Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-08-2024 | ADDENDUM TO NIT | Other | 16-08-2024 |
| 2 | 07-08-2024 | CAVEAT | Other | 16-08-2024 |
| 3 | 01-08-2024 | DRAWING ATTACHMENT | Other | 16-08-2024 |
| Sl. No. | Item Description |
| 1 | 1.00 Upgradation & Maintenance of RoadFrom SH 177 To Malape to MDR-1Road. Km. 0.000 to 3.300 Km. Tal-Devgad, Dist -Sindhudurg. |
| 2 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (A) In area of Non-thorny jungle |
| 3 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (B) In area of thorny jungle |
| 4 | Excavation for roadwork in soil with hydraulic excavator of0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and croun-sections, and transporting to the embankment location with a lift upto 1.5 m and lead above 1000 m as per Technical Specification MORD 2014 Clause 302.3 |
| 5 | Excavation for roadway in Ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead above 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and croun-sections as per Technical Specification MORD 2014 Clause 302.3.5 |
| 6 | Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and croun-sections, loading and disposal of cut rock with a lift upto 1.5 m and with all leadsas per Technical Specification MORD 2014 Clause 302.3.5 |
| 7 | Excavation in Hard Rock (Blasting Prohibited) -Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 metre and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5 |
| 8 | Excavation for roadway in hard rockwith controlledblasting by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads upto 1000 mas per Technical Specification Clause 302.3.5 |
| 9 | Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1. |
| 10 | Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical SpecificationClause 301.5 |
| 11 | Construction of embankment with approved material obtained from borrow pits with al ift upto 1.5m, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 |
| 12 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. |
| 13 | Scarifying the existing Bituminous surface to a depth of 150 mm and disposal ofscarified material with a lift up to 3 m and lead upto 1000 mas per technical specificationaClause 301.4 |
| 14 | Construction of Granular Sub baseusing locally available materialProviding, laying spreading and compacting local material in block or large discrete particles, such as kankar, Laterite, Dhandla etc. as per Table 400.13 to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming requisite type of screening /binding materials to fill-up theinterstices of laid material watering and compacting to the required density as per Clause 405.3 and Technical Specification Cluase 408. Using Locally Availablematerial |
| 15 | Water Bound MacadamGrading II-(using Crusher Broken Metal & stone screening) Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smoothwheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. |
| 16 | Wet Mix Macadam (WMM)_Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing thematerial with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, layingin uniform layers in sub-base/base course on a well prepared sub-base and compacting with smoothwheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. |
| 17 | Reinforced cement concrete M15grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703Ordinary Kilometer Stone (Precast) |
| 18 | Reinforced cement concrete M15grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703200 m stone (precast) |
| 19 | Providing andfixing trap/granite/ quartzite/ gneiss/ guard stone/ indicator stones/ boundry stones of standard size& shape includingfixingIn ground andwashing complete Spec. No.: MORTH 807 |
| 20 | Providing and fixingRetro Reflective MMGSY/PMGSY LOGO informatory sign board with Logo as per section 1700 of MORD specification sand latest PMGSY Signage Manual/Circuler and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600 mm size, rivete dwith MS angle ironframe of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle ironframe of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat ironframe will be done neatly to have plain surface on one side. The angle ironframe of Both the plates will be welded to a 75mmx75mmx12 swg Mild steel post at/Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200 mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY/PMGSY logo, letters and numeral sonthe ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade asper the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo MMGSY Logo Project description on ClassA or ClassB type retroreflective sheeting using modern technology printing plat form. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The in k sused for printing shall be ecofriendly with VOC emissions complying to UL2801 standards and specifications for the different kinds of plat forms. The printe dsign shall be laminated by UV protected laminate and shall carry awarranty of 5 years & 7 years for ClassA and ClassB sheeting respectively for traffic colors.” All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1(B) and as directed by Engineerin-charge. A warranty for 5/7 years for the Retroreflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.(SOR ITEM NO.10.16 ) A) Retro Reflective sheeting class-A |
| 21 | Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4 mmt hick ACP sheet supported with Back support frame of 35x35x5 mm mild steel angle with are as not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm-3.5mt rheight, firmly fixed to the ground by means of properly designed foundation of M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level complete (as per MoRT & H specification No.801) (for area Less than 0.9 sqm). 7 Both border & background shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product offered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. The reshall be as tamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.(Village Name Board) |
| 22 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm equilateral triangular |
| 23 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm circular |
| 24 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting c. 600 x 450 mm Rectangular |
| 25 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting900 x 600milimeter reclangular |
| 26 | MMGSY/PMGSY Citizen\"s information Board-Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specification sand latest PMGSY Sign age Manual/Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35x35x5mm thic kM. Sangle shall be welded by two vertical M.S angle of 5mm thick to 75mmx75mm of 12 SWG square tubes/75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mmx600mmx75mm, below ground level . MMGSY/PMGSY logo, letter sand numer also n the ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade as per the latest MORD section1700 specifications (Refer Circuler no. NRRDA-P 013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo /MMGSY Logo/Project descriptionon ClassA or ClassB type retroreflective sheeting using modern technology printing platform. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The inks used for printing shall bee co friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of plat forms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed post sand steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed |
| 27 | Painting lines, Dashes, Arrows, etc. on Road in Two Coats on New Work,Painting lines, dashes, arrows, etc. on roads in two coatson new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702 |
| 28 | Providing and fixing Road junction / Information sign board of size 1.20 m x 1.20 m. prepared on 16 gauge M.S. sheet with angle iron frame of size 35 x 35 x 5 mm with cross bracing of size 35 x 35 x 5 mm including painting with one coat of zinc cromate stoving primer and two coats each of green/white back ground and back side gray stove enamelled, bonded with red retro reflective sheet Engineering grade, border / letters / numeral /arrows, coated with non pealable crystal clear protective transperent coat retaining 100% reflection includingtwo angle iron post of size 65 x 65x 6 mm of 3.65 m.long inflated at bottom drilled on top and painted in whiteand black bands of 30 cm. with 4 Nos. high strength G.I. bolts and nuts of size 10 mm dia. and 20 mm long sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with M-20 cement concrete of 60 cm x 60 cm x 75 cm size as directed by Engineer-in charge etc. complete. Mild Steel sheet with Engineering grade |
| 29 | Road Delineators: Providing and fixing steel pipe delineators of 10 cm. in diameter and total height of 130 cm, provided with 2 strips of white retroreflective sheeting of size 5 cm. x 32.5 cm. each fixed horizontally and 2 strips of red retroreflective sheeting each having size 5 cm. x 32.5 cm. fixed horizontally at top, with M.S. round cap having diameter 11 cm. and wire mesh at top (10 guage thick) and height of wire mesh 15 cm, M.S. hold fast 6 mm thick with 35 cm. in length, fixing the delineators in C.C. 1:4:8 concrete block of size 25 cm. x 25 cm. x 45 cm. with necessary excavation etc. completef. |
| 30 | Construction of Dry Lean Cement Concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to 15: 383, the size of coarse aggregate not exceeding 25 mm., cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing andincluding preparation of sub-grade surface if required etc. complete. |
| 31 | Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolana Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate (VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer In charge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc, complete as per specifications. (Excluding Dowel Bars and Tie Bars) |
| 32 | Providing and fixing in position TMT FE 500, 25mm dia dowel bars precoated with anticorrosive epoxy paint of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling, straightening, necessary cutting supported by TMTFE 500, chairs with proper alignment by using properly designed assembly of Bulkheads lubricating half length with bituminous paint as directed etc. complete. |
| 33 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. |
| 34 | Removing all types of Hume pipes and stackig within a lead of 1000 m including Earthwork and Dismantling of Masonry work as per Technical Specification clause 202- Above 600 to900mm dia. Hume pipe |
| 35 | Laying Reinforced Cement Concrete Pipe NP2 as per design in single row600 MM to 900 MM Dia-Reusable 600 to900mm dia. Hume pipe |
| 36 | Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. Ordinary soil By Mechanical means |
| 37 | Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. Ordinary rock (not requiring blasting) Upto 3 m depth |
| 38 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. ( Hard rock (blasting prohibited) |
| 39 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial.HARD rock (requiring blasting) |
| 40 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802,803, 1202 & 1203P.C.C grade M 10 Nominal mix (1:3:6) |
| 41 | Plain/reinforced cement concrete in sub structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix (1:2.5:5) |
| 42 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 mm NP3 Class As per Technical Specification MORD 2014 Cluase No. 1100 |
| 43 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.600 mm NP3 Pipe |
| 44 | Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106..600 mm NP2 Pipe |
| 45 | Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered/concrete surfaces as per drawing and Technical Specification Clause 1701 |
| 46 | Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701 |
| 47 | Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709, 1204.3.7 A.C. pipe 100 mm Dia |
| 48 | Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W \"metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)\" |
| 49 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. |
| 50 | Providingdryrubble latrite stone masonarywith available material. (lead 50 mt) |
| 51 | Providingdry rubble latrite stone masonary ( including royalty ) (lead 50 mt) |
| 52 | Providing laterite stone masonry in cement mortar 1:6 in super structure including racking out joints when plastering is to be done /striking joints when no plastering is to be done watering and scaffolding |
| 53 | Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600mmwith smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height , compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8 |
| 54 | Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 |
| 55 | Backfilling behind abutment, wing wall and return wallwith Granular Material complete as per drawings & technical specification Clause 1204.3.8 |
| 56 | Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 |
| 57 | Electric Pole Paintinng- Providing and fixing reflective fluorescent tape on old road sign board including cleaning / scraping and paintingexisting board etc. complete |
| 58 | Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015). |
| 59 | Cat Eye-Supplying & Fixing of Molded Shank Raised Pavement Markers / Cat\"s Eyemade of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer\"s recommendation and complete as directed by the engineer.The contractor shall submit a two year warrantyfor satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer. |
| 60 | Providing and Laying of Rumble strips with Plastirib 2K, or equivalent 2 component cold plastic profiled material to give total width of 500 mm and height of 10 mm. Ramp provided to give width of 145 mm, width of ribs to be 55mm laid at centre to centre distance of 35 mm, with reflective glass beads @ 350 gm / sqm. The finished surface to be levelled, uniform and free from streaks and holes, to be applied on the edge lines, including surface cleaning and cost of all materials etc. complete. |
| 61 | Painting Trees-Providing white and colour washing to road side trees in 2coats in 2 bands of white and one red band at centre of 30 cm height each including preparing the surface, cost of material, conveying etc. complete. |
| 62 | 2.00 Upgradation & Maintenance of RoadFrom MDR 9 to Nad Bholewadi Mahalunge Badewadi Road. Km. 0.000 to 3.050 Km. Tal-Devgad, Dist -Sindhudurg. |
| 63 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (A) In area of Non-thorny jungle |
| 64 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (B) In area of thorny jungle |
| 65 | Excavation for roadwork in soil with hydraulic excavator of0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and croun-sections, and transporting to the embankment location with a lift upto 1.5 m and lead above 1000 m as per Technical Specification MORD 2014 Clause 302.3 |
| 66 | Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead above 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and croun-sections as per Technical Specification MORD 2014 Clause 302.3.5 |
| 67 | Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and croun-sections, loading and disposal of cut rock with a lift upto 1.5 m and with all leadsas per Technical Specification MORD 2014 Clause 302.3.5 |
| 68 | Excavation in Hard Rock (blasting Prohibited) -Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 metre and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5 |
| 69 | Excavation for roadway in hard rockwith controlledblasting by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads upto 1000 mas per Technical Specification Clause 302.3.5 |
| 70 | Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1. |
| 71 | Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical SpecificationClause 301.5 |
| 72 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. |
| 73 | Scarifying the existing Bituminous surface to a depth of 150 mm and disposal ofscarified material with a lift up to 3 m and lead upto 1000 mas per technical specificationaClause 301.4 |
| 74 | Construction of Granular Sub baseusing locally available materialProviding, laying spreading and compacting local material in block or large discrete particles, such as kankar, Laterite, Dhandla etc. as per Table 400.13 to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming requisite type of screening /binding materials to fill-up theinterstices of laid material watering and compacting to the required density as per Clause 405.3 and Technical Specification Cluase 408. Using Locally Availablematerial |
| 75 | Water Bound MacadamGrading II-(using Crusher Broken Metal & stone screening) Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smoothwheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. |
| 76 | Reinforced cement concrete M15grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703Ordinary Kilometer Stone (Precast) |
| 77 | Reinforced cement concrete M15grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703200 m stone (precast) |
| 78 | Providing andfixing trap/granite/ quartzite/ gneiss/ guard stone/ indicator stones/ boundry stones of standard size& shape includingfixingIn ground andwashing complete Spec. No.: MORTH 807 |
| 79 | Providing and fixingRetro Reflective MMGSY/PMGSY LOGO informatory sign board with Logo as per section 1700 of MORD specification sand latest PMGSY Signage Manual/Circuler and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600 mm size, rivete dwith MS angle ironframe of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle ironframe of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat ironframe will be done neatly to have plain surface on one side. The angle ironframe of Both the plates will be welded to a 75mmx75mmx12 swg Mild steel post at/Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200 mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY/PMGSY logo, letters and numeral sonthe ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade asper the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo MMGSY Logo Project description on ClassA or ClassB type retroreflective sheeting using modern technology printing plat form. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The in k sused for printing shall be ecofriendly with VOC emissions complying to UL2801 standards and specifications for the different kinds of plat forms. The printe dsign shall be laminated by UV protected laminate and shall carry awarranty of 5 years & 7 years for ClassA and ClassB sheeting respectively for traffic colors.” All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1(B) and as directed by Engineerin-charge. A warranty for 5/7 years for the Retroreflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.(SOR ITEM NO.10.16 ) A) Retro Reflective sheeting class-A |
| 80 | Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4 mmt hick ACP sheet supported with Back support frame of 35x35x5 mm mild steel angle with are as not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm-3.5mt rheight, firmly fixed to the ground by means of properly designed foundation of M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level complete (as per MoRT & H specification No.801) (for area Less than 0.9 sqm). 7 Both border & background shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product offered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. The reshall be as tamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.(Village Name Board) |
| 81 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm equilateral triangular |
| 82 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm circular |
| 83 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting c. 600 x 450 mm Rectangular |
| 84 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting900 x 600milimeter reclangular |
| 85 | MMGSY/PMGSY Citizen\"s information Board-Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specification sand latest PMGSY Sign age Manual/Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35x35x5mm thic kM. Sangle shall be welded by two vertical M.S angle of 5mm thick to 75mmx75mm of 12 SWG square tubes/75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mmx600mmx75mm, below ground level . MMGSY/PMGSY logo, letter sand numer also n the ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade as per the latest MORD section1700 specifications (Refer Circuler no. NRRDA-P 013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo /MMGSY Logo/Project descriptionon ClassA or ClassB type retroreflective sheeting using modern technology printing platform. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The inks used for printing shall bee co friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of plat forms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed post sand steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed |
| 86 | Painting lines, Dashes, Arrows, etc. on Road in Two Coats on New Work,Painting lines, dashes, arrows, etc. on roads in two coatson new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702 SR.NO 10.7 P.NO 42 |
| 87 | Providing and fixing Road junction / Information sign board of size 1.20 m x 1.20 m. prepared on 16 gauge M.S. sheet with angle iron frame of size 35 x 35 x 5 mm with cross bracing of size 35 x 35 x 5 mm including painting with one coat of zinc cromate stoving primer and two coats each of green/white back ground and back side gray stove enamelled, bonded with red retro reflective sheet Engineering grade, border / letters / numeral /arrows, coated with non pealable crystal clear protective transperent coat retaining 100% reflection includingtwo angle iron post of size 65 x 65x 6 mm of 3.65 m.long inflated at bottom drilled on top and painted in whiteand black bands of 30 cm. with 4 Nos. high strength G.I. bolts and nuts of size 10 mm dia. and 20 mm long sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with M-20 cement concrete of 60 cm x 60 cm x 75 cm size as directed by Engineer-in charge etc. complete. Mild Steel sheet with Engineering grade |
| 88 | Road Delineators: Providing and fixing steel pipe delineators of 10 cm. in diameter and total height of 130 cm, provided with 2 strips of white retroreflective sheeting of size 5 cm. x 32.5 cm. each fixed horizontally and 2 strips of red retroreflective sheeting each having size 5 cm. x 32.5 cm. fixed horizontally at top, with M.S. round cap having diameter 11 cm. and wire mesh at top (10 guage thick) and height of wire mesh 15 cm, M.S. hold fast 6 mm thick with 35 cm. in length, fixing the delineators in C.C. 1:4:8 concrete block of size 25 cm. x 25 cm. x 45 cm. with necessary excavation etc. completef. |
| 89 | Construction of Dry Lean Cement Concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to 15: 383, the size of coarse aggregate not exceeding 25 mm., cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing andincluding preparation of sub-grade surface if required etc. complete. |
| 90 | Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolana Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate (VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer In charge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc, complete as per specifications. (Excluding Dowel Bars and Tie Bars) |
| 91 | Providing and fixing in position 25mm dia anti corrosive MS Dowel bars of required Dia.60 cms. Long and at 30.00 cm. C/C and wherever directed including handling. straightening, necessary cutting supported by chairs with proper alignment with half length covered by polyethene sheathing including cap etc. complete. |
| 92 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. |
| 93 | Removing all types of Hume pipes and stackig within a lead of 1000 m including Earthwork and Dismantling of Masonry work as per Technical Specification clause 202- Above 600 to900mm dia. Hume pipe |
| 94 | Laying Reinforced Cement Concrete Pipe NP2 as per design in single row600 MM to 900 MM Dia-Reusable 600 to900mm dia. Hume pipe |
| 95 | Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. Ordinary soil By Mechanical means |
| 96 | Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. Ordinary rock (not requiring blasting) Upto 3 m depth |
| 97 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. ( Hard rock (blasting prohibited) |
| 98 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial.HARD rock (requiring blasting) |
| 99 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802,803, 1202 & 1203P.C.C grade M 10 Nominal mix (1:3:6) |
| 100 | Plain/reinforced cement concrete in sub structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix (1:2.5:5) |
| 101 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 mm NP3 Class As per Technical Specification MORD 2014 Cluase No. 1100 |
| 102 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.600 mm NP3 Pipe |
| 103 | Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106..600 mm NP2 Pipe |
| 104 | Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered/concrete surfaces as per drawing and Technical Specification Clause 1701 |
| 105 | Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701 |
| 106 | Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709, 1204.3.7 A.C. pipe 100 mm Dia |
| 107 | Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W \"metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)\" |
| 108 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. |
| 109 | Providingdryrubble latrite stone masonarywith available material. (lead 50 mt) |
| 110 | Providingdry rubble latrite stone masonary ( including royalty ) (lead 50 mt) |
| 111 | Providing laterite stone masonry in cement mortar 1:6 in super structure including racking out joints when plastering is to be done /striking joints when no plastering is to be done watering and scaffolding |
| 112 | Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600mmwith smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height , compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8 |
| 113 | Backfilling behind abutment, wing wall and return wallwith Granular Material complete as per drawings & technical specification Clause 1204.3.8 |
| 114 | Providing and laying cement concrete wearing course M 30 grade Excluding reinforcementcomplete as per drawing and technical specifications Clauses 800 and 1206.3 |
| 115 | Dewatering including diversion of streame providing coffer dam bunds etc as may be necessary for foundation and other parts of the work and bailling out water during and after excavation required- for Raft |
| 116 | Dewatering including diversion of streame providing coffer dam bunds etc as may be necessary for foundation and other parts of the work and bailling out water during and after excavation required- for return |
| 117 | Plain cement concrete M10 (1:3:6) nominal mix in levelling course below open foundation as per drawing and technical specification. |
| 118 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 PCC M-20 |
| 119 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 PCC M-25 |
| 120 | Filling in foundataion trenches as per detailed drawing and technical specification clause 305.3.9 Sand Filling |
| 121 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204. II. P.C.C. grade M 20 (i) Nominal mix (1:1:5:3) |
| 122 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 P.C.C. grade M-25 |
| 123 | Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5. II. R.C.C M 25 |
| 124 | Supplying, fitting and placingTMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202 |
| 125 | Supplying, fitting, and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 |
| 126 | Supplying ,fitting and placingTMT bar reinforcement (Fe 415)in Superstructure complete as per drawings and technical specification Clauses 1002,1005,1010,and 1202 |
| 127 | Providing Tar paper bearing of approved quality in proper size etc. complete (Rate as per PWDCSR 2020-21) BRItem no.13.02 Pg no 118 |
| 128 | Expansion joint with 25 mm thich bitumenous pad / Compressible Rubber Pad (Rate as per PWDCSR for 2018-19) BR 43B Item no.14.33 pg no.123 |
| 129 | Providing pressure relife pipe 100 mm dia . In bottam slab of box cell on a filtter meadia base of 500 mm x 500 mm as per drawing and technical specification clause 1205.5.7 |
| 130 | Construction Joints Providing and filling joints sealing compound as per drawing and technical specification with corse sand and 6% bitumen by weght |
| 131 | Providingand laying 0.90 meter thick metal mat consisting of rubble, oversize metal and normal size metal in specified thickness as per detailed drawing including supplying all materials, hand packing of rubble, spreading metal in layers and hard murum including watering and compaction with power roller etc. complete. |
| 132 | Providing and fixing in position pipe railing consisting of IS Rolled steel joist posts designation IS MB 100 (100x50) at 2.5 m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and technical specifications Clause 1208.2 |
| 133 | Diversion for bridge |
| 134 | Electric Pole Paintinng- Providing and fixing reflective fluorescent tape on old road sign board including cleaning / scraping and paintingexisting board etc. complete |
| 135 | Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015). |
| 136 | Cat Eye-Supplying & Fixing of Molded Shank Raised Pavement Markers / Cat\"s Eyemade of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer\"s recommendation and complete as directed by the engineer.The contractor shall submit a two year warrantyfor satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer. |
| 137 | Providing and Laying of Rumble strips with Plastirib 2K, or equivalent 2 component cold plastic profiled material to give total width of 500 mm and height of 10 mm. Ramp provided to give width of 145 mm, width of ribs to be 55mm laid at centre to centre distance of 35 mm, with reflective glass beads @ 350 gm / sqm. The finished surface to be levelled, uniform and free from streaks and holes, to be applied on the edge lines, including surface cleaning and cost of all materials etc. complete. |
| 138 | Painting Trees-Providing white and colour washing to road side trees in 2coats in 2 bands of white and one red band at centre of 30 cm height each including preparing the surface, cost of material, conveying etc. complete. |
| 139 | 3.00 Upgradation & Maintenance of RoadFrom MDR 19 to Khudi Deulwadi Panhalwadi Road. Km. 0.000 to 3.100 Km. Tal-Devgad, Dist -Sindhudurg. |
| 140 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (A) In area of Non-thorny jungle |
| 141 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (B) In area of thorny jungle |
| 142 | Excavation for roadwork in soil with hydraulic excavator of0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and croun-sections, and transporting to the embankment location with a lift upto 1.5 m and lead above 1000 m as per Technical Specification MORD 2014 Clause 302.3 |
| 143 | Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead above 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and croun-sections as per Technical Specification MORD 2014 Clause 302.3.5 |
| 144 | Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and croun-sections, loading and disposal of cut rock with a lift upto 1.5 m and with all leadsas per Technical Specification MORD 2014 Clause 302.3.5 |
| 145 | Excavation in Hard Rock (blasting Prohibited) -Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 metre and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5 |
| 146 | Excavation for roadway in hard rockwith controlledblasting by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads upto 1000 mas per Technical Specification Clause 302.3.5 |
| 147 | Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1. |
| 148 | Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical SpecificationClause 301.5 |
| 149 | Construction of embankment with approved material obtained from borrow pits with al ift upto 1.5m, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 |
| 150 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. |
| 151 | Scarifying the existing Bituminous surface to a depth of 150 mm and disposal ofscarified material with a lift up to 3 m and lead upto 1000 mas per technical specificationaClause 301.4 |
| 152 | Construction of Granular Sub baseusing locally available materialProviding, laying spreading and compacting local material in block or large discrete particles, such as kankar, Laterite, Dhandla etc. as per Table 400.13 to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming requisite type of screening /binding materials to fill-up theinterstices of laid material watering and compacting to the required density as per Clause 405.3 and Technical Specification Cluase 408. Using Locally Availablematerial |
| 153 | Water Bound MacadamGrading II-(using Crusher Broken Metal & stone screening) Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smoothwheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. |
| 154 | Reinforced cement concrete M15grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703Ordinary Kilometer Stone (Precast) |
| 155 | Reinforced cement concrete M15grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703200 m stone (precast) |
| 156 | Providing andfixing trap/granite/ quartzite/ gneiss/ guard stone/ indicator stones/ boundry stones of standard size& shape includingfixingIn ground andwashing complete Spec. No.: MORTH 807 |
| 157 | Providing and fixingRetro Reflective MMGSY/PMGSY LOGO informatory sign board with Logo as per section 1700 of MORD specification sand latest PMGSY Signage Manual/Circuler and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600 mm size, rivete dwith MS angle ironframe of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle ironframe of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat ironframe will be done neatly to have plain surface on one side. The angle ironframe of Both the plates will be welded to a 75mmx75mmx12 swg Mild steel post at/Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200 mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY/PMGSY logo, letters and numeral sonthe ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade asper the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo MMGSY Logo Project description on ClassA or ClassB type retroreflective sheeting using modern technology printing plat form. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The in k sused for printing shall be ecofriendly with VOC emissions complying to UL2801 standards and specifications for the different kinds of plat forms. The printe dsign shall be laminated by UV protected laminate and shall carry awarranty of 5 years & 7 years for ClassA and ClassB sheeting respectively for traffic colors.” All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1(B) and as directed by Engineerin-charge. A warranty for 5/7 years for the Retroreflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.(SOR ITEM NO.10.16 ) A) Retro Reflective sheeting class-A |
| 158 | Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4 mmt hick ACP sheet supported with Back support frame of 35x35x5 mm mild steel angle with are as not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm-3.5mt rheight, firmly fixed to the ground by means of properly designed foundation of M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level complete (as per MoRT & H specification No.801) (for area Less than 0.9 sqm). 7 Both border & background shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product offered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. The reshall be as tamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.(Village Name Board) |
| 159 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm equilateral triangular |
| 160 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm circular |
| 161 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting c. 600 x 450 mm Rectangular |
| 162 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting900 x 600milimeter reclangular |
| 163 | MMGSY/PMGSY Citizen\"s information Board-Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specification sand latest PMGSY Sign age Manual/Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35x35x5mm thic kM. Sangle shall be welded by two vertical M.S angle of 5mm thick to 75mmx75mm of 12 SWG square tubes/75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mmx600mmx75mm, below ground level . MMGSY/PMGSY logo, letter sand numer also n the ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade as per the latest MORD section1700 specifications (Refer Circuler no. NRRDA-P 013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo /MMGSY Logo/Project descriptionon ClassA or ClassB type retroreflective sheeting using modern technology printing platform. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The inks used for printing shall bee co friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of plat forms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed post sand steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed |
| 164 | Painting lines, Dashes, Arrows, etc. on Road in Two Coats on New Work,Painting lines, dashes, arrows, etc. on roads in two coatson new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702 SR.NO 10.7 P.NO 42 |
| 165 | Providing and fixing Road junction / Information sign board of size 1.20 m x 1.20 m. prepared on 16 gauge M.S. sheet with angle iron frame of size 35 x 35 x 5 mm with cross bracing of size 35 x 35 x 5 mm including painting with one coat of zinc cromate stoving primer and two coats each of green/white back ground and back side gray stove enamelled, bonded with red retro reflective sheet Engineering grade, border / letters / numeral /arrows, coated with non pealable crystal clear protective transperent coat retaining 100% reflection includingtwo angle iron post of size 65 x 65x 6 mm of 3.65 m.long inflated at bottom drilled on top and painted in whiteand black bands of 30 cm. with 4 Nos. high strength G.I. bolts and nuts of size 10 mm dia. and 20 mm long sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with M-20 cement concrete of 60 cm x 60 cm x 75 cm size as directed by Engineer-in charge etc. complete. Mild Steel sheet with Engineering grade |
| 166 | Road Delineators: Providing and fixing steel pipe delineators of 10 cm. in diameter and total height of 130 cm, provided with 2 strips of white retroreflective sheeting of size 5 cm. x 32.5 cm. each fixed horizontally and 2 strips of red retroreflective sheeting each having size 5 cm. x 32.5 cm. fixed horizontally at top, with M.S. round cap having diameter 11 cm. and wire mesh at top (10 guage thick) and height of wire mesh 15 cm, M.S. hold fast 6 mm thick with 35 cm. in length, fixing the delineators in C.C. 1:4:8 concrete block of size 25 cm. x 25 cm. x 45 cm. with necessary excavation etc. completef. |
| 167 | Construction of Dry Lean Cement Concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to 15: 383, the size of coarse aggregate not exceeding 25 mm., cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing andincluding preparation of sub-grade surface if required etc. complete. |
| 168 | Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolana Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate (VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer In charge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc, complete as per specifications. (Excluding Dowel Bars and Tie Bars) |
| 169 | Providing and fixing in position 25mm dia anti corrosive MS Dowel bars of required Dia.60 cms. Long and at 30.00 cm. C/C and wherever directed including handling. straightening, necessary cutting supported by chairs with proper alignment with half length covered by polyethene sheathing including cap etc. complete. |
| 170 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. |
| 171 | Removing all types of Hume pipes and stackig within a lead of 1000 m including Earthwork and Dismantling of Masonry work as per Technical Specification clause 202- Above 600 to900mm dia. Hume pipe |
| 172 | Laying Reinforced Cement Concrete Pipe NP2 as per design in single row600 MM to 900 MM Dia-Reusable 600 to900mm dia. Hume pipe |
| 173 | Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. Ordinary soil By Mechanical means |
| 174 | Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. Ordinary rock (not requiring blasting) Upto 3 m depth |
| 175 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. ( Hard rock (blasting prohibited) |
| 176 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial.HARD rock (requiring blasting) |
| 177 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802,803, 1202 & 1203P.C.C grade M 10 Nominal mix (1:3:6) |
| 178 | Plain/reinforced cement concrete in sub structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix (1:2.5:5) |
| 179 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 mm NP3 Class As per Technical Specification MORD 2014 Cluase No. 1100 |
| 180 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.600 mm NP3 Pipe |
| 181 | Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106..600 mm NP2 Pipe |
| 182 | Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered/concrete surfaces as per drawing and Technical Specification Clause 1701 |
| 183 | Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701 |
| 184 | Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709, 1204.3.7 A.C. pipe 100 mm Dia |
| 185 | Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W \"metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)\" |
| 186 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. |
| 187 | Providingdryrubble latrite stone masonarywith available material. (lead 50 mt) |
| 188 | Providingdry rubble latrite stone masonary ( including royalty ) (lead 50 mt) |
| 189 | Providing laterite stone masonry in cement mortar 1:6 in super structure including racking out joints when plastering is to be done /striking joints when no plastering is to be done watering and scaffolding |
| 190 | Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600mmwith smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height , compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8 |
| 191 | Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 |
| 192 | Backfilling behind abutment, wing wall and return wallwith Granular Material complete as per drawings & technical specification Clause 1204.3.8 |
| 193 | Providing and laying cement concrete wearing course M 30 grade Excluding reinforcementcomplete as per drawing and technical specifications Clauses 800 and 1206.3 |
| 194 | Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 |
| 195 | Providing and fixing in position pipe railing consisting of IS Rolled steel joist posts designation IS MB 100 (100x50) at 2.5 m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and technical specifications Clause 1208.2 |
| 196 | Electric Pole Paintinng- Providing and fixing reflective fluorescent tape on old road sign board including cleaning / scraping and paintingexisting board etc. complete |
| 197 | Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015). |
| 198 | Cat Eye-Supplying & Fixing of Molded Shank Raised Pavement Markers / Cat\"s Eyemade of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer\"s recommendation and complete as directed by the engineer.The contractor shall submit a two year warrantyfor satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer. |
| 199 | Providing and Laying of Rumble strips with Plastirib 2K, or equivalent 2 component cold plastic profiled material to give total width of 500 mm and height of 10 mm. Ramp provided to give width of 145 mm, width of ribs to be 55mm laid at centre to centre distance of 35 mm, with reflective glass beads @ 350 gm / sqm. The finished surface to be levelled, uniform and free from streaks and holes, to be applied on the edge lines, including surface cleaning and cost of all materials etc. complete. |
| 200 | Painting Trees-Providing white and colour washing to road side trees in 2coats in 2 bands of white and one red band at centre of 30 cm height each including preparing the surface, cost of material, conveying etc. complete. |
| 201 | 4.00 Upgradation & Maintenance of RoadFrom MDR 9 to Ombal Navalewadi Kazarwadi to ODR 13 Road. Km. 0.000 to 3.050 Km. Tal-Devgad, Dist -Sindhudurg. |
| 202 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (A) In area of Non-thorny jungle |
| 203 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (B) In area of thorny jungle |
| 204 | Excavation for roadwork in soil with hydraulic excavator of0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and croun-sections, and transporting to the embankment location with a lift upto 1.5 m and lead above 1000 m as per Technical Specification MORD 2014 Clause 302.3 |
| 205 | Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead above 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and croun-sections as per Technical Specification MORD 2014 Clause 302.3.5 |
| 206 | Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and croun-sections, loading and disposal of cut rock with a lift upto 1.5 m and with all leadsas per Technical Specification MORD 2014 Clause 302.3.5 |
| 207 | Excavation in Hard Rock (blasting Prohibited) -Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 metre and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5 |
| 208 | Excavation for roadway in hard rockwith controlledblasting by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads upto 1000 mas per Technical Specification Clause 302.3.5 |
| 209 | Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1. |
| 210 | Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical SpecificationClause 301.5 |
| 211 | Construction of embankment with approved material obtained from borrow pits with al ift upto 1.5m, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 |
| 212 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. |
| 213 | Scarifying the existing Bituminous surface to a depth of 150 mm and disposal ofscarified material with a lift up to 3 m and lead upto 1000 mas per technical specificationaClause 301.4 |
| 214 | Construction of Granular Sub baseusing locally available materialProviding, laying spreading and compacting local material in block or large discrete particles, such as kankar, Laterite, Dhandla etc. as per Table 400.13 to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming requisite type of screening /binding materials to fill-up theinterstices of laid material watering and compacting to the required density as per Clause 405.3 and Technical Specification Cluase 408. Using Locally Availablematerial |
| 215 | Water Bound MacadamGrading II-(using Crusher Broken Metal & stone screening) Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smoothwheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. |
| 216 | Reinforced cement concrete M15grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703Ordinary Kilometer Stone (Precast) |
| 217 | Reinforced cement concrete M15grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703200 m stone (precast) |
| 218 | Providing andfixing trap/granite/ quartzite/ gneiss/ guard stone/ indicator stones/ boundry stones of standard size& shape includingfixingIn ground andwashing complete Spec. No.: MORTH 807 |
| 219 | Providing and fixingRetro Reflective MMGSY/PMGSY LOGO informatory sign board with Logo as per section 1700 of MORD specification sand latest PMGSY Signage Manual/Circuler and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600 mm size, rivete dwith MS angle ironframe of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle ironframe of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat ironframe will be done neatly to have plain surface on one side. The angle ironframe of Both the plates will be welded to a 75mmx75mmx12 swg Mild steel post at/Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200 mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY/PMGSY logo, letters and numeral sonthe ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade asper the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo MMGSY Logo Project description on ClassA or ClassB type retroreflective sheeting using modern technology printing plat form. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The in k sused for printing shall be ecofriendly with VOC emissions complying to UL2801 standards and specifications for the different kinds of plat forms. The printe dsign shall be laminated by UV protected laminate and shall carry awarranty of 5 years & 7 years for ClassA and ClassB sheeting respectively for traffic colors.” All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1(B) and as directed by Engineerin-charge. A warranty for 5/7 years for the Retroreflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.(SOR ITEM NO.10.16 ) A) Retro Reflective sheeting class-A |
| 220 | Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4 mmt hick ACP sheet supported with Back support frame of 35x35x5 mm mild steel angle with are as not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm-3.5mt rheight, firmly fixed to the ground by means of properly designed foundation of M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level complete (as per MoRT & H specification No.801) (for area Less than 0.9 sqm). 7 Both border & background shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product offered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. The reshall be as tamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.(Village Name Board) |
| 221 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm equilateral triangular |
| 222 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm circular |
| 223 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting c. 600 x 450 mm Rectangular |
| 224 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting900 x 600milimeter reclangular |
| 225 | MMGSY/PMGSY Citizen\"s information Board-Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specification sand latest PMGSY Sign age Manual/Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35x35x5mm thic kM. Sangle shall be welded by two vertical M.S angle of 5mm thick to 75mmx75mm of 12 SWG square tubes/75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mmx600mmx75mm, below ground level . MMGSY/PMGSY logo, letter sand numer also n the ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade as per the latest MORD section1700 specifications (Refer Circuler no. NRRDA-P 013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo /MMGSY Logo/Project descriptionon ClassA or ClassB type retroreflective sheeting using modern technology printing platform. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The inks used for printing shall bee co friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of plat forms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed post sand steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed |
| 226 | Painting lines, Dashes, Arrows, etc. on Road in Two Coats on New Work,Painting lines, dashes, arrows, etc. on roads in two coatson new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702 SR.NO 10.7 P.NO 42 |
| 227 | Providing and fixing Road junction / Information sign board of size 1.20 m x 1.20 m. prepared on 16 gauge M.S. sheet with angle iron frame of size 35 x 35 x 5 mm with cross bracing of size 35 x 35 x 5 mm including painting with one coat of zinc cromate stoving primer and two coats each of green/white back ground and back side gray stove enamelled, bonded with red retro reflective sheet Engineering grade, border / letters / numeral /arrows, coated with non pealable crystal clear protective transperent coat retaining 100% reflection includingtwo angle iron post of size 65 x 65x 6 mm of 3.65 m.long inflated at bottom drilled on top and painted in whiteand black bands of 30 cm. with 4 Nos. high strength G.I. bolts and nuts of size 10 mm dia. and 20 mm long sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with M-20 cement concrete of 60 cm x 60 cm x 75 cm size as directed by Engineer-in charge etc. complete. Mild Steel sheet with Engineering grade |
| 228 | Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings |
| 229 | Construction of Dry Lean Cement Concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to 15: 383, the size of coarse aggregate not exceeding 25 mm., cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing andincluding preparation of sub-grade surface if required etc. complete. |
| 230 | Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolana Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate (VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer In charge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc, complete as per specifications. (Excluding Dowel Bars and Tie Bars) |
| 231 | Providing and fixing in position 25mm dia anti corrosive MS Dowel bars of required Dia.60 cms. Long and at 30.00 cm. C/C and wherever directed including handling. straightening, necessary cutting supported by chairs with proper alignment with half length covered by polyethene sheathing including cap etc. complete. |
| 232 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. |
| 233 | Removing all types of Hume pipes and stackig within a lead of 1000 m including Earthwork and Dismantling of Masonry work as per Technical Specification clause 202- Above 600 to900mm dia. Hume pipe |
| 234 | Laying Reinforced Cement Concrete Pipe NP2 as per design in single row600 MM to 900 MM Dia-Reusable 600 to900mm dia. Hume pipe |
| 235 | Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. Ordinary soil By Mechanical means |
| 236 | Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. Ordinary rock (not requiring blasting) Upto 3 m depth |
| 237 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. ( Hard rock (blasting prohibited) |
| 238 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial.HARD rock (requiring blasting) |
| 239 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802,803, 1202 & 1203P.C.C grade M 10 Nominal mix (1:3:6) |
| 240 | Plain/reinforced cement concrete in sub structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix (1:2.5:5) |
| 241 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 mm NP3 Class As per Technical Specification MORD 2014 Cluase No. 1100 |
| 242 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.600 mm NP3 Pipe |
| 243 | Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106..600 mm NP2 Pipe |
| 244 | Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered/concrete surfaces as per drawing and Technical Specification Clause 1701 |
| 245 | Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701 |
| 246 | Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709, 1204.3.7 A.C. pipe 100 mm Dia |
| 247 | Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W \"metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)\" |
| 248 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. |
| 249 | Providingdryrubble latrite stone masonarywith available material. (lead 50 mt) |
| 250 | Providingdry rubble latrite stone masonary ( including royalty ) (lead 50 mt) |
| 251 | Providing laterite stone masonry in cement mortar 1:6 in super structure including racking out joints when plastering is to be done /striking joints when no plastering is to be done watering and scaffolding |
| 252 | Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600mmwith smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height , compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8 |
| 253 | Backfilling behind abutment, wing wall and return wallwith Granular Material complete as per drawings & technical specification Clause 1204.3.8 |
| 254 | Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 |
| 255 | Electric Pole Paintinng- Providing and fixing reflective fluorescent tape on old road sign board including cleaning / scraping and paintingexisting board etc. complete |
| 256 | Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015). |
| 257 | Cat Eye-Supplying & Fixing of Molded Shank Raised Pavement Markers / Cat\"s Eyemade of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer\"s recommendation and complete as directed by the engineer.The contractor shall submit a two year warrantyfor satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer. |
| 258 | Providing and Laying of Rumble strips with Plastirib 2K, or equivalent 2 component cold plastic profiled material to give total width of 500 mm and height of 10 mm. Ramp provided to give width of 145 mm, width of ribs to be 55mm laid at centre to centre distance of 35 mm, with reflective glass beads @ 350 gm / sqm. The finished surface to be levelled, uniform and free from streaks and holes, to be applied on the edge lines, including surface cleaning and cost of all materials etc. complete. |
| 259 | Painting Trees-Providing white and colour washing to road side trees in 2coats in 2 bands of white and one red band at centre of 30 cm height each including preparing the surface, cost of material, conveying etc. complete. |
| 260 | 5.00 -Upgradation & Maintenance of RoadFrom MDR 25 To Shivdav Gavkarwadi Boudhwadi to ODR 27Road . Km. 0.000 to 3.850 Km. Tal-Kanakavali, Dist -Sindhudurg. |
| 261 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (A) In area of Non-thorny jungle |
| 262 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (B) In area of thorny jungle |
| 263 | Excavation for roadwork in soil with hydraulic excavator of0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and croun-sections, and transporting to the embankment location with a lift upto 1.5 m and lead above 1000 m as per Technical Specification MORD 2014 Clause 302.3 |
| 264 | Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead above 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and croun-sections as per Technical Specification MORD 2014 Clause 302.3.5 |
| 265 | Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and croun-sections, loading and disposal of cut rock with a lift upto 1.5 m and with all leadsas per Technical Specification MORD 2014 Clause 302.3.5 |
| 266 | Excavation in Hard Rock (blasting Prohibited) -Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 metre and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5 |
| 267 | Excavation in Hard Rock (Controlled Blasting) -Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 metre and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5 |
| 268 | Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1. |
| 269 | Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical SpecificationClause 301.5 |
| 270 | Construction of embankment with approved material obtained from borrow pits with al ift upto 1.5m, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 |
| 271 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. |
| 272 | Scarifying the existing Bituminous surface to a depth of 150 mm and disposal ofscarified material with a lift up to 3 m and lead upto 1000 mas per technical specificationaClause 301.4 |
| 273 | Construction of Granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavatorat OMC, and compacting with smoothwheelroller to achieve thedesired density, complete as per Technical SpecificationClause 401. For Grading I material by mix in Place Method |
| 274 | Water Bound MacadamGrading II-(using Crusher Broken Metal & stone screening) Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smoothwheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. |
| 275 | Wet Mix Macadam (WMM) Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing thematerial with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, layingin uniform layers in sub-base/base course on a well prepared sub-base and compacting with smoothwheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. |
| 276 | Reinforced cement concrete M15grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703Ordinary Kilometer Stone (Precast) |
| 277 | Reinforced cement concrete M15grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703200 m stone (precast) |
| 278 | Providing andfixing trap/granite/ quartzite/ gneiss/ guard stone/ indicator stones/ boundry stones of standard size& shape includingfixingIn ground andwashing complete Spec. No.: MORTH 807 |
| 279 | Providing and fixingRetro Reflective MMGSY/PMGSY LOGO informatory sign board with Logo as per section 1700 of MORD specification sand latest PMGSY Signage Manual/Circuler and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600 mm size, rivete dwith MS angle ironframe of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle ironframe of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat ironframe will be done neatly to have plain surface on one side. The angle ironframe of Both the plates will be welded to a 75mmx75mmx12 swg Mild steel post at/Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200 mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY/PMGSY logo, letters and numeral sonthe ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade asper the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo MMGSY Logo Project description on ClassA or ClassB type retroreflective sheeting using modern technology printing plat form. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The in k sused for printing shall be ecofriendly with VOC emissions complying to UL2801 standards and specifications for the different kinds of plat forms. The printe dsign shall be laminated by UV protected laminate and shall carry awarranty of 5 years & 7 years for ClassA and ClassB sheeting respectively for traffic colors.” All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1(B) and as directed by Engineerin-charge. A warranty for 5/7 years for the Retroreflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.(SOR ITEM NO.10.16 ) A) Retro Reflective sheeting class-A |
| 280 | Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4 mmt hick ACP sheet supported with Back support frame of 35x35x5 mm mild steel angle with are as not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm-3.5mt rheight, firmly fixed to the ground by means of properly designed foundation of M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level complete (as per MoRT & H specification No.801) (for area Less than 0.9 sqm). 7 Both border & background shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product offered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. The reshall be as tamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.(Village Name Board) |
| 281 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm equilateral triangular |
| 282 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm circular |
| 283 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting c. 600 x 450 mm Rectangular |
| 284 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting900 x 600milimeter reclangular |
| 285 | MMGSY/PMGSY Citizen\"s information Board-Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specification sand latest PMGSY Sign age Manual/Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35x35x5mm thic kM. Sangle shall be welded by two vertical M.S angle of 5mm thick to 75mmx75mm of 12 SWG square tubes/75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mmx600mmx75mm, below ground level . MMGSY/PMGSY logo, letter sand numer also n the ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade as per the latest MORD section1700 specifications (Refer Circuler no. NRRDA-P 013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo /MMGSY Logo/Project descriptionon ClassA or ClassB type retroreflective sheeting using modern technology printing platform. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The inks used for printing shall bee co friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of plat forms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed post sand steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed |
| 286 | Painting lines, Dashes, Arrows, etc. on Road in Two Coats on New Work,Painting lines, dashes, arrows, etc. on roads in two coatson new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702 SR.NO 10.7 P.NO 42 |
| 287 | Providing and fixing Road junction / Information sign board of size 1.20 m x 1.20 m. prepared on 16 gauge M.S. sheet with angle iron frame of size 35 x 35 x 5 mm with cross bracing of size 35 x 35 x 5 mm including painting with one coat of zinc cromate stoving primer and two coats each of green/white back ground and back side gray stove enamelled, bonded with red retro reflective sheet Engineering grade, border / letters / numeral /arrows, coated with non pealable crystal clear protective transperent coat retaining 100% reflection includingtwo angle iron post of size 65 x 65x 6 mm of 3.65 m.long inflated at bottom drilled on top and painted in whiteand black bands of 30 cm. with 4 Nos. high strength G.I. bolts and nuts of size 10 mm dia. and 20 mm long sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with M-20 cement concrete of 60 cm x 60 cm x 75 cm size as directed by Engineer-in charge etc. complete. Mild Steel sheet with Engineering grade |
| 288 | Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazardmarkers, Object markers) 80 to 100 cm high above ground level, painted black and whitein 15 cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circularreflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C.79 and the drawings |
| 289 | Construction of Dry Lean Cement Concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to 15: 383, the size of coarse aggregate not exceeding 25 mm., cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing andincluding preparation of sub-grade surface if required etc. complete. |
| 290 | Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolana Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate (VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer In charge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc, complete as per specifications. (Excluding Dowel Bars and Tie Bars) |
| 291 | Providing and fixing in position anticorrosive TMT FE 500 Tie bars of 12 mm día. 70 cms. long and at 30.00 cm. C/C and wherever directed including handling, straightening. necessary cutting, handling, straightening, supported by assembly of TMT FE 500, chairs with proper alignment etc. complete |
| 292 | Providing and fixing in position 25mm dia anti corrosive MS Dowel bars of required Dia.60 cms. Long and at 30.00 cm. C/C and wherever directed including handling. straightening, necessary cutting supported by chairs with proper alignment with half length covered by polyethene sheathing including cap etc. complete. |
| 293 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. |
| 294 | Removing all types of Hume pipes and stackig within a lead of 1000 m including Earthwork and Dismantling of Masonry work as per Technical Specification clause 202- Above 600 to900mm dia. Hume pipe |
| 295 | Laying Reinforced Cement Concrete Pipe NP2 as per design in single row600 MM to 900 MM Dia-Reusable 600 to900mm dia. Hume pipe |
| 296 | Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. Ordinary soil By Mechanical means |
| 297 | Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. Ordinary rock (not requiring blasting) Upto 3 m depth |
| 298 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. ( Hard rock (blasting prohibited) |
| 299 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial.HARD rock (requiring blasting) |
| 300 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802,803, 1202 & 1203P.C.C grade M 10 Nominal mix (1:3:6) |
| 301 | Plain/reinforced cement concrete in sub structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix (1:2.5:5) |
| 302 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 mm NP3 Class As per Technical Specification MORD 2014 Cluase No. 1100 |
| 303 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.600 mm NP3 Pipe |
| 304 | Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106..600 mm NP2 Pipe |
| 305 | Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered/concrete surfaces as per drawing and Technical Specification Clause 1701 |
| 306 | Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701 |
| 307 | Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709, 1204.3.7 A.C. pipe 100 mm Dia |
| 308 | Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W \"metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)\" |
| 309 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. |
| 310 | Providingdryrubble latrite stone masonarywith available material. (lead 50 mt) |
| 311 | Providingdry rubble latrite stone masonary ( including royalty ) (lead 50 mt) |
| 312 | Providing laterite stone masonry in cement mortar 1:6 in super structure including racking out joints when plastering is to be done /striking joints when no plastering is to be done watering and scaffolding |
| 313 | Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600mmwith smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height , compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8 |
| 314 | Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 |
| 315 | Backfilling behind abutment, wing wall and return wallwith Granular Material complete as per drawings & technical specification Clause 1204.3.8 |
| 316 | Providing and laying cement concrete wearing course M 30 grade Excluding reinforcementcomplete as per drawing and technical specifications Clauses 800 and 1206.3 |
| 317 | Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 |
| 318 | Electric Pole Paintinng- Providing and fixing reflective fluorescent tape on old road sign board including cleaning / scraping and paintingexisting board etc. complete |
| 319 | Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015). |
| 320 | Cat Eye-Supplying & Fixing of Molded Shank Raised Pavement Markers / Cat\"s Eyemade of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer\"s recommendation and complete as directed by the engineer.The contractor shall submit a two year warrantyfor satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer. |
| 321 | Providing and Laying of Rumble strips with Plastirib 2K, or equivalent 2 component cold plastic profiled material to give total width of 500 mm and height of 10 mm. Ramp provided to give width of 145 mm, width of ribs to be 55mm laid at centre to centre distance of 35 mm, with reflective glass beads @ 350 gm / sqm. The finished surface to be levelled, uniform and free from streaks and holes, to be applied on the edge lines, including surface cleaning and cost of all materials etc. complete. |
| 322 | Painting Trees-Providing white and colour washing to road side trees in 2coats in 2 bands of white and one red band at centre of 30 cm height each including preparing the surface, cost of material, conveying etc. complete. |
| 323 | 6.00 -Upgradation & Maintenance of RoadFrom SH-181 To Harkul to Hulewadi Road . Km. 0.000 to 4.310 Km. Tal-Kanakavali, Dist -Sindhudurg. |
| 324 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (A) In area of Non-thorny jungle |
| 325 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (B) In area of thorny jungle |
| 326 | Excavation for roadwork in soil with hydraulic excavator of0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and croun-sections, and transporting to the embankment location with a lift upto 1.5 m and lead above 1000 m as per Technical Specification MORD 2014 Clause 302.3 |
| 327 | Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead above 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and croun-sections as per Technical Specification MORD 2014 Clause 302.3.5 |
| 328 | Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and croun-sections, loading and disposal of cut rock with a lift upto 1.5 m and with all leadsas per Technical Specification MORD 2014 Clause 302.3.5 |
| 329 | Excavation in Hard Rock (blasting Prohibited) -Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 metre and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5 |
| 330 | Excavation in Hard Rock (Controlled Blasting) -Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 metre and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5 |
| 331 | Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical SpecificationClause 301.5 |
| 332 | Construction of embankment with approved material obtained from borrow pits with al ift upto 1.5m, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 |
| 333 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. |
| 334 | Scarifying the existing Bituminous surface to a depth of 150 mm and disposal ofscarified material with a lift up to 3 m and lead upto 1000 mas per technical specificationaClause 301.4 |
| 335 | Construction of Granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavatorat OMC, and compacting with smoothwheelroller to achieve thedesired density, complete as per Technical SpecificationClause 401. For Grading I material by mix in Place Method |
| 336 | Water Bound MacadamGrading II-(using Crusher Broken Metal & stone screening) Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smoothwheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. |
| 337 | Wet Mix Macadam (WMM) Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing thematerial with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, layingin uniform layers in sub-base/base course on a well prepared sub-base and compacting with smoothwheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. |
| 338 | Reinforced cement concrete M15grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703Ordinary Kilometer Stone (Precast) |
| 339 | Reinforced cement concrete M15grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703200 m stone (precast) |
| 340 | Providing andfixing trap/granite/ quartzite/ gneiss/ guard stone/ indicator stones/ boundry stones of standard size& shape includingfixingIn ground andwashing complete Spec. No.: MORTH 807 |
| 341 | Providing and fixingRetro Reflective MMGSY/PMGSY LOGO informatory sign board with Logo as per section 1700 of MORD specification sand latest PMGSY Signage Manual/Circuler and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600 mm size, rivete dwith MS angle ironframe of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle ironframe of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat ironframe will be done neatly to have plain surface on one side. The angle ironframe of Both the plates will be welded to a 75mmx75mmx12 swg Mild steel post at/Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200 mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY/PMGSY logo, letters and numeral sonthe ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade asper the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo MMGSY Logo Project description on ClassA or ClassB type retroreflective sheeting using modern technology printing plat form. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The in k sused for printing shall be ecofriendly with VOC emissions complying to UL2801 standards and specifications for the different kinds of plat forms. The printe dsign shall be laminated by UV protected laminate and shall carry awarranty of 5 years & 7 years for ClassA and ClassB sheeting respectively for traffic colors.” All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1(B) and as directed by Engineerin-charge. A warranty for 5/7 years for the Retroreflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.(SOR ITEM NO.10.16 ) A) Retro Reflective sheeting class-A |
| 342 | Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4 mmt hick ACP sheet supported with Back support frame of 35x35x5 mm mild steel angle with are as not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm-3.5mt rheight, firmly fixed to the ground by means of properly designed foundation of M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level complete (as per MoRT & H specification No.801) (for area Less than 0.9 sqm). 7 Both border & background shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product offered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. The reshall be as tamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.(Village Name Board) |
| 343 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm equilateral triangular |
| 344 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm circular |
| 345 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting c. 600 x 450 mm Rectangular |
| 346 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting900 x 600milimeter reclangular |
| 347 | MMGSY/PMGSY Citizen\"s information Board-Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specification sand latest PMGSY Sign age Manual/Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35x35x5mm thic kM. Sangle shall be welded by two vertical M.S angle of 5mm thick to 75mmx75mm of 12 SWG square tubes/75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mmx600mmx75mm, below ground level . MMGSY/PMGSY logo, letter sand numer also n the ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade as per the latest MORD section1700 specifications (Refer Circuler no. NRRDA-P 013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo /MMGSY Logo/Project descriptionon ClassA or ClassB type retroreflective sheeting using modern technology printing platform. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The inks used for printing shall bee co friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of plat forms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed post sand steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed |
| 348 | Painting lines, Dashes, Arrows, etc. on Road in Two Coats on New Work,Painting lines, dashes, arrows, etc. on roads in two coatson new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702 SR.NO 10.7 P.NO 42 |
| 349 | Providing and fixing Road junction / Information sign board of size 1.20 m x 1.20 m. prepared on 16 gauge M.S. sheet with angle iron frame of size 35 x 35 x 5 mm with cross bracing of size 35 x 35 x 5 mm including painting with one coat of zinc cromate stoving primer and two coats each of green/white back ground and back side gray stove enamelled, bonded with red retro reflective sheet Engineering grade, border / letters / numeral /arrows, coated with non pealable crystal clear protective transperent coat retaining 100% reflection includingtwo angle iron post of size 65 x 65x 6 mm of 3.65 m.long inflated at bottom drilled on top and painted in whiteand black bands of 30 cm. with 4 Nos. high strength G.I. bolts and nuts of size 10 mm dia. and 20 mm long sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with M-20 cement concrete of 60 cm x 60 cm x 75 cm size as directed by Engineer-in charge etc. complete. Mild Steel sheet with Engineering grade |
| 350 | Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazardmarkers, Object markers) 80 to 100 cm high above ground level, painted black and whitein 15 cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circularreflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C.79 and the drawings |
| 351 | Construction of Dry Lean Cement Concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to 15: 383, the size of coarse aggregate not exceeding 25 mm., cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing andincluding preparation of sub-grade surface if required etc. complete. |
| 352 | Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolana Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate (VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer In charge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc, complete as per specifications. (Excluding Dowel Bars and Tie Bars) |
| 353 | Providing and fixing in position 25mm dia anti corrosive MS Dowel bars of required Dia.60 cms. Long and at 30.00 cm. C/C and wherever directed including handling. straightening, necessary cutting supported by chairs with proper alignment with half length covered by polyethene sheathing including cap etc. complete. |
| 354 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. |
| 355 | Removing all types of Hume pipes and stackig within a lead of 1000 m including Earthwork and Dismantling of Masonry work as per Technical Specification clause 202- Above 600 to900mm dia. Hume pipe |
| 356 | Laying Reinforced Cement Concrete Pipe NP2 as per design in single row600 MM to 900 MM Dia-Reusable 600 to900mm dia. Hume pipe |
| 357 | Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. Ordinary soil By Mechanical means |
| 358 | Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. Ordinary rock (not requiring blasting) Upto 3 m depth |
| 359 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. ( Hard rock (blasting prohibited) |
| 360 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial.HARD rock (requiring blasting) |
| 361 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802,803, 1202 & 1203P.C.C grade M 10 Nominal mix (1:3:6) |
| 362 | Plain/reinforced cement concrete in sub structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix (1:2.5:5) |
| 363 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 mm NP3 Class As per Technical Specification MORD 2014 Cluase No. 1100 |
| 364 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.600 mm NP3 Pipe |
| 365 | Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106..600 mm NP2 Pipe |
| 366 | Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered/concrete surfaces as per drawing and Technical Specification Clause 1701 |
| 367 | Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701 |
| 368 | Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709, 1204.3.7 A.C. pipe 100 mm Dia |
| 369 | Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W \"metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)\" |
| 370 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. |
| 371 | Providingdryrubble latrite stone masonarywith available material. (lead 50 mt) |
| 372 | Providingdry rubble latrite stone masonary ( including royalty ) (lead 50 mt) |
| 373 | Providing laterite stone masonry in cement mortar 1:6 in super structure including racking out joints when plastering is to be done /striking joints when no plastering is to be done watering and scaffolding |
| 374 | Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600mmwith smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height , compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8 |
| 375 | Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 |
| 376 | Backfilling behind abutment, wing wall and return wallwith Granular Material complete as per drawings & technical specification Clause 1204.3.8 |
| 377 | Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 |
| 378 | Providing and fixing in position pipe railing consisting of IS Rolled steel joist posts designation IS MB 100 (100x50) at 2.5 m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and technical specifications Clause 1208.2 |
| 379 | Electric Pole Paintinng- Providing and fixing reflective fluorescent tape on old road sign board including cleaning / scraping and paintingexisting board etc. complete |
| 380 | Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015). |
| 381 | Cat Eye-Supplying & Fixing of Molded Shank Raised Pavement Markers / Cat\"s Eyemade of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer\"s recommendation and complete as directed by the engineer.The contractor shall submit a two year warrantyfor satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer. |
| 382 | Providing and Laying of Rumble strips with Plastirib 2K, or equivalent 2 component cold plastic profiled material to give total width of 500 mm and height of 10 mm. Ramp provided to give width of 145 mm, width of ribs to be 55mm laid at centre to centre distance of 35 mm, with reflective glass beads @ 350 gm / sqm. The finished surface to be levelled, uniform and free from streaks and holes, to be applied on the edge lines, including surface cleaning and cost of all materials etc. complete. |
| 383 | Painting Trees-Providing white and colour washing to road side trees in 2coats in 2 bands of white and one red band at centre of 30 cm height each including preparing the surface, cost of material, conveying etc. complete. |
| 384 | 7.00 -Upgradation & Maintenance of RoadFrom Talere Bajarpeth to Gangeshwar toDarum-Gawadewadi-Bhogadewadi Road . Km. 0.000 to 4.000 Km. Tal-Kanakavali, Dist -Sindhudurg. |
| 385 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (A) In area of Non-thorny jungle |
| 386 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (B) In area of thorny jungle |
| 387 | Excavation for roadwork in soil with hydraulic excavator of0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and croun-sections, and transporting to the embankment location with a lift upto 1.5 m and lead above 1000 m as per Technical Specification MORD 2014 Clause 302.3 |
| 388 | Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead above 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and croun-sections as per Technical Specification MORD 2014 Clause 302.3.5 |
| 389 | Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and croun-sections, loading and disposal of cut rock with a lift upto 1.5 m and with all leadsas per Technical Specification MORD 2014 Clause 302.3.5 |
| 390 | Excavation in Hard Rock (blasting Prohibited) -Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 metre and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5 |
| 391 | Excavation in Hard Rock (Controlled Blasting) -Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 metre and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5 |
| 392 | Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1. |
| 393 | Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical SpecificationClause 301.5 |
| 394 | Construction of embankment with approved material obtained from borrow pits with al ift upto 1.5m, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 |
| 395 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. |
| 396 | Scarifying the existing Bituminous surface to a depth of 150 mm and disposal ofscarified material with a lift up to 3 m and lead upto 1000 mas per technical specificationaClause 301.4 |
| 397 | Construction of Granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavatorat OMC, and compacting with smoothwheelroller to achieve thedesired density, complete as per Technical SpecificationClause 401. For Grading I material by mix in Place Method |
| 398 | Water Bound MacadamGrading II-(using Crusher Broken Metal & stone screening) Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smoothwheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. |
| 399 | Reinforced cement concrete M15grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703Ordinary Kilometer Stone (Precast) |
| 400 | Reinforced cement concrete M15grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703200 m stone (precast) |
| 401 | Providing andfixing trap/granite/ quartzite/ gneiss/ guard stone/ indicator stones/ boundry stones of standard size& shape includingfixingIn ground andwashing complete Spec. No.: MORTH 807 |
| 402 | Providing and fixingRetro Reflective MMGSY/PMGSY LOGO informatory sign board with Logo as per section 1700 of MORD specification sand latest PMGSY Signage Manual/Circuler and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600 mm size, rivete dwith MS angle ironframe of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle ironframe of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat ironframe will be done neatly to have plain surface on one side. The angle ironframe of Both the plates will be welded to a 75mmx75mmx12 swg Mild steel post at/Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200 mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY/PMGSY logo, letters and numeral sonthe ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade asper the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo MMGSY Logo Project description on ClassA or ClassB type retroreflective sheeting using modern technology printing plat form. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The in k sused for printing shall be ecofriendly with VOC emissions complying to UL2801 standards and specifications for the different kinds of plat forms. The printe dsign shall be laminated by UV protected laminate and shall carry awarranty of 5 years & 7 years for ClassA and ClassB sheeting respectively for traffic colors.” All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1(B) and as directed by Engineerin-charge. A warranty for 5/7 years for the Retroreflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.(SOR ITEM NO.10.16 ) A) Retro Reflective sheeting class-A |
| 403 | Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4 mmt hick ACP sheet supported with Back support frame of 35x35x5 mm mild steel angle with are as not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm-3.5mt rheight, firmly fixed to the ground by means of properly designed foundation of M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level complete (as per MoRT & H specification No.801) (for area Less than 0.9 sqm). 7 Both border & background shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product offered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. The reshall be as tamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.(Village Name Board) |
| 404 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm equilateral triangular |
| 405 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm circular |
| 406 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting c. 600 x 450 mm Rectangular |
| 407 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting900 x 600milimeter reclangular |
| 408 | MMGSY/PMGSY Citizen\"s information Board-Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specification sand latest PMGSY Sign age Manual/Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35x35x5mm thic kM. Sangle shall be welded by two vertical M.S angle of 5mm thick to 75mmx75mm of 12 SWG square tubes/75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mmx600mmx75mm, below ground level . MMGSY/PMGSY logo, letter sand numer also n the ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade as per the latest MORD section1700 specifications (Refer Circuler no. NRRDA-P 013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo /MMGSY Logo/Project descriptionon ClassA or ClassB type retroreflective sheeting using modern technology printing platform. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The inks used for printing shall bee co friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of plat forms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed post sand steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed |
| 409 | Painting lines, Dashes, Arrows, etc. on Road in Two Coats on New Work,Painting lines, dashes, arrows, etc. on roads in two coatson new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702 SR.NO 10.7 P.NO 42 |
| 410 | Providing and fixing Road junction / Information sign board of size 1.20 m x 1.20 m. prepared on 16 gauge M.S. sheet with angle iron frame of size 35 x 35 x 5 mm with cross bracing of size 35 x 35 x 5 mm including painting with one coat of zinc cromate stoving primer and two coats each of green/white back ground and back side gray stove enamelled, bonded with red retro reflective sheet Engineering grade, border / letters / numeral /arrows, coated with non pealable crystal clear protective transperent coat retaining 100% reflection includingtwo angle iron post of size 65 x 65x 6 mm of 3.65 m.long inflated at bottom drilled on top and painted in whiteand black bands of 30 cm. with 4 Nos. high strength G.I. bolts and nuts of size 10 mm dia. and 20 mm long sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with M-20 cement concrete of 60 cm x 60 cm x 75 cm size as directed by Engineer-in charge etc. complete. Mild Steel sheet with Engineering grade |
| 411 | Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazardmarkers, Object markers) 80 to 100 cm high above ground level, painted black and whitein 15 cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circularreflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C.79 and the drawings |
| 412 | Construction of Dry Lean Cement Concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to 15: 383, the size of coarse aggregate not exceeding 25 mm., cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing andincluding preparation of sub-grade surface if required etc. complete. |
| 413 | Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolana Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate (VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer In charge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc, complete as per specifications. (Excluding Dowel Bars and Tie Bars) |
| 414 | Providing and fixing in position 25mm dia anti corrosive MS Dowel bars of required Dia.60 cms. Long and at 30.00 cm. C/C and wherever directed including handling. straightening, necessary cutting supported by chairs with proper alignment with half length covered by polyethene sheathing including cap etc. complete. |
| 415 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. |
| 416 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. |
| 417 | Removing all types of Hume pipes and stackig within a lead of 1000 m including Earthwork and Dismantling of Masonry work as per Technical Specification clause 202- Above 600 to900mm dia. Hume pipe |
| 418 | Removing all types of Hume pipes and stackig within a lead of 1000 m including Earthwork and Dismantling of Masonry work as per Technical Specification clause 202- Above 900 mm dia. Hume pipe |
| 419 | Laying Reinforced Cement Concrete Pipe NP2 as per design in single row600 MM to 900 MM Dia-Reusable 600 to900mm dia. Hume pipe |
| 420 | Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. Ordinary soil By Mechanical means |
| 421 | Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. Ordinary rock (not requiring blasting) Upto 3 m depth |
| 422 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. ( Hard rock (blasting prohibited) |
| 423 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial.HARD rock (requiring blasting) |
| 424 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802,803, 1202 & 1203P.C.C grade M 10 Nominal mix (1:3:6) |
| 425 | Plain/reinforced cement concrete in sub structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix (1:2.5:5) |
| 426 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 mm NP3 Class As per Technical Specification MORD 2014 Cluase No. 1100 |
| 427 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.600 mm NP3 Pipe |
| 428 | Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106..600 mm NP2 Pipe |
| 429 | Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered/concrete surfaces as per drawing and Technical Specification Clause 1701 |
| 430 | Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701 |
| 431 | Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709, 1204.3.7 A.C. pipe 100 mm Dia |
| 432 | Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W \"metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)\" |
| 433 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. |
| 434 | Providingdryrubble latrite stone masonarywith available material. (lead 50 mt) |
| 435 | Providingdry rubble latrite stone masonary ( including royalty ) (lead 50 mt) |
| 436 | Providing laterite stone masonry in cement mortar 1:6 in super structure including racking out joints when plastering is to be done /striking joints when no plastering is to be done watering and scaffolding |
| 437 | Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600mmwith smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height , compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8 |
| 438 | Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 |
| 439 | Backfilling behind abutment, wing wall and return wallwith Granular Material complete as per drawings & technical specification Clause 1204.3.8 |
| 440 | Providing and laying cement concrete wearing course M 30 grade Excluding reinforcementcomplete as per drawing and technical specifications Clauses 800 and 1206.3 |
| 441 | Dewatering including diversion of streame providing coffer dam bunds etc as may be necessary for foundation and other parts of the work and bailling out water during and after excavation required- for abutment |
| 442 | FillingFilllingin foundationtrenchesasperdrawingandtechnicalspecificationClause 305.3.9(I) SandFilling |
| 443 | Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5. II. R.C.C M 25 |
| 444 | Boulder ApronProvidingand laying of boulder apron laid in wire crates with4 mm dia GI wire conforming to lS:2S0 and IS:4S26in 100 mm x 100mm mesh(woven diagonally)including10 per cent extraforlapsandjointslaidwithstonebouldersweighingnotlessthan25kg eachasper drawing and technical specifications Clause 1301 |
| 445 | RCC M 25 i Ral’tProviding concrete for plain/reinforced concrete in open foundations complete as per drawingsandtechnicalspecificationsClause802,803,1202&1203.UsingVSIstandard Artificial Sand. |
| 446 | RCC M 30 in SuperstructureProviding and laying reinforced cement concrete in technical specifications Clauses 800. 1205.4 and 1205.5 11) R.C.C M 30 with VSI Standard artificial sand. |
| 447 | PCC M 15 below approachSlabP.C.C.M15ordinarygrade(1:2.5:5)levellingcoursebelowapproachslabcompleteasper drawing and technical specifications Clauses 800 and 1211 (i) Nominal mix (1:2.5:5)with VSI standard aftificial sand |
| 448 | Supplying, fitting and placingTMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202 |
| 449 | Supplying, fitting, and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 |
| 450 | Supplying ,fitting and placingTMT bar reinforcement in Superstructure complete as per drawings and technical specification Clauses 1002,1010,and 1202 |
| 451 | Expansion joint with 25 mm thich bitumenous pad / Compressible Rubber Pad (Rate as per PWDCSR for 2018-19) BR 43B Item no.14.33 pg no.123 |
| 452 | Providingand laying 0.90 meter thick metal mat consisting of rubble, oversize metal and normal size metal in specified thickness as per detailed drawing including supplying all materials, hand packing of rubble, spreading metal in layers and hard murum including watering and compaction with power roller etc. complete. |
| 453 | Anti-Crash Barrier(M30):-Providing Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with R.C.C. M 30 Grade concrete with HYSD reinforcement conforming to IRC:21 and dowel bars 25 mm Dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclosure to MOST circular No.RW/NH - 33022/1/94-DO III dated 24 June 1994 as per dimensions in the approved drawing and at locations directed by the Engineer, all as specified etc. complete. Spec: MORT and H 2013 Cl 811 Page No 360 |
| 454 | Providing and fillling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per cent bitumen by weight. |
| 455 | Diversion for bridge |
| 456 | Electric Pole Paintinng- Providing and fixing reflective fluorescent tape on old road sign board including cleaning / scraping and paintingexisting board etc. complete |
| 457 | Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015). |
| 458 | Cat Eye-Supplying & Fixing of Molded Shank Raised Pavement Markers / Cat\"s Eyemade of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer\"s recommendation and complete as directed by the engineer.The contractor shall submit a two year warrantyfor satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer. |
| 459 | Providing and Laying of Rumble strips with Plastirib 2K, or equivalent 2 component cold plastic profiled material to give total width of 500 mm and height of 10 mm. Ramp provided to give width of 145 mm, width of ribs to be 55mm laid at centre to centre distance of 35 mm, with reflective glass beads @ 350 gm / sqm. The finished surface to be levelled, uniform and free from streaks and holes, to be applied on the edge lines, including surface cleaning and cost of all materials etc. complete. |
| 460 | Painting Trees-Providing white and colour washing to road side trees in 2coats in 2 bands of white and one red band at centre of 30 cm height each including preparing the surface, cost of material, conveying etc. complete. |
| 461 | 8.00 -Upgradation & Maintenance of RoadFrom Karul DhangarwadiRoad. Km. 0.000 to 3.400 Km. Tal-Vaibhavwadi, Dist -Sindhudurg. |
| 462 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (A) In area of Non-thorny jungle |
| 463 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (B) In area of thorny jungle |
| 464 | Excavation for roadwork in soil with hydraulic excavator of0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and croun-sections, and transporting to the embankment location with a lift upto 1.5 m and lead above 1000 m as per Technical Specification MORD 2014 Clause 302.3 |
| 465 | Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead above 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and croun-sections as per Technical Specification MORD 2014 Clause 302.3.5 |
| 466 | Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and croun-sections, loading and disposal of cut rock with a lift upto 1.5 m and with all leadsas per Technical Specification MORD 2014 Clause 302.3.5 |
| 467 | Excavation in Hard Rock (blasting Prohibited) -Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 metre and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5 |
| 468 | Excavation in Hard Rock (Controlled Blasting) -Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 metre and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5 |
| 469 | Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1. |
| 470 | Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical SpecificationClause 301.5 |
| 471 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. |
| 472 | Scarifying the existing Bituminous surface to a depth of 150 mm and disposal ofscarified material with a lift up to 3 m and lead upto 1000 mas per technical specificationaClause 301.4 |
| 473 | Construction of Granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavatorat OMC, and compacting with smoothwheelroller to achieve thedesired density, complete as per Technical SpecificationClause 401. For Grading I material by mix in Place Method |
| 474 | Water Bound MacadamGrading II-(using Crusher Broken Metal & stone screening) Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smoothwheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. |
| 475 | Reinforced cement concrete M15grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703Ordinary Kilometer Stone (Precast) |
| 476 | Reinforced cement concrete M15grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703200 m stone (precast) |
| 477 | Providing andfixing trap/granite/ quartzite/ gneiss/ guard stone/ indicator stones/ boundry stones of standard size& shape includingfixingIn ground andwashing complete Spec. No.: MORTH 807 |
| 478 | Providing and fixingRetro Reflective MMGSY/PMGSY LOGO informatory sign board with Logo as per section 1700 of MORD specification sand latest PMGSY Signage Manual/Circuler and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600 mm size, rivete dwith MS angle ironframe of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle ironframe of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat ironframe will be done neatly to have plain surface on one side. The angle ironframe of Both the plates will be welded to a 75mmx75mmx12 swg Mild steel post at/Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200 mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY/PMGSY logo, letters and numeral sonthe ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade asper the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo MMGSY Logo Project description on ClassA or ClassB type retroreflective sheeting using modern technology printing plat form. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The in k sused for printing shall be ecofriendly with VOC emissions complying to UL2801 standards and specifications for the different kinds of plat forms. The printe dsign shall be laminated by UV protected laminate and shall carry awarranty of 5 years & 7 years for ClassA and ClassB sheeting respectively for traffic colors.” All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1(B) and as directed by Engineerin-charge. A warranty for 5/7 years for the Retroreflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.(SOR ITEM NO.10.16 ) A) Retro Reflective sheeting class-A |
| 479 | Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4 mmt hick ACP sheet supported with Back support frame of 35x35x5 mm mild steel angle with are as not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm-3.5mt rheight, firmly fixed to the ground by means of properly designed foundation of M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level complete (as per MoRT & H specification No.801) (for area Less than 0.9 sqm). 7 Both border & background shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product offered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. The reshall be as tamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.(Village Name Board) |
| 480 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm equilateral triangular |
| 481 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm circular |
| 482 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting c. 600 x 450 mm Rectangular |
| 483 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting900 x 600milimeter reclangular |
| 484 | MMGSY/PMGSY Citizen\"s information Board-Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specification sand latest PMGSY Sign age Manual/Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35x35x5mm thic kM. Sangle shall be welded by two vertical M.S angle of 5mm thick to 75mmx75mm of 12 SWG square tubes/75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mmx600mmx75mm, below ground level . MMGSY/PMGSY logo, letter sand numer also n the ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade as per the latest MORD section1700 specifications (Refer Circuler no. NRRDA-P 013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo /MMGSY Logo/Project descriptionon ClassA or ClassB type retroreflective sheeting using modern technology printing platform. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The inks used for printing shall bee co friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of plat forms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed post sand steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed |
| 485 | Painting lines, Dashes, Arrows, etc. on Road in Two Coats on New Work,Painting lines, dashes, arrows, etc. on roads in two coatson new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702 SR.NO 10.7 P.NO 42 |
| 486 | Providing and fixing Road junction / Information sign board of size 1.20 m x 1.20 m. prepared on 16 gauge M.S. sheet with angle iron frame of size 35 x 35 x 5 mm with cross bracing of size 35 x 35 x 5 mm including painting with one coat of zinc cromate stoving primer and two coats each of green/white back ground and back side gray stove enamelled, bonded with red retro reflective sheet Engineering grade, border / letters / numeral /arrows, coated with non pealable crystal clear protective transperent coat retaining 100% reflection includingtwo angle iron post of size 65 x 65x 6 mm of 3.65 m.long inflated at bottom drilled on top and painted in whiteand black bands of 30 cm. with 4 Nos. high strength G.I. bolts and nuts of size 10 mm dia. and 20 mm long sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with M-20 cement concrete of 60 cm x 60 cm x 75 cm size as directed by Engineer-in charge etc. complete. Mild Steel sheet with Engineering grade |
| 487 | Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazardmarkers, Object markers) 80 to 100 cm high above ground level, painted black and whitein 15 cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circularreflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C.79 and the drawings |
| 488 | Construction of Dry Lean Cement Concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to 15: 383, the size of coarse aggregate not exceeding 25 mm., cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing andincluding preparation of sub-grade surface if required etc. complete. |
| 489 | Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolana Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate (VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer In charge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc, complete as per specifications. (Excluding Dowel Bars and Tie Bars) |
| 490 | Providing and fixing in position 25mm dia anti corrosive MS Dowel bars of required Dia.60 cms. Long and at 30.00 cm. C/C and wherever directed including handling. straightening, necessary cutting supported by chairs with proper alignment with half length covered by polyethene sheathing including cap etc. complete. |
| 491 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. |
| 492 | Removing all types of Hume pipes and stackig within a lead of 1000 m including Earthwork and Dismantling of Masonry work as per Technical Specification clause 202- Above 600 to900mm dia. Hume pipe |
| 493 | Laying Reinforced Cement Concrete Pipe NP2 as per design in single row600 MM to 900 MM Dia-Reusable 600 to900mm dia. Hume pipe |
| 494 | Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. Ordinary soil By Mechanical means |
| 495 | Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. Ordinary rock (not requiring blasting) Upto 3 m depth |
| 496 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. ( Hard rock (blasting prohibited) |
| 497 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial.HARD rock (requiring blasting) |
| 498 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802,803, 1202 & 1203P.C.C grade M 10 Nominal mix (1:3:6) |
| 499 | Plain/reinforced cement concrete in sub structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix (1:2.5:5) |
| 500 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 mm NP3 Class As per Technical Specification MORD 2014 Cluase No. 1100 |
| 501 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.600 mm NP3 Pipe |
| 502 | Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106..600 mm NP2 Pipe |
| 503 | Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered/concrete surfaces as per drawing and Technical Specification Clause 1701 |
| 504 | Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701 |
| 505 | Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709, 1204.3.7 A.C. pipe 100 mm Dia |
| 506 | Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W \"metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)\" |
| 507 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. |
| 508 | Providingdryrubble latrite stone masonarywith available material. (lead 50 mt) |
| 509 | Providingdry rubble latrite stone masonary ( including royalty ) (lead 50 mt) |
| 510 | Providing laterite stone masonry in cement mortar 1:6 in super structure including racking out joints when plastering is to be done /striking joints when no plastering is to be done watering and scaffolding |
| 511 | Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 |
| 512 | Backfilling behind abutment, wing wall and return wallwith Granular Material complete as per drawings & technical specification Clause 1204.3.8 |
| 513 | Providing and laying cement concrete wearing course M 30 grade Excluding reinforcementcomplete as per drawing and technical specifications Clauses 800 and 1206.3 |
| 514 | Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 |
| 515 | Electric Pole Paintinng- Providing and fixing reflective fluorescent tape on old road sign board including cleaning / scraping and paintingexisting board etc. complete |
| 516 | Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015). |
| 517 | Cat Eye-Supplying & Fixing of Molded Shank Raised Pavement Markers / Cat\"s Eyemade of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer\"s recommendation and complete as directed by the engineer.The contractor shall submit a two year warrantyfor satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer. |
| 518 | Providing and Laying of Rumble strips with Plastirib 2K, or equivalent 2 component cold plastic profiled material to give total width of 500 mm and height of 10 mm. Ramp provided to give width of 145 mm, width of ribs to be 55mm laid at centre to centre distance of 35 mm, with reflective glass beads @ 350 gm / sqm. The finished surface to be levelled, uniform and free from streaks and holes, to be applied on the edge lines, including surface cleaning and cost of all materials etc. complete. |
| 519 | Painting Trees-Providing white and colour washing to road side trees in 2coats in 2 bands of white and one red band at centre of 30 cm height each including preparing the surface, cost of material, conveying etc. complete. |
| 520 | 9.00 -Upgradation & Maintenance of RoadFrom Nadhavde -boudhwadi Helekarwadi sherpeRoad. Km. 0.000 to 3.000 Km. Tal-Vaibhavwadi, Dist -Sindhudurg. |
| 521 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (A) In area of Non-thorny jungle |
| 522 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (B) In area of thorny jungle |
| 523 | Excavation for roadwork in soil with hydraulic excavator of0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and croun-sections, and transporting to the embankment location with a lift upto 1.5 m and lead above 1000 m as per Technical Specification MORD 2014 Clause 302.3 |
| 524 | Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead above 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and croun-sections as per Technical Specification MORD 2014 Clause 302.3.5 |
| 525 | Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and croun-sections, loading and disposal of cut rock with a lift upto 1.5 m and with all leadsas per Technical Specification MORD 2014 Clause 302.3.5 |
| 526 | Excavation in Hard Rock (blasting Prohibited) -Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 metre and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5 |
| 527 | Excavation in Hard Rock (Controlled Blasting) -Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 metre and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5 |
| 528 | Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical SpecificationClause 301.5 |
| 529 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. |
| 530 | Scarifying the existing Bituminous surface to a depth of 150 mm and disposal ofscarified material with a lift up to 3 m and lead upto 1000 mas per technical specificationaClause 301.4 |
| 531 | Construction of Granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavatorat OMC, and compacting with smoothwheelroller to achieve thedesired density, complete as per Technical SpecificationClause 401. For Grading I material by mix in Place Method |
| 532 | Water Bound MacadamGrading II-(using Crusher Broken Metal & stone screening) Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smoothwheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. |
| 533 | Reinforced cement concrete M15grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703Ordinary Kilometer Stone (Precast) |
| 534 | Reinforced cement concrete M15grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703200 m stone (precast) |
| 535 | Providing andfixing trap/granite/ quartzite/ gneiss/ guard stone/ indicator stones/ boundry stones of standard size& shape includingfixingIn ground andwashing complete Spec. No.: MORTH 807 |
| 536 | Providing and fixingRetro Reflective MMGSY/PMGSY LOGO informatory sign board with Logo as per section 1700 of MORD specification sand latest PMGSY Signage Manual/Circuler and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600 mm size, rivete dwith MS angle ironframe of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle ironframe of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat ironframe will be done neatly to have plain surface on one side. The angle ironframe of Both the plates will be welded to a 75mmx75mmx12 swg Mild steel post at/Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200 mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY/PMGSY logo, letters and numeral sonthe ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade asper the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo MMGSY Logo Project description on ClassA or ClassB type retroreflective sheeting using modern technology printing plat form. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The in k sused for printing shall be ecofriendly with VOC emissions complying to UL2801 standards and specifications for the different kinds of plat forms. The printe dsign shall be laminated by UV protected laminate and shall carry awarranty of 5 years & 7 years for ClassA and ClassB sheeting respectively for traffic colors.” All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1(B) and as directed by Engineerin-charge. A warranty for 5/7 years for the Retroreflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.(SOR ITEM NO.10.16 ) A) Retro Reflective sheeting class-A |
| 537 | Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4 mmt hick ACP sheet supported with Back support frame of 35x35x5 mm mild steel angle with are as not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm-3.5mt rheight, firmly fixed to the ground by means of properly designed foundation of M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level complete (as per MoRT & H specification No.801) (for area Less than 0.9 sqm). 7 Both border & background shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product offered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. The reshall be as tamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.(Village Name Board) |
| 538 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm equilateral triangular |
| 539 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm circular |
| 540 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting c. 600 x 450 mm Rectangular |
| 541 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting900 x 600milimeter reclangular |
| 542 | MMGSY/PMGSY Citizen\"s information Board-Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specification sand latest PMGSY Sign age Manual/Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35x35x5mm thic kM. Sangle shall be welded by two vertical M.S angle of 5mm thick to 75mmx75mm of 12 SWG square tubes/75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mmx600mmx75mm, below ground level . MMGSY/PMGSY logo, letter sand numer also n the ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade as per the latest MORD section1700 specifications (Refer Circuler no. NRRDA-P 013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo /MMGSY Logo/Project descriptionon ClassA or ClassB type retroreflective sheeting using modern technology printing platform. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The inks used for printing shall bee co friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of plat forms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed post sand steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed |
| 543 | Painting lines, Dashes, Arrows, etc. on Road in Two Coats on New Work,Painting lines, dashes, arrows, etc. on roads in two coatson new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702 SR.NO 10.7 P.NO 42 |
| 544 | Providing and fixing Road junction / Information sign board of size 1.20 m x 1.20 m. prepared on 16 gauge M.S. sheet with angle iron frame of size 35 x 35 x 5 mm with cross bracing of size 35 x 35 x 5 mm including painting with one coat of zinc cromate stoving primer and two coats each of green/white back ground and back side gray stove enamelled, bonded with red retro reflective sheet Engineering grade, border / letters / numeral /arrows, coated with non pealable crystal clear protective transperent coat retaining 100% reflection includingtwo angle iron post of size 65 x 65x 6 mm of 3.65 m.long inflated at bottom drilled on top and painted in whiteand black bands of 30 cm. with 4 Nos. high strength G.I. bolts and nuts of size 10 mm dia. and 20 mm long sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with M-20 cement concrete of 60 cm x 60 cm x 75 cm size as directed by Engineer-in charge etc. complete. Mild Steel sheet with Engineering grade |
| 545 | Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazardmarkers, Object markers) 80 to 100 cm high above ground level, painted black and whitein 15 cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circularreflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C.79 and the drawings |
| 546 | Construction of Dry Lean Cement Concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to 15: 383, the size of coarse aggregate not exceeding 25 mm., cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing andincluding preparation of sub-grade surface if required etc. complete. |
| 547 | Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolana Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate (VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer In charge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc, complete as per specifications. (Excluding Dowel Bars and Tie Bars) |
| 548 | Providing and fixing in position 25mm dia anti corrosive MS Dowel bars of required Dia.60 cms. Long and at 30.00 cm. C/C and wherever directed including handling. straightening, necessary cutting supported by chairs with proper alignment with half length covered by polyethene sheathing including cap etc. complete. |
| 549 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. |
| 550 | Removing all types of Hume pipes and stackig within a lead of 1000 m including Earthwork and Dismantling of Masonry work as per Technical Specification clause 202- Above 600 to900mm dia. Hume pipe |
| 551 | Laying Reinforced Cement Concrete Pipe NP2 as per design in single row600 MM to 900 MM Dia-Reusable 600 to900mm dia. Hume pipe |
| 552 | Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. Ordinary soil By Mechanical means |
| 553 | Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. Ordinary rock (not requiring blasting) Upto 3 m depth |
| 554 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. ( Hard rock (blasting prohibited) |
| 555 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial.HARD rock (requiring blasting) |
| 556 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802,803, 1202 & 1203P.C.C grade M 10 Nominal mix (1:3:6) |
| 557 | Plain/reinforced cement concrete in sub structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix (1:2.5:5) |
| 558 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 mm NP3 Class As per Technical Specification MORD 2014 Cluase No. 1100 |
| 559 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. A. 1200 mm NP3 Class As per Technical Specification MORD 2014 Cluase No. 1100 |
| 560 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.600 mm NP3 Pipe |
| 561 | Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106..600 mm NP2 Pipe |
| 562 | Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered/concrete surfaces as per drawing and Technical Specification Clause 1701 |
| 563 | Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701 |
| 564 | Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709, 1204.3.7 A.C. pipe 100 mm Dia |
| 565 | Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W \"metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)\" |
| 566 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. |
| 567 | Providingdryrubble latrite stone masonarywith available material. (lead 50 mt) |
| 568 | Providingdry rubble latrite stone masonary ( including royalty ) (lead 50 mt) |
| 569 | Providing laterite stone masonry in cement mortar 1:6 in super structure including racking out joints when plastering is to be done /striking joints when no plastering is to be done watering and scaffolding |
| 570 | Backfilling behind abutment, wing wall and return wallwith Granular Material complete as per drawings & technical specification Clause 1204.3.8 |
| 571 | Providing and laying cement concrete wearing course M 30 grade Excluding reinforcementcomplete as per drawing and technical specifications Clauses 800 and 1206.3 |
| 572 | Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 |
| 573 | Electric Pole Paintinng- Providing and fixing reflective fluorescent tape on old road sign board including cleaning / scraping and paintingexisting board etc. complete |
| 574 | Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015). |
| 575 | Cat Eye-Supplying & Fixing of Molded Shank Raised Pavement Markers / Cat\"s Eyemade of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer\"s recommendation and complete as directed by the engineer.The contractor shall submit a two year warrantyfor satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer. |
| 576 | Providing and Laying of Rumble strips with Plastirib 2K, or equivalent 2 component cold plastic profiled material to give total width of 500 mm and height of 10 mm. Ramp provided to give width of 145 mm, width of ribs to be 55mm laid at centre to centre distance of 35 mm, with reflective glass beads @ 350 gm / sqm. The finished surface to be levelled, uniform and free from streaks and holes, to be applied on the edge lines, including surface cleaning and cost of all materials etc. complete. |
| 577 | Painting Trees-Providing white and colour washing to road side trees in 2coats in 2 bands of white and one red band at centre of 30 cm height each including preparing the surface, cost of material, conveying etc. complete. |
| 578 | 10.00 -Upgradation & Maintenance of RoadFrom Karul To Kumbhavade-KusurRoad. Km. 0.000 to 1.00& 5.20 TO 8.20Km. Tal-Vaibhavwadi, Dist -Sindhudurg. |
| 579 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (A) In area of Non-thorny jungle |
| 580 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (B) In area of thorny jungle |
| 581 | Excavation for roadwork in soil with hydraulic excavator of0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and croun-sections, and transporting to the embankment location with a lift upto 1.5 m and lead above 1000 m as per Technical Specification MORD 2014 Clause 302.3 |
| 582 | Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead above 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and croun-sections as per Technical Specification MORD 2014 Clause 302.3.5 |
| 583 | Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and croun-sections, loading and disposal of cut rock with a lift upto 1.5 m and with all leadsas per Technical Specification MORD 2014 Clause 302.3.5 |
| 584 | Excavation in Hard Rock (blasting Prohibited) -Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 metre and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5 |
| 585 | Excavation in Hard Rock (Controlled Blasting) -Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 metre and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5 |
| 586 | Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1. |
| 587 | Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical SpecificationClause 301.5 |
| 588 | Scarifying the existing Bituminous surface to a depth of 150 mm and disposal ofscarified material with a lift up to 3 m and lead upto 1000 mas per technical specificationaClause 301.4 |
| 589 | Construction of Granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavatorat OMC, and compacting with smoothwheelroller to achieve thedesired density, complete as per Technical SpecificationClause 401. For Grading I material by mix in Place Method |
| 590 | Water Bound MacadamGrading II-(using Crusher Broken Metal & stone screening) Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smoothwheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. |
| 591 | Reinforced cement concrete M15grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703Ordinary Kilometer Stone (Precast) |
| 592 | Reinforced cement concrete M15grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703200 m stone (precast) |
| 593 | Providing andfixing trap/granite/ quartzite/ gneiss/ guard stone/ indicator stones/ boundry stones of standard size& shape includingfixingIn ground andwashing complete Spec. No.: MORTH 807 |
| 594 | Providing and fixingRetro Reflective MMGSY/PMGSY LOGO informatory sign board with Logo as per section 1700 of MORD specification sand latest PMGSY Signage Manual/Circuler and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600 mm size, rivete dwith MS angle ironframe of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle ironframe of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat ironframe will be done neatly to have plain surface on one side. The angle ironframe of Both the plates will be welded to a 75mmx75mmx12 swg Mild steel post at/Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200 mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY/PMGSY logo, letters and numeral sonthe ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade asper the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo MMGSY Logo Project description on ClassA or ClassB type retroreflective sheeting using modern technology printing plat form. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The in k sused for printing shall be ecofriendly with VOC emissions complying to UL2801 standards and specifications for the different kinds of plat forms. The printe dsign shall be laminated by UV protected laminate and shall carry awarranty of 5 years & 7 years for ClassA and ClassB sheeting respectively for traffic colors.” All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1(B) and as directed by Engineerin-charge. A warranty for 5/7 years for the Retroreflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.(SOR ITEM NO.10.16 ) A) Retro Reflective sheeting class-A |
| 595 | Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4 mmt hick ACP sheet supported with Back support frame of 35x35x5 mm mild steel angle with are as not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm-3.5mt rheight, firmly fixed to the ground by means of properly designed foundation of M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level complete (as per MoRT & H specification No.801) (for area Less than 0.9 sqm). 7 Both border & background shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product offered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. The reshall be as tamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.(Village Name Board) |
| 596 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm equilateral triangular |
| 597 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm circular |
| 598 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting c. 600 x 450 mm Rectangular |
| 599 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting900 x 600milimeter reclangular |
| 600 | MMGSY/PMGSY Citizen\"s information Board-Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specification sand latest PMGSY Sign age Manual/Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35x35x5mm thic kM. Sangle shall be welded by two vertical M.S angle of 5mm thick to 75mmx75mm of 12 SWG square tubes/75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mmx600mmx75mm, below ground level . MMGSY/PMGSY logo, letter sand numer also n the ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade as per the latest MORD section1700 specifications (Refer Circuler no. NRRDA-P 013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo /MMGSY Logo/Project descriptionon ClassA or ClassB type retroreflective sheeting using modern technology printing platform. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The inks used for printing shall bee co friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of plat forms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed post sand steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed |
| 601 | Painting lines, Dashes, Arrows, etc. on Road in Two Coats on New Work,Painting lines, dashes, arrows, etc. on roads in two coatson new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702 SR.NO 10.7 P.NO 42 |
| 602 | Providing and fixing Road junction / Information sign board of size 1.20 m x 1.20 m. prepared on 16 gauge M.S. sheet with angle iron frame of size 35 x 35 x 5 mm with cross bracing of size 35 x 35 x 5 mm including painting with one coat of zinc cromate stoving primer and two coats each of green/white back ground and back side gray stove enamelled, bonded with red retro reflective sheet Engineering grade, border / letters / numeral /arrows, coated with non pealable crystal clear protective transperent coat retaining 100% reflection includingtwo angle iron post of size 65 x 65x 6 mm of 3.65 m.long inflated at bottom drilled on top and painted in whiteand black bands of 30 cm. with 4 Nos. high strength G.I. bolts and nuts of size 10 mm dia. and 20 mm long sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with M-20 cement concrete of 60 cm x 60 cm x 75 cm size as directed by Engineer-in charge etc. complete. Mild Steel sheet with Engineering grade |
| 603 | Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazardmarkers, Object markers) 80 to 100 cm high above ground level, painted black and whitein 15 cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circularreflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C.79 and the drawings |
| 604 | Construction of Dry Lean Cement Concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to 15: 383, the size of coarse aggregate not exceeding 25 mm., cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing andincluding preparation of sub-grade surface if required etc. complete. |
| 605 | Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolana Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate (VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer In charge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc, complete as per specifications. (Excluding Dowel Bars and Tie Bars) |
| 606 | Providing and fixing in position 25mm dia anti corrosive MS Dowel bars of required Dia.60 cms. Long and at 30.00 cm. C/C and wherever directed including handling. straightening, necessary cutting supported by chairs with proper alignment with half length covered by polyethene sheathing including cap etc. complete. |
| 607 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. |
| 608 | Removing all types of Hume pipes and stackig within a lead of 1000 m including Earthwork and Dismantling of Masonry work as per Technical Specification clause 202- Above 600 to900mm dia. Hume pipe |
| 609 | Laying Reinforced Cement Concrete Pipe NP2 as per design in single row600 MM to 900 MM Dia-Reusable 600 to900mm dia. Hume pipe |
| 610 | Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. Ordinary soil By Mechanical means |
| 611 | Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. Ordinary rock (not requiring blasting) Upto 3 m depth |
| 612 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. ( Hard rock (blasting prohibited) |
| 613 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial.HARD rock (requiring blasting) |
| 614 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802,803, 1202 & 1203P.C.C grade M 10 Nominal mix (1:3:6) |
| 615 | Plain/reinforced cement concrete in sub structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix (1:2.5:5) |
| 616 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 mm NP3 Class As per Technical Specification MORD 2014 Cluase No. 1100 |
| 617 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.600 mm NP3 Pipe |
| 618 | Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106..600 mm NP2 Pipe |
| 619 | Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered/concrete surfaces as per drawing and Technical Specification Clause 1701 |
| 620 | Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701 |
| 621 | Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709, 1204.3.7 A.C. pipe 100 mm Dia |
| 622 | Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W \"metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)\" |
| 623 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. |
| 624 | Providingdryrubble latrite stone masonarywith available material. (lead 50 mt) |
| 625 | Providingdry rubble latrite stone masonary ( including royalty ) (lead 50 mt) |
| 626 | Providing laterite stone masonry in cement mortar 1:6 in super structure including racking out joints when plastering is to be done /striking joints when no plastering is to be done watering and scaffolding |
| 627 | Backfilling behind abutment, wing wall and return wallwith Granular Material complete as per drawings & technical specification Clause 1204.3.8 |
| 628 | Providing and laying cement concrete wearing course M 30 grade Excluding reinforcementcomplete as per drawing and technical specifications Clauses 800 and 1206.3 |
| 629 | Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 |
| 630 | Electric Pole Paintinng- Providing and fixing reflective fluorescent tape on old road sign board including cleaning / scraping and paintingexisting board etc. complete |
| 631 | Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015). |
| 632 | Cat Eye-Supplying & Fixing of Molded Shank Raised Pavement Markers / Cat\"s Eyemade of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer\"s recommendation and complete as directed by the engineer.The contractor shall submit a two year warrantyfor satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer. |
| 633 | Providing and Laying of Rumble strips with Plastirib 2K, or equivalent 2 component cold plastic profiled material to give total width of 500 mm and height of 10 mm. Ramp provided to give width of 145 mm, width of ribs to be 55mm laid at centre to centre distance of 35 mm, with reflective glass beads @ 350 gm / sqm. The finished surface to be levelled, uniform and free from streaks and holes, to be applied on the edge lines, including surface cleaning and cost of all materials etc. complete. |
| 634 | Painting Trees-Providing white and colour washing to road side trees in 2coats in 2 bands of white and one red band at centre of 30 cm height each including preparing the surface, cost of material, conveying etc. complete. |
| 635 | 11.00 -Upgradation & Maintenance of RoadFrom MDR 12 to Vareri Dabhole Pokharbav Road. Km. 0.000 to 3.700 Km. Tal-Devgad, Dist -Sindhudurg. |
| 636 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (A) In area of Non-thorny jungle |
| 637 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (B) In area of thorny jungle |
| 638 | Excavation for roadwork in soil with hydraulic excavator of0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and croun-sections, and transporting to the embankment location with a lift upto 1.5 m and lead above 1000 m as per Technical Specification MORD 2014 Clause 302.3 |
| 639 | Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead above 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and croun-sections as per Technical Specification MORD 2014 Clause 302.3.5 |
| 640 | Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and croun-sections, loading and disposal of cut rock with a lift upto 1.5 m and with all leadsas per Technical Specification MORD 2014 Clause 302.3.5 |
| 641 | Excavation in Hard Rock (blasting Prohibited) -Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 metre and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5 |
| 642 | Excavation for roadway in hard rockwith controlledblasting by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads upto 1000 mas per Technical Specification Clause 302.3.5 |
| 643 | Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1. |
| 644 | Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical SpecificationClause 301.5 |
| 645 | Construction of embankment with approved material obtained from borrow pits with al ift upto 1.5m, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 |
| 646 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. |
| 647 | Scarifying the existing Bituminous surface to a depth of 150 mm and disposal ofscarified material with a lift up to 3 m and lead upto 1000 mas per technical specificationaClause 301.4 |
| 648 | Construction of Granular Sub baseusing locally available materialProviding, laying spreading and compacting local material in block or large discrete particles, such as kankar, Laterite, Dhandla etc. as per Table 400.13 to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming requisite type of screening /binding materials to fill-up theinterstices of laid material watering and compacting to the required density as per Clause 405.3 and Technical Specification Cluase 408. Using Locally Availablematerial |
| 649 | Water Bound MacadamGrading II-(using Crusher Broken Metal & stone screening) Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smoothwheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. |
| 650 | Reinforced cement concrete M15grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703Ordinary Kilometer Stone (Precast) |
| 651 | Reinforced cement concrete M15grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703200 m stone (precast) |
| 652 | Providing andfixing trap/granite/ quartzite/ gneiss/ guard stone/ indicator stones/ boundry stones of standard size& shape includingfixingIn ground andwashing complete Spec. No.: MORTH 807 |
| 653 | Providing and fixingRetro Reflective MMGSY/PMGSY LOGO informatory sign board with Logo as per section 1700 of MORD specification sand latest PMGSY Signage Manual/Circuler and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600 mm size, rivete dwith MS angle ironframe of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle ironframe of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat ironframe will be done neatly to have plain surface on one side. The angle ironframe of Both the plates will be welded to a 75mmx75mmx12 swg Mild steel post at/Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200 mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY/PMGSY logo, letters and numeral sonthe ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade asper the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo MMGSY Logo Project description on ClassA or ClassB type retroreflective sheeting using modern technology printing plat form. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The in k sused for printing shall be ecofriendly with VOC emissions complying to UL2801 standards and specifications for the different kinds of plat forms. The printe dsign shall be laminated by UV protected laminate and shall carry awarranty of 5 years & 7 years for ClassA and ClassB sheeting respectively for traffic colors.” All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1(B) and as directed by Engineerin-charge. A warranty for 5/7 years for the Retroreflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.(SOR ITEM NO.10.16 ) A) Retro Reflective sheeting class-A |
| 654 | Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4 mmt hick ACP sheet supported with Back support frame of 35x35x5 mm mild steel angle with are as not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm-3.5mt rheight, firmly fixed to the ground by means of properly designed foundation of M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level complete (as per MoRT & H specification No.801) (for area Less than 0.9 sqm). 7 Both border & background shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product offered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. The reshall be as tamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.(Village Name Board) |
| 655 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm equilateral triangular |
| 656 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm circular |
| 657 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting c. 600 x 450 mm Rectangular |
| 658 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting900 x 600milimeter reclangular |
| 659 | MMGSY/PMGSY Citizen\"s information Board-Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specification sand latest PMGSY Sign age Manual/Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35x35x5mm thic kM. Sangle shall be welded by two vertical M.S angle of 5mm thick to 75mmx75mm of 12 SWG square tubes/75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mmx600mmx75mm, below ground level . MMGSY/PMGSY logo, letter sand numer also n the ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade as per the latest MORD section1700 specifications (Refer Circuler no. NRRDA-P 013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo /MMGSY Logo/Project descriptionon ClassA or ClassB type retroreflective sheeting using modern technology printing platform. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The inks used for printing shall bee co friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of plat forms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed post sand steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed |
| 660 | Painting lines, Dashes, Arrows, etc. on Road in Two Coats on New Work,Painting lines, dashes, arrows, etc. on roads in two coatson new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702 SR.NO 10.7 P.NO 42 |
| 661 | Providing and fixing Road junction / Information sign board of size 1.20 m x 1.20 m. prepared on 16 gauge M.S. sheet with angle iron frame of size 35 x 35 x 5 mm with cross bracing of size 35 x 35 x 5 mm including painting with one coat of zinc cromate stoving primer and two coats each of green/white back ground and back side gray stove enamelled, bonded with red retro reflective sheet Engineering grade, border / letters / numeral /arrows, coated with non pealable crystal clear protective transperent coat retaining 100% reflection includingtwo angle iron post of size 65 x 65x 6 mm of 3.65 m.long inflated at bottom drilled on top and painted in whiteand black bands of 30 cm. with 4 Nos. high strength G.I. bolts and nuts of size 10 mm dia. and 20 mm long sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with M-20 cement concrete of 60 cm x 60 cm x 75 cm size as directed by Engineer-in charge etc. complete. Mild Steel sheet with Engineering grade |
| 662 | Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings |
| 663 | Construction of Dry Lean Cement Concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to 15: 383, the size of coarse aggregate not exceeding 25 mm., cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing andincluding preparation of sub-grade surface if required etc. complete. |
| 664 | Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolana Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate (VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer In charge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc, complete as per specifications. (Excluding Dowel Bars and Tie Bars) |
| 665 | Providing and fixing in position 25mm dia anti corrosive MS Dowel bars of required Dia.60 cms. Long and at 30.00 cm. C/C and wherever directed including handling. straightening, necessary cutting supported by chairs with proper alignment with half length covered by polyethene sheathing including cap etc. complete. |
| 666 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. |
| 667 | Removing all types of Hume pipes and stackig within a lead of 1000 m including Earthwork and Dismantling of Masonry work as per Technical Specification clause 202- Above 600 to900mm dia. Hume pipe |
| 668 | Laying Reinforced Cement Concrete Pipe NP2 as per design in single row600 MM to 900 MM Dia-Reusable 600 to900mm dia. Hume pipe |
| 669 | Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. Ordinary soil By Mechanical means |
| 670 | Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. Ordinary rock (not requiring blasting) Upto 3 m depth |
| 671 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. ( Hard rock (blasting prohibited) |
| 672 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial.HARD rock (requiring blasting) |
| 673 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802,803, 1202 & 1203P.C.C grade M 10 Nominal mix (1:3:6) |
| 674 | Plain/reinforced cement concrete in sub structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix (1:2.5:5) |
| 675 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 mm NP3 Class As per Technical Specification MORD 2014 Cluase No. 1100 |
| 676 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.600 mm NP3 Pipe |
| 677 | Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106..600 mm NP2 Pipe |
| 678 | Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered/concrete surfaces as per drawing and Technical Specification Clause 1701 |
| 679 | Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701 |
| 680 | Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709, 1204.3.7 A.C. pipe 100 mm Dia |
| 681 | Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W \"metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)\" |
| 682 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. |
| 683 | Providingdryrubble latrite stone masonarywith available material. (lead 50 mt) |
| 684 | Providingdry rubble latrite stone masonary ( including royalty ) (lead 50 mt) |
| 685 | Providing laterite stone masonry in cement mortar 1:6 in super structure including racking out joints when plastering is to be done /striking joints when no plastering is to be done watering and scaffolding |
| 686 | Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600mmwith smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height , compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8 |
| 687 | Backfilling behind abutment, wing wall and return wallwith Granular Material complete as per drawings & technical specification Clause 1204.3.8 |
| 688 | Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 |
| 689 | Electric Pole Paintinng- Providing and fixing reflective fluorescent tape on old road sign board including cleaning / scraping and paintingexisting board etc. complete |
| 690 | Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015). |
| 691 | Cat Eye-Supplying & Fixing of Molded Shank Raised Pavement Markers / Cat\"s Eyemade of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer\"s recommendation and complete as directed by the engineer.The contractor shall submit a two year warrantyfor satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer. |
| 692 | Providing and Laying of Rumble strips with Plastirib 2K, or equivalent 2 component cold plastic profiled material to give total width of 500 mm and height of 10 mm. Ramp provided to give width of 145 mm, width of ribs to be 55mm laid at centre to centre distance of 35 mm, with reflective glass beads @ 350 gm / sqm. The finished surface to be levelled, uniform and free from streaks and holes, to be applied on the edge lines, including surface cleaning and cost of all materials etc. complete. |
| 693 | Painting Trees-Providing white and colour washing to road side trees in 2coats in 2 bands of white and one red band at centre of 30 cm height each including preparing the surface, cost of material, conveying etc. complete. |