| 1 | BOQ 1 |
| 2 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils |
| 3 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 4 | CenteringandShutteringwithplywoodorsteel sheets including strutting, propping bracing both ways andremovalofformworkforfoundation, footings, strapbeam,raft,basesofcolumnsetc. |
| 5 | Providing and layingin positionspecified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishingwithrenderingincement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix |
| 6 | RandomRubblestonemasonryforwithhard stone infoundationandplinthinCementSand mortar above 30 CM thick wall in Cement Mortar1:6 ( 1-Cement : 6-Sand). |
| 7 | Filling available excavated earth (excluding rock) in trenches, plinth sideof foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. |
| 8 | Random rubble dry stone Kharanja under floor. |
| 9 | Centering&shutteringwithplywoodorsteel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for Columns, pillars, postsand struts etc. |
| 10 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. |
| 11 | Providing and layingin positionspecified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishingwith renderingincementsandmortar 1:3 (1 cement: 3 coarse sand) and making good thejointsandcostof plastizers(ifrequired) excludingthecostof centering,shutteringand reinforcementforWalls (anythickness) includingattachedpilasters, buttresses,plinth and string courses, fillets, columns, pillars, piers, abutments,postsandstrutsetc.M20 grade Nominal Mix / Design Mix |
| 12 | Providing and layingin positionspecified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishingwith renderingincementsandmortar 1:3 (1 cement: 3 coarse sand) and making good thejointsandcostof plastizers(ifrequired) excludingthecostof centering,shutteringand reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies,shelves,chajjas, lintels, bands, plain windowssills,staircasesandspiral staircases etc.M20 grade Nominal Mix / Design Mix |
| 13 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. (\"Original producers\" who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786). Thermo- mechanically Treated bars (Conforming of relevent IS code) |
| 14 | Brick work with F.P.S. bricks of class designation75insuperstructureaboveplinth level upto floor V level in all shapes and sizes in Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 15 | Kotastoneslabflooring25mmthickover20 mm (average)thick baselaidoverandjointed withgrey cementslurrymixedwithpigmentto matchthe shadeoftheslabincludingrubbing andpolishing complete withbaseofcement mortar1:4(1 cement:4coarsesand).For area of each slab from 2001 to 5000 Sq.Cm |
| 16 | P & F 1st qualityVitrified Porcelain Polished tiles onfloor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortionless than 0.08% and conforming to IS 15622 of approved make in all colour and shade,laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete. size 600 mm X 600 mm |
| 17 | Providingandfixingpressedsteeldoorframes confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressedmildsteelweldedorrigidly fixed together by mechanical means, adjustable lugswithsplitendtail toeachjambincluding steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applyinga coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4(M15 grade) completeasdirectedbyEngineer-in-charge: Profile E |
| 18 | Providingandfixingexternalgradeboardsolid core single leafflush door shutters ISI 2202-67 marked usingPhenolformaldehyderesin in glue both sides with approved steel fittings completeasper annexure\"A\" 30mmthick. Decorative teakveneer One side |
| 19 | Extrafor providing externallipping with2nd class teak wood battens6 mmminimumdepth onalledges ofshutters(overallareaofdoor shutter to be measured) Over item no. 8.13. |
| 20 | Extra for cutting rebate in flush door shutters for making doubleleafshutter(Totalareaof theshutter to be measured). |
| 21 | Providingandfixingsteelglazedwindow frame made out of 80x40 mm hollow sheet section of16gaugethickness,jointmitredwelded and grinded including hold fast of steel lugs 13mm x 3mm and 15 Cm long embedded in C Cblock 15 x 10 x 10 Cm of 1:3:6 nominal concrete and includingfixingofpivoted hingesofsuperior quality, window shuttersmade outof50x 25.0 mmhollowsteelsection15mmpaitam of18 gauge thickness, joint mitred and grinded including 10mm x 10mm square bars welded to frame forpaitamfixingfloatglass4mmthick paneswith glazingclipsandmetalsashputty and fixingof shuttersframespegstay,U shape handle 100 mm long, tower bolts 100 mm longofsteelpowdercoated superiorquality includingfixingandjointingwith framehinges primingcoatwithsteelprimercomplete inall respect as per direction of Engineer-in –chargeWindow openable. |
| 22 | ProvidingandfixingSquarebarsorotherflat welded to window, ventilatiors etc. |
| 23 | Providingandfixing1stqualitystandardwhite, grey, ivory,fumeredbrown,lightgreen,light blue and other light shades glazed tiles confirmingtoIS :13753&IS:15622ofsize 200mmx300mmin walls,floors,steps,pillars etc. laid on a bed of neat cement slurry finished withflushpointinginthewhite cementmixed withpigmenttomatchtheshadeof thetile complete(excludingthecostofcement plaster on walls and pillar). |
| 24 | 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) |
| 25 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc.complete fine finish 20mm thick. |
| 26 | Providing and applying white cement based putty over plasteredsurfacetopreparethesurface even and smooth complete. New PlasteredSurface (three or more coats) |
| 27 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. |
| 28 | Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Two or more coats on new work |
| 29 | Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work(Two [email protected]/10 sqm overand includingbasecoatof water proofingcementpaint [email protected]/10 sqm ). |
| 30 | Providingandfixing aluminumwork fordoors,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections andother sectionsofapprovedmake conformingtoIS:733andIS:1285,fixedwith rawl plugs and screws or with fixing clips ,or with expansionholdfasteners includingnecessary filling up of gap. at junctions , at top,bottom and sides with required PVC/neoprene felt etc. Aluminiumsectionshallbesmooth,rustfree, straight ,mitered and jointed mechanically whereverrequiredincludingcleatangle Aluminiumsnapbeadingforglazing/paneling,C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately).For shutters builtup standard tubular sections of openabledoors,windows & ventilators including providing & fixing hinges / rollers etc. and making provision forfixingof fittingswhereverrequired(lockes shall be paidfor separately).Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum |
| 31 | Providingandfixing12mmthickprelaminated three layermediumdensity(exteriorgrade) particle board Grade I, Type II conforming to IS : 12823bonded formaldehydesyntheticresin,of approvedbrandand manufactureinpaneling fixed in aluminium doors,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawingsanddirectionofengineer-in- charge. Pre-laminated particle board with decorative laminationononesideand balancing laminationonotherside. |
| 32 | Providingandfixingglazinginaluminiumdoor, window,ventilatorshuttersandpartitionsetc. with PVS / neoprene gasket etc. complete as per the architecturaldrawingsandthedirectionsof engineer- in-charge. (Cost of aluminium snap beading shall be paid in basicitem.) With float glasspanesof5.0 mmthickness(weightnot less than 13.50 kg/sqm) |
| 33 | P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No.15mmC.P.Pillarcock(IS:8934Mark)&32mmC.P. brass waste coupling of approved make, P.V.C Waste pipe with PVCnut 32 mm complete including cutting & making good the wall : Size 580 mm x 450 mm |
| 34 | P&FKitchen&Lab.SinkofapprovedmakewithC.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mmG.I.wastepipeup-tofloorlevelcompleteincluding cutting and making good the wall & floor Overall size (inches) 45 x 20 x 8 Bowl size (inches) 20x16x8 (with drain board) |
| 35 | P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :Gun-metal 25mm nominal bore. |
| 36 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall) |
| 37 | 20mm nominal size |
| 38 | 32mm nominal size |
| 39 | P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: C.P. Brass bib cock,15mm nominal bore. |
| 40 | P & F Ball Cock (IS :1703 Mark) with Rod & P.V.C. Ball complete : Brass wt. Not less than 300 gm,15mm. |
| 41 | P&FPVCStorageTankISIMarked(IS:12701) indicatingthe BISlicenseNo), ofapprovedmake with cover, 25mm dia 1M long G.I. over-flow pipe & 25Cm.longwashoutpipewithplug&socket, including making connection etc., complete of approved design: 1000 liters capacity. |
| 42 | Hoisting Charges for each floor for 1000 liters capacity. |
| 43 | ConstructionofCementConcreteChamber 125mm dia. C.P. Brass grating |
| 44 | P&F rigid PVC Pipe (IS:4985 mark)class II/(4 Kg./Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant.110 mm dia |
| 45 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. Rajasthan Black Above 3601 Cm2 Slabs |
| 46 | Supplying and fixing in walls machine cut and polished stone shelves, tands andin CM 1:3 with machine cut edges :Sand or other approved stone 50mm thick. |
| 47 | Providing & fixing 12 mm thick tegular edge Glass Fibre Reinforced Gypsum False ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-Charge. |
| 48 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it\"sISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 49 | Short point (up to 3 mtr.) |
| 50 | Medium point (up to 6 mtr.) |
| 51 | Long point(up to 10 mtr.) |
| 52 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it\"s ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSROn board |
| 53 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 25 mm |
| 54 | Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . Surface Mounting (with extruded alumn. Housing )Minimum lumen output 1950 lm |
| 55 | Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) |