Housing Urban and Rular Development Government Departments Closing in 0 days TDR #44537099

Tender For Medical Services (Mgps) Additional Items At Shri Vinoba Bhave Civil Hospital Campus Phase-I, Silvassa.

Issued by Government Departments · Silvassa, Dadra And Nagar Haveli
Tender Value
3.29 Crore
Estimated cost
Bid Submission
08 Aug 2024
0 days left
EMD
6.60 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Silvassa → Dadra And Nagar Haveli
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Medical Services (Mgps) Additional Items At Shri Vinoba Bhave Civil Hospital Campus Phase-I, Silvassa.-Supply, Installation, Testing and Commissioning of PRS for LMO : Pressure and flow control skidwith kit with interconnecting pipe : It will be supplied Safety valve, Long stream globe valve, Isolation Valve, Duplex High Pressure Regulator of 600nm3 alongwith Pressure guage 2 Supply, Installation, Testing and Commissioning of Oxygen Switch over vie control panel : It should complies with Health Technical Memorandum standards. Oygen from the VIE at 1050 kPa (10.5) bar and to reduce the pressure to a nominal 420 kPa (4.2 bar) pipeline distribution system pressure.Control panels are designed to regulate line pressure 28mm, sized pipe line. Mounted on a light weight mild steel zinc plated and passivated back plate assembly. It should be light weightless the 70Kg. All components degreased for oxygen use. Mild steel powder coated enclosure with inlet and outlet pressure gauges.Pressure Sensors : Pressure switches monitor inlet pressure. Dual line pressure switch monitor (high and low pressure). Pressure Reduction Capacity : Maximum inlet pressure: 2,800 kPa (28 bar). Outlet pressure reduced to: 420 kPa (4.2 bar). Flow Rate : 28mm system 2500-3,000 L/min. Relief Valve Settings : Nominal 4 bar manifold 550kPa (5.5 bar). 3 Supply, Installation, Testing and Commissioning of Lockable Line Valves size 76mm As per HTMStandard complies . Pre Piped Degreased Ball Valve with pipe extension. 4 Supply, Installation, Testing and Commissioning of Oil Free SCROLL Air Compressor (Total 6 air compressors) 3 air compressor of 85cfm (2350lpm each) running to produce 7000lpm as working and 3 air compressor of 85cfm (2350lpm each) to produce 7000lpm as stand by(5% tolernce will be allowed) 5 Supply, Installation, Testing and Commissioning of Medical Breathing Air Dryer System 2 air dryer as working and 2 air dryer as stand by. Stage one (X1) : Removes bulk liquid, particles and coalesced oil aerosols down to 0.1mg/m³ Stage two (XA) : Grade XA filtration removes liquids. Submicron particles and oil aerosols down to 0.01mh/m³. Stage three (PDBA) : Removes moisture down to -40°C (-40°F) and C ppm removes CO maintaining levels to less than 5ppm Stage Five (RAC): A combined activated carbon filter to remove odour, tastes and oil vapour and a particulates filter to remove down to 0.01 micron. 6 Supply, Installation, Testing and Commissioning ofAdditional 4 Stage Air Filter for 4 Bar 1no. Coarse coalescing filter with air quality standard ISO 8573-1: 2010. Element of E30612 grade 1no. Fine coalescing filter with air quality standard ISO 8573-1: 2010. Element of E30612 grade 1no. Fine Dust Filter with air quality standard ISO 8573-1: 2010. Element of E30612 grade 1no. Activated Carbon Filter with air quality standard ISO 8573-1: 2010. Element of E30612 grade 7 Supply, Installation, Testing and Commissioning ofAdditional 4 Stage Air Filter for 7 Bar 1no. Coarse coalescing filter with air quality standard ISO 8573-1: 2010. Element of E30612 grade 1no. Fine coalescing filter with air quality standard ISO 8573-1: 2010. Element of E30612 grade 1no. Fine Dust Filter with air quality standard ISO 8573-1: 2010. Element of E30612 grade 1no. Activated Carbon Filter with air quality standard ISO 8573-1: 2010. Element of E30612 grade 8 INR Zero Only

BOQ

Name of Work: Medical Services (MGPS) Additional Items at Shri Vinoba Bhave Civil Hospital Campus Phase-I, Silvassa.
Sl. No. Item Description
1Supply, Installation, Testing and Commissioning of PRS for LMO : Pressure and flow control skidwith kit with interconnecting pipe : It will be supplied Safety valve, Long stream globe valve, Isolation Valve, Duplex High Pressure Regulator of 600nm3 alongwith Pressure guage
2Supply, Installation, Testing and Commissioning of Oxygen Switch over vie control panel : It should complies with Health Technical Memorandum standards. Oygen from the VIE at 1050 kPa (10.5) bar and to reduce the pressure to a nominal 420 kPa (4.2 bar) pipeline distribution system pressure.Control panels are designed to regulate line pressure 28mm, sized pipe line. Mounted on a light weight mild steel zinc plated and passivated back plate assembly. It should be light weightless the 70Kg. All components degreased for oxygen use. Mild steel powder coated enclosure with inlet and outlet pressure gauges.Pressure Sensors : Pressure switches monitor inlet pressure. Dual line pressure switch monitor (high and low pressure). Pressure Reduction Capacity : Maximum inlet pressure: 2,800 kPa (28 bar). Outlet pressure reduced to: 420 kPa (4.2 bar). Flow Rate : 28mm system 2500-3,000 L/min. Relief Valve Settings : Nominal 4 bar manifold 550kPa (5.5 bar).
3Supply, Installation, Testing and Commissioning of Lockable Line Valves size 76mm As per HTMStandard complies . Pre Piped Degreased Ball Valve with pipe extension.
4Supply, Installation, Testing and Commissioning of Oil Free SCROLL Air Compressor (Total 6 air compressors) 3 air compressor of 85cfm (2350lpm each) running to produce 7000lpm as working and 3 air compressor of 85cfm (2350lpm each) to produce 7000lpm as stand by(5% tolernce will be allowed)
5Supply, Installation, Testing and Commissioning of Medical Breathing Air Dryer System 2 air dryer as working and 2 air dryer as stand by. Stage one (X1) : Removes bulk liquid, particles and coalesced oil aerosols down to 0.1mg/m³ Stage two (XA) : Grade XA filtration removes liquids. Submicron particles and oil aerosols down to 0.01mh/m³. Stage three (PDBA) : Removes moisture down to -40°C (-40°F) and C ppm removes CO maintaining levels to less than 5ppm Stage Five (RAC): A combined activated carbon filter to remove odour, tastes and oil vapour and a particulates filter to remove down to 0.01 micron.
6Supply, Installation, Testing and Commissioning ofAdditional 4 Stage Air Filter for 4 Bar 1no. Coarse coalescing filter with air quality standard ISO 8573-1: 2010. Element of E30612 grade 1no. Fine coalescing filter with air quality standard ISO 8573-1: 2010. Element of E30612 grade 1no. Fine Dust Filter with air quality standard ISO 8573-1: 2010. Element of E30612 grade 1no. Activated Carbon Filter with air quality standard ISO 8573-1: 2010. Element of E30612 grade
7Supply, Installation, Testing and Commissioning ofAdditional 4 Stage Air Filter for 7 Bar 1no. Coarse coalescing filter with air quality standard ISO 8573-1: 2010. Element of E30612 grade 1no. Fine coalescing filter with air quality standard ISO 8573-1: 2010. Element of E30612 grade 1no. Fine Dust Filter with air quality standard ISO 8573-1: 2010. Element of E30612 grade 1no. Activated Carbon Filter with air quality standard ISO 8573-1: 2010. Element of E30612 grade
8INR Zero Only

AI Tender Summary

OUR REF NO 44537099
AUTHORITY Government Departments
TENDER VALUE 3.29 Crore
LAST DATE 08-08-2024
Authority
Authority Name Public Works Department
Work Description Medical Services (Mgps) Additional Items At Shri Vinoba Bhave Civil Hospital Campus Phase-I, Silvassa.-Supply, Installation, Testing and Commissioning of PRS for LMO : Pressure and flow control skidwith kit with interconnecting pipe : It will be supplied Safety valve, Long stream globe valve, Isolation Valve, Duplex High Pressure Regulator of 600nm3 alongwith Pressure guage 2 Supply, Installation, Testing and Commissioning of Oxygen Switch over vie control panel : It should complies with Health Technical Memorandum standards. Oygen from the VIE at 1050 kPa (10.5) bar and to reduce the pressure to a nominal 420 kPa (4.2 bar) pipeline distribution system pressure.Control panels are designed to regulate line pressure 28mm, sized pipe line. Mounted on a light weight mild steel zinc plated and passivated back plate assembly. It should be light weightless the 70Kg. All components degreased for oxygen use. Mild steel powder coated enclosure with inlet and outlet pressure gauges.Pressure Sensors : Pressure switches monitor inlet pressure. Dual line pressure switch monitor (high and low pressure). Pressure Reduction Capacity : Maximum inlet pressure: 2,800 kPa (28 bar). Outlet pressure reduced to: 420 kPa (4.2 bar). Flow Rate : 28mm system 2500-3,000 L/min. Relief Valve Settings : Nominal 4 bar manifold 550kPa (5.5 bar). 3 Supply, Installation, Testing and Commissioning of Lockable Line Valves size 76mm As per HTMStandard complies . Pre Piped Degreased Ball Valve with pipe extension. 4 Supply, Installation, Testing and Commissioning of Oil Free SCROLL Air Compressor (Total 6 air compressors) 3 air compressor of 85cfm (2350lpm each) running to produce 7000lpm as working and 3 air compressor of 85cfm (2350lpm each) to produce 7000lpm as stand by(5% tolernce will be allowed) 5 Supply, Installation, Testing and Commissioning of Medical Breathing Air Dryer System 2 air dryer as working and 2 air dryer as stand by. Stage one (X1) : Removes bulk liquid, particles and coalesced oil aerosols down to 0.1mg/m³ Stage two (XA) : Grade XA filtration removes liquids. Submicron particles and oil aerosols down to 0.01mh/m³. Stage three (PDBA) : Removes moisture down to -40°C (-40°F) and C ppm removes CO maintaining levels to less than 5ppm Stage Five (RAC): A combined activated carbon filter to remove odour, tastes and oil vapour and a particulates filter to remove down to 0.01 micron. 6 Supply, Installation, Testing and Commissioning ofAdditional 4 Stage Air Filter for 4 Bar 1no. Coarse coalescing filter with air quality standard ISO 8573-1: 2010. Element of E30612 grade 1no. Fine coalescing filter with air quality standard ISO 8573-1: 2010. Element of E30612 grade 1no. Fine Dust Filter with air quality standard ISO 8573-1: 2010. Element of E30612 grade 1no. Activated Carbon Filter with air quality standard ISO 8573-1: 2010. Element of E30612 grade 7 Supply, Installation, Testing and Commissioning ofAdditional 4 Stage Air Filter for 7 Bar 1no. Coarse coalescing filter with air quality standard ISO 8573-1: 2010. Element of E30612 grade 1no. Fine coalescing filter with air quality standard ISO 8573-1: 2010. Element of E30612 grade 1no. Fine Dust Filter with air quality standard ISO 8573-1: 2010. Element of E30612 grade 1no. Activated Carbon Filter with air quality standard ISO 8573-1: 2010. Element of E30612 grade 8 INR Zero Only
Basic Detail
Tender No E-TENDER NOTICE NO. 11 OF 2024-25 (BLDG)
Bidding Type Tender
Location
City Silvassa
State Dadra And Nagar Haveli
Key Dates
Publish Date 02 Aug 2024
Submission Date 08 Aug 2024
Open Date 09 Aug 2024
Finance
Tender Value 3.29 Crore
Tender Fee 3000
EMD 6.60 Lakhs
Exemption Not Available
Document List
609e752d-1acf-40b9-8947-b949b38c03ac.html
2MGPSTechnicalSpecificati_1.pdf
BOQ_7338.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 02, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 08, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 09, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

609e752d-1acf-40b9-8947-b949b38c03ac.html

pdf

2MGPSTechnicalSpecificati_1.pdf

xls

BOQ_7338.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders