Tender For For Inspection And Rectification Of Installed Sas And Other Required Associated Work At 132Kv S/S Takha Under Etd-Ii Kanpur.
Tender Overview
Project Description
For Inspection And Rectification Of Installed Sas And Other Required Associated Work At 132Kv S/S Takha Under Etd-Ii Kanpur.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 12-Aug-2024 | Corrigendum | Technical Bid | 23-Aug-2024 |
BOQ
| Sl. No. | Item Description |
| 1 | Inspection and rectification of SIEMENS make Substation Automation System installed at 132KV S/S Takha. The following works are including for healthy SCADA communication.(a) Replacing the defective armourd optical fiber cable and splicing it if required any anywhere in the Ring. (b) Replacing the defective FO multimod ST-ST port patch cords. (c) Checking & Rectifying the healthiness of LIUs and its communicating ports. (d) Checking &Rectifying the healthiness of IEC 61850-7 Ethernet switches. (e) Replacing the defective CAT-5/LAN cables and checking its healthiness. (f) Rectifyingcommunication healthiness of MOD Bus RTU for various MFM meters. (g) Rectification/checking healthinessof GPS system and its time synchronisation with all relays. (h) Re-installation of old backupto SCADA. (I) Checking the healthiness of all protection relay\"s communication to SCADA. (j) Checking of all required events, alarms, numericals datas, status and signals to SCADA from various bays & feeders. (k) Checkingthe SLD of S/S to SCADA screen . (l) checking the all required operations of equipments from SCADA. (m) configuration of ethernet switches/modems/ RTU etc. if required. (n) installation of new window and SICAM230 software in standby PC, and reinstalling the old backup in HMI-2, making both HMI-1 & HMI-2 in all respect. at the time of rectification all required materials and computer parts will be arranged by department without extra charges, except the following given material will be provided by contractor.scada license key, activation key, old SAS backup, and software CD will be provided by department. |
| 2 | Configuration of Gateway / RTUfor transmission of Telemetry data viaIEC 104protocolto SLDCLucknow andBackup SLDC, Modipuram as per IP addressand physical addressprovided byUPPTCLandvalidation of real time data as per existing BCU relay at132kvS/STakha. solving the problem of SOE, time synchronization |
| 3 | Supply of27\" IPS LED computer monitor HP/DELL/LG etc. |
| 4 | Supply of Windows 7 OS with 32/64 bit suitable for ADVANTEC PC. |
| 5 | Supply of Fibre Optical Multimode patch cards for ST-ST, LC-LC, LC-ST, ports (each 5 meters). |
| 6 | Supply of Fibre Optical Multimode patch cards for ST-ST, LC-LC, LC-ST ports (each 10 meters). |
| 7 | Hot line stringing between the towers (NBDD+18and 220 KV Special Mono Pole Tower (30-60) (34 mtrs. Bottom Cross arms)) crossing of theNational highway(NH-86/NH-34) includes laying, tensioning, stringing, clamping, jointing etc. complete with ACSR Zebra of all Phases of both circuits including hoisting of insulator fittings of all neccessory hardware and accessories etc.(Note: No traffic block of NH will be arranged to complete the work) |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender