Name of Work: YCM हॉस्पिटल मधील रक्तपेढीकेंद्राकरिता उपकरणे/साहित्य खरेदीबाबत ..
Sl. No.
Item Description
1
YCM हॉस्पिटल मधील रक्तपेढीकेंद्राकरिता उपकरणे/साहित्य खरेदीबाबत ..
2
Platelet Agitator with inculcator- Technical Specification• Make- Terumo Penpol/Remi• Should have an input voltage of 230 +/- 10% V/50-60Hz, Single phase Ac.Should be table top• Should have single pane tempered glass door for safety and better visibility of platelet bags• Should have built in microcontroller-based temperature recorder and controller unit (TRCU) positioned at eye level for better visibility• Must have six inch, 7-day, ink-less pressure sensitive circular chart recorder and accuracy should be +/- 1 degree Celsius• Should be able to maintain a temperature of 22 degrees with +/- Degrees variations• Should have display of 4*7 Segment LED with 0.5°C display resolution• Should have refrigeration with Thermo electric cooling method & 4W LED tube for uniform lighting• Should have chart change and set button• Should comply IEC safety /EMI/EMC standards, ISO 9001, ISO 13485 certified andCE marked• Should have chamber mounted electrical outlet agitator• Should have built in voltage stabilizer• Should have CFL lamp inside the incubator• Should have magnetic gaskets for doors to prevent loss of air• Must incorporate a inbuilt battery backup of 2 hours to ensure continuous operation of the TRCU during power failure• Should have CFC free PU Insulation• Should be able to store minimum of 24/48 platelet bags• Should have 4 trays and be able to store minimum 24 platelet bags & trays to store 48 platelet bags• Should be flat bed agitator• Should have 65 +/-7 cycles motions per min• Should have agitation pause function for 10 sec• Should have LED indication for blown fuse• Should have audible intermittent beeps for power failure• Should have SS304 grade sliding stainless steel trays• Should comply IEC safety/EMI/EMC standards, ISO 9001, ISO 13485 and CE marked• Should have power supply of 220-240 volt at 50Hz single phase• Supplied with Servo voltage stabilizer capacity 5 KVA , Single Phase of reputed brand.• It should be C.E. or US FDA Approved• Warranty & AMC : Minimum three years comprehensive onsite warranty with three years comprehensive Maintenance and equipment calibration from the date of installation and commissioning
3
Blood Collection Monitor- Technical Specification• Make- Terumo Penpol/Remi• Input Power Supply- 18v, 3.3A D601100-240VAC 50-60 Hz power adaptor• Electrical Classification- Class II internally powered• Operation- Continuous• Power Consumption- 70VA, PF:0.52• Oscillation Details- 12+2 Oscillations per minute• Clamping mode- Motor activated clamping• Volume Setting Ranges- Insteps of5 ml foam 50 to 500 ml Automatic recall of set volume• LED Indications and audible alarm- High/Low flow indication End of collection power failure Battery low• Automatic clamping- When programmed volume reaches When flow rate is less than 20ml min for more than 2 min• Display-20x 4line character backlit LCD display• Time Measurement- Collection Time display• Accurancy-2% of the programmed Volume• Dimension in mm- 500mm x 190mm x 185mm• Equipment Weight- D601-4.5kg Power Adaptor-550g• Battery- 14.8v, 4.4AH Lithium Ion
4
Bench Top Non Refrigerated with Carbon Brushless Centrifuge- Technical Specification• Make- Terumo Penpol/Remi• Centrifuge design- Bench Top• Weight including Rotor in kgs-150• Maximum RPM with no load-20000• Number of steps of RPM Variation available in the settings (correspondingly RCF also varies)- 10• RPM setting accuracy- plus minus 5%• Type of Motor- With Carbon Brushless• Type of lid lock- Both Manual and Electronic• Maximum Noise level when working at 1 meter distance in db-56• Ambient operating Temperature range in Degree centigrade Celsius and Humidity Range-0 to 40 and relative humidity is 15 to 80%• Rotor imbalance diagnostics and automatic stop if required- Yes• No of acceleration and deceleration profiles in built for rotor speed while automatic braking-\"Programmable from 50 to 200 Seconds in Interval of 5 Seconds\"• Maximum timer set point-60 minutes• Parameters to be displayed by the digital display- RPM, RCF, Set time, Run time, Rotor running indication unbalancing if any• Display Type- LCD• Speed controller- Microprocessor controlled pre programmed speed controller which can control RPM as well as RCF• Configuration of Rotor supplied with centrifuge machine- Swing Out• Rotor Feature With Reference to Autoclavability- Autoclavable Rotor @121 Degree Celsius• Type of Tubes which can be used with centrifuge machine- Polypropylene Centrifuge tubes and Glass centrifuge tubes• Size of rotor supplied with centrifuge-16x15ml((For swing out type rotor RPM 5000)• Maximum RCF-300• Power supply-230 Volts 50 Hz AC ± 10%• Power consumption in watts-240• Length of the Centrifuge in mm-470• Width of the Centrifuge in mm-380• Length of Power cord in meters-3• Accessories- Spanner to tight or loose Nut of Rotor on Motor shaft head puller, spare rotor nuts ,fuse-2, Instruction Manual Book ,installation CD, Power supply cable, Instruction Manual• Warranty & AMC- Minimum three years comprehensive onsite warranty with Comprehensive Maintenance and equipment calibration from the date of installation and commissioning.
5
RO+UV+UF+TDS Controller Water Filter for in blood centre donor- Technical Specification• Make- Kent/Aqua guard• Description- Reverse Osmosis Based Point of Use Water Treatment System for Drinking Purposes• Governing Specification- As per IS 16240• Point of Use of Drinking Water System- Plumber-In• Method of Mounting- Wall• Main Components- Sediment Filter, Absorption Filter, RO Membrane Element, Booster Pump, Reject Water Control Mechanism, Power Supply, Auto Shut-off Mechanism, TDS Display Meter• Additional Components-FlushingMechanism,Ultraviolet (UV) Disinfection Chamber/In Tank Sanitization, Ultrafiltration (UF) Membrane,TDS Control Valve, Mineraliser/Taste Enhancer Media,Activated Carbon Media• Materials of Construction- Corrosion-Resistant• Storage Tank- Yes• Storage Tank Capacity (in Ltr)- 5-50• Specify the Storage Tank Capacity-20 liter• Minimum Inlet Pressure-4.2 pound per sqare inch• Maximum Inlet Pressure-28.4 pound per sqare inch• Maximum Operatable Feed Water TDS (ppm)- 1000• Recovery Rating-25-35• Electrical Safety & Power Supply-230 V Single Phase• Warranty & AMC- Minimum three years comprehensive onsite warranty with Comprehensive Maintenance and equipment calibration from the date of installation