering with black Japan pint of approved brand and manufacture |
| 93 | OD -Commissioning of CETP and stabilizing the system as per the instructions given by the Engineer in charge to ensure the treated effluent characteristics fall within the parameters stipulated by the Kerala State Pollution Control Board (KSPCB). Including supply of Chemicals/nutrients/consumables such as PAC, HOCL, polyelectrolyte, urea, dia-ammonium phosphate, hypochlorite, cow dung, alum, lime etc. and labour and supervision for commissioning the plant. Trail run/ operation of the plant for a minimum period of 15 days after commissioning. Water and Electricity required during the commissioning and trail run period will be borne by RPIPL. |
| 94 | OD : Supply and fixing outdoor type START/STOP (2way) push button station (IP65) including all the necessary accessories as required complete with suitable mounting arrangement. |
| 95 | 90.15.4.2 : Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance |
| 96 | 90.6.5.6 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 2 core 4.00 sq mm |
| 97 | 90.3.18.2 : Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required. |
| 98 | 90.14.28.1 : S & F Motor starters of the following ratings : Single phase DOL starters for 0.25HP to 3HP motor |
| 99 | OD : Supply of 4 sqmm 3 core PVC/XLPE insulated armoured cable with copper conductors for working Voltages up to and including 1100 volts, conforming IS 1584/part I/ 1988 for PVC IS 7098 part I for XLPE |
| 100 | OD : Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.:- (3C X 4 sqmm Cu) |
| 101 | OD : Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.:-(3 X 4 sq. mm) |
| 102 | OD : Supply, installation, testing and commissioning ofMPP Heavy Duty Cylindrical Type Capacitor sutable for existing LT panel : 1 kVAR |
| 103 | OD : Supply, installation, testing and commissioning ofMPP Heavy Duty Cylindrical Type Capacitor sutable for existing LT panel : 2 kVAR |
| 104 | OD : Supply, installation, testing and commissioning ofMPP Heavy Duty Cylindrical Type Capacitor sutable for existing LT panel : 3 kVAR |
| 105 | OD :By back of all dismantled equipment’s, pumps, motors, blower, valves, old M S structural materials, roofing sheets, bio fills etc. from the plant, including all labourcharges for removal, transportation, loading etc complete from the treatment plant/ RPIPL store. |